Luminaires - Part 1: General requirements and tests

2022-01-12: This prAA includes common mods to prEN IEC (PR=71577)

Leuchten - Teil 1: Allgemeine Anforderungen und Prüfungen

Luminaires - Partie 1: Exigences générales et essais

No scope available

Svetilke - 1. del: Splošne zahteve in preskusi - Dopolnilo AA

General Information

Status
Published
Publication Date
19-Dec-2024
Current Stage
6060 - Document made available - Publishing
Start Date
20-Dec-2024
Completion Date
20-Dec-2024

Relations

Buy Standard

Draft
prEN IEC 60598-1:2023/oprAA:2023
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
oSIST prEN IEC 60598-1:2023/oprAA:2023
01-maj-2023
Svetilke - 1. del: Splošne zahteve in preskusi - Dopolnilo AA
Luminaires - Part 1: General requirements and tests
Ta slovenski standard je istoveten z: prEN IEC 60598-1/prAA:2023
ICS:
29.140.40 Svetila Luminaires
oSIST prEN IEC 60598- en
1:2023/oprAA:2023
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN IEC 60598-1:2023/oprAA:2023

oSIST prEN IEC 60598-1:2023/oprAA:2023

EUROPEAN STANDARD DRAFT
prEN IEC 60598-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
prAA
March 2023
ICS  -
English Version
Luminaires - Part 1: General requirements and tests
To be completed To be completed
This draft amendment prAA, if approved, will modify the European Standard prEN IEC 60598-1; it is submitted to CENELEC members for
enquiry.
Deadline for CENELEC: 2023-06-02.

It has been drawn up by CLC/TC 34.

If this draft becomes an amendment, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

This draft amendment was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2023 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 75590 Ref. No. prEN IEC 60598-1/prAA:2023 E

oSIST prEN IEC 60598-1:2023/oprAA:2023
prEN IEC 60598-1:2023/prAA:2023 (E)
Contents Page
1 1 Modification to Clause 6, “Marking” . 4
2 2 Modification to Clause 7, “Construction” . 4
3 3 Modification to Clause 8, “External and internal wiring” . 4
4 4 Modification to Clause 14, “Endurance test and thermal test” . 5
5 5 Addition of Annex ZB, “Special national conditions” and Annex ZC, “A-deviations” . 5
6 6 Addition of Annex ZA, “Normative references to international publications with their
7 corresponding European publications” and Annex ZZ, “Relationship between this European standard
8 and the safety objectives of Directive 2014/35/EU [2014 OJ L96] aimed to be covered” . 7
9 7 Addition to the Bibliography . 14
oSIST prEN IEC 60598-1:2023/oprAA:2023
prEN IEC 60598-1:2023/prAA:2023 (E)
10 European foreword
11 This document (prEN IEC 60598-1:2023/prAA:2023) has been prepared by CLC/TC 34, “Lighting”.
12 This document is currently submitted to the Enquiry.
13 The following dates are proposed:
• latest date by which the existence of this (doa) dor + 6 months
document has to be announced at national
level
• latest date by which this document has to be (dop) dor + 12 months
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) dor + 36 months
conflicting with this document have to be (to be confirmed or
withdrawn modified when voting)
14 This document has been prepared under a Standardization Request given to CENELEC by the European
15 Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s)
16 / Regulation(s).
17 For the relationship with EU Directive(s) / Regulation(s), see informative Annex ZZ, which is an integral part of
18 this document.
oSIST prEN IEC 60598-1:2023/oprAA:2023
prEN IEC 60598-1:2023/prAA:2023 (E)
19 1 Modification to Clause 6, “Marking”
20 In 6.3.12, delete NOTE 4.
21 2 Modification to Clause 7, “Construction”
22 In 7.11.6, at the end of the paragraph commencing with “Following completion of these tests.”, add the
23 following text:
24 “, the test voltage however being reduced to 1 500 V”.
25 3 Modification to Clause 8, “External and internal wiring”
26 In 8.2.2, first paragraph, replace “IEC 60227 (all parts) and IEC 60245 (all parts)” with “EN 50525 (all parts)”,
27 and delete the second paragraph.
28 Replace Table 11 with the following new table:
29 “
30 Table 11 — Supply cord
Luminaire Rubber PVC No insulation
c c
Ordinary class I luminaires
H03RT-H H03VVH2-F
c
H03VV-F
c c
Ordinary class II luminaires
H05RR-F H03VVH2-F
c
H03VV-F
c a c
Luminaires other than ordinary class I
H05RN-F H03VVH2-F
and II
a c
H03VV-F
c
Portable rough service luminaires
H07RN-F
Class III or with SELV or PELV circuits  Uninsulated
b
luminaires
conductor
AC: U ≤ 25 V
DC: U ≤ 60V
Interrupted DC voltage for frequencies
between 10 Hz and
200 Hz: ≤ 25 V peak
Class III or with SELV or PELV circuits Unsheathed basic insulated
luminaires conductor
AC: 25 V < U ≤ 50 V
DC: 60 V < U ≤ 120 V
a
For indoor use only.
b
In accordance with IEC 60364 (all parts) uninsulated conductors are not allowed in certain special
installations and locations e.g. IEC 60364-7-701 “Locations containing a bath or shower”.
c
For supply voltages greater than 250 V, higher voltage grade cables and cords than those given in this
table may be necessary.
31 “
oSIST prEN IEC 60598-1:2023/oprAA:2023
prEN IEC 60598-1:2023/prAA:2023 (E)
32 4 Modification to Clause 14, “Endurance test and thermal test”
c
33 In subclause 14.4.3 c) Line 2, after “90 °C” add “(see footnote to Table 22 relating to unsleeved fixed wiring)”.
c
34 In Table 22 footnote add the following:
35 — after “European installation standards”: “(HD 60364 (all parts) and HD 384 (all parts))”;
36 — after “European cable standards”: “(EN 50525 (all parts))”.
37 5 Addition of Annex ZB, “Special national conditions” and Annex ZC,
38 “A-deviations”
39 Add the following Annexes ZB and ZC:
40 “
41 Annex ZB
42 (normative)
44 Special national conditions
45 Special national condition: National characteristic or practice that cannot be changed even over a long period,
46 e.g. climatic conditions, electrical earthing conditions.
47 NOTE If it affects harmonization, it forms part of the European Standard or Harmonization Document.
48 For the countries in which the relevant special national conditions apply these provisions are normative, for
49 other countries they are informative.
Clause Special national condition
6.4 Denmark
Supply cords of class I luminaires, which are delivered without a plug, shall be provided
with a visible tag with the following text:
Vigtigt !
Lederen med grøn/gul isolation
må kun tilsluttes en klemme mærket
eller
If essential for the safety of the luminaire, the tag shall in addition be provided with a
diagram, which shows the connection of the other conductors, or be provided with the
following text:
For tilslutning af the øvrige ledere,
se medfølgende vejledning.
NOTE  “ø” may be replaced by “oe”; “æ” may be replaced by “ae”.
8.2.18 Denmark
Socket-outlets intended for providing power to other appliances shall be in compliance
with DS60884-2-D1:2017, the Standard Sheets being applied as follows:
Class I . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard Sheet DK 1-3a, DK 1-1c and DK 1-1d
For class I luminaires, the earthing contact of the socket-outlet shall be electrically
connected to the earthing terminal of the appliance.
oSIST prEN IEC 60598-1:2023/oprAA:2023
prEN IEC 60598-1:2023/prAA:2023 (E)
Class II luminaires with a degree of protection not higher than IPX0, Standard Sheet
DKA 1-4a can be used.
EXEMPTION:
Socket-outlets supplied from isolation transformers (shaver supply units) and socket-
outlets on outdoor luminaires may be in accordance with the requirement of DS60884-2-
D1:2017 for fixed socket-outlets.
8.2.1 Cyprus
Domestic luminaires intended for connection to a standard United Kingdom 13 A socket
must be pre-fitted with an approved plug complying with BS 1363.
Cord sets for domestic luminaires for connection with an appliance inlet must be pre-
fitted with an approved plug complying with BS 1363.
Plugs must be fitted with the correct fuse.
Denmark
Supply cords on single-phase portable luminaires having a rated current not exceeding
13 A
shall be provided with a plug according to the following table:
Class of luminaire DS60884-2-D1:2017 EN 50075
Standard Sheet
Class I DK 2-1a, C 2b, C 3b or C 4
Class II DKA 2-1a, DKA 2-1b, C 5, C 6 I
For luminaires having an appliance inlet, the plug on the supply cord shall comply with the
above requirements.
If multi-phase luminaires and single-phase luminaires having a rated current exceeding
13 A are provided with a supply cord with a plug, the plug shall comply with the following
table or EN 60309.
Plug
Class of luminaire DS60884–2-D1:2017
Class I DK 6-1a
Class II DK 6-1a*
* Earthing contact not connected.
Finland
For luminaires provided with non-detachable flexible cables and cords and a plug, the plug
shall comply with the requirements of SFS 5610 and EN 50075, the Standard Sheets to
be applied being as follows:
— Class I luminaires SFS 5610, sheet IV or VII or IVA or VIIA
— Class II luminaires SFS 5610, sheet XVI (alt I only) or
SFS 5610, sheet XVII or EN 50075, sheet I
United Kingdom
Domestic luminaires intended for connection to a standard United Kingdom 13 A socket
must be pre-fitted with an approved plug complying with BS 1363.
Cord sets for domestic luminaires for connection with an appliance inlet must be pre-fitted
with an approved plug complying with BS 1363.
oSIST prEN IEC 60598-1:2023/oprAA:2023
prEN IEC 60598-1:2023/prAA:2023 (E)
50 Annex ZC
51 (informative)
53 A-deviations
54 A-deviation: National deviation due to regulations, the alteration of which is for the time being outside the
55 competence of the CEN and/or CENELEC member.
56 This European Standard falls under Directive 2014/35/EU.
57 NOTE (from CEN/CENELEC IR Part 2:2018, 2.16) Where standards fall under EC Directives or Regulations, it is the
58 view of the Commission of the European Communities (OJ No C 59; 1982-03-09) that the effect of the decision of the Court
59 of Justice in case 815/79 Cremonini/Vrankovich (European Court Reports 1980, p. 3583) is that compliance with A-
60 deviations is no longer mandatory and that the free movement of products complying with such a standard should not be
61 restricted within the EC except under the safeguard procedure provided for in the relevant Directive or Regulation.
62 A-deviations in non EU countries are valid instead of the respective provisions of the European Standard until
63 the national situation causing the A-deviation has changed.
Clause Deviation
7 and 8 France
th
(Arrêté of the 22 September 1969)
Socket-outlets 10/16 A intended for providing power to other appliances except those
supplied by an isolating transformer shall be shuttered.
(Arrêté du 30 décembre 2011 portant règlement de sécurité pour la construction des
immeubles de grande hauteur et leur protection contre les risques d’incendie et de
panique)
Section VIII, Installations électriques et éclairage
Article GH 48, Eclairage
§ 1  Généralités:
c)  Les parties externes des luminaires satisfont à l’essai au fil incandescent, la
température du fil incandescent étant de:
– 850°C pour les luminaires dans les escaliers et les circulations horizontales
communes ;
– 650°C pour les luminaires dans les locaux.
United Kingdom
(Approved Document B of the United Kingdom Building Regulations)
Particular fire protection requirements relating to thermoplastic diffusers are listed in
Subclause 6.15 of the above Regulations.”
64 6 Addition of Annex ZA, “Normative references to international publications with
65 their corresponding European publications” and Annex ZZ, “Relationship
66 between this European standard and the safety objectives of Directive
67 2014/35/EU [2014 OJ L96] aimed to be covered”
68 Add the following Annexes ZA and ZZ:
69 “
oSIST prEN IEC 60598-1:2023/oprAA:2023
prEN IEC 60598-1:2023/prAA:2023 (E)
70 Annex ZA
71 (normative)
73 Normative references to international publications
74 with their corresponding European publications
75 The following documents are referred to in the text in such a way that some or all of their content constitutes
76 requirements of this document. For dated references, only the edition cited applies. For undated references, the
77 latest edition of the referenced document (including any amendments) applies.
78 NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the
79 relevant EN/HD applies.
80 NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
81 www.cencenelec.eu.
Publication Year Title EN/HD Year
IEC 60061-2 (mod) - Lamp caps and holders together with gauges for EN 60061-2
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.