EN 61000-4-5:1995
(Main)Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
Relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to electrical and electronic equipment. Establishes a common reference for evaluating the performance of equipment when subjected to high-energy disturbances on the power and inter-connection lines.
Elektromagnetische Verträglichkeit (EMV) - Teil 4-5: Prüf- und Meßverfahren - Prüfung der Störfestigkeit gegen Stoßspannungen
Compatibilité électromagnétique (CEM) - Partie 4-5: Techniques d'essai et de mesure - Essai d'immunité aux ondes de choc
Se rapporte aux prescriptions d'immunité pour les matériels, aux méthodes d'essai et à la gamme des niveaux d'essai recommandés, vis-à-vis des ondes de choc unidirectionnelles provoquées par des surtensions dues aux transitoires de foudre et de manoeuvre. Définit plusieurs niveaux d'essai se rapportant à différentes conditions d'environnement et d'installation. Ces prescriptions sont développées pour les matériels électrique et électronique et leurs sont applicables. Etablit une référence commune d'évaluation des performances des matériels lorsque leurs lignes d'alimentation et d'interconnexion sont soumises à des perturbations de grande énergie.
Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 5: Surge immunity test (IEC 1000-4-5:1995)
General Information
- Status
- Withdrawn
- Publication Date
- 21-Mar-1995
- Technical Committee
- CLC/TC 210 - Electromagnetic Compatibility (EMC)
- Drafting Committee
- IEC/SC 77B - IEC_SC_77B
- Parallel Committee
- IEC/SC 77B - IEC_SC_77B
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Oct-2009
- Completion Date
- 01-Oct-2009
Not Harmonized89/336/EEC - Electromagnetic compatibility (EMC)
Relations
- Effective Date
- 29-Jan-2023
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Referred By
EN 61850-3:2002 - Communication networks and systems in substations - Part 3: General requirements - Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard

Intertek Testing Services NA Inc.
Intertek certification services in North America.

UL Solutions
Global safety science company with testing, inspection and certification.

ANCE
Mexican certification and testing association.
Sponsored listings
Frequently Asked Questions
EN 61000-4-5:1995 is a standard published by CLC. Its full title is "Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test". This standard covers: Relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to electrical and electronic equipment. Establishes a common reference for evaluating the performance of equipment when subjected to high-energy disturbances on the power and inter-connection lines.
Relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to electrical and electronic equipment. Establishes a common reference for evaluating the performance of equipment when subjected to high-energy disturbances on the power and inter-connection lines.
EN 61000-4-5:1995 is classified under the following ICS (International Classification for Standards) categories: 29.020 - Electrical engineering in general. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 61000-4-5:1995 has the following relationships with other standards: It is inter standard links to EN 61000-4-5:2006, EN 1643:2000, EN 14154-3:2005+A2:2011, EN 60761-1:2004, EN 61000-6-2:2005, EN 62305-4:2006, EN 61204-3:2000, EN 60947-4-1:2001, EN 61850-3:2002, EN 60947-4-2:1996, EN 60947-1:1999, EN 60945:1997, EN 60601-2-4:2003, EN 60947-4-1:1992/A2:1997, EN 60255-5:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 61000-4-5:1995 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EC, 2004/108/EU, 89/336/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 61000-4-5:1995 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-1997
1DGRPHãþD
SIST ENV 50142:1997
Electromagnetic compatibility (EMC) - Part 4: Testing and measurement
techniques - Section 5: Surge immunity test (IEC 1000-4-5:1995)
Electromagnetic compatibility (EMC) -- Part 4-5: Testing and measurement techniques -
Surge immunity test
Elektromagnetische Verträglichkeit (EMV) -- Teil 4-5: Prüf- und Meßverfahren - Prüfung
der Störfestigkeit gegen Stoßspannungen
Compatibilité électromagnétique (CEM) -- Partie 4-5: Techniques d'essai et de mesure -
Essai d'immunité aux ondes de choc
Ta slovenski standard je istoveten z: EN 61000-4-5:1995
ICS:
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
--------
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...