Water meters - Part 3: Test methods and equipment

This document applies to water meters intended for residential, commercial, light industrial and industrial use, and specifies the test parameters and the test methods for water meters, irrespective of the design technologies, as specified in EN 14154-1:2005+A2, used to meter the actual volume of clean cold potable water or heated water, flowing through a fully charged, closed conduit. These water meters shall incorporate devices, which indicate the integrated volume.
In the case where water meters having a value of Q3 > 160 m3/h, the test schedule may make provisions for modification of the Reference Conditions, to meet individual test laboratory limitations, when testing specifically for endurance or for performance under Influence Quantities.
Meters thus tested shall be marked so as to unambiguously indicate part compliance with this document. To augment this marking the meter manufacturer shall, in addition, be obliged to fully disclose the specific non compliance(s) due to the test laboratory limitations.

Wasserzähler - Teil 3: Prüfverfahren und -einrichtungen

Dieses Dokument gilt für Wasserzähler, die für den Einsatz in privaten und gewerblichen Bereichen und in Bereichen der Leichtindustrie und Industrie bestimmt sind. Es legt, ungeachtet der Technologie, die Prüfparameter und Prüfverfahren für die in #EN 14154-1:2005+A2:2011$ festgelegten Wasserzähler fest, die zur Messung des tatsächlichen Volumens von sauberem, kaltem Trinkwasser oder erwärmtem Wasser, das durch eine voll gefüllte, geschlossene Leitung fließt, eingesetzt werden. Diese Zähler müssen mit Einrichtungen versehen sein, die das summierte Volumen anzeigen.
Bei Wasserzählern mit einem Wert von Q3 > 160 m3/h dürfen zur Berücksichtigung von begrenzten Möglich-keiten in vorhandenen Prüflaboratorien im Prüfplan Veränderungen der Referenzbedingungen vorgesehen werden, insbesondere bei der Beständigkeitsprüfung und der Leistungsprüfung unter Einflussgrößen.
Bei der Kennzeichnung der auf diese Weise geprüften Zähler muss eindeutig darauf hingewiesen werden, dass sie dem vorliegenden Dokument nur teilweise entsprechen. Darüber hinaus ist der Zählerhersteller verpflichtet, diese Kennzeichnung mit einer umfassenden Beschreibung zu ergänzen, in der genau beschrieben wird, welche begrenzten Möglichkeiten im Prüflabor zu dieser Abweichung geführt haben.

Compteurs d'eau - Partie 3 : Méthodes et équipement d'essai

Le présent document s’applique aux compteurs d’eau destinés à une utilisation résidentielle, commerciale, industrielle légère et industrielle, et spécifie les paramètres et les méthodes d’essai pour les compteurs d’eau, indépendamment des technologies de conception, comme spécifié dans "EN 14154-1:2005+A2", utilisés pour mesurer le volume réel d’eau potable froide ou d’eau chaude s'écoulant dans une conduite fermée et à pleine charge. Ces compteurs d’eau doivent comprendre des dispositifs indiquant le volume intégré.
Dans le cas de compteurs d’eau ayant une valeur de Q3 > 160 m3/h, le programme d'essai peut prévoir une modification des conditions de référence pour satisfaire aux limitations du laboratoire d’essais individuel, en cas d’essais spécifiques liés à l’endurance ou à la performance sous des grandeurs d’influence.
Les compteurs ainsi soumis à l’essai doivent être marqués de manière à indiquer sans ambiguïté la conformité partielle au présent document. Pour compléter ce marquage, le fabricant du compteur est, en outre, obligé de déclarer explicitement la ou les non-conformité(s) spécifique(s) due(s) aux limitations du laboratoire d’essais.

Vodomeri - 3. del: Preskusne metode in oprema

Ta dokument velja za vodomere, namenjene stanovanjski, gospodarski, lahki industrijski in industrijski uporabi, ter določa preskusne parametre in preskusne metode za vodomere, ne glede na tehnologije načrtovanja, kot so opredeljene v EN 14154-1:2005+A2, uporabljene za merjenje dejanskega volumna čiste hladne pitne vode ali segrete vode, ki teče skozi popolnoma poln, zaprt vod. Ti vodomeri vsebujejo naprave, ki navajajo celoten volumen.
Kadar imajo vodomeri vrednost Q3 > 160 m3/h, se v program preskušanja lahko vključijo spremembe referenčnih pogojev za doseganje posameznih omejitev preskusnega laboratorija, kadar se preskuša vzdržljivost ali delovanje pri vplivnih veličinah.
Tako preskušeni vodomeri morajo biti označeni tako, da se nedvoumno navede delna skladnost s tem dokumentom. Za boljše označevanje je proizvajalec vodomera dolžan popolnoma razkriti konkretno neskladnost zaradi omejitev preskusnega laboratorija.

General Information

Status
Withdrawn
Publication Date
05-Apr-2011
Withdrawal Date
03-Jun-2014
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
04-Jun-2014
Completion Date
04-Jun-2014

Relations

Effective Date
19-Jan-2023
Effective Date
08-Jun-2022
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Standard

EN 14154-3:2005+A2:2011

English language
86 pages
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

ICC Evaluation Service

Nonprofit organization that performs technical evaluations of building products.

ANAB United States Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

BBA (British Board of Agrément)

UK construction product certification.

UKAS United Kingdom Verified

Sponsored listings

Frequently Asked Questions

EN 14154-3:2005+A2:2011 is a standard published by the European Committee for Standardization (CEN). Its full title is "Water meters - Part 3: Test methods and equipment". This standard covers: This document applies to water meters intended for residential, commercial, light industrial and industrial use, and specifies the test parameters and the test methods for water meters, irrespective of the design technologies, as specified in EN 14154-1:2005+A2, used to meter the actual volume of clean cold potable water or heated water, flowing through a fully charged, closed conduit. These water meters shall incorporate devices, which indicate the integrated volume. In the case where water meters having a value of Q3 > 160 m3/h, the test schedule may make provisions for modification of the Reference Conditions, to meet individual test laboratory limitations, when testing specifically for endurance or for performance under Influence Quantities. Meters thus tested shall be marked so as to unambiguously indicate part compliance with this document. To augment this marking the meter manufacturer shall, in addition, be obliged to fully disclose the specific non compliance(s) due to the test laboratory limitations.

This document applies to water meters intended for residential, commercial, light industrial and industrial use, and specifies the test parameters and the test methods for water meters, irrespective of the design technologies, as specified in EN 14154-1:2005+A2, used to meter the actual volume of clean cold potable water or heated water, flowing through a fully charged, closed conduit. These water meters shall incorporate devices, which indicate the integrated volume. In the case where water meters having a value of Q3 > 160 m3/h, the test schedule may make provisions for modification of the Reference Conditions, to meet individual test laboratory limitations, when testing specifically for endurance or for performance under Influence Quantities. Meters thus tested shall be marked so as to unambiguously indicate part compliance with this document. To augment this marking the meter manufacturer shall, in addition, be obliged to fully disclose the specific non compliance(s) due to the test laboratory limitations.

EN 14154-3:2005+A2:2011 is classified under the following ICS (International Classification for Standards) categories: 91.140.60 - Water supply systems. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 14154-3:2005+A2:2011 has the following relationships with other standards: It is inter standard links to EN 14154-3:2005+A1:2007, EN ISO 4064-2:2014, EN 12365-1:2003, EN 13014:2000, EN 14154-2:2005+A2:2011, EN 14154-1:2005+A2:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 14154-3:2005+A2:2011 is associated with the following European legislation: EU Directives/Regulations: 2004/22/EC; Standardization Mandates: M/347, M/374. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 14154-3:2005+A2:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Vodomeri - 3. del: Preskusne metode in opremaWasserzähler - Teil 3: Prüfverfahren und -einrichtungenCompteurs d'eau - Partie 3: Méthodes et équipement d'essaiWater meters - Part 3: Test methods and equipment91.140.60Sistemi za oskrbo z vodoWater supply systemsICS:Ta slovenski standard je istoveten z:EN 14154-3:2005+A2:2011SIST EN 14154-3:2005+A2:2011en,de01-julij-2011SIST EN 14154-3:2005+A2:2011SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14154-3:2005+A2
April 2011 ICS 91.140.60 Supersedes EN 14154-3:2005+A1:2007English Version
Water meters - Part 3: Test methods and equipment
Compteurs d'eau - Partie 3: Méthodes et équipement d'essai
Wasserzähler - Teil 3: Prüfverfahren und -einrichtungen This European Standard was approved by CEN on 26 July 2004 and includes Amendment 1 approved by CEN on 6 March 2007 and Amendment 2 approved by CEN on 22 February 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14154-3:2005+A2:2011: ESIST EN 14154-3:2005+A2:2011

units$ . 135.5Absence of flow test . 145.5.1Object of test . 145.5.2Preparation . 145.5.3Test procedure . 145.5.4Acceptance criteria . 145.6Water temperature test (within ROC) . 145.6.1Object of test . 145.6.2Preparation . 145.6.3Test procedure . 145.6.4Acceptance criteria . 155.7Overload water temperature test . 155.7.1Object of test . 155.7.2Preparation . 155.7.3Test procedure . 155.7.4Acceptance criteria . 155.8Water pressure test . 155.8.1Object of test . 155.8.2Preparation . 165.8.3Test procedure . 165.8.4Acceptance criteria . 165.9Verification of flow profile sensitivity classes . 165.9.1Object of test . 165.9.2Preparation . 16SIST EN 14154-3:2005+A2:2011

Irregularity in water velocity field . 48A.1Irregularity in water velocity field . 48A.2Flow disturbers . 48Annex B (informative)
Examples of methods and components used for testing Concentric Water Meters . 59Annex C (normative)
Equipment and method used to determine meter error . 63C.1Principle . 63C.2Description of the test rig . 63SIST EN 14154-3:2005+A2:2011

Equipment and methods for pressure loss test . 68D.1Principle . 68D.2Pressure loss test equipment . 68D.2.1General . 68D.2.2Measuring section . 68D.3Test procedure . 73D.3.1Determination of pressure loss attributable to pipe lengths for water meters (measurement 1)73D.3.2Measurement and calculation of the actual ∆∆∆∆P of a water meter (measurement 2) . 74Annex E (informative)
Characteristics of reference devices . 75E.1General . 75E.2Types of reference devices . 75E.2.1Calibration using volumetric vessels . 75E.2.2Calibration using reference meters (master meters) . 76E.2.3Calibration using calibrated tubes . 77E.2.4Calibration by weighing method . 78E.2.5Other calibration methods . 78Annex ZA (informative)
!Relationship between this European Standard and the Essential Requirements of EU Directive 22/2004/EC on Measuring Instruments" . 79Bibliography . 86 SIST EN 14154-3:2005+A2:2011

For meters T ≥ 70: (50 ± 5) °C Working (water) pressure: 200 kPa (2,0 bar) Ambient temperature range: 15 °C to 25 °C* Ambient relative humidity range: 45 % to 75 %* Ambient atmospheric pressure range: 86 kPa to 106 kPa (0,86 bar to 1,06 bar) Power supply voltage (mains a.c.): Nominal voltage (Unom) ± 5 % Power supply frequency: Nominal frequency (fnom) ± 2 % Power supply voltage (battery): A voltage U in the range; Umin ≤ U ≤ Umax During each test, the temperature and relative humidity shall not vary by more than 5 °C or 10 % respectively within the reference range. * Here the ambient temperature and/or ambient relative humidity exceed the above-mentioned ranges, the effect on the error (of indication) shall be taken in account. 4 Administrative and external examination for approval programme The meter and its technical documentation shall be examined before entering the rest of the test program. The administrative examination shall demonstrate that the water meter fulfils the respective requirements of Clause 4 of #EN 14154-1:2005+A2:2011$, which can be verified by administrative work and shall show that the meter is manufactured in conformity with it. SIST EN 14154-3:2005+A2:2011

Where the initial error curve is close to the maximum permissible error at a point other than at Q1, Q2 or Q3, if this error can be shown to be typical of the meter type, the approving authority may choose to define an alternative flowrate for initial verification in the pattern approval certificate. b) Test the water meter without its supplementary devices (if any) attached; c) during a test hold all other influence factors at reference conditions; d) measure the errors (of indication) at other flowrates if required, depending on the shape of the error curve; e) calculate the relative error (of indication) for each flowrate. 5.3.4 Acceptance criteria a) The errors observed for each of the seven flowrates shall not exceed the maximum permissible errors. If the error observed on one or more meters is greater than the maximum permissible error at one flowrate only, the test at that flowrate shall be repeated. The test shall be declared satisfactory if two out of the three results lie within the maximum permissible error and the arithmetic mean of the results for the three tests at that flowrate is less than or equal to the maximum permissible error; b) if all the errors (of indication) of the water meter have the same sign, at least one of these errors shall not exceed one half of the maximum permissible error. In all cases this requirement shall be applied equitably with respect to the water supplier and the consumer. SIST EN 14154-3:2005+A2:2011

EN 14154-2:2005+A2:2010, 5.1.3.1 – are not permitted. 5.4.5.3 Test procedure 2 cartridge meters or exchangeable metrological units to be tested in 5 connection interfaces of every compatible interface type, resulting in 10 accuracy curves for each type of compatible interface. Test flow rates according to the definition in 5.3.3 of this European Standard. 5.4.5.4 Acceptance criteria All accuracy curves shall be positioned within MPE at all times. SIST EN 14154-3:2005+A2:2011
...