Amendment 1 - Mineral oil-impregnated electrical equipment in service - Guide to the interpretation of dissolved and free gases analysis

Amendement 1 - Matériels électriques imprégnés d'huile minérale en service - Guide pour l'interprétation de l'analyse des gaz dissous et des gaz libres

General Information

Status
Published
Publication Date
10-Apr-2007
Current Stage
DELPUB - Deleted Publication
Completion Date
16-Sep-2015
Ref Project

Relations

Buy Standard

Standard
IEC 60599:1999/AMD1:2007 - Amendment 1 - Mineral oil-impregnated electrical equipment in service - Guide to the interpretation of dissolved and free gases analysis Released:4/11/2007 Isbn:2831891094
English and French language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL IEC
STANDARD
CEI
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
2007-04
Amendment 1
Mineral oil-impregnated electrical
equipment in service –
Guide to the interpretation of dissolved
and free gases analysis
Amendement 1
Matériels électriques imprégnés d’huile
minérale en service –
Guide pour l’interprétation de l’analyse
des gaz dissous et des gaz libres

Reference number
Numéro de référence
IEC/CEI 60599 Amend. 1:2007
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form

or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.

If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,

please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie

et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.

Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de
référence, texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou
remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
INTERNATIONAL IEC
STANDARD
CEI
NORME
INTERNATIONALE
AMENDEMENT 1
AMENDMENT 1
2007-04
Amendment 1
Mineral oil-impregnated electrical
equipment in service –
Guide to the interpretation of dissolved
and free gases analysis
Amendement 1
Matériels électriques imprégnés d’huile
minérale en service –
Guide pour l’interprétation de l’analyse
des gaz dissous et des gaz libres

PRICE CODE
D
CODE PRIX
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
Pour prix, voir catalogue en vigueur

– 2 – 60599 Amend. 1 © IEC:2007

FOREWORD
This amendment has been prepared by IEC technical committee 10:Fluids for electrotechnical

applications.
The text of this amendment is based on the following documents:

FDIS Report on voting
10/685/FDIS 10/693/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be:
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
___________
Page 43
Annex A – Equipment application notes
Replace the existing text of these notes with the following new text:
WARNING: “Limit values” of gas concentrations and rates of gas increase in service are not
the responsibility of TC10 but of IEC equipment committees.
“Typical values” in the following application notes are not limit values. They are given for
information only, as a maintenance tool. In a given transformer population, they indicate for
example that 90 % of DGA values in service are below the 90 % typical values and 10 % are
above. When typical values are exceeded, the only action recommended in this standard is to
increase the frequency of DGA analyses.
Typical values depend on several parameters (age, type and manufacturer of equipment,
operating and loading practices, climate, etc.), and are not exactly the same for all electrical
networks. Ranges of typical values are therefore indicated in the following application notes,
covering the different individual values observed worldwide and surveyed by IEC and CIGRE.

60599 Amend. 1 © IEC:2007 – 3 –

Individual networks are strongly encouraged to calculate the typical values corresponding to
their own specific transformer population, using DGA data meeting IEC 60567 specifications

for accuracy and following methods indicated in Clause 8 and in CIGRE Brochure # 296

(2006).
The ranges of typical values indicated in these application notes should be used only by

default, when individual values are not available, and should not be used in a contract without

a special agreement between the user and manufacturer of the equipment.

A.1 Power transformers
Delete the text of the paragraph under the title.

Page 47
Subclauses A.1.4 and A.1.5
Replace the text of these subclauses with the following new text:
A.1.4 Typical concentration values
Important note: the “WARNING” clause at the beginning of Annex A shall be consulted
before using A.1.4.
Ranges of 90 % typical gas concentration values observed in power transformers, from about
25 electrical networks worldwide and including more than 20 000 transformers, are given in
Table A.2. For hydrogen for example, one network reported a typical value of 50 μl/l, another
one 150 μl/l and the 23 others reported values between 50 μl/l and 150 μl/l. These ranges of
values have been reported by CIGRE SC D1 and A2 (TF11) and approved by IEC TC 10 and
TC 14.
Table A.2 – Ranges of 90 % typical gas concentration values
observed in power transformers, in μl/l
C H H CH C H C H CO CO
2 2 2 4 2 4 2 6 2
All transformers 50 - 150 30 - 130 60 - 280 20 - 90 400 - 600 3 800 -
14 000
No OLTC 2 - 20
Communicating OLTC 60 - 280
“Communicating OLTC” in Tables A.2 and A.3 means that some oil and/or gas communication
is possible between the OLTC compartment and the main tank or between the respective
conservators. These gases may contaminate the oil in the main tank and affect concentration
values in these types of equipment. “No OLTC” refers to transformers not equipped with an
OLTC, or equipped with a tap changer not communicating with or leaking to the main tank.

– 4 – 60599 Amend. 1 © IEC:2007

Typical values in Table A.2 apply to both breathing and sealed transformers, and correspond
mostly to core-type transformers. Values in shell-type transformers are likely to be higher. In

two countries, values for C H are higher. In one country where transformers are operated

2 6
below nominal load, values for CH and CO and particularly for C H are lower. In one