EN 132102:1996
(Main)Blank Detail Specification: Fixed multilayer ceramic surface mounting capacitors - Assessment level DZ
- BACK
- 12-Aug-1996
- 31.060.20
- CLC/TC 40XA
Blank Detail Specification: Fixed multilayer ceramic surface mounting capacitors - Assessment level DZ
Detail specification for fixed multilayer ceramic surface mounting capacitors.
Vordruck für Bauartspezifikation: Oberflächenmontierbare Vielschichtkeramik-Festkondensatoren - Qualitätsbewertungsstufe DZ
Blank detail specification: Fixed multilayer ceramic surface mounting capacitors - Assessment level DZ
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Blank detail specification: Fixed multilayer ceramic surface mounting capacitors - Assessment level DZVordruck für Bauartspezifikation: Oberflächenmontierbare Vielschichtkeramik-Festkondensatoren - Qualitätsbewertungsstufe DZBlank Detail Specification: Fixed multilayer ceramic surface mounting capacitors - Assessment level DZ31.060.20Ceramic and mica capacitorsIC
...
This May Also Interest You
IEC 60384-8:2024 is available as IEC 60384-8:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60384-8:2024 is applicable to fixed capacitors of ceramic dielectric with a defined temperature coefficient (dielectric Class 1), intended for use in electronic equipment, including leadless capacitors but excluding fixed surface mount multilayer capacitors of ceramic dielectric, which are covered by IEC 60384-21 (Class 1). Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60384-1:2021, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this document provide specific test severities and requirements of an equal or higher performance level. Further information on the conception of generic, sectional and detail specifications can be found in the Introduction of IEC 60384-1:2021. This edition includes the following significant technical changes with respect to the previous edition: a) The document has been completely restructured to comply with ISO/IEC Directives, Part 2 and to make it more useable; tables, figures and references have been revised accordingly. Annex X contains all cross-references of changes in clause/subclause numbers. b) The terms have been replaced by the letter symbols in Table 3. c) Code of temperature coefficient and tolerance of C0G, U2J have been added in Table 4, Table 6, Table 8, Table 9, Table 11, Table 13, Table 16 and Annex B. d) Annex B has been changed from informative to normative. e) Clause C.5 (Test schedule for quality conformance inspection) has been newly added to withdraw the blank detail specification: IEC 60384-8-1.
- Standard55 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Sep-2024
- 31.060.20
- CLC/TC 40XA
IEC 60384-9:2024 is available as IEC 60384-9:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60384-9:2024 is applicable to fixed capacitors of ceramic dielectric with a defined temperature coefficient (dielectric Class 2), intended for use in electronic equipment, including leadless capacitors but excluding fixed surface mount multilayer capacitors of ceramic dielectric, which are covered by IEC 60384-22 (Class 2). Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60384-1:2021 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this document provide specific test severities and requirements of an equal or higher performance level. Further information on the conception of generic, sectional and detail specifications can be found in the Introduction of IEC 60384-1:2021. This edition includes the following significant technical changes with respect to the previous edition: a) The document has been completely restructured to comply with ISO/IEC Directives, Part 2 and to make it more useable; tables, figures and references have been revised accordingly. Annex X contains all cross-references of changes in clause/subclause numbers. b) The requirements of reference temperature 25 °C have been added in Table 7, Table 9, Table 11, Table 13 and Table 15. c) The table of temperature characteristics of capacitance for the reference temperature 25 °C have been added in Table B.1, Table B.2 and Table B.3. d) Annex B has been changed from informative to normative. e) Clause C.5 (Test schedule for quality conformance inspection) has been newly added to withdraw the blank detail specification: IEC 60384-9-1.
- Standard48 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Sep-2024
- 31.060.20
- CLC/TC 40XA
- Corrigendum3 pagesEnglish and French languagesale 10% offe-Library read for×1 day
- 21-Sep-2017
- 31.060.20
- CLC/TC 40XA
IEC 60384-9:2015 is applicable to fixed capacitors of ceramic dielectric with a defined temperature coefficient (dielectric Class 2), intended for use in electronic equipment, including leadless capacitors but excluding fixed surface mount multilayer capacitors of ceramic dielectric. This fourth edition cancels and replaces the third edition published in 2005. This fourth edition is a result of maintenance activities related to the previous edition. All changes that have been agreed upon can be categorized as minor revisions.
- Standard38 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-May-2015
- 31.060.20
- CLC/TC 40XA
IEC 60384-8:2015 is applicable to fixed capacitors of ceramic dielectric with a defined temperature coefficient (dielectric Class 1), intended for use in electronic equipment, including leadless capacitors but excluding fixed surface mount multilayer capacitors of ceramic dielectric. This fourth edition cancels and replaces the third edition published in 2005. This fourth edition is a result of maintenance activities related to the previous edition. All changes that have been agreed upon can be categorized as minor revisions.
- Standard46 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-May-2015
- 31.060.20
- CLC/TC 40XA
This document specifies systems and methods for the inspection and testing of installed optical fibre cabling designed in accordance with premises cabling standards including the EN 50173 series. The test methods refer to existing standards-based procedures where they exist.
- Draft86 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Dec-2025
- 35.110
- CLC/TC 215
IEC 61169-74:2025, which is a Sectional Specification (SS), provides information and rules for the preparation of Detail Specifications (DS) for series HN RF coaxial connectors with screw coupling with a characteristic impedance of 50 Ω. This document prescribes mating face dimensions for high performance connectors (grade 2), dimensional details of standard test connectors (grade 0), gauging information and tests selected from IEC 61169-1, applicable to all Detail Specifications relating to series HN RF connectors. This document indicates recommended performance characteristics which are considered when writing a Detail Specification and it covers test schedules and inspection requirements for assessment levels M and H. The series HN connectors are intended to be used in microwave transmission systems and can be connected with all kinds of RF cables and microstrips. The operating frequency is up to 6 GHz.
- Draft21 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Dec-2025
- 33.120.30
- CLC/SR 46F
This document applies to portable residual current devices (PRCDs) for household and similar uses, consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection. They do not incorporate overcurrent protection. They are intended for single- and two-phase systems for rated currents not exceeding 16 A for rated voltages not exceeding 250 V AC, or for rated current not exceeding 32 A for rated voltages not exceeding 130 V AC to earth. They are intended to provide protection against shock hazard in case of direct contact, in addition to the protection provided by the fixed installations for the circuit downstream. PRCDs have a rated residual operating current not exceeding 0,03 A. The plug and socket-outlet parts of a PRCD are covered by the national standard of the country where the PRCD is placed on the market. If no national requirements exist, IEC 60884 1 is used. This document applies to portable devices performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. PRCDs providing an additional function of detecting faults on the supply side with a defined behaviour in case of supply failures or miswiring (PRCD-S) are also covered by this document. PRCDs are not intended to be used as parts of fixed installations. Their connecting means can be plugs, socket-outlets, terminals or cords. NOTE 1 The requirements for PRCDs are in compliance with the general requirements of IEC 60755. PRCDs are essentially intended to be operated by ordinary persons and designed not to require maintenance. NOTE 2 An integral fuse is used, if necessary, for the relevant plug and socket-outlet system. The switching contacts of the PRCDs are not intended to provide isolation, as isolation can be ensured by disconnecting the plug. The requirements of this document apply for environmental conditions as defined in 7.1. Additional requirements can be necessary for PRCDs used in locations having more severe environmental conditions. PRCDs including batteries are not covered by this document. This document does not contain additional requirements for PRCDs without earthing contacts for which specific requirements can apply. This document can, however, be used as a guide for such devices which are intended to be used with Class II appliances only.
- Draft145 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Dec-2025
- 29.120.01
- CLC/TC 23E
- Draft10 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Dec-2025
- 25.140.20
- 2006/42/EC
- M/396
- CLC/TC 116
IEC 62841-2-22:2025 applies to hand-held cut-off machines fitted with - one bonded reinforced wheel of Type 41 or Type 42; or - one or more diamond cutting wheels with peripheral gaps, if any, • having no positive rake angle; and • not exceeding 10 mm for cut-off machines other than flush cutters, power cutters and wall chasers; and with - a rated no-load speed not exceeding a peripheral speed of the wheel of 100 m/s at rated capacity; and - a rated capacity not exceeding 430 mm. NOTE 101 An example of a permitted diamond cutting wheel construction is shown in Figure 106. These tools are intended to cut materials such as metals, concrete, masonry, glass and tile. This document does not apply to: - cut-off machines that can be converted to a grinder, sander or polisher, which are covered by IEC 62841-2-3; - circular saws which are covered by IEC 62841-2-5; and - die grinders and small rotary tools which are covered by IEC 62841-2-23; - tools intended to cut wood, except for utility cutters; - cut-off machines fitted with a bonded reinforced wheel of Type 42 with a diameter exceeding 230 mm. This document is to be used in conjunction with IEC 62841-1:2014.
- Draft58 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Dec-2025
- 25.140.20
- 2006/42/EC
- M/396
- CLC/TC 116








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...