FprEN IEC 55032:2026
(Main)Electromagnetic compatibility of multimedia equipment - Emission requirements
- Status
- Not Published
- Publication Date
- 10-Mar-2027
- Technical Committee
- CLC/TC 210 - Electromagnetic Compatibility (EMC)
- Current Stage
- 5020 - Vote circulated - Formal Approval
- Start Date
- 30-Oct-2026
- Due Date
- 11-Sep-2026
- Completion Date
- 11-Sep-2026
FprEN IEC 55032:2026 is a CLC draft of the IEC/CISPR standard for electromagnetic compatibility of multimedia equipment. It specifies emission requirements and measurement methods for multimedia equipment (MME) with rated r.m.s. AC or DC supply voltage up to 600 V, including professional-use equipment, battery-powered equipment, and equipment with radio functions. It is written for manufacturers, test laboratories, quality teams, and buyers who need to assess conducted and radiated emissions and document Class A or Class B compliance.
What does FprEN IEC 55032:2026 specify?
FprEN IEC 55032:2026 specifies how to classify MME, how to measure its emissions, and how to document the results. The standard is organized into clauses 1 to 11, with normative annexes A to D, H, and L, plus informative annexes E, F, G, I, J, K, M, and N.
| Annex | What it covers |
|---|---|
| Annex A | Normative emission requirements and limit tables for radiated and conducted emissions |
| Annex B | How to exercise the EUT and what test signals to apply |
| Annex C | Measurement procedures, instrumentation, and supporting information |
| Annex D | Arrangement of the EUT, local AE, and cabling |
| Annex E | Prescan measurements |
| Annex F | Test report contents summary |
| Annex G | Supporting information for C.4.1.1, including artificial networks and rationale |
| Annex H | Outdoor units of home satellite broadcast receiving systems |
| Annex I | Alternative radiated-emission methods and limits using GTEM |
| Annex J | Colour bar image |
| Annex K | Guidance for MME with radiocommunication or radiodetermination functionality |
| Annex L | In situ measurement |
| Annex M | Explanation of the changes above 1 GHz in CISPR 32 Edition 2 Amendment 1 |
| Annex N | Use of VHF-LISN for radiated emission measurements |
Clause 1 limits the scope to MME within the stated supply voltage range and excludes emissions that are exclusively from a radiocommunication or radiodetermination function. Clause 2 points to the CISPR 16 measurement family, and the rest of the document builds the test conditions around those basic standards.
What are the key requirements of FprEN IEC 55032:2026?
FprEN IEC 55032:2026 sets out the emission limits, the test setup, the operating modes to exercise, and the reporting detail needed to show compliance. In practice, the document is not just a limit table - it tells you how to run the EUT so that the worst-case emissions are found and recorded.
1) The document uses two equipment classes
Clause 4 classifies equipment as Class A or Class B, and Annex A provides separate limit tables for each class. This matters because the applicable limit set changes with the intended environment, so the first compliance decision is whether the product is being assessed against Class A or Class B requirements.
2) Annex A contains the emission limits for radiated and conducted tests
Annex A gives the normative requirements for radiated emissions and conducted emissions. The tables cover frequencies below and above 1 GHz, with different limits for OATS/SAC, FAR, ALTS, and RVC methods where applicable.
For conducted emissions, Annex A covers AC mains power ports, asymmetric mode emissions from wired network, optical fibre, antenna, and broadcast tuner ports, differential voltage emissions from certain Class B ports, and DC network power ports. For the reader, this means the document is not a single generic emission limit - the limit depends on the port type, the class, and the measurement method used.
3) Clause 6 and Annex C define how measurements are made
Clause 6 sets out the general measurement framework, including host systems, modular EUTs, measurement procedures, in situ measurements, equipment documentation, applicability, test report content, compliance, and measurement instrumentation uncertainty. Annex C then gives the detailed procedures for prescan, formal measurement, and the different port-specific methods.
This is important in practice because compliance depends on using the correct setup, detector, coupling device, and measurement sequence, not only on reading a limit table.
4) Annex B defines how to exercise the EUT
Annex B requires the EUT to be operated in representative modes, including low power or standby where relevant, and the modes that produce the highest emissions are selected for formal testing. It also requires all functions or groups of functions to be considered, and ports to be exercised with appropriate signals.
For displays and video ports, Annex B points to standardized images such as colour bars, text images, and the most complex display the EUT can generate. For network ports, the annex requires operation with the relevant physical-layer transmission technology, typically at the highest supported data rate. This matters because emissions often change with operating state, load, and traffic pattern.
5) Port-specific methods are used for wired, broadcast, and RF-related ports
Annex C gives different measurement procedures for different port families. It includes AMN, AAN, C-AN, CP, and CVP methods, plus special procedures for broadcast receiver tuner ports and RF modulator output ports.
One practical example is the treatment of unscreened balanced pair wired network ports. For some transmission technologies, the standard allows alternative methods when the power spectral density conditions and wanted-signal conditions are met. This gives test laboratories a structured way to choose a method that still represents normal use.
6) The document controls the physical arrangement of the test
Annex D specifies how to arrange the EUT, local AE, and cabling for table-top, floor-standing, combined, FAR, and RVC setups. It gives spacing, height, and cabling guidance so that the setup is repeatable and the measured emissions are representative.
In practice, this is where the standard turns the limit table into a testable arrangement. If the arrangement is wrong, the measured result may not be valid for compliance purposes.
7) Special cases are handled in dedicated annexes
Annex H covers outdoor units of home satellite broadcast receiving systems, including special treatment near and outside the ±7° main beam axis. Annex I gives GTEM-based radiated-emission methods and associated limits. Annex L provides in situ measurement methods for conducted and radiated emissions, which is useful when a laboratory setup is not practical.
These annexes matter because some products need a different measurement geometry or a field installation test rather than a conventional chamber test.
8) The report has to show reproducibility and uncertainty
Clause 9 requires enough detail to reproduce the measurement, including the mode of operation, the port exercise method, the test method used, the limits applied, and the compliance class. It also requires the highest emissions relevant to each detector type and the measurement instrumentation uncertainty for each measurement type.
For users of the standard, that means the report must support a real compliance decision, not just list a pass/fail statement.
What terms does FprEN IEC 55032:2026 define?
- multimedia equipment (MME) - Equipment within the scope of the standard, including professional-use, battery-powered, and radio-function equipment when the supply voltage is within the stated range.
- equipment under test (EUT) - The product being configured, exercised, and measured during compliance testing.
- associated equipment (AE) - The external equipment used with the EUT during testing, such as signal sources or support equipment needed for normal operation.
- artificial mains network (AMN) - The coupling device used to measure conducted emissions from AC mains power ports.
- asymmetric artificial network (AAN) - A network used for measuring asymmetric or common-mode emissions on certain wired or screened ports.
- capacitive voltage probe (CVP) - A probe used in the port measurement procedures, especially where voltage and current are assessed together.
- GTEM - A gigahertz transverse electromagnetic setup used as an alternative radiated-emission test method in Annex I.
Who uses FprEN IEC 55032:2026?
FprEN IEC 55032:2026 is used by EMC engineers, test laboratories, product compliance teams, quality managers, and manufacturers of multimedia equipment. It is also relevant to buyers and certification teams who need to know whether a product has been tested against Class A or Class B emission requirements.
The document is especially relevant for products with wired network ports, display and video functions, broadcast receiver tuner ports, RF modulator output ports, DC network power ports, or radio functionality. It is used when planning design verification, pre-compliance testing, formal EMC testing, and conformity assessment.
What changed in FprEN IEC 55032:2026 from the previous edition?
FprEN IEC 55032:2026 is described as a third edition technical revision. The foreword lists these significant technical changes:
- numerous maintenance items to improve the testing of MME
- alignment and update of the Scope
- incorporation of in situ methods and requirements
- revision of TV tuner port requirements
- inclusion of APD methods and limits
- inclusion of conducted requirements below 950 MHz for satellite broadcast receiver tuner ports
- editorial improvements and corrections from Edition 2 Amendment 1
- DC network port requirements
- testing MME with radio function
- an informative annex explaining the changes above 1 GHz in Edition 2 Amendment 1
- an informative annex on the use of a VHF-LISN to improve test reproducibility
- update of references to the latest basic standards
- conversion of the RVC methodology from informative to normative
Which standards are used with FprEN IEC 55032:2026?
FprEN IEC 55032:2026 relies on the CISPR 16 series for measurement apparatus, coupling devices, antennas, test sites, calibration, disturbance measurement methods, and uncertainty:
- CISPR 16-1-1 - measuring apparatus
- CISPR 16-1-2 - coupling devices for conducted disturbance measurements
- CISPR 16-1-4 - antennas and test sites for radiated disturbance measurements
- CISPR 16-1-5 - antenna calibration sites and reference test sites
- CISPR 16-1-6 - EMC antenna calibration
- CISPR 16-2-1 - conducted disturbance measurement methods
- CISPR 16-2-3 - radiated disturbance measurement methods
- CISPR 16-4-2 - measurement instrumentation uncertainty
Annex I also uses IEC 61000-4-20 for GTEM-related guidance, Annex L uses IEC 61000-4-21 for reverberation chamber considerations, and Annex C refers to IEC 61000-4-6:2023 for the 150 Ω to 50 Ω adaptor used in one measurement option. These references matter because they define the test hardware and methods that make the emission results comparable across laboratories.
What does the FprEN IEC 55032:2026 document contain?
FprEN IEC 55032:2026 contains limit tables, measurement procedures, setup diagrams, detector selection logic, port exercise methods, and report content guidance. It includes worked measurement arrangements for table-top and floor-standing equipment, host systems and modular EUTs, and examples for radiated and conducted tests.
It also includes technical figures and tables for artificial networks, common-mode impedance, broadcast tuner testing, RF modulator output testing, GTEM setups, and the special arrangements for outdoor satellite receiving units. For a test lab, the practical value is that the document tells you how to configure the product, how to measure it, and what to record so the result can be defended and repeated.
Relations
- Effective Date
- 20-Feb-2024
- Effective Date
- 20-Feb-2024
- Effective Date
- 20-Feb-2024
- Revises
EN 55032:2015 - Electromagnetic compatibility of multimedia equipment - Emission Requirements - Effective Date
- 20-Feb-2024
- Effective Date
- 20-Feb-2024
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
FprEN IEC 55032:2026 is a draft published by CLC. Its full title is "Electromagnetic compatibility of multimedia equipment - Emission requirements". This standard covers: Electromagnetic compatibility of multimedia equipment - Emission requirements
Electromagnetic compatibility of multimedia equipment - Emission requirements
FprEN IEC 55032:2026 is classified under the following ICS (International Classification for Standards) categories: 33.100.10 - Emission. The ICS classification helps identify the subject area and facilitates finding related standards.
FprEN IEC 55032:2026 has the following relationships with other standards: It is inter standard links to EN 55032:2015/A1:2020, EN 55032:2015/FprAB:2026, EN 55032:2015/A11:2020, EN 55032:2015, EN 55032:2015/AC:2016-07. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
FprEN IEC 55032:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/30/EU, 2014/53/EU; Standardization Mandates: M/536, M/552. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
FprEN IEC 55032:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 101 H.3 Operation conditions
- 102 H.4 EUT arrangements
- 103 H.4.1 Conducted measurements (table clause A8.4)
- 104 H.4.2 Radiated measurements
- 105 Annex I (informative) Other test methods and associated limits for radiated emissions
- 106 I.1 General
- 107 I.2 Procedures for radiated emission measurements using a GTEM
- 108 I.3 Additional measurement procedure information
- 109 I.3.1 General
- 110 I.3.2 Specific considerations for radiated emission measurements using 111 a GTEM
- 112 I.4 Use of a GTEM for radiated emission measurements
- 113 I.4.1 General
- 114 I.4.2 EUT layout
- 115 I.4.3 GTEM, measurements above 1 GHz
- 116 I.4.4 Uncertainties
- 117 I.5 Reference documents
- 118 Annex J (informative) Colour bar image
- 119 J.1 Overview
- 120 J.2 Image description
- 121 J.3 Primary colour contributions and saturation
- 122 J.4 Moving element
- 123 Annex K (informative) Guidance on testing MME incorporating radiocommunication or 124 radiodetermination functionality
- 125 K.1 Introduction
- 126 K.2 MME with radio functionality
- 127 K.3 Test arrangements
- 128 Annex L (normative) In situ measurement
- 129 L.1 General
- 130 L.2 In situ conducted emission measurement
- 131 L.2.1 General
- 132 L.2.2 Mains power ports
- 133 L.2.3 Analogue/digital data ports
- 134 L.3 In situ radiated emission measurement
- 135 L.3.1 General
- 136 L.3.2 Ambient noise
- 137 Annex M (informative) Explanation of the changes to radiated electric field emission 138 requirements for frequencies above 1 GHz in CISPR 32 Edition 2 Amendment 1
- 139 M.1 Introduction
- 140 M.2 Original requirements development
- 141 M.2.1 FCC 47 CFR 15
- 142 M.2.2 Test method
- 143 M.2.3 Original 4 dB limit reduction
- 144 M.2.4 Class A limits
- 145 M.3 Problems found from the measurement of actual equipment
- 146 M.4 Solutions to the problems
- 147 M.5 CISPR 16-4-4 Model
- 148 Annex N (informative) Use of VHF-LISN for radiated emission measurements
- 149 N.1 Introduction
...