EN 62109-2:2011
(Main)Safety of power converters for use in photovoltaic power systems - Part 2: Particular requirements for inverters
Safety of power converters for use in photovoltaic power systems - Part 2: Particular requirements for inverters
IEC 62109-2:2011 covers the particular safety requirements relevant to d.c. to a.c. inverter products as well as products that have or perform inverter functions in addition to other functions, where the inverter is intended for use in photovoltaic power systems. Inverters covered by this standard may be grid-interactive, stand-alone, or multiple mode inverters, may be supplied by single or multiple photovoltaic modules grouped in various array configurations, and may be intended for use in conjunction with batteries or other forms of energy storage. This standard must be used jointly with IEC 62109-1.
Sicherheit von Leistungsumrichtern zur Anwendung in photovoltaischen Energiesystemen - Teil 2: Besondere Anforderungen an Wechselrichter
Sécurité des convertisseurs de puissance utilisés dans les systèmes photovoltaïques - Partie 2: Exigences particulières pour les onduleurs
La CEI 62109-2:2011 couvre les exigences de sécurité particulières concernant les onduleurs transformant un courant continu en courant alternatif, ainsi que les produits possédant ou exécutant des fonctions d'onduleur en plus d'autres fonctions, lorsque l'onduleur est destiné à être utilisé dans des systèmes photovoltaïques. Les onduleurs couverts par la présente norme peuvent être des onduleurs couplés au réseau, autonomes ou multimodes, ils peuvent être alimentés par des modules photovoltaïques simples ou multiples regroupés en diverses configurations de générateurs et ils peuvent être destinés à être utilisés conjointement avec des batteries ou avec d'autres formes de stockage d'énergie. Cette norme doit être lue conjointement avec la CEI 62109-1.
Varnost močnostnih pretvornikov, ki se uporabljajo v fotonapetostnih sistemih - 2. del: Posebne zahteve za razsmernike (IEC 62109-2:2011)
Ta 2. del IEC 62109 zajema posebne varnostne zahteve, pomembne za razsmernike med enosmernim in izmeničnim tokom, ter proizvode, ki imajo ali izvajajo poleg drugih funkcij tudi razsmerniško funkcijo, pri katerih je razsmernik namenjen uporabi v fotonapetostnih sistemih. Razsmerniki, ki jih zajema ta standard, so lahko omrežno interaktivni, samostojni ali večnačinovni razsmerniki, lahko so dobavljeni v enojnih ali večkratnih fotonapetostnih modulih, združenih v različne konfiguracije nizov, in se lahko uporabljajo v povezavi z baterijami ali drugimi oblikami shranjevanja energije. Razsmerniki z več funkcijami ali načini se presojajo glede na vse ustrezne zahteve za vsako funkcijo oziroma vsak način. Ta standard ne obravnava zahtev za omrežno povezovanje pri omrežno interaktivnih razsmernikih.
General Information
Relations
Overview
EN 62109-2:2011 (identical to IEC 62109-2:2011) defines the particular safety requirements for d.c. to a.c. inverters intended for use in photovoltaic (PV) power systems. It is a Part 2 document that supplements and modifies the general requirements in EN/IEC 62109-1:2010. The standard applies to grid‑interactive, stand‑alone and multi‑mode inverters, including devices that combine inverter functions with other power‑conversion roles, and covers systems with batteries or other energy storage and a variety of PV array configurations.
Key Topics
The standard focuses on safety, testing and information requirements specific to PV inverters. Major technical topics include:
- Use with Part 1: EN 62109-2 is to be used jointly with EN/IEC 62109-1; Part 2 adds or modifies clauses from Part 1.
- Testing requirements: single‑fault testing, electrical ratings tests and environmental testing (see clauses such as 4.4 and 4.7).
- Stand‑alone inverter performance: AC output voltage, frequency, waveform and load step response (clauses 4.7.4–4.7.5).
- Grid‑interactive tests: additional requirements for inverter isolation, array grounding, array insulation resistance detection and residual current detection (clause 4.8).
- Residual current and RCDs: includes specific tests such as a 30 mA touch‑current type test for isolated inverters and fire‑hazard residual current tests, plus guidance on residual current monitoring and protection by RCDs.
- Protection domains: electric shock, fire, mechanical, sonic, liquid and chemical hazards (clauses 7–12).
- Operational safety: single fault tolerance, cooling system failure tests (blanketing test), inverter backfeed onto arrays and load transfer for stand‑alone systems.
- Marking and documentation: required ratings, warning markings and installation information (clause 5), including firmware identification and setpoints for grid‑interactive inverters.
Applications
EN 62109-2 is used to ensure inverter safety across the PV industry. Typical users:
- Inverter manufacturers - to design and verify safety features, testing and documentation for product certification.
- Test laboratories and certification bodies - to perform compliance testing and type approval.
- System designers and integrators - to select inverters that meet safety and installation requirements (grid‑interactive vs stand‑alone, array grounding).
- Installers and asset owners - to understand marking, warnings and installation information required by the standard.
Keywords: EN 62109-2:2011, IEC 62109-2, photovoltaic inverters, inverter safety, PV system standards, residual current detection, array insulation resistance, RCD.
Related standards
- EN/IEC 62109-1:2010 (General requirements) - mandatory companion standard.
- Referenced harmonized standards noted in EN 62109-2 include IEC 60364-7-712, IEC 61727, IEC 61730-1 and IEC 62116 (see Annex ZA for normative cross‑references).
Frequently Asked Questions
EN 62109-2:2011 is a standard published by CLC. Its full title is "Safety of power converters for use in photovoltaic power systems - Part 2: Particular requirements for inverters". This standard covers: IEC 62109-2:2011 covers the particular safety requirements relevant to d.c. to a.c. inverter products as well as products that have or perform inverter functions in addition to other functions, where the inverter is intended for use in photovoltaic power systems. Inverters covered by this standard may be grid-interactive, stand-alone, or multiple mode inverters, may be supplied by single or multiple photovoltaic modules grouped in various array configurations, and may be intended for use in conjunction with batteries or other forms of energy storage. This standard must be used jointly with IEC 62109-1.
IEC 62109-2:2011 covers the particular safety requirements relevant to d.c. to a.c. inverter products as well as products that have or perform inverter functions in addition to other functions, where the inverter is intended for use in photovoltaic power systems. Inverters covered by this standard may be grid-interactive, stand-alone, or multiple mode inverters, may be supplied by single or multiple photovoltaic modules grouped in various array configurations, and may be intended for use in conjunction with batteries or other forms of energy storage. This standard must be used jointly with IEC 62109-1.
EN 62109-2:2011 is classified under the following ICS (International Classification for Standards) categories: 27.160 - Solar energy engineering. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 62109-2:2011 has the following relationships with other standards: It is inter standard links to prEN IEC 62109-2:2025. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 62109-2:2011 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU, 2014/53/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase EN 62109-2:2011 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-november-2011
9DUQRVWPRþQRVWQLKSUHWYRUQLNRYNLVHXSRUDEOMDMRYIRWRQDSHWRVWQLKVLVWHPLK
GHO3RVHEQH]DKWHYH]DUD]VPHUQLNH,(&
Safety of power converters for use in photovoltaic power systems - Part 2: Particular
requirements for inverters (IEC 62109-2:2011)
Sicherheit von Leistungsumrichtern zur Anwendung in photovoltaischen
Energiesystemen - Teil 2: Besondere Anforderungen an Wechselrichter (IEC 62109-
2:2011)
Sécurité des convertisseurs de puissance utilisés dans les systèmes photovoltaïques -
Partie 2: Exigences particulières pour les onduleurs (CEI 62109-2:2011)
Ta slovenski standard je istoveten z: EN 62109-2:2011
ICS:
27.160 6RQþQDHQHUJLMD Solar energy engineering
29.200 8VPHUQLNL3UHWYRUQLNL Rectifiers. Convertors.
6WDELOL]LUDQRHOHNWULþQR Stabilized power supply
QDSDMDQMH
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 62109-2
NORME EUROPÉENNE
September 2011
EUROPÄISCHE NORM
ICS 27.160
English version
Safety of power converters for use in photovoltaic power systems -
Part 2: Particular requirements for inverters
(IEC 62109-2:2011)
Sécurité des convertisseurs de puissance Sicherheit von Leistungsumrichtern zur
utilisés dans les systèmes Anwendung in photovoltaischen
photovoltaïques - Energiesystemen -
Partie 2: Exigences particulières pour les Teil 2: Besondere Anforderungen an
onduleurs Wechselrichter
(CEI 62109-2:2011) (IEC 62109-2:2011)
This European Standard was approved by CENELEC on 2011-07-28. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 62109-2:2011 E
Foreword
The text of document 82/636/FDIS, future edition 1 of IEC 62109-2, prepared by IEC TC 82, "Solar
photovoltaic energy systems", was submitted to the IEC-CENELEC parallel vote and was approved by
CENELEC as EN 62109-2 on 2011-07-28.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2012-04-28
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2014-07-28
with the EN have to be withdrawn
The requirements in this Part 2 are to be used with the requirements in Part 1, and supplement or modify
clauses in Part 1. When a particular clause or subclause of Part 1 is not mentioned in this Part 2, that
clause of Part 1 applies. When this Part 2 contains clauses that add to, modify, or replace clauses in
Part 1, the relevant text of Part 1 is to be applied with the required changes.
Subclauses, figures and tables additional to those in Part 1 are numbered in continuation of the sequence
existing in Part 1.
All references to “Part 1” in this Part 2 shall be taken as dated references to EN 62109-1:2010.
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 62109-2:2011 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60364-7-712 NOTE Harmonized as HD 60364-7-712.
IEC 61008-1 NOTE Harmonized as EN 61008-1.
IEC 61727 NOTE Harmonized as EN 61727.
IEC 61730-1 NOTE Harmonized as EN 61730-1.
IEC 62116 NOTE Harmonized as EN 62116.
__________
- 3 - EN 62109-2:2011
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Addition to EN 62109-1:2010:
Publication Year Title EN/HD Year
IEC 62109-1 2010 Safety of power converters for use in EN 62109-1 2010
photovoltaic power systems -
Part 1: General requirements
IEC 62109-2 ®
Edition 1.0 2011-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Safety of power converters for use in photovoltaic power systems –
Part 2: Particular requirements for inverters
Sécurité des convertisseurs de puissance utilisés dans les systèmes
photovoltaïques –
Partie 2: Exigences particulières pour les onduleurs
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX V
ICS 27.160 ISBN 978-2-88912-491-6
– 2 – 62109-2 IEC:2011
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope and object . 7
1.1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 8
4 General testing requirements. 9
4.4 Testing in single fault condition . 9
4.4.4 Single fault conditions to be applied . 9
4.4.4.15 Fault-tolerance of protection for grid-interactive inverters . 9
4.4.4.16 Stand-alone inverters – Load transfer test . 12
4.4.4.17 Cooling system failure – Blanketing test . 12
4.7 Electrical ratings tests . 12
4.7.3 Measurement requirements for AC output ports for stand-alone
inverters . 13
4.7.4 Stand-alone Inverter AC output voltage and frequency . 13
4.7.4.1 General . 13
4.7.4.2 Steady state output voltage at nominal DC input . 13
4.7.4.3 Steady state output voltage across the DC input range . 13
4.7.4.4 Load step response of the output voltage at nominal DC
input . 13
4.7.4.5 Steady state output frequency . 13
4.7.5 Stand-alone inverter output voltage waveform . 14
4.7.5.1 General . 14
4.7.5.2 Sinusoidal output voltage waveform requirements . 14
4.7.5.3 Non-sinusoidal output waveform requirements . 14
4.7.5.4 Information requirements for non-sinusoidal waveforms . 14
4.7.5.5 Output voltage waveform requirements for inverters for
dedicated loads . 15
4.8 Additional tests for grid-interactive inverters . 15
4.8.1 General requirements regarding inverter isolation and array
grounding . 15
4.8.2 Array insulation resistance detection for inverters for ungrounded and
functionally grounded arrays . 17
4.8.2.1 Array insulation resistance detection for inverters for
ungrounded arrays . 17
4.8.2.2 Array insulation resistance detection for inverters for
functionally grounded arrays . 17
4.8.3 Array residual current detection . 18
4.8.3.1 General . 18
4.8.3.2 30 mA touch current type test for isolated inverters . 19
4.8.3.3 Fire hazard residual current type test for isolated inverters . 19
4.8.3.4 Protection by application of RCD’s . 19
4.8.3.5 Protection by residual current monitoring . 19
4.8.3.6 Systems located in closed electrical operating areas . 22
5 Marking and documentation . 22
5.1 Marking . 23
62109-2 IEC:2011 – 3 –
5.1.4 Equipment ratings. 23
5.2 Warning markings . 23
5.2.2 Content for warning markings . 23
5.2.2.6 Inverters for closed electrical operating areas . 24
5.3 Documentation . 24
5.3.2 Information related to installation . 24
5.3.2.1 Ratings . 24
5.3.2.2 Grid-interactive inverter setpoints . 25
5.3.2.3 Transformers and isolation . 25
5.3.2.4 Transformers required but not provided. 25
5.3.2.5 PV modules for non-isolated inverters . 25
5.3.2.6 Non-sinusoidal output waveform information . 25
5.3.2.7 Systems located in closed electrical operating areas . 26
5.3.2.8 Stand-alone inverter output circuit bonding . 26
5.3.2.9 Protection by application of RCD’s . 26
5.3.2.10 Remote indication of faults . 26
5.3.2.11 External array insulation resistance measurement and
response . 26
5.3.2.12 Array functional grounding information . 26
5.3.2.13 Stand-alone inverters for dedicated loads . 27
5.3.2.14 Identification of firmware version(s) . 27
6 Environmental requirements and conditions. 27
7 Protection against electric shock and energy hazards . 27
7.3 Protection against electric shock . 27
7.3.10 Additional requirements for stand-alone inverters . 27
7.3.11 Functionally grounded arrays . 28
8 Protection against mechanical hazards . 28
9 Protection against fire hazards . 28
9.3 Short-circuit and overcurrent protection . 28
9.3.4 Inverter backfeed current onto the array . 28
10 Protection against sonic pressure hazards. 28
11 Protection against liquid hazards . 28
12 Protection against chemical hazards . 28
13 Physical requirements . 29
13.9 Fault indication . 29
14 Components . 29
Bibliography . 30
Figure 20 – Example system discussed in Note 2 above . 11
Figure 21 – Example test circuit for residual current detection testing . 21
Table 30 – Requirements based on inverter isolation and array grounding . 16
Table 31 – Response time limits for sudden changes in residual current . 20
Table 32 – Inverter ratings – Marking requirements . 23
Table 33 – Inverter ratings – Documentation requirements . 24
– 4 – 62109-2 IEC:2011
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
SAFETY OF POWER CONVERTERS FOR USE
IN PHOTOVOLTAIC POWER SYSTEMS –
Part 2: Particular requirements for inverters
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62109-2 has been prepared by IEC technical committee 82: Solar
photovoltaic energy systems.
The text of this standard is based on the following documents:
FDIS Report on voting
82/636/FDIS 82/648A/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
62109-2 IEC:2011 – 5 –
The requirements in this Part 2 are to be used with the requirements in Part 1, and
supplement or modify clauses in Part 1. When a particular clause or subclause of Part 1 is not
mentioned in this Part 2, that clause of Part 1 applies. When this Part 2 contains clauses that
add to, modify, or replace clauses in Part 1, the relevant text of Part 1 is to be applied with
the required changes.
Subclauses, figures and tables additional to those in Part 1 are numbered in continuation of
the sequence existing in Part 1.
All references to “Part 1” in this Part 2 shall be taken as dated references to
IEC 62109-1:2010.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 6 – 62109-2 IEC:2011
INTRODUCTION
This Part 2 of IEC 62109 gives requirements for grid-interactive and stand-alone inverters.
This equipment has potentially hazardous input sources and output circuits, internal
components, and features and functions, which demand different requirements for safety than
those given in Part 1 (IEC 62109-1:2010).
62109-2 IEC:2011 – 7 –
SAFETY OF POWER CONVERTERS FOR USE
IN PHOTOVOLTAIC POWER SYSTEMS –
Part 2: Particular requirements for inverters
1 Scope and object
This clause of Part 1 is applicable with the following exception:
1.1 Scope
Addition:
This Part 2 of IEC 62109 covers the particular safety requirements relevant to d.c. to a.c.
inverter products as well as products that have or perform inverter functions in addition to
other functions, where the inverter is intended for use in photovoltaic power systems.
Inverters covered by this standard may be grid-interactive, stand-alone, or multiple mode
inverters, may be supplied by single or multiple photovoltaic modules grouped in various
array configurations, and may be intended for use in conjunction with batteries or other forms
of energy storage.
Inverters with multiple functions or modes shall be judged against all applicable requirements
for each of those functions and modes.
NOTE Throughout this standard where terms such as “grid-interactive inverter” are used, the meaning is either a
grid-interactive inverter or a grid-interactive operating mode of a multi-mode inverter
This standard does not address grid interconnection requirements for grid-interactive
inverters.
NOTE The authors of this Part 2 did not think it would be appropriate or successful to attempt to put grid
interconnection requirements into this standard, for the following reasons:
a) Grid interconnection standards typically contain both protection and power quality requirements, dealing with
aspects such as disconnection under abnormal voltage or frequency conditions on the grid, protection against
islanding, limitation of harmonic currents and d.c. injection, power factor, etc. Many of these aspects are
power quality requirements that are beyond the scope of a product safety standard such as this.
b) At the time of writing there is inadequate consensus amongst regulators of grid-interactive inverters to lead to
acceptance of harmonized interconnect requirements. For example, IEC 61727 gives grid interconnection
requirements, but has not gained significant acceptance, and publication of EN 50438 required inclusion of
country-specific deviations for a large number of countries.
c) The recently published IEC 62116 contains test methods for islanding protection.
This standard does contain safety requirements specific to grid-interactive inverters that are similar to the safety
aspects of some existing national grid interconnection standards.
Users of this standard should be aware that in most jurisdictions allowing grid interconnection of inverters there are
national or local requirements that must be met. Examples include EN 50438, IEEE 1547, DIN VDE 0126-1-1, and
AS 4777.3
2 Normative references
This clause of Part 1 is applicable, with the following exception:
Addition
– 8 – 62109-2 IEC:2011
IEC 62109-1:2010, Safety of power converters for use in photovoltaic power systems – Part 1:
General requirements
3 Terms and definitions
This clause of Part 1 is applicable, with the following exceptions:
Additional definitions
3.100
functionally grounded array
a PV array that has one conductor intentionally connected to earth for purposes other than
safety, by means not complying with the requirements for protective bonding
NOTE 1 Such a system is not considered to be a grounded array – see 3.102.
NOTE 2 Examples of functional array grounding include grounding one conductor through an impedance, or only
temporarily grounding the array for functional or performance reasons
NOTE 3 In an inverter intended for an un-grounded array, that uses a resistive measurement network to measure
the array impedance to ground, that measurement network is not considered a form of functional grounding.
3.101
grid-interactive inverter
an inverter or inverter function intended to export power to the grid
NOTE Also commonly referred to as “grid-connected”, “grid-tied”, “utility-interactive”. Power exported may or may
not be in excess of the local load.
3.102
grounded array
a PV array that has one conductor intentionally connected to earth by means complying with
the requirements for protective bonding
NOTE 1 The connection to earth of the mains circuit in a non-isolated inverter with an otherwise ungrounded
array, does not create a grounded array. In this standard such a system is an ungrounded array because the
inverter electronics are in the fault current path from the array to the mains grounding point, and are not
considered to provide reliable grounding of the array
NOTE 2 This is not to be confused with protective earthing (equipment grounding) of the array frame
NOTE 3 In some local installation codes, grounded arrays are allowed or required to open the array connection to
earth under ground-fault conditions on the array, to interrupt the fault current, temporarily ungrounding the array
under fault conditions. This arrangement is still considered a grounded array in this standard.
3.103
indicate a fault
annunciate that a fault has occurred, in accordance with 13.9
3.104
inverter
electric energy converter that changes direct electric current to single-phase or polyphase
alternating current
3.105
inverter backfeed current
the maximum current that can be impressed onto the PV array and its wiring from the inverter,
under normal or single fault conditions
3.106
isolated inverter
an inverter with at least simple separation between the mains and PV circuits
62109-2 IEC:2011 – 9 –
NOTE 1 In an inverter with more than one external circuit, there may be isolation between some pairs of circuits
and no isolation between others. For example, an inverter with PV, battery, and mains circuits may provide
isolation between the mains circuit and the PV circuit, but no isolation between the PV and battery circuits. In this
standard, the term isolated inverter is used as defined above in general – referring to isolation between the mains
and PV circuits. If two circuits other than the mains and PV circuits are being discussed, additional wording is used
to clarify the meaning.
NOTE 2 For an inverter that does not have internal isolation between the mains and PV circuits, but is required to
be used with a dedicated isolation transformer, with no other equipment connected to the inverter side of that
isolation transformer, the combination may be treated as an isolated inverter. Other configurations require analysis
at the system level, and are beyond the scope of this standard, however the principles in this standard may be
used in the analysis.
3.107
multiple mode inverter
an inverter that operates in more than one mode, for example having grid-interactive
functionality when mains voltage is present, and stand-alone functionality when the mains is
de-energized or disconnected
3.108
non-isolated inverter
an inverter without at least simple separation between the mains and PV circuits
NOTE See the notes under 3.106 above.
3.109
stand-alone inverter
an inverter or inverter function intended to supply AC power to a load that is not connected to
the mains.
NOTE Stand-alone inverters may be designed to be paralleled with other non-mains sources (other inverters,
rotating generators, etc.). Such a system does not constitute a grid-interactive system.
4 General testing requirements
This clause of Part 1 is applicable except as follows:
NOTE In IEC 62109-1 and therefore in this Part 2, test requirements that relate only to a single type of hazard
(shock, fire, etc.) are located in the clause specific to that hazard type. Test requirements that relate to more than
one type of hazard (for example testing under fault conditions) or that provide general test conditions, are located
in this Clause 4.
4.4 Testing in single fault condition
4.4.4 Single fault conditions to be applied
Additional subclauses:
4.4.4.15 Fault-tolerance of protection for grid-interactive inverters
4.4.4.15.1 Fault-tolerance of residual current monitoring
Where protection against hazardous residual currents according to 4.8.3.5 is required, the
residual current monitoring system must be able to operate properly with a single fault
applied, or must detect the fault or loss of operability and cause the inverter to indicate a fault
in accordance with 13.9, and disconnect from, or not connect to, the mains, no later than the
next attempted re-start.
NOTE For a PV inverter, the “next attempted re-start” will occur no later than the morning following the fault
occurring. Operation during that period of less than one day is allowed because it is considered highly unlikely that
a fault in the monitoring system would happen on the same day as a person coming into contact with normally
enclosed hazardous live parts of the PV system, or on the same day as a fire-hazardous ground fault.
Compliance is checked by testing with the grid-interactive inverter connected as in reference
test conditions in Part 1. Single faults are to be applied in the inverter one at a time, for
– 10 – 62109-2 IEC:2011
example in the residual current monitoring circuit, other control circuits, or in the power
supply to such circuits.
For each fault condition, the inverter complies if one of the following occurs:
a) the inverter ceases to operate, indicates a fault in accordance with 13.9, disconnects from
the mains, and does not re-connect after any sequence of removing and reconnecting PV
power, AC power, or both,
or
b) the inverter continues to operate, passes testing in accordance with 4.8.3.5 showing that
the residual current monitoring system functions properly under the single fault condition,
and indicates a fault in accordance with 13.9,
or
c) the inverter continues to operate, regardless of loss of residual current monitoring
functionality, but does not re-connect after any sequence of removing and reconnecting
PV power, AC power, or both, and indicates a fault in accordance with 13.9.
4.4.4.15.2 Fault-tolerance of automatic disconnecting means
4.4.4.15.2.1 General
The means provided for automatic disconnection of a grid-interactive inverter from the mains
shall:
– disconnect all grounded and ungrounded current-carrying conductors from the mains, and
– be such that with a single fault applied to the disconnection means or to any other location
in the inverter, at least basic insulation or simple separation is maintained between the PV
array and the mains when the disconnecting means is intended to be in the open state.
4.4.4.15.2.2 Design of insulation or separation
The design of the basic insulation or simple separation referred to in 4.4.4.15.2.1 shall
comply with the following:
– the basic insulation or simple separation shall be based on the PV circuit working voltage,
impulse withstand voltage, and temporary over-voltage, in accordance with 7.3.7 of Part 1;
– the mains shall be assumed to be disconnected;
– the provisions of 7.3.7.1.2 g) of Part 1 may be applied if the design incorporates means to
reduce impulse voltages, and where required by 7.3.7.1.2 of Part 1, monitoring of such
means;
– in determining the clearance based on working voltage in 7.3.7 of Part 1, the values of
column 3 of Table 13 of Part 1 shall be used.
NOTE 1 These requirements are intended to protect workers who are servicing the AC mains system. In that
scenario the mains will be disconnected, and the hazard being protected against is the array voltage appearing
on the disconnected mains wiring, either phase-to-phase, or phase-to-earth. Therefore it is the PV array
parameters (working voltage, impulse withstand voltage, and temporary over-voltage) that determine the
required insulation or separation. The worker may be in a different location than any PV disconnection means
located between the array and the inverter, or may not have access, so the insulation or separation provided in
the inverter must be relied on. In a non-isolated inverter, only the required automatic disconnection means
separates the mains service worker from the PV voltage. In an isolated inverter, the isolation transformer and
other isolation components are in series with the automatic disconnection means, and separate the worker
from the PV voltage in the event of failure of the automatic disconnection means.
NOTE 2 Example for a single-phase non-isolated inverter: Assume a non-isolated inverter rated for a floating
array with a PV maximum input rating of 1 000 V d.c., and intended for use on a single-phase AC mains with
an earthed neutral. See Figure 20 below.
– Subclause 4.4.4.15.2.1 requires the design to provide basic insulation after application of a single fault, in
order to protect against shock hazard from the PV voltage for someone working on the mains circuits.
– One common method for achieving the required fault tolerant automatic disconnection means is to use 2
relays (a1 and b1 in Figure 20 below) in the ungrounded AC conductor (line), and another 2 relays (a2 and
62109-2 IEC:2011 – 11 –
b2) in the grounded conductor (neutral). The required single-fault tolerance can then be arranged by
having 2 separate relay control circuits (Control A and B) each controlling one line relay and one neutral
relay. In any single fault scenario involving one control circuit or one relay, there will still be at least one
relay in the line and one relay in the neutral that can properly open to isolate both mains circuit conductors
from the inverter and therefore from the array.
– Since the mains neutral is earthed in this example, there is single fault protection from a possible shock
hazard between the neutral and earth regardless of isolation of the mains from the inverter and the PV
array. Therefore the shock hazard the relays need to protect against is from the mains line conductor to
earth or neutral.
– The single fault scenario prevents one pair of relays from opening, but leaves the remaining un-faulted
pair of relays properly able to open and to provide the required basic insulation.
– In order for a shock to occur, current would have to flow from the mains line conductor, through the
person, to earth or neutral, and back to the line conductor through both of the remaining relay gaps in
series. Therefore the required basic insulation is provided by the total of the air gaps in the two remaining
relays.
– From Table 12 of Part 1, the impulse voltage withstand rating for a PV circuit system voltage of 1000 V dc
is 4 464 V. From Table 13 of Part 1, the required total clearance is 3,58 mm divided between the air gaps
in the two remaining relays. If identical relays are used, each relay must provide approximately 1,8 mm
clearance. The required creepage across the open relays depends on the pollution degree and material
group, is based on 1000 V d.c., and is divided between the air gaps in the two remaining relays.
– Similar analysis can be done for other system and inverter topologies.
Touch point with
Inverter
potential hazard to
earth or neutral
a1
b1
Line
Open mains
disconnect switch
1 000 V
Array
b2
Neutral
Earthed neutral is
safe to touch
a2
Control A Control B
IEC 1012/11
Figure 20 – Example system discussed in Note 2 above
4.4.4.15.2.3 Automatic checking of the disconnect means
For a non-isolated inverter, the isolation provided by the automatic disconnection means shall
be automatically checked before the inverter starts operation. After the isolation check, if the
check fails, any still-functional disconnection means shall be left in the open position, at least
basic insulation or simple separation shall be maintained between the PV input and the
mains, the inverter shall not start operation, and the inverter shall indicate a fault in
accordance with 13.9.
Compliance with 4.4.4.15.2.1 through 4.4.4.15.2.3 is checked by inspection of the PCE and
schematics, evaluation of the insulation or separation provided by components, and for non-
isolated inverters by the following test:
With the non-isolated grid-interactive inverter connected and operating as in reference test
conditions in Part 1, single faults are to be applied to the automatic disconnection means or to
other relevant parts of the inverter. The faults shall be chosen to render all or part of the
disconnection means inoperable, for example by defeating control means or by short-
circuiting one switch pole at a time. With the inverter operating, the fault is applied, and then
PV input voltage is removed or lowered below the minimum required for inverter operation, to
trigger a disconnection from the mains. The PV input voltage is then raised back up into the
operational range. After the inverter completes its isolation check, any still-functional
– 12 – 62109-2 IEC:2011
disconnection means shall be in the open position, at least basic insulation or simple
separation shall be maintained between the PV input and the mains, the inverter shall not
start operation, and the inverter shall indicate a fault in accordance with 13.9.
In all cases, the non-isolated grid-interactive inverter shall comply with the requirements for
basic insulation or simple separation between the mains and the PV input following
application of the fault.
4.4.4.16 Stand-alone inverters – Load transfer test
A stand-alone inverter with a transfer switch to transfer AC loads from the mains or other AC
bypass source to the inverter output shall continue to operate normally and shall not present a
risk of fire or shock as the result of an out-of-phase transfer.
Compliance is checked by the following test. The bypass a.c. source is to be displaced 180°
from the a.c. output of a single-phase inverter and 120° for a 3-phase supply. The transfer
switch is to be subjected to one operation of switching the load from the a.c. output of the
inverter to the bypass a.c. source. The load is to be adjusted to draw maximum rated a.c.
power.
For an inverter employing a bypass switch having a control preventing switching between two
a.c. sources out of synchronization, the test is to be conducted under the condition of a
component malfunction when such a condition could result in an out-of-phase transfer
between the two a.c. sources of supply.
4.4.4.17 Cooling system failure – Blanketing test
In addition to the applicable tests of subclause 4.4.4.8 of Part 1, inadvertent obstruction of the
airflow over an exposed external heatsink shall be one of the fault conditions considered. No
hazards according to the criteria of subclause 4.4.3 of Part 1 shall result from blanketing the
inverter in accordance with the test below.
This test is not required for inverters restricted to use only in closed electrical operating
areas.
NOTE The intent of this testing is to simulate unintentional blanketing that may occur after installation, due to lack
of user awareness of the need for proper ventilation. For example, inverters for residential systems may be
installed in spaces such as closets that originally allow proper ventilation, but later get used for storage of
household goods. In such a situation, the heatsink may have materials resting against it that block convection and
prevent heat exchange with the ambient air. Tests for blocked ventilation openings and failed fans are contained in
Part 1, but not for blanketing of a heatsink.
Compliance is checked by the following test, performed in accordance with the requirements
of subclause 4.4.2 of Part 1 along with the following.
The inverter shall be mounted in accordance with the manufacturer’s installation instructions.
If more than one position or orientation is allowed, the test shall be performed in the
orientation or position that is most likely to result in obstruction of the heatsink after
installation. The entire inverter including any external heatsink provided shall be covered in
surgical cotton with an uncompressed thickness of minimum 2 cm, covering all heatsink fins
and air channels. This surgical cotton replaces the cheesecloth required by subclause 4.4.3.2
of Part 1. The inverter shall be operated at full power. The duration of the test shall be a
minimum of 7 h except that the test may be stopped when temperatures stabilize if no
external surface of the inverter is at a temperature exceeding 90 °C.
4.7 Electrical ratings tests
Additional subclauses:
62109-2 IEC:2011 – 13 –
4.7.3 Measurement requirements for AC output ports for stand-alone inverters
Measurements of the AC output voltage and current on a stand-alone inverter shall be made
with a meter that indicates the true RMS value.
NOTE Some non-sinusoidal inverter output waveforms will not be properly measured if an average responding
meter is used.
4.7.4 Stand-alone Inverter AC output voltage and frequency
4.7.4.1 General
The AC output voltage and frequency of a stand-alone inverter, or multi-mode inverter
operating in stand-alone mode, shall comply with the requirements of 4.7.4.2 to 4.7.4.5.
4.7.4.2 Steady state output voltage at nominal DC input
The steady-state AC output voltage shall not be less than 90 % or more than 110 % of the
rated nominal voltage with the inverter supplied with its nominal value of DC input voltage.
Compliance is checked by measuring the AC output voltage with the inverter supplying no
load, and again with the inverter supplying a resistive load equal to the inverters rated
maximum continuous output power in stand-alone mode. The AC output voltage is measured
after any transient effects from the application or removal of the load have ceased.
4.7.4.3 Steady state output voltage across the DC input range
The steady-state AC output voltage shall not be less than 85 % or more than 110 % of the
rated nominal voltage with the inverter supplied with any value within the rated range of DC
input voltage.
Compliance is checked by measuring the AC output voltage under four sets of conditions: with
the inverter supplying no load and supplying a resistive load equal to the inverters rated
maximum continuous output power in stand-alone mode, both at the minimum rated DC input
voltage and at the maximum rated DC input voltage. The AC output voltage is measured after
any transient effects from the application or removal of the load have cea
...
SIST EN 62109-2:2011は、光起電力(PV)発電システムにおけるパワーコンバータの安全性を確保するための重要な標準であり、特にインバータに関する具体的要求事項を示しています。この標準は、直流(d.c.)から交流(a.c.)への変換器製品に関連する安全要求をカバーしており、他の機能も持つ製品やインバータ機能を実行する製品を含んでいます。 この標準の大きな強みは、グリッド接続型、スタンドアロン型、または複数モードのインバータのすべてを網羅している点です。これにより、さまざまな設置条件に応じた適切な安全対策が定義され、インバータが単一または複数の光起電力モジュールから供給される場合や、バッテリーや他のエネルギー貯蔵システムと組み合わせて使用されるシナリオにも対応しています。 SIST EN 62109-2:2011は、IEC 62109-1と併用する必要があり、これにより全体的な安全性と性能が保証されます。標準が設定する要求を満たすことにより、エンドユーザーは信頼性の高い電力供給を享受でき、同時にシステム全体の安全性も向上します。この標準は、光起電力インバータの設計、製造、設置だけでなく、保守点検にも重要な指針を提供しています。 全体として、SIST EN 62109-2:2011は、光起電力発電システムにおけるインバータの安全性を高めるための根幹となる基準であり、業界の発展および消費者保護にとって欠かせない存在です。
La norme EN 62109-2:2011 présente des exigences de sécurité spécifiques pour les convertisseurs de puissance utilisés dans les systèmes photovoltaïques, en particulier pour les onduleurs. Son champ d'application couvre les produits d'onduleurs de courant continu à courant alternatif, ainsi que ceux qui remplissent des fonctions d'onduleur en plus d'autres fonctions. Cette spécificité est cruciale pour garantir la sécurité et la fiabilité dans les systèmes photovoltaïques. L'un des points forts de la norme est son approche exhaustive qui inclut des exigences de sécurité tant pour les onduleurs connectés au réseau que pour les onduleurs autonomes ou multimodes. Cela permet une grande flexibilité d'utilisation dans une variété d'applications, qu'il s'agisse de configurations avec un seul module photovoltaïque ou des systèmes plus complexes avec plusieurs modules en série ou en parallèle. De plus, la norme EN 62109-2:2011 met l'accent sur la compatibilité des systèmes avec des dispositifs de stockage d'énergie, comme les batteries, ce qui renforce sa pertinence dans le contexte actuel où l'intégration des énergies renouvelables et des solutions de stockage devient essentielle. En utilisant cette norme en conjonction avec la EN 62109-1, les concepteurs et fabricants de produits d'onduleurs peuvent s'assurer qu'ils respectent des règles de sécurité rigoureuses, renforçant ainsi la confiance des utilisateurs et des installateurs. L'importance de cette norme dans le secteur des énergies renouvelables ne peut être sous-estimée, car elle contribue à établir des standards de sécurité minimaux qui protègent non seulement le matériel, mais aussi les utilisateurs et les infrastructures.
SIST EN 62109-2:2011 표준은 태양광 발전 시스템에서 사용되는 전력 변환 기기의 안전성에 관한 요구사항을 규명하고 있습니다. 이 표준은 직류(DC)를 교류(AC)로 변환하는 인버터 제품에 대한 특정 안전 요구사항을 다루며, 다른 기능을 수행하는 제품 또한 포함됩니다. 특히, 태양광 발전 시스템에 사용하기 위한 인버터로 설계된 제품에 적용됩니다. 이 표준의 주요 강점 중 하나는 다양한 유형의 인버터를 포괄적으로 아우른다는 점입니다. 그리드 인터랙티브, 독립형, 다중 모드 인버터를 모두 포함하며, 이는 단일 또는 다수의 태양광 모듈로 구성된 다양한 배열 설정에서 사용될 수 있습니다. 또한, 배터리나 기타 에너지 저장 장치와 함께 사용될 수 있도록 설계된 인버터에 대해서도 적용됩니다. 이러한 포괄성 덕분에 SIST EN 62109-2:2011은 다양한 설치 환경과 응용 프로그램에 따른 안전 기준을 제공하여, 사용자와 설치자에게 신뢰성을 높이는 데 기여합니다. 또한, 이 표준은 IEC 62109-1과 함께 사용되어야 하며, 이는 인버터 제품의 안전성을 더 강화하는 역할을 합니다. 이러한 결합 사용은 제품의 다양한 전기적, 기계적 특성을 포괄적으로 고려하여 최상의 안전 기준을 설정하는 데 필수적입니다. 결론적으로, SIST EN 62109-2:2011 표준은 태양광 발전 인버터 제품의 안전성 강화를 위한 필수적인 문서로, 태양광 산업의 발전에 중대한 기여를 하고 있습니다. 이 표준이 제공하는 요구사항은 시장에서의 신뢰성과 지속 가능성을 높이는 데 중요한 역할을 하며, 태양광 시스템의 효율성과 안전성을 보장하는 데 핵심적입니다.
The EN 62109-2:2011 standard provides a comprehensive framework for ensuring the safety of power converters specifically designed for photovoltaic power systems. This standard is essential in defining the safety requirements for direct current (d.c.) to alternating current (a.c.) inverter products, which are critical components in solar energy systems. One of the significant strengths of EN 62109-2:2011 lies in its broad scope, which includes inverters that may not only function as standalone units but also perform additional functions alongside their inverter capability. This versatility makes it relevant for various applications, encompassing grid-interactive inverters, stand-alone systems, and multi-mode operation. The inclusion of specifications for inverters used with single or multiple photovoltaic modules in diverse array configurations enhances its applicability in real-world solar energy installations. Moreover, this standard places emphasis on safety in conjunction with energy storage systems, such as batteries. This is particularly pertinent as the integration of energy storage becomes increasingly critical in maximizing the efficiency and effectiveness of photovoltaic power systems. By addressing this aspect, the standard not only helps to ensure the safety of inverter products but also promotes the development and deployment of innovative solar energy solutions that incorporate storage technologies. The need for EN 62109-2:2011 to be used in tandem with IEC 62109-1 further reinforces its relevance, highlighting the importance of a holistic approach to safety in power converter technology. By adhering to these standards, manufacturers and installers can ensure that their products meet rigorous safety requirements, ultimately protecting end-users and fostering confidence in photovoltaic systems. In summary, the EN 62109-2:2011 standard is a critical document that provides essential guidelines for the safety of inverters in photovoltaic systems. Its comprehensive scope, focus on safety in diverse operational contexts, and requirement for alignment with IEC 62109-1 underline its significance in promoting safe and effective solar energy solutions.
Die Norm EN 62109-2:2011 beschäftigt sich mit der Sicherheit von Stromwandlern für den Einsatz in photovoltaischen Energiesystemen und umfasst spezifische Anforderungen für Gleichstrom-zu-Wechselstrom-Wechselrichter. Ihr Anwendungsbereich ist klar definiert: Die Norm gilt für Produkte, die Wechselrichterfunktionen ausführen oder solche Produkte beinhalten, die für den Einsatz in photovoltaischen Systemen bestimmt sind. Einer der größten Stärken dieser Norm ist ihre umfassende Betrachtung der unterschiedlichen Typen von Wechselrichtern, darunter netzinteraktive, autonome und multimodale Wechselrichter. Dies stellt sicher, dass eine breite Palette von Einsatzmöglichkeiten abgedeckt wird, was für Hersteller und Anwender von großer Bedeutung ist. Zudem werden in dieser Norm auch spezifische Anforderungen für Wechselrichter berücksichtigt, die mit verschiedenen Konfigurationen von photovoltaischen Modulen und Energiespeichersystemen, wie Batterien, zusammenarbeiten. Die Relevanz der EN 62109-2:2011 wird durch die zunehmende Integration von erneuerbaren Energien in das Stromnetz und die steigende Nachfrage nach sicheren und effizienten Systemen untermauert. Durch die Einhaltung dieser Norm können Hersteller sicherstellen, dass ihre Produkte nicht nur den Sicherheitsstandards entsprechen, sondern auch die Zuverlässigkeit und Effizienz der photovoltaischen Systeme verbessern. Ebenso wird darauf hingewiesen, dass diese Norm in Verbindung mit IEC 62109-1 verwendet werden muss, was die Notwendigkeit einer dualen Sichtweise auf die Sicherheit von Wechselrichtern und deren Vielzahl an Einsatzmöglichkeiten hervorhebt. Zusammenfassend lässt sich sagen, dass die EN 62109-2:2011 eine wesentliche Norm für Hersteller, Betreiber und Anwender von photovoltaischen Energiesystemen darstellt, indem sie spezifische Sicherheitsanforderungen definiert und somit eine wichtige Rolle bei der Gewährleistung der Sicherheit und Effizienz von Wechselrichtern spielt.








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...