This part of IEC 61347 specifies particular safety requirements for electronic ballasts for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. This first edition of IEC 61347-2-3, together with IEC 61347-1, cancels and replaces the second edition of IEC 60928, published in 1995, and constitutes a minor revision. This standard shall be used in conjunction with IEC 61347-1. It was established on the basis of the first edition (2000) of that standard.
Appareillages de lampes - Partie 2-3: Prescriptions particulières pour les ballasts électroniques alimentés en courant alternatif pour lampes fluorescentes
La présente partie de la CEI 61347 spécifie les prescriptions particulières de sécurité applicables aux ballasts électroniques pour utilisation en courant alternatif jusqu'à 1 000 V à 50 Hz ou 60 Hz, avec des fréquences de fonctionnement différentes de la fréquence du réseau d'alimentation, associés aux lampes à fluorescence spécifiées dans la CEI 60081 et la CEI 60901, et à d'autres lampes à fluorescence fonctionnant à haute fréquence. Cette première édition de la CEI 61347-2-3, conjointement avec la CEI 61347-1, annule et remplace la deuxième édition de la CEI 60928, parue en 1995, dont elle constitue une révision mineure. Cette norme doit être utilisée conjointement avec la CEI 61347-1. Elle est établie sur la base de la première édition (2000) de cette norme.
General Information
Relations
Standards Content (Sample)
NORME CEI
INTERNATIONALE IEC
61347-2-3
INTERNATIONAL
Première édition
STANDARD
First edition
2000-10
Appareillages de lampes –
Partie 2-3:
Prescriptions particulières pour les ballasts
électroniques alimentés en courant alternatif
pour lampes fluorescentes
Lamp controlgear –
Part 2-3:
Particular requirements for a.c. supplied
electronic ballasts for fluorescent lamps
Numéro de référence
Reference number
CEI/IEC 61347-2-3:2000
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 J anuary 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de l a CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/catlg-f.htm) vous permet de faire des (www.iec.ch/catlg-e.htm) enables you to search
recherches en utilisant de nombreux critères, by a variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations line information is also available on recently
en ligne sont également disponibles sur les issued publications, withdrawn and replaced
nouvelles publications, les publications rempla- publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published
• IEC Just Published
Ce résumé des dernières publications parues
This summary of recently issued publications
(www.iec.ch/JP.htm) est aussi disponible par
(www.iec.ch/JP.htm) is also available by email.
courrier électronique. Veuillez prendre contact
Please contact the Customer Service Centre (see
avec le Service client (voir ci-dessous) pour plus
below) for further information.
d’informations.
• Service clients
• Customer Service Centre
Si vous avez des questions au s ujet de c ette
If you h ave any questions regarding this
publication ou avez besoin de renseignements
publication or need further assistance, please
supplémentaires, prenez contact avec le Service
contact the Customer Service Centre:
clients:
Email: custserv@iec.ch
Email: custserv@iec.ch
Tél: +41 22 919 02 11
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
61347-2-3
INTERNATIONAL
Première édition
STANDARD
First edition
2000-10
Appareillages de lampes –
Partie 2-3:
Prescriptions particulières pour les ballasts
électroniques alimentés en courant alternatif
pour lampes fluorescentes
Lamp controlgear –
Part 2-3:
Particular requirements for a.c. supplied
electronic ballasts for fluorescent lamps
IEC 2000 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
R
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61347-2-3 CEI:2000
SOMMAIRE
Pages
AVANT-PROPOS . 4
INTRODUCTION .8
Articles
1 Domaine d'application . 10
2 Références normatives. 10
3 Définitions. 10
4 Prescriptions générales . 12
5 Généralités sur les essais . 14
6 Classification .14
7 Marquage.14
7.1 Marquages obligatoires . 14
7.2 Informations devant être fournies, le cas échéant . 14
8 Protection contre les contacts accidentels avec des parties actives. 16
9 Bornes . 16
10 Dispositions en vue de la mise à la terre. 16
11 Résistance à l’humidité et isolement. 16
12 Rigidité diélectrique. 16
13 Essai d'endurance thermique des enroulements . 16
14 Conditions de défaut . 16
15 Protection des composants associés . 16
16 Conditions anormales. 18
17 Construction. 20
18 Lignes de fuite et distance dans l'air . 20
19 Vis, parties transportant le courant et connexions . 20
20 Résistance à la chaleur, au feu et aux courants de cheminement. 20
21 Résistance à la corrosion . 20
Annexes . 26
Figure 1 – Circuit pour l’essai de l’effet redresseur. 22
Figure 2 – Limites des courants efficaces de fuite capacitifs haute fréquence des lampes
tubulaires fluorescentes selon la durée . 24
Figure I.1 – Dispositif pour l’essai . 30
Tableau 1 – Relation entre la tension de fonctionnement efficace et la tension
de crête maximale . 18
Tableau J.1 – Impulsions de tension . 38
61347-2-3 IEC:2000 – 3 –
CONTENTS
Page
FOREWORD . 5
INTRODUCTION .9
Clause
1 Scope . 11
2 Normative references. 11
3 Definitions. 11
4 General requirements . 13
5 General notes on tests. 15
6 Classification .15
7 Marking. 15
7.1 Mandatory markings . 15
7.2 Information to be provided, if applicable. 15
8 Protection against accidental contact with live parts. 17
9 Terminals. 17
10 Provisions for earthing . 17
11 Moisture resistance and insulation . 17
12 Electric strength.17
13 Thermal endurance test for windings. 17
14 Fault conditions . 17
15 Protection of associated components . 17
16 Abnormal conditions . 19
17 Construction .21
18 Creepage distances and clearances. 21
19 Screws, current-carrying parts and connections . 21
20 Resistance to heat, fire and tracking . 21
21 Resistance to corrosion. 21
Annexes . 27
Figure 1 – Circuit for testing rectifying effect . 23
Figure 2 – Limits for capacitive leakage current in r.m.s. of HF-operated tubular fluorescent
lamps depending on duration . 25
Figure I.1 – Test arrangement . 31
Table 1 – Relation between r.m.s. working voltage and maximum peak voltage. 19
Table J.1 – Pulse voltages . 39
– 4 – 61347-2-3 CEI:2000
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
–––––––––––
APPAREILLAGES DE LAMPES –
Partie 2-3: Prescriptions particulières pour les ballasts électroniques
alimentés en courant alternatif pour lampes fluorescentes
AVANT-PROPOS
1) La CEI (Commission Électrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour obj et de
favoriser la coopération internationale pour t outes les questions de norm alisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CE I collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de rec ommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les Comités
nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de l a CEI et la norme nationale ou r égionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propri été intellectuelle ou de droi ts analogues. La CE I ne s aurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 61347-2-3 a été établie par le s ous-comité 34C: Appar eils
auxiliaires pour lampes, du comité d’études 34 de la CEI: Lampes et équipements associés.
Cette première édition de la CEI 61347- 2-3, conjointement avec la CEI 61347-1, annule et
remplace la deuxième édition de la CEI 60928, par ue en 1995, dont elle c onstitue une révision
mineure.
Cette norme doit être utilisée conjointement avec la CEI 61347-1. Elle est établie sur la base
de la première édition (2000) de cette norme.
La présente partie 2 complète ou modifie les articles correspondants de la CEI 61347- 1 de
façon à la transformer en norme CEI: Prescriptions particulières pour les ballasts électroniques
alimentés en courant alternatif pour lampes fluorescentes.
NOTE Dans la présente norme, les caractères suivants sont employés:
– Prescriptions proprement dites: caractères romains.
– Modalités d'essais: caractères italiques.
– Notes: petits caractères romains.
61347-2-3 IEC:2000 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
–––––––––––
LAMP CONTROLGEAR –
Part 2-3: Particular requirements for a.c. supplied electronic ballasts
for fluorescent lamps
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The o bject of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end a nd in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any I EC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on t echnical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or g uides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61347-2-3 has been prepared by subcommittee 34C: Auxiliaries
for lamps, of IEC technical committee 34: Lamps and related equipment.
This first edition of IEC 61347-2-3, together with IEC 61347-1, cancels and replaces the
second edition of IEC 60928, published in 1995, and constitutes a minor revision.
This standard shall be used in conjunction with IEC 61347-1. It was established on the basis
of the first edition (2000) of that standard.
This part 2 s upplements or modifies the corresponding clauses in IEC 61347-1 so as to
convert that publication into the IEC standard: Particular requirements for a.c. supplied
electronic ballasts for fluorescent lamps.
NOTE In this standard, the following print types are used:
– Requirements proper: in roman type.
– Test specifications: in italic type.
– Explanatory matter: in smaller roman type.
– 6 – 61347-2-3 CEI:2000
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
34C/500/FDIS 34C/514/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 3.
Les annexes A à J font partie intégrante de la présente norme.
La CEI 61347 comprend les parties suivantes, présentées sous le titre général Appareillages
de lampes
:
– Partie 1: Prescriptions générales et prescriptions de sécurité
– Partie 2-1: Prescriptions particulières pour les dispositifs d'amorçage (autres que starters à
)
lueur
– Partie 2-2: Prescriptions particulières pour les convertisseurs abaisseurs électroniques
alimentés en courant continu ou alternatif pour lampes à incandescence
– Partie 2-3: Prescriptions particulières pour les ballasts électroniques alimentés en courant
alternatif pour lampes fluorescentes
– Partie 2-4: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage général
– Partie 2-5: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage des transports en commun
– Partie 2-6: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage des aéronefs
– Partie 2-7: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage de secours
– Partie 2-8: Prescriptions particulières pour les ballasts pour lampes fluorescentes
– Partie 2-9: Prescriptions particulières pour les ballasts pour lampes à décharge (à
l'exclusion des lampes fluorescentes)
– Partie 2-10: Prescriptions particulières pour les onduleurs et les convertisseurs
électroniques destinés à l’alimentation en haute f réquence des lampes tubulaires à
décharge à démarrage à froid (tubes néon)
– Partie 2-11: Prescriptions particulières pour les circuits électroniques divers pour usage
1)
avec les luminaires
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2003. A cette
date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
–––––––––
1)
A publier.
61347-2-3 IEC:2000 – 7 –
The text of this standard is based on the following documents:
FDIS Report on voting
34C/500/FDIS 34C/514/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
Annexes A to J form an integral part of this standard.
IEC 61347 consists of the following parts, under the general title Lamp controlgear:
– Part 1: General and safety requirements
)
– Part 2-1: Particular requirements for starting devices (other than glow starters
– Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors
for filament lamps
– Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps
– Part 2-4: Particular requirements for d.c. electronic ballasts for general lighting
– Part 2-5: Particular requirements for d.c. supplied electronic ballasts for public transport
lighting
– Part 2-6: Particular requirements for d.c. supplied electronic ballasts for aircraft lighting
– Part 2-7: Particular requirements for d.c. supplied electronic ballasts for emergency
lighting
– Part 2-8: Particular requirements for ballasts for fluorescent lamps
– Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent
lamps)
– Part 2-10: Particular requirements for electronic invertors and convertors for high-
frequency operation of cold start tubular discharge lamps (neon tubes)
– Part 2-11: Particular requirements for miscellaneous electronic circuits used with
1)
luminaires
The committee has decided that the contents of this publication will remain unchanged until
2003. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
––––––––––
1)
To be published.
– 8 – 61347-2-3 CEI:2000
INTRODUCTION
Cette première édition de la CEI 61347-2-3, publiée conjointement avec la CEI 61347-1,
constitue une modification éditoriale de la CEI 60928. La pr ésentation en par ties publiées
séparément facilitera les futures modifications et révisions. Des prescriptions supplémentaires
seront ajoutées si et quand le besoin en sera reconnu.
La présente norme, et les parties qui composent la CEI 61347- 2, en faisant référence à un
quelconque des articles de la CEI 61347- 1, spécifient le domaine dans lequel cet article est
applicable et l'or dre dans lequel les essais sont à effectuer; elles incluent aussi des
prescriptions supplémentaires, si nécessaire. Toutes les parties composant la CEI 61347- 2
sont considérés comme autonomes et, par conséquent, ne contiennent pas de références les
unes aux autres. Cependant, dans le c as des appareillages de lampe pour l'éclairage de
secours, certaines références croisées ont été nécessaires.
Quand les prescriptions de l'un quelc onque des articles de la CEI 61347-1 sont citées en
référence dans la pr ésente norme par la phr ase «Les prescriptions de l'ar ticle n de la
CEI 61347-1 s'appliquent», cette phrase s'interprète comme signifiant que toutes les
prescriptions de cet article de la par tie 1 s'appliquent, excepté celles qui d' évidence ne
s'appliquent pas au type particulier d'appareillage de lam pe considéré dans cette partie
spécifique de la CEI 61347-2.
61347-2-3 IEC:2000 – 9 –
INTRODUCTION
This first edition of IEC 61347-2-3, published in conjunction with IEC 61347-1, represents an
editorial review of IEC 60928. The formatting into separately published parts provides for
ease of future amendments and revisions. Additional requirements will be added as and when
a need for them is recognized.
This standard, and the parts which make up IEC 61347-2, in referring to any of the clauses of
IEC 61347-1, specify the extent to which such a clause is applicable and the order in which
the tests are to be performed; they also include additional requirements, as necessary. All
parts which make up IEC 61347-2 are intended to be self-contained and, therefore, do not
include references to each other. However, for the case of emergency lighting lamp
controlgear, some cross-referencing has been necessary.
Where the requirements of any of the clauses of IEC 61347-1 are referred to in this standard
by the phrase ”The requirements of clause n of IEC 61347-1 apply”, this phrase is interpreted
as meaning that all requirements of the clause in question of part 1 apply, except any which
are clearly inapplicable to the specific type of lamp controlgear covered by this particular part
of IEC 61347-2.
– 10 – 61347-2-3 CEI:2000
APPAREILLAGES DE LAMPES –
Partie 2-3: Prescriptions particulières pour les ballasts électroniques
alimentés en courant alternatif pour lampes fluorescentes
1 Domaine d'application
La présente partie de la CEI 61347 spécifie les prescriptions particulières de sécurité
applicables aux ballasts électroniques pour utilisation en courant alternatif jusqu'à 1 000 V à
50 Hz ou 60 Hz, avec des fréquences de fonctionnement différentes de la fréquence du réseau
d'alimentation, associés aux lampes à fluorescence spécifiées dans la CEI 60081 et la
CEI 60901, et à d'autres lampes à fluorescence fonctionnant à haute fréquence.
Des prescriptions particulières pour les ballasts électroniques avec dispositifs de protection
contre la surchauffe sont données à l’annexe C.
Des prescriptions particulières pour les ballasts électroniques alimentés en courant continu ou
alternatif, destinés à l'éclairage de secours, sont données à l'annexe J.
Les prescriptions de performances font l’objet de la CEI 60929.
2 Références normatives
Pour les besoins de la pr ésente partie de la CEI 61347, les références normatives données à
l’article 2 de la CEI 61347-1 et qui s ont mentionnées dans la pr ésente norme s’appliquent,
conjointement avec les références normatives suivantes.
CEI 60598-2-22, Luminaires – Partie 2-22: Règles particulières – Luminaires pour éclairage de
secours
CEI 61347-1, Appareillages de lampes – Partie 1: Prescriptions générales et prescriptions de
sécurité
CEI 61347-2-7, Appareillages des lampes – Partie 2-7: Prescriptions particulières pour les
1)
ballasts électroniques alimentés en courant continu pour l'éclairage de secours
3 Définitions
Pour les besoins de la pr ésente partie de la CEI 61347, les définitions de l'article 3 de la
CEI 61347-1 s'appliquent, avec les suivantes:
3.1
ballast électronique alimenté en courant alternatif
onduleur alimenté en c ourant alternatif par le réseau, fournissant une tens ion alternative
généralement de haute f réquence et comportant des éléments de s tabilisation nécessaires
pour l'amorçage et le fonctionnement d'une ou de plusieurs lampes à fluorescence
–––––––––
1)
A publier.
61347-2-3 IEC:2000 – 11 –
LAMP CONTROLGEAR –
Part 2-3: Particular requirements for a.c. supplied electronic ballasts
for fluorescent lamps
1 Scope
This part of IEC 61347 specifies particular safety requirements for electronic ballasts for use
on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the
supply frequency, associated with fluorescent lamps as specified in IEC 60081 and
IEC 60901, and other fluorescent lamps for high-frequency operation.
Particular requirements for electronic ballasts with means of protection against overheating
are given in annex C.
Particular requirements for a.c./d.c. supplied electronic ballasts for maintained emergency
lighting are given in annex J.
Performance requirements are the subject of IEC 60929.
2 Normative references
For the purpose of this part of IEC 61347, the normative references given in clause 2 of
IEC 61347-1 which are mentioned in this standard apply, together with the following normative
references.
IEC 60598-2-22, Luminaires – Part 2-22: Particular requirements – Luminaires for emergency
lighting
IEC 61347-1, Lamp controlgear – Part 1: General and safety requirements
IEC 61347-2-7, Lamp controlgear – Part 2-7: Particular requirements for d.c. supplied
1)
electronic ballasts for emergency lighting
3 Definitions
For the purpose of this part of IEC 61347, the definitions of clause 3 of IEC 61347-1 apply,
together with the following:
3.1
a.c. supplied electronic ballast
mains-supplied a.c. to a.c. invertor including stabilizing elements for starting and operating
one or more tubular fluorescent lamps, generally at high frequency
––––––––––
1)
To be published.
– 12 – 61347-2-3 CEI:2000
3.2
ballast à gradation
la puissance de la lampe (flux lumineux) du ballast électronique commandée entre les valeurs
minimale (ou nulle) et maximale par un signal appliqué à l'entrée de commande du ballast
3.3
valeur maximale de la puissance de lampe (d'un ballast à gradation)
puissance de lampe (flux lumineux) qui est conforme à 8.1 de la CEI 60929, sauf déclaration
différente du fabricant ou du vendeur responsable
3.4
tension de crête maximale autorisée
la plus haute tension de c rête permise au travers de n’importe quel isolant en condition de
circuit ouvert et dans n’importe quelle condition de fonctionnement normale ou anormale. La
tension de c rête maximale est liée à la tens ion efficace de f onctionnement déclarée; voir
tableau 1.
3.5
valeur minimale de la puissance de lampe (d'un ballast à gradation)
pourcentage le plus bas de la puissance de lampe définie en 3.3 déclaré par le fabricant ou le
vendeur responsable
3.6
bornes de réglage
connexions au ballast électronique qui sont utilisées pour appliquer un signal de r églage afin
de modifier le flux lumineux
NOTE Les bornes de l'alimentation peuvent également agir comme bornes de réglage.
3.7
signal de réglage
signal qui peut être une tension alternative ou continue et qui peut être modulé de manière
analogique, digitale ou autre pour transmettre l'information nécessaire au ballast dans le but de
modifier le flux lumineux
3.8
ballasts électroniques alimentés en courant alternatif ou continu destinés à l'éclairage
de secours de type permanent
onduleur alimenté en courant alternatif par le r éseau ou en c ontinu par batteries, fournissant
une tension alternative généralement de haute fréquence et c omportant des éléments de
stabilisation nécessaires pour l'amorçage et le fonctionnement d'une ou de plus ieurs lampes à
fluorescence pour l’éclairage de secours
3.9
résistance de substitution de cathode
résistance de s ubstitution de cathode comme spécifié sur la f euille de c aractéristiques de
lampe appropriée de la CEI 60081 ou de la CEI 60901 ou comme déclaré par le fabricant de
lampe concerné ou le vendeur responsable
4 Prescriptions générales
Les prescriptions de l ’article 4 de la CEI 61347-1 s’appliquent, avec l’adjonction de la
prescription suivante:
Les ballasts électroniques alimentés en courant alternatif ou continu destinés à l'éclairage de
secours doivent satisfaire aux prescriptions de l’annexe J.
61347-2-3 IEC:2000 – 13 –
3.2
controllable ballast
lamp power (light output) of the electronic ballast controlled between the minimum value (or
off) and the maximum value by the signal on the control input of the ballast
3.3
maximum value of lamp power (of a controllable ballast)
lamp power (light output) which complies with 8.1 of IEC 60929, unless otherwise declared by
the manufacturer or responsible vendor
3.4
maximum allowed peak voltage
highest permitted peak voltage across any insulation under open-circuit condition and any
normal and abnormal operating conditions. The maximum peak voltage is related to the
declared r.m.s. working voltage; see table 1
3.5
minimum value of lamp power (of a controllable ballast)
lowest percentage of the lamp power defined in 3.3 declared by the manufacturer or
responsible vendor
3.6
control terminals
connections to the electronic ballast which are used to apply a control signal for changing the
light output
NOTE The power supply terminals can also act as control terminals.
3.7
control signal
signal which may be an a.c. or d.c. voltage, and which by analogue, digital or other means
may be modulated to convey the necessary information to the ballast for the purpose of
changing the light output
3.8
a.c./d.c. supplied electronic ballast for maintained emergency lighting
mains/battery-supplied a.c./d.c to a.c. invertor including stabilizing elements for starting and
operating one or more tubular fluorescent lamps, generally at high frequency for emergency
lighting
3.9
cathode dummy resistor
cathode substitution resistor as specified on the relevant lamp data sheet of IEC 60081 or
IEC 60901 or as declared by the relevant lamp manufacturer or by the responsible vendor
4 General requirements
The requirements of clause 4 of IEC 61347-1 apply, together with the following additional
requirement:
AC/d.c. electronic ballasts for emergency lighting shall comply with the requirements of
annex J.
– 14 – 61347-2-3 CEI:2000
5 Généralités sur les essais
Les prescriptions de l'article 5 de la CEI 61347- 1 s'appliquent, avec l'adjonction de la
prescription suivante:
Nombre de spécimens
Le nombre suivant de spécimens doit être soumis pour les essais:
– une unité pour les essais des articles 6 à 12 et 15 à 21;
– une unité pour les essais de l ’article 14 (des unités supplémentaires ou des composants
peuvent être demandés, si nécessaire, après consultation du fabricant).
Les essais pour satisfaire aux prescriptions de s écurité pour les ballasts électroniques
alimentés en courant alternatif ou continu destinés à l'éclairage de secours sont effectués dans
les conditions spécifiées à l’annexe J.
6 Classification
Les prescriptions de l'article 6 de la CEI 61347-1 s'appliquent.
7 Marquage
Les ballasts qui forment une partie intégrée dans le luminaire n’ont pas besoin d’être marqués.
7.1 Marquages obligatoires
Les ballasts autres que les ballasts intégrés doivent être marqués d’une manière claire et
durable, en conformité avec les prescriptions de 7.2 de la CEI 61347-1, avec les marquages
obligatoires suivants:
– points a), b), c), d), e), l) et k) de 7.1 de la CEI 61347-1, conjointement avec
– le symbole de mise à la terre, le cas échéant;
– pour les ballasts à gradation, les bornes de commande doivent être identifiées;
– une déclaration de la tension maximale de fonctionnement (efficace) selon 12.2 entre
– les bornes de sortie;
– n’importe quelle borne de sortie et la terre, si cela est applicable.
Le marquage pour chacune de ces deux valeurs doit être effectué par multiples de 10 V quand
la tension de fonctionnement est inférieure ou égale à 500 V, et par multiples de 50 V quand la
tension de fonctionnement est supérieure à 500 V. Le marquage de la tens ion maximale de
fonctionnement se fait dans deux cas, le maximum entre bornes de sortie et le maximum entre
une borne de sortie quelconque et la terre. Il est acceptable que seule la valeur la plus haute
soit marquée.
Le marquage doit être U-OUT = .V.
7.2 Informations devant être fournies, le cas échéant
En plus des marquages obligatoires ci-dessus, les informations suivantes doivent, le cas
échéant, être données soit sur le ballast, soit sur le catalogue du fabricant ou un doc ument
équivalent:
– points h), i) et j) de 7.1 de la CEI 61347-1.
61347-2-3 IEC:2000 – 15 –
5 General notes on tests
The requirements of clause 5 of 61347-1 apply together with the following additional
requirement:
Number of specimens
The following number of specimens shall be submitted for testing:
– one unit for the tests of clause 6 to 12 and 15 to 21;
– one unit for the test of clause 14 (additional units or components, where necessary, may
be required in consultation with the manufacturer).
Tests to meet the safety requirements for a.c./d.c. supplied electronic ballasts for emergency
lighting are made under the conditions specified in annex J.
6 Classification
The requirements of clause 6 of IEC 61347-1 apply.
7 Marking
Ballasts which form an integral part of the luminaire need not be marked.
7.1 Mandatory markings
In accordance with the requirements of 7.2 of IEC 61347-1, ballasts, other than integral
ballasts, shall be clearly and durably marked with the following mandatory markings:
– items a), b), c), d), e), l) and k) of 7.1 of IEC 61347-1, together with
– the symbol for earthing, as applicable;
– for controllable ballasts, the control terminals shall be identified;
– a declaration of the maximum working voltage (r.m.s.) according to 12.2 between
– output terminals;
– any output terminal and earth, if applicable.
Marking for each of these two values shall be in steps of 10 V when the working voltage is
equal to, or less than, 500 V, and in steps of 50 V when the working voltage is higher than
500 V. The marking of maximum working voltage is referenced in two situations, the maximum
between output terminals and the maximum between any output terminal and earth. It is
acceptable for only the higher of these two voltages to be marked.
Marking shall be U-OUT=.V.
7.2 Information to be provided, if applicable
In addition to the above mandatory markings, the following information, if applicable, shall be
given either on the ballast, or be made available in the manufacturer’s catalogue or similar:
– items h), i), and j) given in 7.1 of IEC 61347-1.
– 16 – 61347-2-3 CEI:2000
8 Protection contre les contacts accidentels avec des parties actives
Les prescriptions de l'article 10 de la CEI 61347-1 s'appliquent.
9 Bornes
Les prescriptions de l'article 8 de la CEI 61347-1 s'appliquent.
10 Dispositions en vue de la mise à la terre
Les prescriptions de l'article 9 de la CEI 61347-1 s'appliquent.
11 Résistance à l’humidité et isolement
Les prescriptions de l'ar ticle 11 de la CEI 61347- 1 s'appliquent avec l'adjonction des
prescriptions suivantes:
Le courant de fuite qui peut s e produire à partir d’un contact avec une lampe fluorescente
fonctionnement en haute f réquence à partir d’un ballast électronique alimenté en c ourant
alternatif ne doit pas dépasser les valeurs de la f igure 2 quand il es t mesuré conformément à
l’annexe I. Les valeurs sont des valeurs efficaces.
Les limites des valeurs des courants de fuite pour des fréquences comprises entre les valeurs
portées sur la figure 2 doivent être déterminées par calcul selon la formule de la f igure (à
l’étude).
NOTE Les limites des valeurs du courant de fuite pour des fréquences supérieures à 50 Hz sont à l’étude.
La conformité avec ces prescriptions est vérifiée conformément à l’annexe I.
12 Rigidité diélectrique
Les prescriptions de l'article 12 de la CEI 61347-1 s'appliquent.
13 Essai d'endurance thermique des enroulements
Les prescriptions de l'article 13 de la CEI 61347-1 ne s'appliquent pas.
14 Conditions de défaut
Les prescriptions de l'article 14 de la CEI 61347-1 s'appliquent.
15 Protection des composants associés
15.1
Dans les conditions de fonctionnement normales, vérifiées à l’aide des résistances de cathode
de substitution et dans les conditions de f onctionnement anormales, comme spécifié à
l’article 16, la tens ion aux bornes de s ortie ne doit j amais dépasser la valeur maximale
autorisée de la tension de crête spécifiée au tableau 1.
61347-2-3 IEC:2000 – 17 –
8 Protection against accidental contact with live parts
The requirements of clause 10 of IEC 61347-1 apply.
9 Terminals
The requirements of clause 8 of IEC 61347-1 apply.
10 Provisions for earthing
The requirements of clause 9 of IEC 61347-1 apply.
11 Moisture resistance and insulation
The requirements of clause 11 of IEC 61347-1 apply together with the following additional
requirements:
The leakage current that may occur from contact with fluorescent lamps operated at high
frequency from a.c. supplied electronic ballasts shall not exceed the values in figure 2 when
measured in accordance with annex I. The values are in r.m.s. values.
The limits of leakage current values for frequencies between the values shown in figure 2
should be obtained by calculation according to the formula in the figure (under consideration).
NOTE Limits of leakage current values for frequencies above 50 Hz are under consideration.
Compliance with these requirements is checked in accordance with annex I.
12 Electric strength
The requirements of clause 12 of IEC 61347-1 apply.
13 Thermal endurance test for windings
The requirements of clause 13 of IEC 61347-1 do not apply.
14 Fault conditions
The requirements of clause 14 of IEC 61347-1 apply.
15 Protection of associated components
15.1
Under conditions of normal operation, verified with dummy cathode resistors inserted and
conditions of abnormal operation, as specified in clause 16, the voltage at the output
terminals shall at no time exceed the maximum permitted peak value specified in table 1.
– 18 – 61347-2-3 CEI:2000
Tableau 1 – Relation entre la tension de fonctionnement efficace
et la tension de crête maximale
Tension aux bornes de sortie
Tension de fonctionnement efficace Tension de crête maximale autorisée
V V
250 2 200
500 2 900
750 3 100
1 000 3 200
NOTE L’interpolation linéaire entre les valeurs de tension données est autorisée.
15.2
Dans les conditions de fonctionnement normales et dans les conditions de fonctionnement
anormales, comme cela est spécifié à l’article 15, à l’exception de l’effet redresseur, et à
...
NORME CEI
INTERNATIONALE
IEC
61347-2-3
INTERNATIONAL
Edition 1.1
STANDARD
2004-09
Edition 1:2000 consolidée par l'amendement 1:2004
Edition 1:2000 consolidated with amendment 1:2004
Appareillages de lampes –
Partie 2-3:
Prescriptions particulières pour les ballasts
électroniques alimentés en courant alternatif
pour lampes fluorescentes
Lamp controlgear –
Part 2-3:
Particular requirements for a.c. supplied
electronic ballasts for fluorescent lamps
Numéro de référence
Reference number
CEI/IEC 61347-2-3:2000+A1:2004
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
x Site web de la CEI (www.iec.ch) x IEC Web Site (www.iec.ch)
x Catalogue des publications de la CEI x Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
x IEC Just Published x IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
x Service clients x Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE
IEC
INTERNATIONAL 61347-2-3
STANDARD Edition 1.1
2004-09
Edition 1:2000 consolidée par l'amendement 1:2004
Edition 1:2000 consolidated with amendment 1:2004
Appareillages de lampes –
Partie 2-3:
Prescriptions particulières pour les ballasts
électroniques alimentés en courant alternatif
pour lampes fluorescentes
Lamp controlgear –
Part 2-3:
Particular requirements for a.c. supplied
electronic ballasts for fluorescent lamps
© IEC 2004 Droits de reproduction réservés ⎯ Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
CJ
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
ɆɟɠɞɭɧɚɪɨɞɧɚɹɗɥɟɤɬɪɨɬɟɯɧɢɱɟɫɤɚɹɄɨɦɢɫɫɢɹ
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61347-2-3 ¤ CEI:2000+A1:2004
SOMMAIRE
AVANT-PROPOS .6
INTRODUCTION.10
1 Domaine d'application.12
2 Références normatives .12
3 Définitions .12
4 Prescriptions générales .14
5 Généralités sur les essais.16
6 Classification .16
7 Marquage .16
7.1 Marquages obligatoires.16
7.2 Informations devant être fournies, le cas échéant.16
8 Protection contre les contacts accidentels avec des parties actives .18
9 Bornes.18
10 Dispositions en vue de la mise à la terre .18
11 Résistance à l’humidité et isolement .18
12 Rigidité diélectrique .18
13 Essai d'endurance thermique des enroulements.18
14 Conditions de défaut.18
15 Protection des composants associés.18
16 Conditions anormales .20
17 Comportement du ballast en fin de vie de lampe .22
17.1 Effets de fin de vie de la lampe .22
17.2 Essai aux impulsions, mode asymétrique .24
17.3 Essai en puissance dissipée, mode asymétrique .28
17.4 Essai filament coupé.30
18 Construction .38
19 Lignes de fuite et distance dans l'air .38
20 Vis, parties transportant le courant et connexions.38
21 Résistance à la chaleur, au feu et aux courants de cheminement .38
22 Résistance à la corrosion.38
Annexes.44
Figure 1a – Circuit pour l’essai .40
Figure 1b – Temps de recouvrement t de la diode .40
rr
Figure 1 – Essai de l’effet redresseur .40
Figure 2 – Limites des courants efficaces de fuite capacitifs haute fréquence
des lampes tubulaires fluorescentes selon la durée .42
Figure 3 – Circuit d’essai aux impulsions, mode asymétrique.26
Figure 4 – Circuit d’essai en puissance dissipée, mode asymétrique.30
61347-2-3 ¤ IEC:2000+A1:2004 – 3 –
CONTENTS
FOREWORD.7
INTRODUCTION.11
1 Scope.13
2 Normative references .13
3 Definitions .13
4 General requirements .15
5 General notes on tests .17
6 Classification.17
7 Marking .17
7.1 Mandatory markings .17
7.2 Information to be provided, if applicable .17
8 Protection against accidental contact with live parts .19
9 Terminals .19
10 Provisions for earthing.19
11 Moisture resistance and insulation.19
12 Electric strength .19
13 Thermal endurance test for windings .19
14 Fault conditions .19
15 Protection of associated components .19
16 Abnormal conditions .21
17 Behaviour of the ballast at end of lamp life .23
17.1 End of lamp life effects.23
17.2 Asymmetric pulse test .25
17.3 Asymmetric power test .29
17.4 Open filament test .31
18 Construction .39
19 Creepage distances and clearances .39
20 Screws, current-carrying parts and connections.39
21 Resistance to heat, fire and tracking.39
22 Resistance to corrosion .39
Annexes .45
Figure 1a – Circuit for testing.41
Figure 1b – Recovery time t of the diode .41
rr
Figure 1 – Rectifying effect test .41
Figure 2 – Limits for capacitive leakage current in r.m.s.
of HF-operated tubular fluorescent lamps depending on duration.43
Figure 3 – Asymmetric pulse test circuit.27
Figure 4 – Asymmetric power detection circuit .31
– 4 – 61347-2-3 ¤ CEI:2000+A1:2004
Figure 5a – Circuit d'essai pour filament coupé; vérification de l'électrode (1) .36
Figure 5b – Circuit d'essai pour filament coupé; vérification de l'électrode (2) .36
Figure 5c – Détection du courant de lampe.36
Figure 5 – Circuits d'essai pour filament coupé.36
Figure I.1 – Dispositif pour l’essai.48
Tableau 1 – Relation entre la tension de fonctionnement efficace
et la tension de crête maximale .20
Tableau J.1 – Impulsions de tension.56
Tableau K.1 – Spécification du matériel.58
Tableau K.2 – Spécification du transformateur.58
61347-2-3 ¤ IEC:2000+A1:2004 – 5 –
Figure 5a – Open filament test circuit; electrode (1) check.37
Figure 5b – Open filament test circuit; electrode (2) check.37
Figure 5c – Detection of lamp current .37
Figure 5 – Open filament test circuits.37
Figure I.1 – Test arrangement.49
Table 1 – Relation between r.m.s. working voltage and maximum peak voltage .21
Table J.1 – Pulse voltages.57
Table K.1 – Material specification .59
Table K.2 – Transformer specification.59
– 6 – 61347-2-3 ¤ CEI:2000+A1:2004
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
APPAREILLAGES DE LAMPES –
Partie 2-3: Prescriptions particulières pour les ballasts électroniques
alimentés en courant alternatif pour lampes fluorescentes
AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes internationales,
des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au public (PAS) et des
Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des comités d'études,
aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les organisations
internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent également aux
travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO), selon des
conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable de
l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 61347-2-3 a été établie par le sous-comité 34C: Appareils
auxiliaires pour lampes, du comité d’études 34 de la CEI: Lampes et équipements associés.
Cette norme doit être utilisée conjointement avec la CEI 61347-1. Elle est établie sur la base
de la première édition (2000) de cette norme.
La présente partie 2 complète ou modifie les articles correspondants de la CEI 61347-1 de
façon à la transformer en norme CEI: Prescriptions particulières pour les ballasts électroniques
alimentés en courant alternatif pour lampes fluorescentes.
NOTE Dans la présente norme, les caractères suivants sont employés:
– Prescriptions proprement dites: caractères romains.
– Modalités d'essais: caractères italiques.
– Notes: petits caractères romains.
61347-2-3 ¤ IEC:2000+A1:2004 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
LAMP CONTROLGEAR –
Part 2-3: Particular requirements for a.c. supplied electronic ballasts
for fluorescent lamps
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61347-2-3 has been prepared by subcommittee 34C: Auxiliaries
for lamps, of IEC technical committee 34: Lamps and related equipment.
This standard shall be used in conjunction with IEC 61347-1. It was established on the basis
of the first edition (2000) of that standard.
This part 2 supplements or modifies the corresponding clauses in IEC 61347-1 so as to
convert that publication into the IEC standard: Particular requirements for a.c. supplied
electronic ballasts for fluorescent lamps.
NOTE In this standard, the following print types are used:
– Requirements proper: in roman type.
– Test specifications: in italic type.
– Explanatory matter: in smaller roman type.
– 8 – 61347-2-3 ¤ CEI:2000+A1:2004
La présente version consolidée de la CEI 61347-2-3 comprend la première édition (2000)
[documents 34C/500/FDIS et 34C/514/RVD] et son amendement 1 (2004) [documents
34C/636/FDIS et 34C/644/RVD].
Le contenu technique de cette version consolidée est donc identique à celui de l'édition de
base et à son amendement; cette version a été préparée par commodité pour l'utilisateur.
Elle porte le numéro d'édition 1.1.
Une ligne verticale dans la marge indique où la publication de base a été modifiée par
l'amendement 1.
Les annexes A à J font partie intégrante de la présente norme.
L'annexe K est donnée uniquement à titre d'information.
La CEI 61347 comprend les parties suivantes, présentées sous le titre général Appareillages
de lampes:
– Partie 1: Prescriptions générales et prescriptions de sécurité
– Partie 2-1: Prescriptions particulières pour les dispositifs d'amorçage (autres que starters à
)
lueur
– Partie 2-2: Prescriptions particulières pour les convertisseurs abaisseurs électroniques
alimentés en courant continu ou alternatif pour lampes à incandescence
– Partie 2-3: Prescriptions particulières pour les ballasts électroniques alimentés en courant
alternatif pour lampes fluorescentes
– Partie 2-4: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage général
– Partie 2-5: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage des transports en commun
– Partie 2-6: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage des aéronefs
– Partie 2-7: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage de secours
– Partie 2-8: Prescriptions particulières pour les ballasts pour lampes fluorescentes
– Partie 2-9: Prescriptions particulières pour les ballasts pour lampes à décharge (à
l'exclusion des lampes fluorescentes)
– Partie 2-10: Prescriptions particulières pour les onduleurs et les convertisseurs
électroniques destinés à l’alimentation en haute fréquence des lampes tubulaires à
décharge à démarrage à froid (tubes néon)
– Partie 2-11: Prescriptions particulières pour les circuits électroniques divers pour usage
1)
avec les luminaires
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de
maintenance indiquée sur le site web de la CEI sous "http://webstore.iec.ch" dans les données
relatives à la publication recherchée. A cette date, la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
–––––––––
1)
A publier.
61347-2-3 ¤ IEC:2000+A1:2004 – 9 –
This consolidated version of IEC 61347-2-3 consists of the first edition (2000) [documents
34C/500/FDIS and 34C/514/RVD] and its amendment 1 (2004) [documents 34C/636/FDIS and
34C/644/RVD].
The technical content is therefore identical to the base edition and its amendment and has
been prepared for user convenience.
It bears the edition number 1.1.
A vertical line in the margin shows where the base publication has been modified by
amendment 1.
Annexes A to J form an integral part of this standard.
Annex K is for information only.
IEC 61347 consists of the following parts, under the general title Lamp controlgear:
– Part 1: General and safety requirements
)
– Part 2-1: Particular requirements for starting devices (other than glow starters
– Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors
for filament lamps
– Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps
– Part 2-4: Particular requirements for d.c. electronic ballasts for general lighting
– Part 2-5: Particular requirements for d.c. supplied electronic ballasts for public transport
lighting
– Part 2-6: Particular requirements for d.c. supplied electronic ballasts for aircraft lighting
– Part 2-7: Particular requirements for d.c. supplied electronic ballasts for emergency
lighting
– Part 2-8: Particular requirements for ballasts for fluorescent lamps
– Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent
lamps)
– Part 2-10: Particular requirements for electronic invertors and convertors for high-
frequency operation of cold start tubular discharge lamps (neon tubes)
– Part 2-11: Particular requirements for miscellaneous electronic circuits used with
1)
luminaires
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
––––––––––
1)
To be published.
– 10 – 61347-2-3 ¤ CEI:2000+A1:2004
INTRODUCTION
Cette première édition de la CEI 61347-2-3, publiée conjointement avec la CEI 61347-1,
constitue une modification éditoriale de la CEI 60928. La présentation en parties publiées
séparément facilitera les futures modifications et révisions. Des prescriptions supplémentaires
seront ajoutées si et quand le besoin en sera reconnu.
La présente norme, et les parties qui composent la CEI 61347-2, en faisant référence à un
quelconque des articles de la CEI 61347-1, spécifient le domaine dans lequel cet article est
applicable et l'ordre dans lequel les essais sont à effectuer; elles incluent aussi des
prescriptions supplémentaires, si nécessaire. Toutes les parties composant la CEI 61347-2
sont considérés comme autonomes et, par conséquent, ne contiennent pas de références les
unes aux autres. Cependant, dans le cas des appareillages de lampe pour l'éclairage de
secours, certaines références croisées ont été nécessaires.
Quand les prescriptions de l'un quelconque des articles de la CEI 61347-1 sont citées en
référence dans la présente norme par la phrase «Les prescriptions de l'article n de la
CEI 61347-1 s'appliquent», cette phrase s'interprète comme signifiant que toutes les
prescriptions de cet article de la partie 1 s'appliquent, excepté celles qui d'évidence ne
s'appliquent pas au type particulier d'appareillage de lampe considéré dans cette partie
spécifique de la CEI 61347-2.
61347-2-3 ¤ IEC:2000+A1:2004 – 11 –
INTRODUCTION
This first edition of IEC 61347-2-3, published in conjunction with IEC 61347-1, represents an
editorial review of IEC 60928. The formatting into separately published parts provides for
ease of future amendments and revisions. Additional requirements will be added as and when
a need for them is recognized.
This standard, and the parts which make up IEC 61347-2, in referring to any of the clauses of
IEC 61347-1, specify the extent to which such a clause is applicable and the order in which
the tests are to be performed; they also include additional requirements, as necessary. All
parts which make up IEC 61347-2 are intended to be self-contained and, therefore, do not
include references to each other. However, for the case of emergency lighting lamp
controlgear, some cross-referencing has been necessary.
Where the requirements of any of the clauses of IEC 61347-1 are referred to in this standard
by the phrase ”The requirements of clause n of IEC 61347-1 apply”, this phrase is interpreted
as meaning that all requirements of the clause in question of part 1 apply, except any which
are clearly inapplicable to the specific type of lamp controlgear covered by this particular part
of IEC 61347-2.
– 12 – 61347-2-3 ¤ CEI:2000+A1:2004
APPAREILLAGES DE LAMPES –
Partie 2-3: Prescriptions particulières pour les ballasts électroniques
alimentés en courant alternatif pour lampes fluorescentes
1 Domaine d'application
La présente partie de la CEI 61347 spécifie les prescriptions particulières de sécurité
applicables aux ballasts électroniques pour utilisation en courant alternatif jusqu'à 1 000 V à
50 Hz ou 60 Hz, avec des fréquences de fonctionnement différentes de la fréquence du réseau
d'alimentation, associés aux lampes à fluorescence spécifiées dans la CEI 60081 et la
CEI 60901, et à d'autres lampes à fluorescence fonctionnant à haute fréquence.
Des prescriptions particulières pour les ballasts électroniques avec dispositifs de protection
contre la surchauffe sont données à l’annexe C.
Des prescriptions particulières pour les ballasts électroniques alimentés en courant continu ou
alternatif, destinés à l'éclairage de secours, sont données à l'annexe J.
Les prescriptions de performances font l’objet de la CEI 60929.
2 Références normatives
Pour les besoins de la présente partie de la CEI 61347, les références normatives données à
l’article 2 de la CEI 61347-1 et qui sont mentionnées dans la présente norme s’appliquent,
conjointement avec les références normatives suivantes.
CEI 60598-2-22, Luminaires – Partie 2-22: Règles particulières – Luminaires pour éclairage de
secours
CEI 61347-1, Appareillages de lampes – Partie 1: Prescriptions générales et prescriptions de
sécurité
CEI 61347-2-7, Appareillages des lampes – Partie 2-7: Prescriptions particulières pour les
1)
ballasts électroniques alimentés en courant continu pour l'éclairage de secours
3 Définitions
Pour les besoins de la présente partie de la CEI 61347, les définitions de l'article 3 de la
CEI 61347-1 s'appliquent, avec les suivantes:
3.1
ballast électronique alimenté en courant alternatif
onduleur alimenté en courant alternatif par le réseau, fournissant une tension alternative
généralement de haute fréquence et comportant des éléments de stabilisation nécessaires
pour l'amorçage et le fonctionnement d'une ou de plusieurs lampes à fluorescence
–––––––––
1)
A publier.
61347-2-3 ¤ IEC:2000+A1:2004 – 13 –
LAMP CONTROLGEAR –
Part 2-3: Particular requirements for a.c. supplied electronic ballasts
for fluorescent lamps
1 Scope
This part of IEC 61347 specifies particular safety requirements for electronic ballasts for use
on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the
supply frequency, associated with fluorescent lamps as specified in IEC 60081 and
IEC 60901, and other fluorescent lamps for high-frequency operation.
Particular requirements for electronic ballasts with means of protection against overheating
are given in annex C.
Particular requirements for a.c./d.c. supplied electronic ballasts for maintained emergency
lighting are given in annex J.
Performance requirements are the subject of IEC 60929.
2 Normative references
For the purpose of this part of IEC 61347, the normative references given in clause 2 of
IEC 61347-1 which are mentioned in this standard apply, together with the following normative
references.
IEC 60598-2-22, Luminaires – Part 2-22: Particular requirements – Luminaires for emergency
lighting
IEC 61347-1, Lamp controlgear – Part 1: General and safety requirements
IEC 61347-2-7, Lamp controlgear – Part 2-7: Particular requirements for d.c. supplied
1)
electronic ballasts for emergency lighting
3 Definitions
For the purpose of this part of IEC 61347, the definitions of clause 3 of IEC 61347-1 apply,
together with the following:
3.1
a.c. supplied electronic ballast
mains-supplied a.c. to a.c. invertor including stabilizing elements for starting and operating
one or more tubular fluorescent lamps, generally at high frequency
––––––––––
1)
To be published.
– 14 – 61347-2-3 ¤ CEI:2000+A1:2004
3.2
ballast à gradation
la puissance de la lampe (flux lumineux) du ballast électronique commandée entre les valeurs
minimale (ou nulle) et maximale par un signal appliqué à l'entrée de commande du ballast
3.3
valeur maximale de la puissance de lampe (d'un ballast à gradation)
puissance de lampe (flux lumineux) qui est conforme à 8.1 de la CEI 60929, sauf déclaration
différente du fabricant ou du vendeur responsable
3.4
tension de crête maximale autorisée
la plus haute tension de crête permise au travers de n’importe quel isolant en condition de
circuit ouvert et dans n’importe quelle condition de fonctionnement normale ou anormale. La
tension de crête maximale est liée à la tension efficace de fonctionnement déclarée; voir
tableau 1.
3.5
valeur minimale de la puissance de lampe (d'un ballast à gradation)
pourcentage le plus bas de la puissance de lampe définie en 3.3 déclaré par le fabricant ou le
vendeur responsable
3.6
bornes de réglage
connexions au ballast électronique qui sont utilisées pour appliquer un signal de réglage afin
de modifier le flux lumineux
NOTE Les bornes de l'alimentation peuvent également agir comme bornes de réglage.
3.7
signal de réglage
signal qui peut être une tension alternative ou continue et qui peut être modulé de manière
analogique, digitale ou autre pour transmettre l'information nécessaire au ballast dans le but de
modifier le flux lumineux
3.8
ballasts électroniques alimentés en courant alternatif ou continu destinés à l'éclairage
de secours de type permanent
onduleur alimenté en courant alternatif par le réseau ou en continu par batteries, fournissant
une tension alternative généralement de haute fréquence et comportant des éléments de
stabilisation nécessaires pour l'amorçage et le fonctionnement d'une ou de plusieurs lampes à
fluorescence pour l’éclairage de secours
3.9
résistance de substitution de cathode
résistance de substitution de cathode comme spécifié sur la feuille de caractéristiques de
lampe appropriée de la CEI 60081 ou de la CEI 60901 ou comme déclaré par le fabricant de
lampe concerné ou le vendeur responsable
4 Prescriptions générales
Les prescriptions de l’article 4 de la CEI 61347-1 s’appliquent, avec l’adjonction de la
prescription suivante:
Les ballasts électroniques alimentés en courant alternatif ou continu destinés à l'éclairage de
secours doivent satisfaire aux prescriptions de l’annexe J.
61347-2-3 ¤ IEC:2000+A1:2004 – 15 –
3.2
controllable ballast
lamp power (light output) of the electronic ballast controlled between the minimum value (or
off) and the maximum value by the signal on the control input of the ballast
3.3
maximum value of lamp power (of a controllable ballast)
lamp power (light output) which complies with 8.1 of IEC 60929, unless otherwise declared by
the manufacturer or responsible vendor
3.4
maximum allowed peak voltage
highest permitted peak voltage across any insulation under open-circuit condition and any
normal and abnormal operating conditions. The maximum peak voltage is related to the
declared r.m.s. working voltage; see table 1
3.5
minimum value of lamp power (of a controllable ballast)
lowest percentage of the lamp power defined in 3.3 declared by the manufacturer or
responsible vendor
3.6
control terminals
connections to the electronic ballast which are used to apply a control signal for changing the
light output
NOTE The power supply terminals can also act as control terminals.
3.7
control signal
signal which may be an a.c. or d.c. voltage, and which by analogue, digital or other means
may be modulated to convey the necessary information to the ballast for the purpose of
changing the light output
3.8
a.c./d.c. supplied electronic ballast for maintained emergency lighting
mains/battery-supplied a.c./d.c to a.c. invertor including stabilizing elements for starting and
operating one or more tubular fluorescent lamps, generally at high frequency for emergency
lighting
3.9
cathode dummy resistor
cathode substitution resistor as specified on the relevant lamp data sheet of IEC 60081 or
IEC 60901 or as declared by the relevant lamp manufacturer or by the responsible vendor
4 General requirements
The requirements of clause 4 of IEC 61347-1 apply, together with the following additional
requirement:
AC/d.c. electronic ballasts for emergency lighting shall comply with the requirements of
annex J.
– 16 – 61347-2-3 ¤ CEI:2000+A1:2004
5 Généralités sur les essais
Les prescriptions de l'article 5 de la CEI 61347-1 s'appliquent, avec l'adjonction de la
prescription suivante:
Nombre de spécimens
Le nombre suivant de spécimens doit être soumis pour les essais:
– une unité pour les essais des articles 6 à 12 et 15 à 22;
– une unité pour les essais de l’article 14 (des unités supplémentaires ou des composants
peuvent être demandés, si nécessaire, après consultation du fabricant).
Les essais pour satisfaire aux prescriptions de sécurité pour les ballasts électroniques
alimentés en courant alternatif ou continu destinés à l'éclairage de secours sont effectués dans
les conditions spécifiées à l’annexe J.
6 Classification
Les prescriptions de l'article 6 de la CEI 61347-1 s'appliquent.
7 Marquage
Les ballasts qui forment une partie intégrée dans le luminaire n’ont pas besoin d’être marqués.
7.1 Marquages obligatoires
Les ballasts autres que les ballasts intégrés doivent être marqués d’une manière claire et
durable, en conformité avec les prescriptions de 7.2 de la CEI 61347-1, avec les marquages
obligatoires suivants:
– points a), b), c), d), e), l) et k) de 7.1 de la CEI 61347-1, conjointement avec
– le symbole de mise à la terre, le cas échéant;
– pour les ballasts à gradation, les bornes de commande doivent être identifiées;
– une déclaration de la tension maximale de fonctionnement (efficace) selon 12.2 entre
– les bornes de sortie;
– n’importe quelle borne de sortie et la terre, si cela est applicable.
Le marquage pour chacune de ces deux valeurs doit être effectué par m
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...