Industrial communication networks - Profiles - Part 1: Fieldbus profiles

It defines a set of protocol specific communication profiles based primarily on the IEC 61158 series, to be used in the design of devices involved in communications in factory manufacturing and process control. Each profile selects specifications for the communications protocol stack at a device. It contains a minimal set of required services at the Application Layer and specification of options in intermediate layers defined through references. If no Application Layer is included, then a minimal set of required services at the Data-link layer is specified. The appropriate references to the protocol specific types are given in each communication profile family or associated profiles. It includes the following significant technical changes from the previous edition: partition of IEC 61158 parts 3, 4 ,5, and 6 of the third edition into multiple parts numbered for example IEC 61158 6 1, 6 2, 6 3, ; deletion of the former Type 6 fieldbus in IEC 61158 series and CPF 7 for lack of market relevance; addition of new types of fieldbuses in IEC 61158 series leading to new CPF 8, 9, and 16.

Industrielle Kommunikationsnetze - Profile - Teil 1: Feldbusprofile

Réseaux de communication industriels - Profils - Partie 1: Profils pour les bus de terrain

Industrijska komunikacijska omrežja - Profili - 1. del: Profili procesnih vodil (IEC 61784-1:2007)

General Information

Status
Withdrawn
Publication Date
12-Jun-2008
Withdrawal Date
30-Apr-2011
Drafting Committee
IEC/SC 65C - IEC_SC_65C
Parallel Committee
IEC/SC 65C - IEC_SC_65C
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Sep-2013
Completion Date
01-Sep-2013

Relations

Effective Date
28-Jan-2023
Effective Date
28-Jan-2023
Effective Date
29-Jan-2023

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

Sponsored listings

Frequently Asked Questions

EN 61784-1:2008 is a standard published by CLC. Its full title is "Industrial communication networks - Profiles - Part 1: Fieldbus profiles". This standard covers: It defines a set of protocol specific communication profiles based primarily on the IEC 61158 series, to be used in the design of devices involved in communications in factory manufacturing and process control. Each profile selects specifications for the communications protocol stack at a device. It contains a minimal set of required services at the Application Layer and specification of options in intermediate layers defined through references. If no Application Layer is included, then a minimal set of required services at the Data-link layer is specified. The appropriate references to the protocol specific types are given in each communication profile family or associated profiles. It includes the following significant technical changes from the previous edition: partition of IEC 61158 parts 3, 4 ,5, and 6 of the third edition into multiple parts numbered for example IEC 61158 6 1, 6 2, 6 3, ; deletion of the former Type 6 fieldbus in IEC 61158 series and CPF 7 for lack of market relevance; addition of new types of fieldbuses in IEC 61158 series leading to new CPF 8, 9, and 16.

It defines a set of protocol specific communication profiles based primarily on the IEC 61158 series, to be used in the design of devices involved in communications in factory manufacturing and process control. Each profile selects specifications for the communications protocol stack at a device. It contains a minimal set of required services at the Application Layer and specification of options in intermediate layers defined through references. If no Application Layer is included, then a minimal set of required services at the Data-link layer is specified. The appropriate references to the protocol specific types are given in each communication profile family or associated profiles. It includes the following significant technical changes from the previous edition: partition of IEC 61158 parts 3, 4 ,5, and 6 of the third edition into multiple parts numbered for example IEC 61158 6 1, 6 2, 6 3, ; deletion of the former Type 6 fieldbus in IEC 61158 series and CPF 7 for lack of market relevance; addition of new types of fieldbuses in IEC 61158 series leading to new CPF 8, 9, and 16.

EN 61784-1:2008 is classified under the following ICS (International Classification for Standards) categories: 35.100.20 - Data link layer; 35.240.20 - IT applications in office work; 35.240.50 - IT applications in industry. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 61784-1:2008 has the following relationships with other standards: It is inter standard links to EN 61784-1:2004, EN 61491:1998, EN 61784-1:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 61784-1:2008 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2008
1DGRPHãþD
SIST EN 61491:2001
SIST EN 61784-1:2004
Industrijska komunikacijska omrežja - Profili - 1. del: Profili procesnih vodil (IEC
61784-1:2007)
Industrial communication networks - Profiles - Part 1: Fieldbus profiles
Industrielle Kommunikationsnetze - Profile - Teil 1: Feldbusprofile
Réseaux de communication industriels - Profils - Partie 1: Profils pour les bus de terrain
Ta slovenski standard je istoveten z: EN 61784-1:2008
ICS:
25.040.40 Merjenje in krmiljenje Industrial process
industrijskih postopkov measurement and control
35.240.50 Uporabniške rešitve IT v IT applications in industry
industriji
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 61784-1
NORME EUROPÉENNE
June 2008
EUROPÄISCHE NORM
ICS 35.240.50; 35.100.20 Supersedes EN 61491:1998 (partially) and EN 61784-1:2004

English version
Industrial communication networks -
Profiles -
Part 1: Fieldbus profiles
(IEC 61784-1:2007)
Réseaux de communication industriels -  Industrielle Kommunikationsnetze -
Profils - Profile -
Partie 1: Profils pour les bus de terrain Teil 1: Feldbusprofile
(CEI 61784-1:2007) (IEC 61784-1:2007)

This European Standard was approved by CENELEC on 2008-05-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61784-1:2008 E
Foreword
The text of document 65C/294/FDIS, future edition 2 of IEC 61784-1, prepared by SC 65C, Industrial
networks, of IEC TC 65, Industrial-process measurement, control and automation, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as EN 61784-1 on 2008-05-01.
This European Standard supersedes EN 61784-1:2004 + corrigendum December 2004.
This standard also partially replaces EN 61491:1998 which is at present being revised (to be issued as a
Technical Report).
– partition of EN 61158 Parts 3, 4 ,5, and 6 into multiple parts numbered for example EN 61158-6-1,
-6-2, -6-3, …;
– deletion of Type 6 fieldbus in EN 61158 series and CPF 7 for lack of market relevance;
– addition of new types of fieldbuses in EN 61158 series leading to new CPF 8, 9, and 16.
The following dates were fixed:

– latest date by which the EN has to be implemented

at national level by publication of an identical
(dop) 2009-02-01
national standard or by endorsement

– latest date by which the national standards conflicting
(dow) 2011-05-01
with the EN have to be withdrawn
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61784-1:2007 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60793 NOTE Harmonized in EN 60793 series (partially modified).
IEC 61131-3 NOTE Harmonized as EN 61131-3:2003 (not modified).
ISO/IEC 9506-1 NOTE Harmonized as EN ISO/IEC 29506-1:1993 (not modified).
ISO/IEC 9506-2 NOTE Harmonized as EN ISO/IEC 29506-2:1990 (not modified).
__________
- 3 - EN 61784-1:2008
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

1) 2)
IEC 60079-11 - Explosive atmospheres - EN 60079-11 2007
Part 11: Equipment protection by intrinsic
safety "i"
IEC 60079-14 2002 Electrical apparatus for explosive gas EN 60079-14 2003
atmospheres -
Part 14: Electrical installations in hazardous
areas (other than mines)
1) 2)
IEC 60079-25 - Electrical apparatus for explosive gas EN 60079-25 2004
atmospheres - + corr. April 2006
Part 25: Intrinsically safe systems

1)
IEC 60079-27 - Explosive atmospheres - EN 60079-27 2008
Part 27: Fieldbus intrinsically safe concept
(FISCO)
IEC 61010 Series Safety requirements for electrical equipment EN 61010 Series
for measurement, control, and laboratory
use
1)
IEC 61131-2 - Programmable controllers - EN 61131-2 2007
Part 2: Equipment requirements and tests

IEC 61158 Series Industrial communication networks - EN 61158 Series
Fieldbus specifications
1)
IEC 61784-2 - Industrial communication networks - EN 61784-2 2008
Profiles -
Part 2: Additional fieldbus profiles for real-time
networks based on ISO/IEC 8802-3

1)
IEC 61784-5-2 - Industrial communication networks - EN 61784-5-2 2008
Profiles -
Part 5-2: Installation of fieldbuses - Installation
profiles for CPF 2
1)
IEC 61918 (mod) - Industrial communication networks - EN 61918 2008
Installation of communication networks in
industrial premises
1) 3)
IEC 62026-3 - Low-voltage switchgear and controlgear - EN 62026-3 -
Controller-device interfaces (CDIs) -
Part 3: DeviceNet
1)
Undated reference.
2)
Valid edition at date of issue.
3)
At draft stage.
Publication Year Title EN/HD Year

1) 2)
ISO/IEC 7498-1 - Information technology - Open Systems EN ISO/IEC 7498-1 1995
Interconnection - Basic Reference Model:
The Basic Model
1)
ISO/IEC 7498-2 - Information processing systems - Open - -
systems interconnection - Basic reference
model -
Part 2: Security architecture
1)
ISO/IEC 7498-3 - Information technology - Open systems - -
interconnection - Basic reference model -
Part 3: Naming and addressing
ISO/IEC 8802-2 1998 Information technology - Telecommunications - -
and information exchange between systems -
Local and metropolitan area networks -
Specific requirements -
Part 2: Logical link control
ISO/IEC 8802-3 2000 Information technology - Telecommunications - -
and information exchange between systems -
Local and metropolitan area networks -
Specific requirements -
Part 3: Carrier sense multiple access with
collision detection (CSMA/CD) access method
and physical layer specifications

1)
ISO 11898-1 - Road vehicles - Controller area network - -
(CAN) -
Part 1: Data link layer and physical signalling

1)
ISO 11898-2 - Road vehicles - Controller area network - -
(CAN) -
Part 2: High-speed medium access unit

1)
ISO 15745-3 - Industrial automation systems and - -
integration - Open systems application
integration framework -
Part 3: Reference description for IEC 61158
based control systems
ISO 15745-4 2003 Industrial automation systems and - -
A1 2006 integration - Open systems application
integration framework -
Part 4: Reference description for Ethernet-
based control systems
ANSI TIA/EIA-232-F 1997 Interface between data terminal equipment - -
and data circuit - Terminating equipment
employing serial binary data interchange

ANSI TIA/EIA-422-B 1994 Electrical characteristics of balanced voltage - -
digital interface circuits
ANSI TIA/EIA-485-A 1998 Electrical Characteristics of Generators and - -
Receivers for Use in Balanced Digital
Multipoint Systems
IEEE 802.3 2002 IEEE Standard for Information technology - - -
Telecommunications and information
exchange between systems - Local and
metropolitan area networks - Specific
requirements -
Part 3: Carrier Sense Multiple Access with
Collision Detection (CSMA/CD) - Access
Method and Physical Layer Specifications

- 5 - EN 61784-1:2008
Publication Year Title EN/HD Year

1)
IETF RFC - Internet Engineering Task Force - Request - -
for Comments
1)
IETF RFC 768 - User Datagram Protocol - -

1)
IETF RFC 791 - Internet Protocol - DARPA Internet Program - -
Protocol Specification
1)
IETF RFC 792 - Internet Control Message Protocol - DARPA - -
Internet Program Protocol Specification

1)
IETF RFC 793 - Transmission Control Protocol - DARPA - -
Internet Program Protocol Specification

1)
IETF RFC 826 - Ethernet Address Resolution Protocol - - -
Converting Network Protocol Addresses to
48.bit Ethernet Address for Transmission on
Ethernet Hardware
1)
IETF RFC 894 - Standard for the Transmission of IP - -
Datagrams over Ethernet Networks

1)
IETF RFC 1112 - Host Extensions for IP Multicasting - -

1)
IETF RFC 1122 - Requirements for Internet Hosts - - -
Communication Layers
1)
IETF RFC 1123 - Requirements for Internet Hosts - Application - -
and Support
1)
IETF RFC 1127 - A Perspective on the Host Requirements - -
RFCs
1)
IETF RFC 2236 - Internet Group Management Protocol - - -
Version 2
IEC 61784-1
Edition 2.0 2007-12
INTERNATIONAL
STANDARD
Industrial communication networks – Profiles –
Part 1: Fieldbus profiles
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
XL
ICS 35.240.50; 35.100.20 ISBN 2-8318-9378-X

– 2 – 61784-1 © IEC:2007(E)
CONTENTS
FOREWORD.12
INTRODUCTION.14
1 Scope.15
2 Normative references .16
3 Definitions .18
3.1 Terms and definitions .18
3.2 Abbreviations and symbols.18
3.3 Conventions .19
4 Conformance to communication profiles .21
5 Communication Profile Family 1 (FOUNDATION® Fieldbus) .22
5.1 General overview .22
5.2 Profile 1/1 (FF H1).23
5.3 Profile 1/2 (FF HSE) .105
5.4 Profile 1/3 (FF H2).106
6 Communication Profile Family 2 (CIP™).109
6.1 General overview .109
6.2 Profile 2/1 (ControlNet) .110
6.3 Profile 2/2 (EtherNet/IP) .113
6.4 Profile 2/3 (DeviceNet) .115
7 Communication Profile Family 3 (PROFIBUS & PROFINET) .119
7.1 General overview .119
7.2 Profile 3/1 (PROFIBUS DP) .120
7.3 Profile 3/2 (PROFIBUS PA) .188
7.4 Profile 3/3 (PROFINET CBA) .201
8 Communication Profile Family 4 (P-NET®) .203
8.1 General overview .203
8.2 Profile 4/1 (P-NET RS-485) .203
8.3 Profile 4/2 (P-NET RS-232) .206
9 Communication Profile Family 5 (WorldFIP®) .208
9.1 General overview .208
9.2 Profile 5/1 (WorldFIP).209
9.3 Profile 5/2 (WorldFIP).217
9.4 Profile 5/3 (WorldFIP).222
10 Communication Profile Family 6 (INTERBUS®) .223
10.1 General overview .223
10.2 Profile 6/1 .224
10.3 Profile 6/2 .227
10.4 Profile 6/3 .230
11 Communication Profile Family 7 (This Clause has been removed) . 232
12 Communication Profile Family 8 (CC-Link) .232
12.1 General overview .232
12.2 Profile 8/1 .233
12.3 Profile 8/2 .239
12.4 Profile 8/3 .239

61784-1 © IEC:2007(E) – 3 –
13 Communication Profile Family 9 (HART).245
13.1 General Overview.245
13.2 Profile 9/1, universal command .245
14 Communication Profile Family 16 (SERCOS).247
14.1 General overview .247
14.2 Profile 16/1 (SERCOS I).247
14.3 Profile 16/2 (SERCOS II).249
Annex A (informative) Communication concepts .251
A.1 CPF 1 (FOUNDATION Fieldbus) communication concepts. 251
A.2 CPF 2 (CIP) communication concepts .252
A.3 CPF 3 (PROFIBUS & PROFINET) communication concepts . 255
A.4 CPF 4 (P-NET) communication concepts .257
A.5 CPF 5 (WorldFIP) communication concepts.259
A.6 CPF 6 (INTERBUS) communication concepts .260
A.7 CPF 8 (CC-LINK) communication concepts.261
A.8 CPF 9 (HART) communication concepts .262
A.9 CPF 16 (SERCOS) communication concepts .262
Annex B (informative) Added value of IEC 61784-1.265

Bibliography.266

Figure 1 — Communication profile families and profiles .15
Figure 2 — Example optical power budget for a 100/140 μm fibre system with a 16/16
optical passive star coupler.37
Figure 3 — CP 3/2 Slave devices usable in applications . 120
Figure A.1 — Ring structure.263
Figure A.2 — Topology example .263

Table 1 — Relations of Communication Profile Families to type numbers.
Table 2 — Layout of profile (sub)clause selection tables.19
Table 3 — Contents of (sub)clause selection tables.19
Table 4 — Layout of service selection tables .20
Table 5 — Contents of service selection tables.20
Table 6 — Layout of parameter selection tables.20
Table 7 — Contents of parameter selection tables .20
Table 8 — Layout of class attribute selection tables.21
Table 9 — Contents of class attribute selection tables .21
Table 10 — CPF 1: overview of profile sets .23
Table 11 — CP 1/1: PhL selection for communicating devices and their MAUs .23
Table 12 — CP 1/1: PhL classification of MAUs and attached devices .25
Table 13 — CP 1/1: PhL selection of Clause 16 for devices and their MAUs .25
Table 14 — CP 1/1: PhL selection of Clause 12 for devices and their MAUs .26
Table 15 — CP 1/1: PhL selection of Clause 21 for devices and their MAUs
(denigrated) .27

– 4 – 61784-1 © IEC:2007(E)
Table 16 — CP 1/1: PhL selection of recommended IS parameters for FF MAU classes
111, 112, 121, 122, 511 and 512 .28
Table 17 — CP 1/1: PhL selection for media components .29
Table 18 — CP 1/1: PhL selection of imperative IS parameters for media in FISCO
systems .29
Table 19 — CP 1/1: PhL selection for power supplies .30
Table 20 — CP 1/1: PhL selection of power supply types.30
Table 21 — CP 1/1: PhL selection of permissible output voltage and IS parameters for
FISCO power supplies .31
Table 22 — CP 1/1: PhL selection for terminators.32
Table 23 — CP 1/1: PhL selection of IS parameters for terminators .32
Table 24 — CP 1/1: PhL selection of Clause 12 for intrinsic safety barriers .33
Table 25 — CP 1/1: PhL selection of recommended IS parameters for intrinsic safety
barriers and galvanic isolators (Entity model only) .34
Table 26 — CP 1/1: PhL selection of Clause 12 for intrinsically safe galvanic isolators.35
Table 27 — CP 1/1: PhL selection of Clause 15, recommended optical fibre types.36
Table 28 — CP 1/1: PhL selection of passive star couplers, recommended maximum
insertion loss .36
Table 29 — CP 1/1: PhL selection of active star couplers .36
Table 30 — CP 1/1: Optical power budget considerations .37
Table 31 — CP 1/1: DLL service selection .38
Table 32 — CP 1/1: DLL service selection of Clause 5 .38
Table 33 — CP 1/1: DLL service selection of 5.4 .38
Table 34 — CP 1/1: DLL service selection of 5.4.1 .38
Table 35 — CP 1/1: DLL service selection of 5.4.3 .39
Table 36 — CP 1/1: DLL service selection of 5.4.6 .39
Table 37 — CP 1/1: DLL service selection of Clause 6 .40
Table 38 — CP 1/1: DLL service selection of the summary of 6.3, DL-connection QoS .40
Table 39 — CP 1/1: DLL service selection of figures 11—16 of 6.4.41
Table 40 — CP 1/1: DLL service selection of 6.5 .41
Table 41 — CP 1/1: DLL service selection: replacement for Table 13 of 6.5.42
Table 42 — CP 1/1: DLL service selection of 6.5, replacement for Table 14.42
Table 43 — CP 1/1: DLL service selection of 6.5 for use of addresses for peer DLC.43
Table 44 — CP 1/1: DLL service selection of 6.5 for use of addresses for multipeer
DLC connect request at publisher .43
Table 45 — CP 1/1: DLL service selection of 6.5 for use of addresses for multipeer
DLC connect request at subscriber .43
Table 46 — CP 1/1: DLL service selection of 6.6 .43
Table 47 — CP 1/1: DLL service selection: replacement for Table 15 of 6.6.44
Table 48 — CP 1/1: DLL service selection of 6.7 .44
Table 49 — CP 1/1: DLL service selection of 6.7, replacement for Table 16.44
Table 50 — CP 1/1: DLL service selection of 6.7, replacement for Table 17.44
Table 51 — CP 1/1: DLL service selection of 6.7, replacement for Table 18.45
Table 52 — CP 1/1: DLL service selection of Clause 7 .45
Table 53 — CP 1/1: DLL service selection of 7.5, replacement for Table 23.46

61784-1 © IEC:2007(E) – 5 –
Table 54 — CP 1/1: DLL service selection of Clause 8 .46
Table 55 — CP 1/1: DLL service selection of 8.5, replacement for Table 28.46
Table 56 — CP 1/1: DLL protocol selection.47
Table 57 — CP 1/1: DLL protocol selection of Clause 4 .47
Table 58 — CP 1/1: DLL protocol selection of 4.3 .48
Table 59 — CP 1/1: DLL protocol selection of 4.3.2.1 for use of link designators .48
Table 60 — CP 1/1: DLL protocol selection of 4.3.2.2 for use of node designators.48
Table 61 — CP 1/1: DLL protocol selection of 4.3.3.1 for predefined flat non—local
DL-addresses .48
Table 62 — CP 1/1: DLL protocol selection of 4.3.3.2 for predefined flat link—local
DL-addresses .49
Table 63 — CP 1/1: DLL protocol selection of 4.3.3.3 for predefined node—local
DL-addresses .49
Table 64 — CP 1/1: DLL protocol selection of 4.7 .50
Table 65 — CP 1/1: DLL protocol selection of 4.7.4 .51
Table 66 — CP 1/1: DLL protocol selection of 4.7.5 .52
Table 67 — CP 1/1: DLL protocol selection of Clause 6 .53
Table 68 — CP 1/1: DLL protocol selection, replacement for Table 10 of 6.0 .54
Table 69 — CP 1/1: DLL protocol selection of 6.5 .55
Table 70 — CP 1/1: DLL protocol selection of 6.7 .58
Table 71 — CP 1/1: DLL protocol selection of 6.8 .62
Table 72 — CP 1/1: DLL protocol selection of 6.11 .63
Table 73 — CP 1/1: DLL protocol selection of 6.12 .63
Table 74 — CP 1/1: DLL protocol selection of 6.15 .64
Table 75 — CP 1/1: DLL protocol selection of 6.20 .65
Table 76 — CP 1/1: DLL protocol selection of Clause 7 .66
Table 77 — CP 1/1: DLL protocol selection of 7.4 .67
Table 78 — CP 1/1: DLL protocol selection of Clause 8 .68
Table 79 — CP 1/1: DLL protocol selection of 8.2 .69
Table 80 — CP 1/1: DLL protocol selection of 8.2.2 .79
Table 81 — CP 1/1: DLL protocol selection of 8.3 .92
Table 82 — CP 1/1: DLL protocol selection of 8.4 .92
Table 83 — CP 1/1: DLL protocol selection of Clause 9 .93
Table 84 — CP 1/1: DLL protocol selection of 9.3 .94
Table 85 — CP 1/1: DLL protocol selection of 9.3.5 .96
Table 86 — CP 1/1: DLL protocol selection of 9.3.5.2.2, replacement for element
encoding.97
Table 87 — CP 1/1: DLL protocol selection of Clause 10 .97
Table 88 — CP 1/1: DLL protocol selection of 10.2 .98
Table 89 — CP 1/1: DLL protocol selection of 10.3 .99
Table 90 — CP 1/1: DLL protocol selection of 10.3.7, specification of errors. 101
Table 91 — CP 1/1: DLL protocol selection of 10.4 .102
Table 92 — CP 1/1: DLL protocol selection of 10.5 .103
Table 93 — CP 1/1: DLL protocol selection of 10.6 .103

– 6 – 61784-1 © IEC:2007(E)
Table 94 — CP 1/1: AL service selection .104
Table 95 — CP 1/1: AL data type selection of Clause 4 .104
Table 96 — CP 1/1: AL protocol selection.105
Table 97 — CP 1/2: AL service selection .106
Table 98 — CP 1/2: AL protocol selection.106
Table 99 — CP 1/3: PhL selection for FF H2 devices .107
Table 100 — CP 1/3: PhL selection for FF H2 media and related components .108
Table 101 — CP 2/1: PhL selection .110
Table 102 — CP 2/1: DLL service selection .111
Table 103 — CP 2/1: DLL protocol selection.111
Table 104 — CP 2/1: DLL protocol selection of management objects. 111
Table 105 — CP 2/1: AL service selection .112
Table 106 — CP 2/1: AL protocol selection .112
Table 107 — CP 2/2: DLL protocol selection.113
Table 108 — CP 2/2: DLL protocol selection of management objects. 114
Table 109 — CP 2/2: AL service selection .114
Table 110 — CP 2/2: AL protocol selection .115
Table 111 — CP 2/3: DLL protocol selection.116
Table 112 — CP 2/3: DLL protocol selection of management objects. 116
Table 113 — CP 2/3: AL service selection .117
Table 114 — CP 2/3: AL protocol selection .118
Table 115 — CPF 3: overview of profile sets.119
Table 116 — CP 3/1: PhL selection .121
Table 117 — CP 3/1: PhL selection of Clause 3.122
Table 118 — CP 3/1: PhL selection of Clause 4.122
Table 119 — CP 3/1: General DLL service selection .123
Table 120 — CP 3/1: DLL service selection for DP-V0 master (class 1) . 123
Table 121 — CP 3/1: DLM service selection for DP-V0 master (class 1) . 124
Table 122 — CP 3/1: DLL service selection for DP-V1 master (class 1) . 125
Table 123 — CP 3/1: DLM service selection for DP-V1 master (class 1) . 126
Table 124 — CP 3/1: DLL service selection for DP-V0 master (class 2) . 126
Table 125 — CP 3/1: DLL service selection for DP-V1 master (class 2) . 127
Table 126 — CP 3/1: DLL service selection for DP-V0 slave. 128
Table 127 — CP 3/1: DLM service selection for DP-V0 slave . 129
Table 128 — CP 3/1: DLL service selection for DP-V1 slave. 130
Table 129 — CP 3/1: DLM service selection for DP-V1 slave . 131
Table 130 — CP 3/1: General DLL protocol selection.131
Table 131 — CP 3/1: DLL protocol selection of Clause 5 . 132
Table 132 — CP 3/1: DLL protocol selection of Clause 6 . 132
Table 133 — CP 3/1: DLL protocol selection of Clause 7 . 133
Table 134 — CP 3/1: Time variable selection for DP-V0 master (class 1). 133
Table 135 — CP 3/1: Timer and counter selection for DP-V0 master (class 1) . 134
Table 136 — CP 3/1: DLPDU selection for DP-V0 master (class 1) .134

61784-1 © IEC:2007(E) – 7 –
Table 137 — CP 3/1: MAC state selection for DP-V0 master (class 1) . 134
Table 138 — CP 3/1: Time selection for DP-V1 master (class 1). 135
Table 139 — CP 3/1: Timer and counter selection for DP-V1 master (class 1) . 135
Table 140 — CP 3/1: DLPDU selection for DP-V1 master (class 1) .136
Table 141 — CP 3/1: MAC state selection for DP-V1 master (class 1) . 136
Table 142 — CP 3/1: CS protocol selection for DP-V1 master (class 1) . 136
Table 143 — CP 3/1: Time selection for DP-V1 master (class 2). 137
Table 144 — CP 3/1: Timer and counter selection for DP-V1 master (class 2) . 137
Table 145 — CP 3/1: DLPDU selection for DP-V1 master (class 2) .138
Table 146 — CP 3/1: Time selection for DP-V0 slave.138
Table 147 — CP 3/1: Timer and counter selection for DP-V0 slave .139
Table 148 — CP 3/1: DLPDU selection for DP-V0 slave.139
Table 149 — CP 3/1: MAC state selection for DP-V0 slave .139
Table 150 — CP 3/1: Time selection for DP-V1 slave.140
Table 151 — CP 3/1: Timer and counter selection for DP-V1 slave .140
Table 152 — CP 3/1: DLPDU selection for DP-V1 slave.141
Table 153 — CP 3/1: CS protocol selection for DP-V1 slave .141
Table 154 — CP 3/1, 3/2: AL service selection .141
Table 155 — CP 3/1, 3/2: AL service selection of data types . 142
Table 156 — CP 3/1, 3/2: AL service selection of Clause 6. 143
Table 157 — CP 3/1, 3/2: AL service selection of I/O data ASE . 144
Table 158 — CP 3/1, 3/2: AL service selection of Diagnosis ASE . 144
Table 159 — CP 3/1, 3/2: AL service selection of Context ASE. 145
Table 160 — CP 3/1, 3/2: AL service selection of Management ASE. 145
Table 161 — CP 3/1, 3/2: AL service selection of AR ASE . 146
Table 162 — CP 3/1, 3/2: AL service selection of Clause 6. 147
Table 163 — CP 3/1, 3/2: AL service selection of Process data ASE . 147
Table 164 — CP 3/1, 3/2: AL service selection of I/O data ASE . 147
Table 165 — CP 3/1, 3/2: AL service selection of Alarm ASE. 148
Table 166 — CP 3/1, 3/2: AL service selection of Context ASE. 148
Table 167 — CP 3/1, 3/2: AL service selection of Load region ASE . 148
Table 168 — CP 3/1, 3/2: AL service selection of Function invocation ASE. 148
Table 169 — CP 3/1, 3/2: AL service selection of Time ASE . 149
Table 170 — CP 3/1, 3/2: AL service selection of AR ASE . 149
Table 171 — CP 3/1, 3/2: AL service selection of Clause 6. 150
Table 172 — CP 3/1, 3/2: AL service selection of I/O data ASE . 150
Table 173 — CP 3/1, 3/2: AL service selection of Diagnosis ASE . 151
Table 174 — CP 3/1, 3/2: AL service selection of Context ASE. 151
Table 175 — CP 3/1, 3/2: AL service selection of Management ASE. 151
Table 176 — CP 3/1, 3/2: AL service selection of AR ASE . 152
Table 177 — CP 3/1, 3/2: AL service selection of Clause 6. 153
Table 178 — CP 3/1, 3/2: AL service selection of Process data ASE . 153
Table 179 — CP 3/1, 3/2: AL service selection of Context ASE. 153

– 8 – 61784-1 © IEC:2007(E)
Table 180 — CP 3/1, 3/2: AL service selection of Load region ASE . 154
Table 181 — CP 3/1, 3/2: AL service selection of Function invocation ASE. 154
Table 182 — CP 3/1, 3/2: AL service selection of Time ASE . 154
Table 183 — CP 3/1, 3/2: AL service selection of AR ASE . 155
Table 184 — CP 3/1, 3/2: AL service selection of Clause 6. 156
Table 185 — CP 3/1, 3/2: AL service selection of I/O data ASE . 156
Table 186 — CP 3/1, 3/2: AL service selection of Diagnosis ASE . 157
Table 187 — CP 3/1, 3/2: AL service selection of Context ASE. 157
Table 188 — CP 3/1, 3/2: AL service selection of AR ASE . 158
Table 189 — CP 3/1, 3/2: AL service selection of Clause 6. 159
Table 190 — CP 3/1, 3/2: AL service selection of Process data ASE . 159
Table 191 — CP 3/1, 3/2: AL service selection of I/O data ASE . 159
Table 192 — CP 3/1, 3/2: AL service selection of diagnosis ASE . 160
Table 193 — CP 3/1, 3/2: AL service selection of Alarm ASE. 160
Table 194 — CP 3/1, 3/2: AL service selection of Context ASE. 161
Table 195 — CP 3/1, 3/2: AL service selection of Load region ASE . 161
Table 196 — CP 3/1, 3/2: AL service selection of Function invocation ASE. 162
Table 197 — CP 3/1, 3/2: AL service selection of Time ASE . 162
Table 198 — CP 3/1, 3/2: AL service selection of AR ASE . 163
Table 199 — CP 3/1, 3/2: AL protocol selection .164
Table 200 — CP 3/1, 3/2: AL protocol selection of Clause 4 to 11. 165
Table 201 — CP 3/1, 3/2: AL protocol selection of APDUs . 166
Table 202 — CP 3/1, 3/2: AL protocol selection of FSPM services primitives . 167
Table 203 — CP 3/1, 3/2: AL protocol selection of DMPM services primitives . 167
Table 204 — CP 3/1, 3/2: AL protocol selection of Clause 4 to 11. 168
Table 205 — CP 3/1, 3/2: AL protocol selection of APDUs . 170
Table 206 — CP 3/1, 3/2: AL protocol selection of FSPM services primitives . 171
Table 207 — CP 3/1, 3/2: AL protocol selection of DMPM services primitives . 172
Table 208 — CP 3/1, 3/2: AL protocol selection of Clause 4 to 6. 172
Table 209 — CP 3/1, 3/2: AL protocol selection of APDUs . 174
Table 210 — CP 3/1, 3/2: AL protocol selection of FSPM services primitives . 174
Table 211 — CP 3/1, 3/2: AL protocol selection of DMPM services primi
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...