Automatic electrical controls for household and similar use - Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements

Applies to automatic electrical pressure sensing controls with a minimum gauge pressure rating of -60 kPa and a maximum gauge pressure rating of 4,2 MPa, for use in, on or in association with, equipment for household and similar use that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof, including heating, air-conditioning and similar applications. Applies to inherent safety, operating values, operating sequences where such are associated with equipment protection, and to the testing of automatic electrical pressure sensing controls used in, on or in association with, household and similar equipment. This second edition constitutes a technical revision, which incorporates amended requirements for electronic control in Annex H.

Automatische elektrische Regel- und Steuergeräte für den Hausgebrauch und ähnliche Anwendungen - Teil 2-6: Besondere Anforderungen an automatische elektrische Druckregel- und Steuergeräte einschließlich mechanischer Anforderungen

Dispositifs de commande électrique automatiques à usage domestique et analogue - Partie 2-6: Règles particulières pour les dispositifs de commande électrique automatiques sensibles à la pression y compris les exigences mécaniques

S'applique aux dispositifs de commande électrique automatiques sensibles à la pression avec une caractéristique de pression effective minimale de -60 kPa et une caractéristique de pression effective maximale de 4,2 Mpa, destinés à être utilisés dans, sur, ou avec des matériels à usage domestique et analogue qui peuvent utiliser l'électricité, le gaz, le pétrole, un combustible solide, l'énergie thermique solaire, etc. ou une combinaison de ces énergies, y compris des applications de chauffage, climatisation et usages analogues. S'applique à la sécurité intrinsèque, aux valeurs et aux séquences de fonctionnement dans la mesure où elles interviennent dans la protection des matériels, ainsi qu'aux essais des dispositifs de commande électrique automatiques sensibles à la pression utilisés dans, sur ou avec des matériels à usage domestique et analogue. Cette deuxième édition constitue une révision technique, qui reprend les exigences modifiées pour les commandes électroniques de l'Annex H.

Avtomatske električne krmilne naprave za uporabo v gospodinjstvu in za podobno uporabo - 2-6. del: Posebne zahteve za avtomatske električne, na tlak občutljive naprave, vključno z mehanskimi zahtevami (IEC 60730-2-6:2007)

General Information

Status
Withdrawn
Publication Date
03-Sep-2008
Withdrawal Date
30-Jun-2011
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
26-Feb-2019
Completion Date
26-Feb-2019

Relations

Buy Standard

Standard
EN 60730-2-6:2009
English language
29 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Automatische elektrische Regel- und Steuergeräte für den Hausgebrauch und ähnliche Anwendungen -- Teil 2-6: Besondere Anforderungen an automatische elektrische Druckregel- und Steuergeräte einschließlich mechanischer AnforderungenDispositifs de commande électrique automatiques à usage domestique et analogue -- Partie 2-6: Règles particulières pour les dispositifs de commande électrique automatiques sensibles à la pression y compris les exigences mécaniquesAutomatic electrical controls for household and similar use -- Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements97.120Avtomatske krmilne naprave za domAutomatic controls for household useICS:Ta slovenski standard je istoveten z:EN 60730-2-6:2008SIST EN 60730-2-6:2009en,fr,de01-januar-2009SIST EN 60730-2-6:2009SLOVENSKI
STANDARDSIST EN 60730-2-6:1997/A2:1998SIST EN 60730-2-6:1997/A1:1998SIST EN 60730-2-6:19971DGRPHãþD

EUROPEAN STANDARD EN 60730-2-6 NORME EUROPÉENNE
EUROPÄISCHE NORM September 2008
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60730-2-6:2008 E
ICS 97.120 Supersedes EN 60730-2-6:1995 + A1:1997 + A2:1998
English version
Automatic electrical controls for household and similar use -
Part 2-6: Particular requirements for automatic electrical pressure
sensing controls including mechanical requirements (IEC 60730-2-6:2007, modified)
Dispositifs de commande électrique automatiques à usage domestique
et analogue -
Partie 2-6: Règles particulières pour
les dispositifs de commande électrique automatiques sensibles à la pression
y compris les exigences mécaniques (CEI 60730-2-6:2007, modifiée)
Automatische elektrische Regel- und Steuergeräte für den Hausgebrauch und ähnliche Anwendungen -
Teil 2-6: Besondere Anforderungen an automatische elektrische Druckregel- und Steuergeräte einschließlich mechanischer Anforderungen (IEC 60730-2-6:2007, modifiziert)
This European Standard was approved by CENELEC on 2008-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
(dop)
2009-07-01 – latest date by which the national standards conflicting with the EN have to be withdrawn
(dow)
2011-07-01 This Part 2-6 is to be used in conjunction with EN 60730-1:2000 + A1:2004, Automatic electrical controls for household and similar use – Part 1: General requirements, and any subsequent amendments. This Part 2-6 supplements or modifies the corresponding clauses in EN 60730-1 so as to convert that publication into the European Standard: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements. Where this Part 2-6 states "addition", "modification" or "replacement", the relevant requirement, test specification or explanatory matter in Part 1 should be adapted accordingly. Where no change is necessary, this Part 2-6 indicates that the relevant clause or subclause applies. In this publication, the following print types are used: – Requirements proper: in roman type. – Test specifications: in italic type. – Explanatory matter: in smaller roman type. Subclauses, notes, tables or figures which are additional to those in Part 1 are numbered starting from 101. This European Standard has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association and covers essential requirements of EC Directive EMC (2004/108/EC). See Annex ZZ. Annex ZZ has been added by CENELEC. __________ SIST EN 60730-2-6:2009

- 3 - EN 60730-2-6:2008 Endorsement notice The text of the International Standard IEC 60730-2-6:2007 was approved by CENELEC as a European Standard with agreed common modifications as given below. COMMON MODIFICATIONS 10 Terminals and terminations 10.1 Terminals and terminations for external copper conductors Delete Subclause “10.1.4 Addition:”.
18 Mechanical strength 18.101 Medium leakage Delete “Under consideration.” In paragraph 4 delete the text of a) and b) and replace with “the leakage rate is 70 l/h;” in both cases.
H.26 Electromagnetic compatibility (EMC) requirements - immunity H.26.10.5.101 Delete this additional subclause and replace by “Void”. ____________ SIST EN 60730-2-6:2009

Coverage of Essential Requirements of EC Directives This European Standard has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association and within its scope the standard covers all relevant essential requirements as given in Article 1 of Annex I of the EC Directive EMC (2004/108/EC). Compliance with this standard provides one means of conformity with the specified essential requirements of the Directive concerned. WARNING: Other requirements and other EC Directives may be applicable to the products falling within the scope of this standard. ___________
NORME INTERNATIONALECEIIEC INTERNATIONAL STANDARD 60730-2-6Deuxième éditionSecond edition2007-02 Dispositifs de commande électrique
automatiques à usage domestique et analogue – Partie 2-6: Règles particulières pour les dispositifs de commande électrique automatiques sensibles
à la pression y compris les exigences mécaniques Automatic electrical controls for household and similar use – Part 2-6: Particular requirements for automatic electrical pressure sensing
controls including mechanical requirements Pour prix, voir catalogue en vigueur For price, see current catalogue© IEC 2007
Droits de reproduction réservés

Copyright - all rights reserved Aucune partie de cette publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de l'éditeur. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission,
3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, SwitzerlandTelephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch
Web: www.iec.ch CODE PRIX PRICE CODE T Commission Electrotechnique InternationaleInternational Electrotechnical CommissionSIST EN 60730-2-6:2009

60730-2-6 © IEC:2007 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION ____________
AUTOMATIC ELECTRICAL CONTROLS FOR
HOUSEHOLD AND SIMILAR USE –
Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements
FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 60730-2-6 has been prepared by IEC technical committee 72: Automatic controls for household use. This second edition cancels and replaces the first edition published in 1991, Amendment 1 (1994) and amendment 2 (1997). This second edition constitutes a technical revision, which incorporates amended requirements for electronic controls in Annex H. SIST EN 60730-2-6:2009

60730-2-6 © IEC:2007 – 5 –
The text of this standard is based upon the following documents:
FDIS Report on voting 72/729/FDIS 72/737/RVD Full information on the voting for the approval of this part can be found in the Report on Voting indicated in the above table. This publication has been drafted in accordance with ISO/IEC Directives, Part 2. This Part 2-6 is intended to be used in conjunction with IEC 60730-1. It was established on the basis of the third edition of that standard (1999) and its amendment 1 (2003). Consideration may be given to future editions of, or amendments to, IEC 60730-1. This Part 2-6 supplements or modifies the corresponding clauses in IEC 60730-1 so as to convert that publication into the IEC standard: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements. Where this Part 2-6 states "addition", "modification" or "replacement", the relevant requirement, test specification or explanatory matter in Part 1 should be adapted accordingly. Where no change is necessary, this Part 2-6 indicates that the relevant clause or subclause applies. In the development of a fully international standard it has been necessary to take into consideration the differing requirements resulting from practical experience in various parts of the world and to recognize the variation in national electrical systems and wiring rules. The
“in some countries” notes regarding differing national practice are contained in the following subclauses: 10.1.4 and 18.101. In this publication, the following print types are used: – Requirements proper: in roman type. – Test specifications: in italic type. – Explanatory matter: in smaller roman type. Subclauses, notes, tables or figures which are additional to those in Part 1 are numbered starting from 101. A list of all parts of the IEC 60730 series, under the general title Automatic electrical controls for household and similar use, can be found on the IEC website. The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data related to the specific publication. At this date, the publication will be
• reconfirmed; • withdrawn; • replaced by a revised edition, or • amended.
60730-2-6 © IEC:2007 – 7 –
AUTOMATIC ELECTRICAL CONTROLS FOR
HOUSEHOLD AND SIMILAR USE –
Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements
1 Scope and normative references This clause of Part 1 is applicable except as follows: 1.1 Replacement: This part of IEC 60730 applies to automatic electrical pressure sensing controls with a minimum gauge pressure rating of –60 kPa and a maximum gauge
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.