Abstract

Specifies standardized nominal cross-section areas from 0.5 mm2 to 2 000 mm2, numbers and diameters of wires and resistance values of conductors in electric cables and flexible cords. Classifies conductors for: 1.Cables for fixed installations -Class 1, solid conductors; -Class 2, stranded conductors. 2.Flexible copper conductors -Class 5, -Class 6 (more flexible than Class 5). Includes table of temperature correction factors kt for conductor resistance to correct the measured resistance at t °C to 20°C. Does not apply to conductors for telecommunication purposes. Applies to conductors of special design only when stated in the specification for the type of cable. Conductors of special design are, for example. conductors for pressure cables, conductors in extra-flexible welding cables or in special types of flexible cables for having the cores twisted together with unusually short lays. Note: In this edition, the number of classes of conductors has been reduced from 6 to 4.

Status
Withdrawn
Publication Date
30-Nov-2007
Technical Committee
CLC/TC 20 - Electric cables
Drafting Committee
TC 20 - Electric cables
Parallel Committee
TC 20 - Electric cables
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Dec-2007
Due Date
01-Dec-2007
Completion Date
01-Dec-2007

Buy Documents

Standardization document

HD 383 S2:1998

English language (21 pages)
Preview
Preview
e-Library read for
×1 day

Relations

Effective Date
28-Jan-2023
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026

Buy Documents

Standardization document

HD 383 S2:1998

English language (21 pages)
Preview
Preview
e-Library read for
×1 day

Frequently Asked Questions

HD 383 S2:1986 is a standardization document published by CLC. Its full title is "Conductors of insulated cables - First supplement: Guide to the dimensional limits of circular conductors". This standard covers: Specifies standardized nominal cross-section areas from 0.5 mm2 to 2 000 mm2, numbers and diameters of wires and resistance values of conductors in electric cables and flexible cords. Classifies conductors for: 1.Cables for fixed installations -Class 1, solid conductors; -Class 2, stranded conductors. 2.Flexible copper conductors -Class 5, -Class 6 (more flexible than Class 5). Includes table of temperature correction factors kt for conductor resistance to correct the measured resistance at t °C to 20°C. Does not apply to conductors for telecommunication purposes. Applies to conductors of special design only when stated in the specification for the type of cable. Conductors of special design are, for example. conductors for pressure cables, conductors in extra-flexible welding cables or in special types of flexible cables for having the cores twisted together with unusually short lays. Note: In this edition, the number of classes of conductors has been reduced from 6 to 4.

Specifies standardized nominal cross-section areas from 0.5 mm2 to 2 000 mm2, numbers and diameters of wires and resistance values of conductors in electric cables and flexible cords. Classifies conductors for: 1.Cables for fixed installations -Class 1, solid conductors; -Class 2, stranded conductors. 2.Flexible copper conductors -Class 5, -Class 6 (more flexible than Class 5). Includes table of temperature correction factors kt for conductor resistance to correct the measured resistance at t °C to 20°C. Does not apply to conductors for telecommunication purposes. Applies to conductors of special design only when stated in the specification for the type of cable. Conductors of special design are, for example. conductors for pressure cables, conductors in extra-flexible welding cables or in special types of flexible cables for having the cores twisted together with unusually short lays. Note: In this edition, the number of classes of conductors has been reduced from 6 to 4.

HD 383 S2:1986 has the following relationships with other standards: It is inter standard links to EN 60228:2005, HD 22.4 S3:1995, HD 22.3 S3:1995, HD 21.3 S3:1995, EN 60352-7:2002, EN 61058-1:2002/A2:2008, EN 60999-2:2003, EN 60309-1:1997, EN 62196-1:2003, EN 60947-7-2:1995, EN 61238-1:2003, EN 61138:1997, EN 60999-1:2000, EN 60702-1:2002, EN 60998-1:2004. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

HD 383 S2:1986 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-februar-1998
Conductors of insulated cables - Guide to the dimensional limits of circular
conductors (IEC 228:1978 + IEC 228A:1982 (Modified))
Conductors of insulated cables - First supplement: Guide to the dimensional limits of
circular conductors
Leiter für Kabel und isolierte Leitungen - Richtlinie für die dimensionsmäßigen Grenzen
von Rundleitern
Ames des câbles isolés - Premier complément: Guide pour les limites dimensionelles
des âmes circulaires
Ta slovenski standard je istoveten z: HD 383 S2:1986
ICS:
29.060.20 Kabli Cables
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

SIST HD 383 S2:199
...