Pumps - Rotodynamic pumps - Circulation pumps having a rated power input not exceeding 200 W for heating installations and domestic hot water installations - Part 1: Non-automatic circulation pumps, requirements, testing, marking

CMC/TC - Foreword - Correction of the superseding note, mistake happened by writing the comment "Revision of EN 1151:1999 into 2 parts (see also WI 052)." into the database. The superseding note has been extended during each publication step and it has always been missed to correct even during CA/7 publication. The superseding not was correct in the Enquiry version.

Pumpen - Kreiselpumpen - Umwälzpumpen mit elektrischer Leistungsaufnahme bis 200 W für Heizungsanlagen und Brauchwassererwärmungsanlagen für den Hausgebrauch - Teil 1: Nicht-automatische Umwälzpumpen, Anforderungen, Prüfung, Kennzeichnung

Pompes - Pompes rotodynamiques - Circulateurs de puissance absorbée n'excédant pas 200 W, destinés aux installations de chauffage central et d'eau chaude sanitaire domestique - Partie 1: Circulateurs non auto-régulés, exigences, essais, marquage

Črpalke - Centrifugalne črpalke - Obtočne črpalke z naznačeno vhodno močjo do največ 200 W za grelne inštalacije in gospodinjske toplovodne inštalacije - 1. del: Neavtomatske obtočne črpalke, zahteve, preskušanje in označevanje

General Information

Status
Withdrawn
Publication Date
23-Oct-2007
Withdrawal Date
16-Oct-2012
Technical Committee
CEN/TC 197 - Pumps
Drafting Committee
CEN/TC 197 - Pumps
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
17-Oct-2012
Completion Date
17-Oct-2012

Relations

Effective Date
24-Oct-2012
Effective Date
24-Oct-2012
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
08-Jun-2022
Corrigendum

EN 1151-1:2007/AC:2008

English, French and German language
2 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

EN 1151-1:2006/AC:2007 is a corrigendum published by the European Committee for Standardization (CEN). Its full title is "Pumps - Rotodynamic pumps - Circulation pumps having a rated power input not exceeding 200 W for heating installations and domestic hot water installations - Part 1: Non-automatic circulation pumps, requirements, testing, marking". This standard covers: CMC/TC - Foreword - Correction of the superseding note, mistake happened by writing the comment "Revision of EN 1151:1999 into 2 parts (see also WI 052)." into the database. The superseding note has been extended during each publication step and it has always been missed to correct even during CA/7 publication. The superseding not was correct in the Enquiry version.

CMC/TC - Foreword - Correction of the superseding note, mistake happened by writing the comment "Revision of EN 1151:1999 into 2 parts (see also WI 052)." into the database. The superseding note has been extended during each publication step and it has always been missed to correct even during CA/7 publication. The superseding not was correct in the Enquiry version.

EN 1151-1:2006/AC:2007 is classified under the following ICS (International Classification for Standards) categories: 23.080 - Pumps. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 1151-1:2006/AC:2007 has the following relationships with other standards: It is inter standard links to EN 16297-2:2012, EN 16297-1:2012, EN ISO 6744-3:2004, EN ISO 6744-2:2004, EN ISO 6744-1:2004, EN 1151-1:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 1151-1:2006/AC:2007 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Pumps - Rotodynamic pumps - Circulation pumps having a rated power input not exceeding 200 W for heating installations and domestic hot water installations - Part 1: Non-automatic circulation pumps, requirements, testing, markingPompes - Pompes rotodynamiques - Circulateurs de puissance absorbée n'excédant pas 200 W, destinés aux installations de chauffage central et d'eau chaude sanitaire domestique - Partie 1: Circulateurs non auto-régulés, exigences, essais, marquagePumpen - Kreiselpumpen - Umwälzpumpen mit elektrischer Leistungsaufnahme bis 200 W für Heizungsanlagen und Brauchwassererwärmungsanlagen für den Hausgebrauch - Teil 1: Nicht-automatische Umwälzpumpen, Anforderungen, Prüfung, KennzeichnungTa slovenski standard je istoveten z:EN 1151-1:2006/AC:2007SIST EN 1151-1:2007/AC:2008en,fr,de23.080ýUSDONHPumpsICS:SLOVENSKI
STANDARDSIST EN 1151-1:2007/AC:200801-januar-2008

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 1151-1:2006/ACOctober 2007Octobre 2007Oktober 2007ICS 23.080English versionVersion FrançaiseDeutsche FassungPumps - Rotodynamic pumps - Circulation pumps having a rated powerinput not exceeding 200 W for heating installations and domestic hot waterinstallations - Part 1: Non-automatic circulation pumps, requirements,testing, markingPompes - Pompes rotodynamiques -Circulateurs de puissance absorbéen'excédant pas 200 W, destinés auxinstallations de chauffage central et d'eauchaude sanitaire domestique - Partie 1:Circulateurs non auto-régulés, exigences,essais, marquagePumpen - Kreiselpumpen - Umwälz
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...