SIST EN 14154-3:2005+A2:2011
(Main)Water meters - Part 3: Test methods and equipment
Water meters - Part 3: Test methods and equipment
This document applies to water meters intended for residential, commercial, light industrial and industrial use, and specifies the test parameters and the test methods for water meters, irrespective of the design technologies, as specified in EN 14154-1:2005+A2, used to meter the actual volume of clean cold potable water or heated water, flowing through a fully charged, closed conduit. These water meters shall incorporate devices, which indicate the integrated volume.
In the case where water meters having a value of Q3 > 160 m3/h, the test schedule may make provisions for modification of the Reference Conditions, to meet individual test laboratory limitations, when testing specifically for endurance or for performance under Influence Quantities.
Meters thus tested shall be marked so as to unambiguously indicate part compliance with this document. To augment this marking the meter manufacturer shall, in addition, be obliged to fully disclose the specific non compliance(s) due to the test laboratory limitations.
Wasserzähler - Teil 3: Prüfverfahren und -einrichtungen
Dieses Dokument gilt für Wasserzähler, die für den Einsatz in privaten und gewerblichen Bereichen und in Bereichen der Leichtindustrie und Industrie bestimmt sind. Es legt, ungeachtet der Technologie, die Prüfparameter und Prüfverfahren für die in #EN 14154-1:2005+A2:2011$ festgelegten Wasserzähler fest, die zur Messung des tatsächlichen Volumens von sauberem, kaltem Trinkwasser oder erwärmtem Wasser, das durch eine voll gefüllte, geschlossene Leitung fließt, eingesetzt werden. Diese Zähler müssen mit Einrichtungen versehen sein, die das summierte Volumen anzeigen.
Bei Wasserzählern mit einem Wert von Q3 > 160 m3/h dürfen zur Berücksichtigung von begrenzten Möglich-keiten in vorhandenen Prüflaboratorien im Prüfplan Veränderungen der Referenzbedingungen vorgesehen werden, insbesondere bei der Beständigkeitsprüfung und der Leistungsprüfung unter Einflussgrößen.
Bei der Kennzeichnung der auf diese Weise geprüften Zähler muss eindeutig darauf hingewiesen werden, dass sie dem vorliegenden Dokument nur teilweise entsprechen. Darüber hinaus ist der Zählerhersteller verpflichtet, diese Kennzeichnung mit einer umfassenden Beschreibung zu ergänzen, in der genau beschrieben wird, welche begrenzten Möglichkeiten im Prüflabor zu dieser Abweichung geführt haben.
Compteurs d'eau - Partie 3: Méthodes et équipement d'essai
Le présent document s’applique aux compteurs d’eau destinés à une utilisation résidentielle, commerciale, industrielle légère et industrielle, et spécifie les paramètres et les méthodes d’essai pour les compteurs d’eau, indépendamment des technologies de conception, comme spécifié dans !l’EN 14154-1:2005+A1:2007", utilisés pour mesurer le volume réel d’eau potable froide ou d’eau chaude s'écoulant dans une conduite fermée et à pleine charge. Ces compteurs d’eau doivent comprendre des dispositifs indiquant le volume intégré.
Dans le cas de compteurs d’eau ayant une valeur de Q3 > 160 m3/h, le programme d'essai peut prévoir une modification des conditions de référence pour satisfaire aux limitations du laboratoire d’essais individuel, en cas d’essais spécifiques liés à l’endurance ou à la performance sous des grandeurs d’influence.
Les compteurs ainsi soumis à l’essai doivent être marqués de manière à indiquer sans ambiguïté la conformité partielle au présent document. Pour compléter ce marquage, le fabricant du compteur est, en outre, obligé de déclarer explicitement la ou les non-conformité(s) spécifique(s) due(s) aux limitations du laboratoire d’essais.
Vodomeri - 3. del: Preskusne metode in oprema
Ta dokument velja za vodomere, namenjene stanovanjski, gospodarski, lahki industrijski in industrijski uporabi, ter določa preskusne parametre in preskusne metode za vodomere, ne glede na tehnologije načrtovanja, kot so opredeljene v EN 14154-1:2005+A2, uporabljene za merjenje dejanskega volumna čiste hladne pitne vode ali segrete vode, ki teče skozi popolnoma poln, zaprt vod. Ti vodomeri vsebujejo naprave, ki navajajo celoten volumen.
Kadar imajo vodomeri vrednost Q3 > 160 m3/h, se v program preskušanja lahko vključijo spremembe referenčnih pogojev za doseganje posameznih omejitev preskusnega laboratorija, kadar se preskuša vzdržljivost ali delovanje pri vplivnih veličinah.
Tako preskušeni vodomeri morajo biti označeni tako, da se nedvoumno navede delna skladnost s tem dokumentom. Za boljše označevanje je proizvajalec vodomera dolžan popolnoma razkriti konkretno neskladnost zaradi omejitev preskusnega laboratorija.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Vodomeri - 3. del: Preskusne metode in opremaWasserzähler - Teil 3: Prüfverfahren und -einrichtungenCompteurs d'eau - Partie 3: Méthodes et équipement d'essaiWater meters - Part 3: Test methods and equipment91.140.60Sistemi za oskrbo z vodoWater supply systemsICS:Ta slovenski standard je istoveten z:EN 14154-3:2005+A2:2011SIST EN 14154-3:2005+A2:2011en,de01-julij-2011SIST EN 14154-3:2005+A2:2011SLOVENSKI
STANDARD
SIST EN 14154-3:2005+A2:2011
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14154-3:2005+A2
April 2011 ICS 91.140.60 Supersedes EN 14154-3:2005+A1:2007English Version
Water meters - Part 3: Test methods and equipment
Compteurs d'eau - Partie 3: Méthodes et équipement d'essai
Wasserzähler - Teil 3: Prüfverfahren und -einrichtungen This European Standard was approved by CEN on 26 July 2004 and includes Amendment 1 approved by CEN on 6 March 2007 and Amendment 2 approved by CEN on 22 February 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14154-3:2005+A2:2011: ESIST EN 14154-3:2005+A2:2011
EN 14154-3:2005+A2:2011 (E) 2 Contents Page Foreword .51Scope .62Normative references .63Reference conditions .74Administrative and external examination for approval programme .75Performance tests for approval programme .85.1General requirements for the test installation .85.1.1Location .85.1.2Test water .95.1.3Calibrated reference device .95.1.4Freedom from spurious influences.95.1.5Group testing of meters . 105.2Static pressure test. 105.2.1Object of test . 105.2.2Preparation . 105.2.3Test procedure . 105.2.4Acceptance criteria . 115.3Determination of intrinsic errors (of indication) . 115.3.1Object of test . 115.3.2Preparation . 115.3.3Test procedure . 125.3.4Acceptance criteria . 125.4Error (of indication) tests . 135.4.1Object of test . 135.4.2Preparation . 135.4.3Test Procedure . 135.4.4Acceptance criteria . 135.4.5#Interchange test on all types of cartridge and meters with exchangeable metrological
units$ . 135.5Absence of flow test . 145.5.1Object of test . 145.5.2Preparation . 145.5.3Test procedure . 145.5.4Acceptance criteria . 145.6Water temperature test (within ROC) . 145.6.1Object of test . 145.6.2Preparation . 145.6.3Test procedure . 145.6.4Acceptance criteria . 155.7Overload water temperature test . 155.7.1Object of test . 155.7.2Preparation . 155.7.3Test procedure . 155.7.4Acceptance criteria . 155.8Water pressure test . 155.8.1Object of test . 155.8.2Preparation . 165.8.3Test procedure . 165.8.4Acceptance criteria . 165.9Verification of flow profile sensitivity classes . 165.9.1Object of test . 165.9.2Preparation . 16SIST EN 14154-3:2005+A2:2011
EN 14154-3:2005+A2:2011 (E) 3 5.9.3Test procedure . 165.9.4Acceptance criteria . 175.10Tests on ancillary devices of a water meter . 195.10.1Object of test . 195.10.2Preparation . 195.10.3Procedure . 195.10.4Acceptance criteria . 195.11Pressure loss test . 195.11.1Object of test . 195.11.2Preparation . 195.11.3Test procedure . 205.11.4Acceptance criteria . 205.12Reverse flow test . 205.12.1Meters designed to measure reverse flows . 205.12.2Meters not designed to measure reverse flows . 205.13Endurance tests . 215.13.1Continuous flow test . 215.13.2Discontinuous flow test . 246Performance tests related to influence quantities . 276.1General requirements . 276.1.1Environmental classification . 276.1.2Electromagnetic environments . 276.1.3Reference conditions . 276.1.4Test volumes for measuring error (of indication) of a water meter . 286.1.5Influence of the water temperature . 286.1.6Requirements for environmental tests . 286.1.7Equipment under test (EUT) . 286.2Climatic and mechanical environment . 306.2.1Dry heat (non-condensing) . 306.2.2Cold . 316.2.3Damp heat, cyclic (condensing) . 326.2.4Vibration (random) . 346.2.5Mechanical shock . 356.3Electromagnetic environment . 366.3.1Electrostatic discharge . 366.3.2Radiated radio frequency/Electromagnetic fields . 376.4Power supply . 396.4.1A.C. power voltage variation . 396.4.2A.C. voltage dips and short interruptions . 406.4.3Surge immunity . 426.4.4Electrical fast transients/Burst . 436.4.5D.C. power voltage variation . 446.5Static magnetic field . 466.5.1Object of test . 466.5.2Preparation . 466.5.3Test procedure . 466.5.4Acceptance criteria . 466.6Interruption in battery supply . 476.6.1Object of test . 476.6.2Test procedure . 476.6.3Acceptance criteria . 47Annex A (normative)
Irregularity in water velocity field . 48A.1Irregularity in water velocity field . 48A.2Flow disturbers . 48Annex B (informative)
Examples of methods and components used for testing Concentric Water Meters . 59Annex C (normative)
Equipment and method used to determine meter error . 63C.1Principle . 63C.2Description of the test rig . 63SIST EN 14154-3:2005+A2:2011
EN 14154-3:2005+A2:2011 (E) 4 C.3Pipe-work . 63C.3.1Description . 63C.3.2Test section . 64C.3.3Precautions to be taken during tests. 64C.3.4Special arrangements for the installation of meters . 64C.3.5Cyclic distortion of the meter . 66C.3.6Major factors affecting the measurement of errors of indication . 67Annex D (informative)
Equipment and methods for pressure loss test . 68D.1Principle . 68D.2Pressure loss test equipment . 68D.2.1General . 68D.2.2Measuring section . 68D.3Test procedure . 73D.3.1Determination of pressure loss attributable to pipe lengths for water meters (measurement 1)73D.3.2Measurement and calculation of the actual ∆∆∆∆P of a water meter (measurement 2) . 74Annex E (informative)
Characteristics of reference devices . 75E.1General . 75E.2Types of reference devices . 75E.2.1Calibration using volumetric vessels . 75E.2.2Calibration using reference meters (master meters) . 76E.2.3Calibration using calibrated tubes . 77E.2.4Calibration by weighing method . 78E.2.5Other calibration methods . 78Annex ZA (informative)
!Relationship between this European Standard and the Essential Requirements of EU Directive 22/2004/EC on Measuring Instruments" . 79Bibliography . 86 SIST EN 14154-3:2005+A2:2011
EN 14154-3:2005+A2:2011 (E) 5 Foreword This document (EN 14154-3:2005+A2:2011) has been prepared by Technical Committee CEN/TC 92 “Water meters”, the secretariat of which is held by SNV. This document shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2011 and conflicting national standards shall be withdrawn at the latest by October 2011. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document includes Amendment 1, approved by CEN on 2007-03-06 and Amendment 2, approved by CEN on 2011-02-22. This document supersedes #EN 14154-3:2005+A1:2007$. The start and finish of text introduced or altered by amendment is indicated in the text by tags ! " and # $. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. The standard consists of 3 parts. The other parts are: Part 1: General Requirements Part 2: Installation and conditions of use In developing a new Standard, CEN/TC 92 aimed to harmonise it with existing standards and recommendations for water meters, to accommodate new technologies and anticipating the requirements of the Directive 22/2004 EC on Measuring Instruments. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
SIST EN 14154-3:2005+A2:2011
EN 14154-3:2005+A2:2011 (E) 6 1 Scope This document applies to water meters intended for residential, commercial, light industrial and industrial use, and specifies the test parameters and the test methods for water meters, irrespective of the design technologies, as specified in #EN 14154-1:2005+A2$, used to meter the actual volume of clean cold potable water or heated water, flowing through a fully charged, closed conduit. These water meters shall incorporate devices, which indicate the integrated volume. In the case where water meters having a value of Q3 > 160 m3/h, the test schedule may make provisions for modification of the Reference Conditions, to meet individual test laboratory limitations, when testing specifically for endurance or for performance under Influence Quantities. Meters thus tested shall be marked so as to unambiguously indicate part compliance with this document. To augment this marking the meter manufacturer shall, in addition, be obliged to fully disclose the specific non compliance(s) due to the test laboratory limitations. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. #EN 14154-1:2005+A2:2011$, Water meters — Part 1: General requirements #EN 14154-2:2005+A2:2011$, Water meters — Part 2: Installation and conditions of use EN 60068-1:1994, Environmental testing — Part 1: General and guidance EN 60068-2-1:1993, Environmental testing — Part 2: Tests, Test A: Cold EN 60068-2-2:1993, Environmental testing — Part 2: Tests, Test B: Dry heat EN 60068-2-30:1999, Environmental testing — Part 2: Tests — Test Db and guidance: Damp heat, cyclic ((12 + 12) h cycle) EN 60068-2-31:1993, Environmental testing — Part 2: Tests — Test Ec: Drop and topple, primarily for equipment-type specimens EN 60068-2-47:1999 Environmental testing — Part 2-47: Test methods — Mounting of components, equipment and other articles for vibration, impact and similar dynamic tests EN 60068-2-64:1994, Environmental testing — Part 2: Test methods — Test Fh: Vibration, broad-band random (digital control) and guidance EN 60068-3-1:1999, Environmental testing — Part 3: Background information, Section 1: Cold and dry heat tests EN 61000-4-2:1995, Electromagnetic compatibility (EMC) — Part 4-2: Testing and measurement techniques — Electrostatic discharge immunity test EN 61000-4-3:1996, Electromagnetic compatibility (EMC) — Part 4-3: Testing and measurement techniques — Radiated, radio-frequency, electromagnetic field immunity test EN 61000-4-4:1995, Electromagnetic compatibility (EMC) — Part 4-4: Testing and measurement techniques — Electrical fast transient/burst immunity test EN 61000-4-5:1995, Electromagnetic compatibility (EMC) — Part 4-5: Testing and measurement techniques — Surge immunity test SIST EN 14154-3:2005+A2:2011
EN 14154-3:2005+A2:2011 (E) 7 EN 61000-4-11:1994, Electromagnetic compatibility (EMC) — Part 4-11: Testing and measurement techniques — Voltage dips, short interruptions and voltage variations immunity tests IEC 60068-3-4:2001, Environmental testing — Part 3-4: Supporting documentation and guidance — Damp heat tests ISO 4185, Measurement of fluid flow in closed conduits — Weighing method OIML D4, Installation and Storage Conditions for Cold Water Meters OIML D7, The Evaluation of Flow Standards and Facilities Used for Testing Water Meters OIML P7, Planning of Metrology and Testing Laboratories 3 Reference conditions All applicable influence quantities, except for the influence quantity being tested, shall be held at the following values during pattern approval tests on a water meter: Flowrate: 0,7 × (Q2 + Q3) ± 0,03 × (Q2 + Q3) Working (water) temperature: For meters T30 and T50: (20 ± 5) °C;
For meters T ≥ 70: (50 ± 5) °C Working (water) pressure: 200 kPa (2,0 bar) Ambient temperature range: 15 °C to 25 °C* Ambient relative humidity range: 45 % to 75 %* Ambient atmospheric pressure range: 86 kPa to 106 kPa (0,86 bar to 1,06 bar) Power supply voltage (mains a.c.): Nominal voltage (Unom) ± 5 % Power supply frequency: Nominal frequency (fnom) ± 2 % Power supply voltage (battery): A voltage U in the range; Umin ≤ U ≤ Umax During each test, the temperature and relative humidity shall not vary by more than 5 °C or 10 % respectively within the reference range. * Here the ambient temperature and/or ambient relative humidity exceed the above-mentioned ranges, the effect on the error (of indication) shall be taken in account. 4 Administrative and external examination for approval programme The meter and its technical documentation shall be examined before entering the rest of the test program. The administrative examination shall demonstrate that the water meter fulfils the respective requirements of Clause 4 of #EN 14154-1:2005+A2:2011$, which can be verified by administrative work and shall show that the meter is manufactured in conformity with it. SIST EN 14154-3:2005+A2:2011
EN 14154-3:2005+A2:2011 (E) 8 The followin
...