IEC 61881:1999
(Main)Railway applications - Rolling stock equipment - Capacitors for power electronics
- Abstract
Specifies capacitors used below an operating frequency of 2500 Hz with a rated voltage limited to 10000 V. Distinguishes beween a.c. and d.c. capacitors
- Status
- Replaced
- Publication Date
- 02-Sep-1999
- Technical Committee
- TC 9 - Electrical equipment and systems for railways
- Drafting Committee
- WG 3 - TA 5/WG 3
- Current Stage
- DELPUB - Deleted publication - 99 Deleted
- Start Date
- 06-Aug-2010
Relations
- Effective Date
- 05-Sep-2023
Get Certified
Connect with accredited certification bodies for this standard

IRIS Certification (UNIFE)
International Railway Industry Standard certification.

TÜV SÜD Rail GmbH
TÜV SÜD railway certification services.

Bureau Veritas Railway Certification
Railway and transportation certification.
Sponsored listings
Frequently Asked Questions
IEC 61881:1999 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Railway applications - Rolling stock equipment - Capacitors for power electronics". This standard covers: Specifies capacitors used below an operating frequency of 2500 Hz with a rated voltage limited to 10000 V. Distinguishes beween a.c. and d.c. capacitors
Specifies capacitors used below an operating frequency of 2500 Hz with a rated voltage limited to 10000 V. Distinguishes beween a.c. and d.c. capacitors
IEC 61881:1999 is classified under the following ICS (International Classification for Standards) categories: 45.060.01 - Railway rolling stock in general. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61881:1999 has the following relationships with other standards: It is inter standard links to IEC 61881-1:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 61881:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
NORME CEI
INTERNATIONALE IEC
INTERNATIONAL
Première édition
STANDARD
First edition
1999-09
Applications ferroviaires – Matériel roulant –
Condensateurs pour électronique de puissance
Railway applications – Rolling stock equipment –
Capacitors for power electronics
Numéro de référence
Reference number
CEI/IEC 61881:1999
Numéros des publications Numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. issued with a designation in the 60000 series.
Publications consolidées Consolidated publications
Les versions consolidées de certaines publications de Consolidated versions of some IEC publications
la CEI incorporant les amendements sont disponibles. including amendments are available. For example,
Par exemple, les numéros d’édition 1.0, 1.1 et 1.2 edition numbers 1.0, 1.1 and 1.2 refer, respectively, to
indiquent respectivement la publication de base, la the base publication, the base publication incor-
publication de base incorporant l’amendement 1, et la porating amendment 1 and the base publication
publication de base incorporant les amendements 1 incorporating amendments 1 and 2.
et 2.
Validité de la présente publication Validity of this publication
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. the content reflects current technology.
Des renseignements relatifs à la date de reconfir- Information relating to the date of the reconfirmation
mation de la publication sont disponibles dans le of the publication is available in the IEC catalogue.
Catalogue de la CEI.
Les renseignements relatifs à des questions à l’étude et Information on the subjects under consideration and
des travaux en cours entrepris par le comité technique work in progress undertaken by the technical
qui a établi cette publication, ainsi que la liste des committee which has prepared this publication, as well
publications établies, se trouvent dans les documents ci- as the list of publications issued, is to be found at the
dessous: following IEC sources:
• «Site web» de la CEI* • IEC web site*
• Catalogue des publications de la CEI • Catalogue of IEC publications
Publié annuellement et mis à jour Published yearly with regular updates
régulièrement (On-line catalogue)*
(Catalogue en ligne)*
• Bulletin de la CEI
• IEC Bulletin
Disponible à la fois au «site web» de la CEI*
Available both at the IEC web site* and
et comme périodique imprimé
as a printed periodical
Terminologie, symboles graphiques
Terminology, graphical and letter
et littéraux
symbols
En ce qui concerne la terminologie générale, le lecteur
For general terminology, readers are referred to
se reportera à la CEI 60050: Vocabulaire Electro-
IEC 60050: International Electrotechnical Vocabulary
technique International (VEI).
(IEV).
Pour les symboles graphiques, les symboles littéraux
For graphical symbols, and letter symbols and signs
et les signes d'usage général approuvés par la CEI, le
approved by the IEC for general use, readers are
lecteur consultera la CEI 60027: Symboles littéraux à
referred to publications IEC 60027: Letter symbols to
utiliser en électrotechnique, la CEI 60417: Symboles
be used in electrical technology, IEC 60417: Graphical
graphiques utilisables sur le matériel. Index, relevé et
symbols for use on equipment. Index, survey and
compilation des feuilles individuelles, et la CEI 60617:
compilation of the single sheets and IEC 60617:
Symboles graphiques pour schémas.
Graphical symbols for diagrams.
* Voir adresse «site web» sur la page de titre.
* See web site address on title page.
NORME CEI
INTERNATIONALE IEC
INTERNATIONAL
Première édition
STANDARD
First edition
1999-09
Applications ferroviaires – Matériel roulant –
Condensateurs pour électronique de puissance
Railway applications – Rolling stock equipment –
Capacitors for power electronics
IEC 1999 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
X
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61881 © CEI:1999
SOMMAIRE
Pages
AVANT-PROPOS . 6
Articles
1 Généralités. 8
1.1 Domaine d’application et objet . 8
1.2 Références normatives . 10
1.3 Définitions . 10
1.4 Conditions de service . 18
2 Exigences de qualité et essais . 22
2.1 Prescriptions d'essai. 22
2.2 Classification des essais. 22
2.3 Mesures de la capacité et de la tangente tan δ (essai de série) . 24
2.4 Mesure de la tangente de perte (tan δ) du condensateur (essai de type). 26
2.5 Essai de tension entre bornes. 26
2.6 Essai de tension alternative entre bornes et boîtier . 28
2.7 Essai de dispositif de décharge interne . 30
2.8 Essai d'étanchéité . 30
2.9 Essai de tension de choc . 30
2.10 Essai de stabilité thermique . 32
2.11 Essai d'autorégénération . 34
2.12 Mesure de la fréquence de résonance. 34
2.13 Essais d'environnement . 34
2.14 Essais mécaniques. 36
2.15 Essai d'endurance . 38
2.16 Essai destructif. 42
2.17 Essai de déconnexion des coupe-circuit. 50
2.18 Mesures de décharge partielle (essais de type facultatifs) . 56
3 Surcharges . 56
3.1 Tension maximale admissible . 56
4 Prescriptions de sécurité. 56
4.1 Dispositif de décharge . 56
4.2 Connexions du boîtier . 58
4.3 Protection de l'environnement . 58
4.4 Autres prescriptions de sécurité. 58
5 Marquages . 5 8
5.1 Marquage des unités . 58
61881 © IEC:1999 – 3 –
CONTENTS
Page
FOREWORD . 7
Clause
1 General . 9
1.1 Scope and object. 9
1.2 Normative references . 11
1.3 Definitions . 11
1.4 Service conditions . 19
2 Quality requirements and tests. 23
2.1 Test requirements. 23
2.2 Classification of tests. 23
2.3 Capacitance and tan δ measurements (routine test) . 25
2.4 Capacitor loss tangent (tan δ) measurement (type test) . 27
2.5 Voltage test between terminals . 27
2.6 AC voltage test between terminals and case . 29
2.7 Test of internal discharge device. 31
2.8 Sealing test . 31
2.9 Surge discharge test. 31
2.10 Thermal stability test. 33
2.11 Self-healing test. 35
2.12 Resonance frequency measurement . 35
2.13 Environmental testing . 35
2.14 Mechanical testing. 37
2.15 Endurance test . 39
2.16 Destruction test . 43
2.17 Disconnecting test on fuses . 51
2.18 Partial discharge measurements (optional type tests). 57
3 Overloads.57
3.1 Maximum permissible voltage . 57
4 Safety requirements. 57
4.1 Discharge device . 57
4.2 Case connections . 59
4.3 Protection of the environment . 59
4.4 Other safety requirements. 59
5 Markings. 59
5.1 Marking of the units . 59
– 4 – 61881 © CEI:1999
Articles Pages
6 Guide d'installation et de fonctionnement . 60
6.1 Généralités. 60
6.2 Choix de la tension assignée . 62
6.3 Température de fonctionnement . 62
6.4 Conditions de service particulières. 64
6.5 Surtensions . 64
6.6 Courants de surcharge . 64
6.7 Dispositifs de commutation et de protection . 64
6.8 Choix des lignes de fuite et des distances d'isolement . 66
6.9 Connexions . 66
6.10 Connexions parallèles des condensateurs. 66
6.11 Connexions de condensateurs en série. 66
6.12 Pertes magnétiques et courants de Foucault. 68
6.13 Guide pour la protection par coupe-circuit à fusibles et sectionneur. 68
Annexe A (informative) Formes d'onde. 70
Annexe B (normative) Limites de fonctionnement des condensateurs avec des tensions
sinusoïdales exprimées en fonction de la fréquence et à température maximale (θ ) . 76
max
Annexe C (normative) Méthodes de mesure de la fréquence de résonance – Exemples . 80
Annexe D (informative) Bibliographie. 84
Figure 1 – Montage pour essai destructif. 44
Figure 2 – Source N de courant continu et alternatif . 48
Figure 3 – Source N de courant continu . 50
Figure A.1 – Exemple de durée d’impulsion de courant . 74
Figure B.1 – Conditions d’alimentation électrique . 76
Figure C.1 – Circuit de mesure . 80
Figure C.2 – Relation entre la tension aux bornes du condensateur et la fréquence
d’alimentation . 80
Figure C.3 – Forme d’onde du courant de décharge . 82
Tableau 1 – Température maximale de l'agent de refroidissement pendant une durée
illimitée . 20
Tableau 2 – Tension d'essai entre bornes . 26
Tableau 3 – Essai à chaleur humide . 36
Tableau 4 – Essai de robustesse des bornes . 36
Tableau 5 – Exemple de courant admissible des bornes à vis et boulons . 38
Tableau 6 – Essai d'endurance . 40
Tableau 7 – Tension maximale admissible . 56
61881 © IEC:1999 – 5 –
Clause Page
6 Guide to installation and operation . 61
6.1 General . 61
6.2 Choice of rated voltage . 63
6.3 Operating temperature. 63
6.4 Special service conditions. 65
6.5 Overvoltages . 65
6.6 Overload currents . 65
6.7 Switching and protective devices. 65
6.8 Choice of creepage distance and clearance . 67
6.9 Connections . 67
6.10 Parallel connections of capacitors . 67
6.11 Series connections of capacitors. 67
6.12 Magnetic losses and eddy currents . 69
6.13 Guide for fuse and disconnector protection . 69
Annex A (informative) Waveforms . 71
Annex B (normative) Operational limits of capacitors with sinusoidal voltages
as a function of frequency and at maximum temperature (θ ) . 77
max
Annex C (normative) Resonance frequency measuring methods – Examples. 81
Annex D (informative) Bibliography . 85
Figure 1 – Destruction test arrangement . 45
Figure 2 – N source d.c. plus a.c. . 49
Figure 3 – N source d.c. . 51
Figure A.1 – Example of current pulse width . 75
Figure B.1 – Supply conditions. 77
Figure C.1 – Measuring circuit . 81
Figure C.2 – Relation between the voltage across the capacitor and the supply frequency. 81
Figure C.3 – Discharge current wave shape . 83
Table 1 – Maximum temperature of cooling medium for unlimited time . 21
Table 2 – Test voltage between terminals . 27
Table 3 – Damp heat test. 37
Table 4 – Testing the robustness of terminals . 37
Table 5 – Example of current-carrying capacities of screw terminals and bolts . 39
Table 6 – Endurance test. 41
Table 7 – Maximum permissible voltage. 57
– 6 – 61881 © CEI:1999
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
___________
APPLICATIONS FERROVIAIRES –
MATÉRIEL ROULANT –
CONDENSATEURS POUR ÉLECTRONIQUE DE PUISSANCE
AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, rapports techniques ou guides et agréés comme tels par les Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 61881 a été établie par le comité d'études 9 de la CEI: Matériel
électrique ferroviaire.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
9/522/FDIS 9/530/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 3.
Les annexes A et D sont données uniquement à titre d’information.
Les annexes B et C font partie intégrante de cette norme.
Le comité a décidé que cette publication reste valable jusqu'en 2004. A cette date, selon
décision préalable du comité, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée; ou
• amendée.
61881 © IEC:1999 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________
RAILWAY APPLICATIONS –
ROLLING STOCK EQUIPMENT –
CAPACITORS FOR POWER ELECTRONICS
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined on agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61881 has been prepared by IEC technical committee 9: Electric
railway equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
9/522/FDIS 9/530/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
Annexes A and D are for information only.
Annexes B and C form an integral part of this standard.
The committee has decided that this publication remains valid until 2004. At this date, in
accordance with the committee's decision, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition; or
• amended.
– 8 – 61881 © CEI:1999
APPLICATIONS FERROVIAIRES –
MATÉRIEL ROULANT –
CONDENSATEURS POUR ÉLECTRONIQUE DE PUISSANCE
1 Généralités
1.1 Domaine d’application et objet
La présente Norme internationale s'applique aux condensateurs pour électronique de
puissance destinés à être utilisés sur le matériel roulant.
La tension assignée des condensateurs couverts par la présente norme est limitée à 10 000 V.
La fréquence de fonctionnement des systèmes dans lesquels ces condensateurs sont utilisés
est généralement inférieure à 2 500 Hz, tandis que les fréquences d'impulsion sont suscep-
tibles d'atteindre plusieurs milliers de hertz et de dépasser dans certains cas 10 000 Hz.
Une distinction est faite entre les condensateurs pour courant alternatif et ceux pour courant
continu.
Ils sont considérés comme des composants montés dans des enveloppes.
NOTE – La présente norme recouvre une gamme extrêmement vaste de condensateurs destinés à de nombreuses
applications: protection contre les surtensions, filtrage côté continu et côté alternatif, circuits de commutation,
stockage d'énergie en courant continu, onduleurs auxiliaires, etc.
Les éléments suivants sont exclus de la présente norme:
– condensateurs pour les installations de génération de chaleur par induction soumis à des
fréquences comprises entre 40 Hz et 24 000 Hz (voir CEI 60110);
– condensateurs des moteurs et applications semblables (voir CEI 60252);
– condensateurs destinés à être utilisés dans les circuits pour le blocage d'un ou plusieurs
harmoniques dans les réseaux d'alimentation;
– condensateurs pour courant alternatif de petite taille utilisés pour les lampes à
fluorescence et à décharges (voir CEI 61048 et CEI 61049);
– condensateurs d'antiparasitage (voir CEI 60384-14);
– condensateurs shunt destinés à être installés sur des réseaux à courant alternatif avec
tension assignée supérieure à 1 000 V (voir CEI 60871-1 et CEI 60871-2);
– condensateurs shunt de puissance autorégénérateurs destinés à être installés sur des
réseaux à courant alternatif de tension assignée inférieure ou égale à 1 000 V (voir
CEI 60831-1 et CEI 60831-2);
– condensateurs shunt de puissance non autorégénérateurs destinés à être utilisés sur des
réseaux de courant alternatif de tension assignée inférieure ou égale à 1 000 V (voir CEI
60931-1 et CEI 60931-2);
– condensateurs électroniques non utilisés dans les circuits de puissance (voir CEI 60080 et
CEI 60166);
– condensateurs en série destinés à être utilisés sur des réseaux (voir CEI 60143);
– condensateurs de couplage et diviseurs capacitifs (voir CEI 60358);
– condensateurs destinés à des applications nécessitant un stockage d'énergie/décharge de
courant élevé telles que des photocopieurs et des lasers;
– condensateurs pour four à micro-ondes.
Des exemples sont fournis à l'article 6.
61881 © IEC:1999 – 9 –
RAILWAY APPLICATIONS –
ROLLING STOCK EQUIPMENT –
CAPACITORS FOR POWER ELECTRONICS
1 General
1.1 Scope and object
This International Standard applies to capacitors for power electronics intended to be used on
rolling stock.
The rated voltage of capacitors covered by this part is limited to 10 000 V.
The operating frequency of the systems in which these capacitors are used is usually below
2 500 Hz, while the pulse frequencies may go up to several thousand hertz, in some cases
beyond 10 000 Hz.
It distinguishes between a.c. and d.c. capacitors.
They are considered as components mounted in enclosures.
NOTE – This standard covers an extremely wide range of capacitor technologies for numerous applications:
overvoltage protection, d.c. and a.c. filtering, switching circuits, d.c. energy storage, auxiliary inverters, etc.
The following are excluded from this standard:
– capacitors for induction heat-generating plants operating at frequencies between 40 Hz and
24 000 Hz (see IEC 60110);
– capacitors for motor applications and the like (see IEC 60252);
– capacitors to be used in circuits for blocking one or more harmonics in power supply
networks;
– small a.c. capacitors as used for fluorescent and discharge lamps (see IEC 61048 and
IEC 61049);
– capacitors for suppression of radio interference (see IEC 60384-14);
– shunt capacitors for a.c. power systems having a rated voltage above 1 000 V (see
IEC 60871-1 and IEC 60871-2);
– shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to
and including 1 000 V (see IEC 60831-1 and IEC 60831-2);
– shunt power capacitor of the non self-healing type for a.c. systems having a rated voltage
up to and including 1 000 V (see IEC 60931-1 and IEC 60931-2);
– electronic capacitors not used in power circuits (see IEC 60080 and IEC 60166);
– series capacitors for power systems (see IEC 60143);
– coupling capacitors and capacitors dividers (see IEC 60358);
– capacitors for applications requiring energy storage/high current discharge such as
photocopies and lasers;
– capacitors for microwave ovens.
Examples are given in clause 6.
– 10 – 61881 © CEI:1999
1.2 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence
qui y est faite, constituent des dispositions valables pour la présente Norme internationale.
Pour les références datées, les amendements ultérieurs ou les révisions de ces publications ne
s’appliquent pas. Toutefois, les parties prenantes aux accords fondés sur la présente Norme
internationale sont invitées à rechercher la possibilité d'appliquer les éditions les plus récentes
des documents normatifs indiqués ci-après. Pour les références non datées, la dernière édition
du document normatif en référence s’applique. Les membres de la CEI et de l'ISO possèdent
le registre des Normes internationales en vigueur.
CEI 60068-2-3, Essais d'environnement – Deuxième partie: Essais. Essai Ca: Essai continu de
chaleur humide
CEI 60068-2-14, Essais d'environnement – Deuxième partie: Essais. Essai N: Variations de
température
CEI 60068-2-20, Essais d'environnement – Deuxième partie: Essais. Essai T: Soudure
CEI 60068-2-21, Essais d'environnement – Deuxième partie: Essais. Essai U: Robustesse des
sorties et des dispositifs de fixation
CEI 60077-1, Applications ferroviaires – Composants électrotechniques – Partie 1: Conditions
1)
générales de service
CEI 60269-1, Fusibles basse tension – Première partie: Règles générales
CEI 60721-3-5, Classification des conditions d'environnement – Partie 3: Classification des
groupements des agents d'environnement et de leurs sévérités. Installations des véhicules
terrestres
CEI 61373, Applications ferroviaires – Matériel roulant – Essais de chocs et vibrations
1.3 Définitions
Pour les besoins de la présente Norme internationale, les définitions suivantes s'appliquent.
1.3.1
élément de condensateur (ou élément)
partie indivisible d'un condensateur constituée de deux électrodes séparées par un diélectrique
1.3.2
condensateur unitaire (ou unité)
ensemble d'un ou plusieurs éléments de condensateurs placés dans une même enveloppe et
reliés à des bornes de sortie
1.3.3
batterie de condensateurs
ensemble de deux condensateurs unitaires ou plus, raccordés entre eux électriquement
1.3.4
condensateur
terme générique utilisé quand il n'est pas nécessaire d'indiquer si l'on fait référence à un
élément, une unité ou une batterie de condensateurs
___________
1)
A publier.
61881 © IEC:1999 – 11 –
1.2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this International Standard. For dated references, subsequent
amendments to, or revisions of, any of these publications do not apply. However, parties to
agreements based on this International Standard are encouraged to investigate the possibility
of applying the most recent editions of the normative documents indicated below. For undated
references, the latest edition of the normative document referred to applies. Members of IEC
and ISO maintain registers of currently valid International Standards.
IEC 60068-2-3, Environmental testing – Part 2: Tests. Test Ca: Damp heat, steady state
IEC 60068-2-14, Environmental testing – Part 2: Tests. Test N: Change of temperature
IEC 60068-2-20, Environmental testing – Part 2: Tests. Test T: Soldering
IEC 60068-2-21, Environmental testing – Part 2: Tests. Test U: Robustness of terminations and
integral mounting devices
IEC 60077-1, Railway applications – Electrotechnical components – Part 1: General service
1)
conditions
IEC 60269-1, Low-voltage fuses – Part 1: General requirements
IEC 60721-3-5, Classification of environmental conditions – Part 3: Classification of groups of
environmental parameters and their severities – Ground vehicle installations
IEC 61373, Railway applications – Rolling stock equipment – Shock and vibration tests
1.3 Definitions
For the purpose of this International Standard, the following definitions apply.
1.3.1
capacitor element (or element)
indivisible part of a capacitor consisting of two electrodes separated by a dielectric
1.3.2
capacitor unit (or unit)
assembly of one or more capacitor elements in the same container with terminals brought out
1.3.3
capacitor bank
assembly of two or more capacitor units, electrically connected to each other
1.3.4
capacitor
general term used when it is not necessary to state whether reference is made to an element, a
unit or a capacitor bank
___________
1)
To be published.
– 12 – 61881 © CEI:1999
1.3.5
installation de condensateurs
ensemble de condensateurs unitaires et de leurs accessoires, destiné à la connexion à un
réseau
1.3.6
condensateur pour électronique de puissance
condensateur de puissance destiné à être utilisé dans un matériel électronique de puissance et
capable de fonctionner de façon continue pour un courant et une tension sinusoïdaux ou non
1.3.7
condensateur à feuille métallique (non autorégénérateur)
condensateur dont les électrodes sont généralement constituées de feuilles métalliques
séparées par un diélectrique; en cas de claquage du diélectrique, le condensateur ne se
rétablit pas
1.3.8
condensateur à diélectrique métallisé autorégénérateur
condensateur dont les électrodes sont métallisées (généralement par évaporation); en cas de
claquage du diélectrique, le condensateur se rétablit
1.3.9
condensateur pour courant alternatif
condensateur essentiellement conçu pour fonctionner sous tension alternative
NOTE – Il est admis d'utiliser les condensateurs pour courant alternatif avec une tension continue atteignant la
tension assignée seulement avec l'autorisation du constructeur du condensateur.
1.3.10
condensateur pour courant continu
condensateur essentiellement conçu pour fonctionner sous tension continue
NOTE – Il est admis d'utiliser les condensateurs pour courant continu sous une tension alternative spécifiée
uniquement si le constructeur du condensateur l'autorise.
1.3.11
condensateur modèle
unité réduite simulant une unité ou un élément complet lors d'un essai électrique, sans
diminuer la sévérité des conditions électriques, thermiques ou mécaniques
NOTE – Il est recommandé de toujours considérer la somme combinée des contraintes, par exemple la somme des
contraintes de température, de conditions mécaniques et électriques.
1.3.12
coupe-circuit (élément) interne
dispositif intégré dans le condensateur déconnectant un élément ou un groupe d'éléments en
cas de claquage
1.3.13
dispositifs à surpression
1.3.13.1
sectionneur à surpression
dispositif de déconnexion placé à l’intérieur du condensateur, destiné à interrompre le passage
du courant en cas de défaut du condensateur
61881 © IEC:1999 – 13 –
1.3.5
capacitor equipment
assembly of capacitor units and their accessories intended for connection to a network
1.3.6
capacitor for power electronics
power capacitor intended to be used in power electronic equipment and capable of operating
continuously under sinusoidal and non sinusoidal current and voltage
1.3.7
metal-foil capacitor (non self-healing)
capacitor in which the electrodes usually consist of metal foils separated by a dielectric, in the
event of a breakdown of the dielectric; the capacitor does not restore itself
1.3.8
self-healing metallized dielectric capacitor
capacitor, the electrodes of which are metallized (usually by evaporation); in the event of
dielectric breakdown, the capacitor restores itself
1.3.9
a.c. capacitor
capacitor essentially designed for operation with alternating voltage
NOTE – AC capacitors may be used with d.c. voltage up to the rated voltage only when authorized by the capacitor
manufacturer.
1.3.10
d.c. capacitor
capacitor essentially designed for operation with direct voltage
NOTE – DC capacitors may be used with a specified a.c. voltage only where authorized by the capacitor
manufacturer.
1.3.11
model capacitor
smaller unit which simulates a complete unit or element in an electrical test, without reducing
the severity of the electrical, thermal or mechanical conditions
NOTE – The combined sum of stresses should always be considered, for instance the sum of temperature,
mechanical conditions and electrical stresses.
1.3.12
internal (element) fuse
device incorporated in the capacitor which disconnects an element or a group of elements in
the event of breakdown
1.3.13
overpressure devices
1.3.13.1
overpressure disconnector
disconnecting device inside a capacitor, designed to interrupt the current path in case of
capacitor failure
– 14 – 61881 © CEI:1999
1.3.13.2
détecteur de surpression
dispositif conçu pour détecter une augmentation anormale de la pression interne par un/une
signal/coupure électrique et qui interrompt indirectement le passage du courant
1.3.14
dispositif de décharge interne
dispositif incorporé dans le condensateur raccordé entre les bornes de l'unité, capable de
réduire la tension résiduelle effectivement à zéro après que le condensateur a été déconnecté
du réseau d'alimentation
1.3.15
tension alternative assignée (U )
N
tension récurrente de crête maximale en fonctionnement de l'une ou l'autre des polarités,
présentant une forme d'onde d'inversion pour laquelle le condensateur a été conçu
NOTE 1 – La forme d'onde peut être variée. Des exemples sont donnés dans l'annexe A.
NOTE 2 – Il est admis que la valeur moyenne de la forme d'onde soit positive ou négative.
NOTE 3 – Il est important de noter que la tension alternative assignée n'est pas une valeur efficace.
NOTE 4 – Les définitions utilisées dans la présente norme peuvent différer de celles de la CEI 60077-1.
1.3.16
tension continue assignée (U )
NDC
tension de crête maximale en fonctionnement de l'une ou l'autre des polarités mais présentant
une forme d'onde sans inversion, pour laquelle le condensateur a été conçu, en vue d'un
fonctionnement continu
Les condensateurs d'amortissement, pour thyristors blocables par la gâchette (GTO), peuvent
être considérés comme des condensateurs pour courant continu avec une tension d'ondulation
égale à la tension continue assignée U = U .
NDC r
Dans le cas d'une tension d'inversion, il convient que l'utilisation fasse l'objet d'un accord entre
le client et le constructeur.
NOTE – Si la tension d'inversion est faible (moins de 10 %), on peut considérer qu’il n’y a plus d’inversion de la
forme d'onde. Il est recommandé pour les essais d'augmenter U et U de la tension d'inversion U.
NDC r
1.3.17
tension d'ondulation (U )
r
composante alternative crête-à-crête de la tension unidirectionnelle
1.3.18
tension de choc non récurrente (U )
s
tension de crête provoquée par une commutation ou toute autre perturbation du système,
autorisée pour un nombre de fois limité et pendant des durées inférieures à la période de base
1.3.19
tension d'isolement (U )
i
valeur efficace de l’onde sinusoïdale de tension conçue pour l'isolement des bornes des
condensateurs par rapport au boîtier ou à la terre. En l'absence de spécification, la valeur
efficace de la tension d'isolement est équivalente à la tension assignée divisée par 2
1.3.20
courant de crête maximal (Î)
courant de crête maximal pouvant survenir en fonctionnement continu
...



