EN 61000-3-2:1995
(Main)Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)
Specifies limits for harmonic current emissions applicable to electrical and electronic equipment having an input current up to and including 16 A per phase, and intended to be connected to public low-voltage distribution systems. The tests according to this standard are type tests. Test conditions for particular equipment are given in annex C. For systems with nominal voltages less than 220 V (line to neutral), the limits have not yet been considered.
Elektromagnetische Verträglichkeit (EMV) - Teil 3-2: Grenzwerte - Grenzwerte für Oberschwingungsströme (Geräte-Eingangsstrom bis einschließlich 16 A je Leiter)
Compatibilité électromagnétique (CEM) - Partie 3-2: Limites - Limites pour les émissions de courant harmonique (courant appelé par les appareils inférieur ou égal à 16 A par phase)
Définit les limites pour les émissions de courant harmonique applicables aux appareils électriques et électroniques ayant un courant d'entrée dont la valeur est inférieure ou égale à 16 A par phase et qui sont destinés à être raccordés à des réseaux publics de distribution à basse tension. Les essais effectués conformément à la présente norme sont des essais de type. Les conditions d'essais pour des appareils particuliers sont indiquées à l'annexe C. Pour les systèmes alimentés par des réseaux dont la tension nominale est inférieure à 220 V (phase par rapport au neutre), les limites n'ont pas encore été envisagées.
Electromagnetic compatibility (EMC) - Part 3: Limits - Section 2: Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) (Supersedes EN 60555-2:1987) (IEC 1000-3-2:1995)
General Information
- Status
- Withdrawn
- Publication Date
- 05-Apr-1995
- Technical Committee
- CLC/TC 210 - Electromagnetic Compatibility (EMC)
- Drafting Committee
- IEC/SC 77A - IEC_SC_77A
- Parallel Committee
- IEC/SC 77A - IEC_SC_77A
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Jan-2004
- Completion Date
- 01-Jan-2004
- Mandate
- BC/CLC/92-02 - BC/CLC/92-02
Relations
- Effective Date
- 29-Jan-2023
- Effective Date
- 29-Jan-2023
- Effective Date
- 28-Jan-2023
- Effective Date
- 09-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 09-Feb-2026
- Referred By
EN 61326:1997 - Electrical equipment for measurement, control and laboratory use - EMC requirements - Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard

Intertek Testing Services NA Inc.
Intertek certification services in North America.

UL Solutions
Global safety science company with testing, inspection and certification.

ANCE
Mexican certification and testing association.
Sponsored listings
Frequently Asked Questions
EN 61000-3-2:1995 is a standard published by CLC. Its full title is "Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)". This standard covers: Specifies limits for harmonic current emissions applicable to electrical and electronic equipment having an input current up to and including 16 A per phase, and intended to be connected to public low-voltage distribution systems. The tests according to this standard are type tests. Test conditions for particular equipment are given in annex C. For systems with nominal voltages less than 220 V (line to neutral), the limits have not yet been considered.
Specifies limits for harmonic current emissions applicable to electrical and electronic equipment having an input current up to and including 16 A per phase, and intended to be connected to public low-voltage distribution systems. The tests according to this standard are type tests. Test conditions for particular equipment are given in annex C. For systems with nominal voltages less than 220 V (line to neutral), the limits have not yet been considered.
EN 61000-3-2:1995 is classified under the following ICS (International Classification for Standards) categories: 29.020 - Electrical engineering in general. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 61000-3-2:1995 has the following relationships with other standards: It is inter standard links to EN 60555-1:1987, EN 60555-2:1987, EN 61000-3-2:2000, EN 13589:2003, EN 60335-2-7:1997, EN 61000-4-7:1993, EN 60155:1995, ENV 61000-2-2:1993, HD 483.3 S2:1992, EN 1776:2025, EN 61326:1997, EN 60669-2-1:2000, EN 60947-5-2:1997, EN 60669-2-1:1996, EN 60730-1:2000. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 61000-3-2:1995 is associated with the following European legislation: EU Directives/Regulations: 1999/5/EC, 2004/108/EC, 2004/108/EU, 89/336/EEC; Standardization Mandates: BC/CLC/92-02. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 61000-3-2:1995 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-1997
1DGRPHãþD
SIST EN 60555-2:1995
Electromagnetic compatibility (EMC) - Part 3: Limits - Section 2: Limits for
harmonic current emissions (equipment input current up to and including 16 A per
phase) (Supersedes EN 60555-2:1987) (IEC 1000-3-2:1995)
Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current
emissions (equipment input current up to and including 16 A per phase)
Elektromagnetische Verträglichkeit (EMV) -- Teil 3-2: Grenzwerte - Grenzwerte für
Oberschwingungsströme (Geräte-Eingangsstrom bis einschließlich 16 A je Leiter)
Compatibilité électromagnétique (CEM) -- Partie 3-2: Limites - Limites pour les émissions
de courant harmonique (courant appelé par les appareils inférieur ou égal à 16 A par
phase)
Ta slovenski standard je istoveten z: EN 61000-3-2:1995
ICS:
33.100.10 Emisija Emission
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
--------------------
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...