Chimneys - System chimneys with clay/ceramic flue liners - Part 2: Requirements and test methods under wet conditions

This European Standard specifies the requirements and test methods for multiwall system chimneys working under wet conditions (in the following expressed as wet chimney) with pressure
type N1, N2 or P1 according to EN 1443 and a working temperature below or equal T600 according to !EN 13063-1:2005+A1", in which the products of combustion are conveyed to the atmosphere through clay/ceramic flue liners. Marking and inspection are also covered by this document.
This European Standard does not apply to structurally independent (free standing or self supporting) system chimneys.
The wet chimney may comprise the following appropriate components:
   clay/ceramic flue liners;
   insulation layer;
   outer walls;
   acid resistant mortar for jointing flue liners or elastomeric sealant;
   mortar for jointing outer walls;
   terminal;
   chimney base;
   condensate collector;
   condensate outlet;
   cladding;
   opening section;
   cleaning and inspection door;
   distance piece;
   reinforcement.
The wet system chimney covers a combination of compatible chimney components, obtained or specified from one manufacturing source with product responsibility for the whole system chimney.
NOTE   This document does not cover soot fire resistance chimneys.

Abgasanlagen - System-Abgasanlagen mit Keramik-Innenrohren - Teil 2: Anforderungen und Prüfungen für feuchte Betriebsweise

Conduits de fumées - Conduits-systèmes avec conduit intérieur en terre cuite/céramique - Partie 2 : Exigences et méthodes d'essai en conditions humides

La présente norme européenne spécifie les exigences et les méthodes d'essai applicables aux conduits-systèmes multiparois fonctionnant en ambiance humide (ci-après désignés «conduits de fumées humides»), avec une pression de type N1, N2 ou P1 conformément à l'EN 1443 et une température de fonctionnement inférieure ou égale à T600 conformément !à l'EN 13063-1:2005+A1", dans lesquels les produits de combustion sont acheminés vers l'atmosphère via des conduits intérieurs en terre cuite/céramique. Cette norme concerne également le marquage et le contrôle.
La présente norme ne s'applique pas aux conduits-systèmes indépendants au niveau structurel (autoporteurs ou autonomes).
Le conduit de fumée humide peut comporter les éléments suivants :
   un conduit intérieur en terre cuite/céramique ;
   une couche d'isolation ;
   des parois extérieures ;
   du mortier résistant aux acides pour jointoyer les conduits intérieurs ou un matériau d'étanchéité élastomère ;
   du mortier pour jointoyer les parois extérieures ;
   un couronnement ;
   une base ;
   un collecteur de condensats ;
   un orifice de sortie des condensats ;
   un habillage ;
   une ouverture ;
   une trappe de nettoyage et de visite ;
   une entretoise ;
   un renfort.
Le conduit-système humide englobe un ensemble d'éléments compatibles, fournis ou conseillés par un fabricant assumant la responsabilité du produit pour le conduit-système dans son intégralité.
NOTE   Le présent document ne s’applique pas aux conduits de cheminée résistant aux feux de cheminée.

Dimovodne naprave - Sistemski dimniki s keramičnimi tuljavami - 2. del: Zahteve in preskusne metode za obratovanje v vlažnih pogojih

Ta evropski standard določa zahteve in preskusne metode za večslojne sistemske dimovodne naprave, ki obratujejo v vlažnih pogojih (v nadaljevanju: dimovodna naprava za obratovanje v vlažnem), s tlakom tipa N1, N2 ali P1 v skladu s standardom EN 1443 in delovno temperaturo, nižjo ali enako T600 v skladu s standardom   EN 13063-1:2005+A1  , pri katerih se produkti zgorevanja odvajajo v ozračje prek keramičnih dimovodnih tuljav. Ta dokument zajema tudi označevanje in pregledovanje.
Ta evropski standard se ne uporablja za konstrukcijsko neodvisne (samostoječe ali samonosilne) sistemske dimovodne naprave.
Dimovodno napravo za obratovanje v vlažnem lahko sestavljajo naslednji ustrezni sestavni deli:
–   keramične dimovodne tuljave,
–   izolacijski sloj,
–   zunanji plašči,
–   malta, odporna proti kislinam, za spajanje dimovodnih tuljav ali elastomerna tesnilna masa,
–   malta za spajanje zunanjih plaščev,
–   zaključni element,
–   temelj dimovodne naprave,
–   zbiralnik kondenzata,
–   odvod kondenzata,
–   obloga dimovodne naprave,
–   element z odprtino,
–   vratca za čiščenje in pregledovanje,
–   distančnik,
–   ojačitev.
Sistemska dimovodna naprava za obratovanje v vlažnem je kombinacija med seboj združljivih sestavnih delov, ki jih je dobavil ali določil en sam proizvajalec, ki prevzema odgovornost za celotno dimovodno napravo.
OPOMBA: Ta dokument ne zajema dimovodnih naprav, odpornih proti požaru saj

General Information

Status
Published
Publication Date
17-Jul-2007
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
06-May-2021

Relations

Buy Standard

Standard
EN 13063-2:2005+A1:2007
English language
39 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
EN 13063-2:2005+A1:2007
English language
39 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard – translation
EN 13063-2:2005+A1:2007
Slovenian language
40 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Chimneys - System chimneys with clay/ceramic flue liners - Part 2: Requirements and test methods under wet conditionsConduits de cheminées - Conduits de cheminées résistant aux feux de cheminées a paroi intérieure en terre cuite/céramique - Partie 2: Exigences et méthodes d'essai en conditions humidesAbgasanlagen - System-Abgasanlagen mit Keramik-Innenrohren - Teil 2: Anforderungen und Prüfungen für feuchte BetriebsweiseTa slovenski standard je istoveten z:EN 13063-2:2005+A1:2007SIST EN 13063-2:2005+A1:2007en,fr,de91.060.40Dimniki, jaški, kanaliChimneys, shafts, ductsICS:SLOVENSKI
STANDARDSIST EN 13063-2:2005+A1:200701-september-2007

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13063-2:2005+A1
July 2007 ICS 91.060.40 Supersedes EN 13063-2:2005 English Version
Chimneys - System chimneys with clay/ceramic flue liners - Part 2: Requirements and test methods under wet conditions
Conduits de cheminées - Conduits de cheminées résistant aux feux de cheminées à paroi intérieure en terre cuite/céramique - Partie 2: Exigences et méthodes d'essai en conditions humides
Abgasanlagen - System-Abgasanlagen mit Keramik-Innenrohren - Teil 2: Anforderungen und Prüfungen für feuchte Betriebsweise This European Standard was approved by CEN on 1 April 2005 and includes Amendment 1 approved by CEN on 14 June 2007.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2007 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13063-2:2005+A1:2007: E

Test methods.18 Annex B (informative)
Thermal resistance.27 Annex C (normative)
Sampling procedures for an AQL of 10 % and inspection level S2.28 Annex ZA (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive.32 Bibliography.39

type N1, N2 or P1 according to EN 1443 and a working temperature below or equal T600 according to !EN 13063-1:2005+A1", in which the products of combustion are conveyed to the atmosphere through clay/ceramic flue liners. Marking and inspection are also covered by this document. This European Standard does not apply to structurally independent (free standing or self-supporting) system chimneys. The wet chimney may comprise the following appropriate components:  clay/ceramic flue liners;  insulation layer;  outer walls;  acid resistant mortar for jointing flue liners or elastomeric sealant;  mortar for jointing outer walls;  terminal;  chimney base;  condensate collector;  condensate outlet;  cladding;  opening section;  cleaning and inspection door;  distance piece;  reinforcement. The wet system chimney covers a combination of compatible chimney components, obtained or specified from one manufacturing source with product responsibility for the whole system chimney. NOTE This document does not cover soot fire resistance chimneys.

3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in EN 1443:2003,
EN 13216-1:2004, !EN 13063-1:2005+A1:2007" and the following apply. 3.1 system chimney under wet conditions system chimney is a multiwall construction, consisting mainly of an outer wall, an insulation layer and the inner clay/ceramic flue liner that can work under wet conditions (see Figure 1)

Key 1 flue liner 2 insulation layer 3 outer wall 4 back ventilation 5 cavities for structural reinforcement 6 non ventilated air gap Figure 1 — Examples of construction of a chimney for wet conditions 3.2 wet operating conditions conditions when the chimney is designed to operate normally with the temperature of the inner surface of the flue liner at and below the water dew point 3.3 condensate collector flue liner base unit for collecting the condensates with an opening for discharging the condensates 3.4 condensate outlet drain to ensure the discharge of the condensates from the condensates collector 3.5 jointing materials for flue liners 3.5.1 prefabricated elastomeric seals prefabricated element made of elastomeric material, which ensures a gastight seal in a joint

EN 12446:2003, Clause 7;  clay/ceramic outer walls:
!EN 13069:2005", Clause 6;  metal outer walls:
!EN 13063-1:2005+A1:2007", Annex B. 4.4 Cleaning and inspection doors Dimensions and tolerances shall be declared by the manufacturers. 5 Material requirements 5.1 General requirements for components 5.1.1 Flue liners Flue liners shall meet the requirements of EN 14571999, 8.1, 9.1, 9.2, Clauses 10, 11, 12 and 13. If the requirement of EN 1457:1999, 13.1 "Water vapour permeability" is not fulfilled, the flue liner may be used for wet chimneys, if the system test for system chimneys under wet conditions according to
!EN 13216-1:2004, 5.6, is passed according to the requirements in 5.3.2.1."

5.1.5 Outer wall elements Outer wall elements shall fulfil EN 12446 for concrete outer wall elements, !EN 13069" for clay/ceramic outer wall or Annex B of !EN 13063-1:2005+A1:2007" for metal outer
...


SLOVENSKI STANDARD
01-september-2007
Dimovodne naprave – Sistemski dimniki s keramičnimi tuljavami – 2. del: Zahteve
in preskusne metode za obratovanje v vlažnih pogojih
Chimneys - System chimneys with clay/ceramic flue liners - Part 2: Requirements and
test methods under wet conditions
Abgasanlagen - System-Abgasanlagen mit Keramik-Innenrohren - Teil 2: Anforderungen
und Prüfungen für feuchte Betriebsweise
Conduits de cheminées - Conduits de cheminées résistant aux feux de cheminées a
paroi intérieure en terre cuite/céramique - Partie 2: Exigences et méthodes d'essai en
conditions humides
Ta slovenski standard je istoveten z: EN 13063-2:2005+A1:2007
ICS:
91.060.40 Dimniki, jaški, kanali Chimneys, shafts, ducts
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 13063-2:2005+A1
NORME EUROPÉENNE
EUROPÄISCHE NORM
July 2007
ICS 91.060.40 Supersedes EN 13063-2:2005
English Version
Chimneys - System chimneys with clay/ceramic flue liners - Part
2: Requirements and test methods under wet conditions
Conduits de cheminées - Conduits de cheminées résistant Abgasanlagen - System-Abgasanlagen mit Keramik-
aux feux de cheminées à paroi intérieure en terre Innenrohren - Teil 2: Anforderungen und Prüfungen für
cuite/céramique - Partie 2: Exigences et méthodes d'essai feuchte Betriebsweise
en conditions humides
This European Standard was approved by CEN on 1 April 2005 and includes Amendment 1 approved by CEN on 14 June 2007.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN Management Centre or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the
official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2007 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13063-2:2005+A1:2007: E
worldwide for CEN national Members.

Contents Page
Foreword .3
1 Scope .4
2 Normative references.5
3 Terms and definitions .5
4 Shapes, dimensions and tolerances .7
5 Material requirements .7
6 Replacement of single components of the system chimney.12
7 Designation .13
8 Product information .14
9 Marking and labelling.15
10 Evaluation of conformity .15
Annex A (normative) Test methods.18
Annex B (informative) Thermal resistance .27
Annex C (normative) Sampling procedures for an AQL of 10 % and inspection level S2 .28
Annex ZA (informative) Clauses of this European Standard addressing the provisions of the
EU Construction Products Directive .32
Bibliography.39

Foreword
This document (EN 13063-2:2005+A1:2007) has been prepared by Technical Committee CEN/TC 166
“Chimneys”, the secretariat of which is held by UNI.
This document shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by January 2008 and conflicting national standards shall be withdrawn at the
latest by April 2009.
This document includes Amendment 1 approved by CEN on 2007-06-14.
This document supersedes EN 13063-2:2005.
The start and finish of text introduced or altered by amendment is indicated in the text by tags ! ".
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document.
This document is part 2 of a series of standards for system chimneys with clay/ceramic flue liners.
Part 1 is for chimneys with sootfire resistance and part 3 is for system air flue chimneys.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and United Kingdom.

1 Scope
This European Standard specifies the requirements and test methods for multiwall system chimneys
working under wet conditions (in the following expressed as “wet chimney”) with pressure
type N1, N2 or P1 according to EN 1443 and a working temperature below or equal T600 according
to !EN 13063-1:2005+A1", in which the products of combustion are conveyed to the atmosphere
through clay/ceramic flue liners. Marking and inspection are also covered by this document.
This European Standard does not apply to structurally independent (free standing or self-supporting)
system chimneys.
The wet chimney may comprise the following appropriate components:
 clay/ceramic flue liners;
 insulation layer;
 outer walls;
 acid resistant mortar for jointing flue liners or elastomeric sealant;
 mortar for jointing outer walls;
 terminal;
 chimney base;
 condensate collector;
 condensate outlet;
 cladding;
 opening section;
 cleaning and inspection door;
 distance piece;
 reinforcement.
The wet system chimney covers a combination of compatible chimney components, obtained or specified
from one manufacturing source with product responsibility for the whole system chimney.
NOTE This document does not cover soot fire resistance chimneys.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 998-2:2003,!Specification for mortar for masonry – Part 2: Masonry mortar"
EN 1366-8,!Fire resistance tests for service installations – Part 8: Smoke extraction ducts"
EN 1443:2003, Chimneys – General requirements
EN 1457:1999, Chimneys – Clay/ceramic flue liners – Requirements and test methods
EN 12446:2003, Chimneys – Components – Concrete outer wall elements
!EN 13063-1:2005+A1:2007", Chimneys – System chimneys with clay/ceramic flue liners – Part 1:
Requirements and test methods for sootfire resistance
!EN 13069:2005", Chimneys – Clay/ceramic outer walls for system chimneys – Requirements and
test methods
EN 13162:2001, Thermal insulation products for buildings – Factory made mineral wool (MW) products –
Specification
EN 13216-1:2004, Chimneys - Test methods for system chimneys – Part 1: General test methods
EN 13384-1, Chimneys – Thermal and fluid dynamic calculation methods – Part 1: Chimneys serving
one appliance
!EN 14241-1", Chimneys – Elastomeric seals and elastomeric sealants – Material requirements and
test methods - Part 1: Seals in flue liners
EN 14297:2004, Chimneys – Freeze-thaw resistance test method for chimney products
!ISO 2859-1, Sampling procedures for inspection by attributes – Part 1: Sampling schemes indexed by
acceptance quality limit (AQL) for lot-by-lot inspection"

3 Terms and definitions
For the purposes of this European Standard, the terms and definitions given in EN 1443:2003,
EN 13216-1:2004, !EN 13063-1:2005+A1:2007" and the following apply.
3.1
system chimney under wet conditions
system chimney is a multiwall construction, consisting mainly of an outer wall, an insulation layer and the
inner clay/ceramic flue liner that can work under wet conditions (see Figure 1)
Key
1 flue liner
2 insulation layer
3 outer wall
4 back ventilation
5 cavities for structural reinforcement
6 non ventilated air gap
Figure 1 — Examples of construction of a chimney for wet conditions
3.2
wet operating conditions
conditions when the chimney is designed to operate normally with the temperature of the inner surface of
the flue liner at and below the water dew point
3.3
condensate collector
flue liner base unit for collecting the condensates with an opening for discharging the condensates
3.4
condensate outlet
drain to ensure the discharge of the condensates from the condensates collector
3.5
jointing materials for flue liners
3.5.1
prefabricated elastomeric seals
prefabricated element made of elastomeric material, which ensures a gastight seal in a joint
3.5.2
on site applied elastomeric sealant
sealing material which is applied on site to ensure the gas tightness
3.5.3
acid resistant mortar
jointing material made with acid resistant mortar
4 Shapes, dimensions and tolerances
4.1 Flue liners
4.1.1 General
Flue liners shall meet the requirements on size and tolerance of dimensions given in EN 1457:1999, 7.1,
7.2, 7.3, 7.4, 7.5, 7.6 and 7.7.
4.1.2 External diameter of flue liner
When tested in accordance with A.2.6, the external diameter of circular flue liners measured on any
diameter shall not deviate more than ± 3 % of the manufacturer’s stated nominal external diameter.
4.2 Insulation
The insulation layer shall meet the requirements on tolerances of dimension given in EN 13162:2001,
4.2.2 (length and width) and 4.2.3 (thickness class T3).
4.3 Outer wall elements
Outer wall elements shall fulfil the requirements on shapes and tolerances on dimensions given in:
 concrete outer wall elements: EN 12446:2003, Clause 7;
 clay/ceramic outer walls: !EN 13069:2005", Clause 6;
 metal outer walls:  !EN 13063-1:2005+A1:2007", Annex B.
4.4 Cleaning and inspection doors
Dimensions and tolerances shall be declared by the manufacturers.
5 Material requirements
5.1 General requirements for components
5.1.1 Flue liners
Flue liners shall meet the requirements of EN 14571999, 8.1, 9.1, 9.2, Clauses 10, 11, 12 and 13. If the
requirement of EN 1457:1999, 13.1 "Water vapour permeability" is not fulfilled, the flue liner may be used
for wet chimneys, if the system test for system chimneys under wet conditions according to
!EN 13216-1:2004, 5.6, is passed according to the requirements in 5.3.2.1."
5.1.2 Maximum load for opening sections
When tested as described in A.2.3, components shall withstand a load (F) of at least five times the
manufacturer's declared design load (H × G).
χ ×H ×G
F = (1)
where
F is the minimum load, expressed in kilonewton (kN);
χ is the safety factor equal to 5;
H is the height of the chimney, is expressed in meter (m);
G is expressed in kilogram per meter (kg/m).
NOTE The limiting factor of the maximum height of system chimneys is the compressive strength of the
opening section.
5.1.3 Jointing material for flue liners
5.1.3.1 Acid resistant mortar
5.1.3.1.1 Density
The density of jointing material shall not vary more than ± 10 % of the manufacturer's declared value
when tested in accordance with A.2.2.2.
5.1.3.1.2 Compressive strength
The compressive strength shall be tested after a 24 h preconditioning under water in accordance with
A.2.2.3.The compressive strength shall be at least 10 N/mm².
5.1.3.1.3 Water resistance
Acid resistant mortar for jointing the components in system chimneys stated for use in wet conditions
shall be tested in accordance with A.2.2.4 and the mass loss from any sample shall not exceed 3 %.
5.1.3.1.4 Acid resistance
...


ba
SLOVENSKI SIST EN 13063-2:2005+A1

STANDARD
september 2007
Dimovodne naprave – Sistemske dimovodne naprave s keramičnimi
dimovodnimi tuljavami – 2. del: Zahteve in preskusne metode za
obratovanje v vlažnih pogojih
Chimneys – System chimneys with clay/ceramic flue liners –
Part 2: Requirements and test methods under wet conditions

Abgasanlagen – System-Abgasanlagen mit Keramik-Innenrohren –
Teil 2: Anforderungen und Prüfungen für feuchte Betriebsweise

Conduits de cheminées – Conduits de cheminées résistant aux feux de
cheminées a paroi intérieure en terre cuite/céramique – Partie 2: Exigences et
méthodes d'essai en conditions humides

Referenčna oznaka
ICS 91.060.40 SIST EN 13063-2:2005+A1:2007 (sl)

Nadaljevanje na straneh II do III in od 1 do 37

© 2020-03. Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

SIST EN 13063-2:2005+A1 : 2007
NACIONALNI UVOD
Standard SIST EN 13063-2:2005+A1 (sl), Dimovodne naprave – Sistemske dimovodne naprave s
keramičnimi dimovodnimi tuljavami – 2. del: Zahteve in preskusne metode za obratovanje v vlažnih
pogojih, 2007, ima status slovenskega standarda in je istoveten evropskemu standardu EN 13063-
2:2005+A1 (en, de, fr), Chimneys – System chimneys with clay/ceramic flue liners – Part 2:
Requirements and test methods under wet conditions, 2007.

Ta standard nadomešča SIST EN 13063-2:2005.

NACIONALNI PREDGOVOR
Evropski standard EN 13063-2:2005+A1:2007 je pripravil tehnični odbor Evropskega komiteja za
standardizacijo CEN/TC 166 Dimovodne naprave. Slovenski standard SIST EN 13063-2:2005+A1:2007
je prevod evropskega standarda EN 13063-2:2005+A1:2007 v angleškem jeziku. V primeru spora glede
besedila slovenskega prevoda v tem standardu je odločilen izvirni evropski standard v enem izmed treh
uradnih jezikov CEN. Slovensko izdajo standarda je pripravil tehnični odbor SIST/TC POZ Požarna
varnost.
Odločitev za privzem tega standarda je julija 2007 sprejel SIST/TC POZ Požarna varnost.

ZVEZA S STANDARDI
S privzemom tega evropskega standarda veljajo za omejeni namen referenčnih standardov vsi
standardi, navedeni v izvirniku, razen tistih, ki so že sprejeti v nacionalno standardizacijo:
SIST EN 998-2:2004 Specifikacija malt za zidanje – 2. del: Malta za zidanje
SIST EN 1366-8 Preskusi požarne odpornosti servisnih inštalacij – 8. del: Kanali za
odvod dima
SIST EN 1443:2003 Dimovodne naprave – Splošne zahteve
SIST EN 1457:1999 Dimniki – Keramične tuljave – Zahteve in preskusne metode
SIST EN 12446:2003 Dimniki – Sestavni deli – Betonski elementi (nosilnega) plašča
dimnika
SIST EN 13063-1:2006+A1:2007 Dimovodne naprave – Sistemske dimovodne naprave s keramičnimi
dimovodnimi tuljavami – 1. del: Zahteve za odpornost proti požaru
saj in preskusne metode
SIST EN 13069:2006 Dimniki – Keramični (zunanji) plašči za sistemske dimnike – Zahteve
in preskusne metode
SIST EN 13162:2001  Toplotnoizolacijski proizvodi za stavbe – Proizvodi iz mineralne
volne (MW) – Specifikacija
SIST EN 13216-1:2004 Dimovodne naprave – Preskusne metode za sistemske dimovodne
naprave – 1. del: Splošne preskusne metode
SIST EN 13384-1 Dimniki – Računske metode termodinamike in dinamike fluidov –
1. del: Dimniki za eno ogrevalno napravo
SIST EN 14241-1 Dimniki – Elastomerna tesnilna sredstva – Zahteve za material in
preskusne metode – 1. del: Tesnila v dimničnih tuljavah
SIST EN 14297:2004 Dimovodne naprave – Metoda preskušanja odpornosti dimniških
proizvodov proti zmrzovanju in tajanju
SIST ISO 2859-1 Postopki vzorčenja pri kontroli po opisnih (atributivnih)
spremenljivkah – 1. del: Pravila vzorčenja razvrščena po prevzemni
meji kakovosti (AQL) za kontrolo zaporednih partij (lotov)

II
SIST EN 13063-2:2005+A1 : 2007
OSNOVA ZA IZDAJO STANDARDA
– privzem standarda EN 13063-2:2005+A1:2007

PREDHODNA IZDAJA
– SIST EN 13063-2:2005, Dimniki – Sistemski dimniki s keramičnimi tuljavami – 2. del: Zahteve in
preskusne metode za delovanje v vlažnih razmerah

OPOMBE
– Povsod, kjer se v besedilu standarda uporablja izraz "evropski standard", v SIST EN 13063-
2:2005+A1:2007 to pomeni "slovenski standard".
– Nacionalni uvod in nacionalni predgovor nista sestavni del standarda.
– Ta nacionalni dokument je istoveten EN 13063-2:2005+A1:2007 in je objavljen z dovoljenjem

CEN-CENELEC
Upravni center
Rue de Stassart 36
B-1050 Bruselj
This national document is identical with EN 13063-2:2005+A1:2007 and is published with the
permission of
CEN-CENELEC
Management Centre
Rue de Stassart, 36
B-1050 Brussels
III
SIST EN 13063-2:2005+A1 : 2007

(prazna stran)
IV
EVROPSKI STANDARD      EN 13063-2:2005+A1
EUROPEAN STANDARD
NORME EUROPÉENNE
julij 2007
EUROPÄISCHE NORM
ICS 91.060.40 Nadomešča EN 13063-2:2005

Slovenska izdaja
Dimovodne naprave – Sistemske dimovodne naprave s keramičnimi
dimovodnimi tuljavami – 2. del: Zahteve in preskusne metode za
obratovanje v vlažnih pogojih
Chimneys – System chimneys Conduits de cheminées – Abgasanlagen – System-
with clay/ceramic flue liners – Conduits de cheminées Abgasanlagen mit Keramik-
Part 2: Requirements and test résistant aux feux de cheminées Innenrohren – Teil 2:
methods under wet conditi a paroi intérieure en terre Anforderungen und Prüfungen
cuite/céramique – Partie 2: für feuchte Betriebsweise
Exigences et méthodes d'essai
en conditions humides
Ta evropski standard je CEN sprejel 1. aprila 2005 in vključuje dopolnilo 1, ki ga je CEN sprejel 14. junija
2007.
Člani CEN morajo izpolnjevati določila notranjih predpisov CEN/CENELEC, s katerimi je predpisano,
da mora biti ta evropski standard brez kakršnihkoli sprememb sprejet kot nacionalni standard. Seznami
najnovejših izdaj teh nacionalnih standardov in njihovi bibliografski podatki so na voljo pri Upravnem
centru CEN ali članih CEN.
Ta evropski standard obstaja v treh uradnih izdajah (angleški, francoski in nemški). Izdaje v drugih jezikih,
ki jih člani CEN na lastno odgovornost prevedejo in izdajo ter prijavijo pri Upravnem centru CEN, veljajo
kot uradne izdaje.
Člani CEN so nacionalni organi za standarde Avstrije, Belgije, Bolgarije, Cipra, Češke republike, Danske,
Estonije, Finske, Francije, Grčije, Irske, Islandije, Italije, Latvije, Litve, Luksemburga, Madžarske, Malte,
Nemčije, Nizozemske, Norveške, Poljske, Portugalske, Romunije, Slovaške, Slovenije, Španije,
Švedske, Švice in Združenega kraljestva.

CEN
Evropski komite za standardizacijo
European Committee for Standardization
Comité Européen de Normalisation
Europäisches Komitee für Normung

Upravni center: rue de Stassart, 36, B-1050 Brussels

© 2007 CEN. Lastnice avtorskih pravic so vse države članice CEN. Ref. oznaka: EN 13063-2:2005+A1:2007 E

SIST EN 13063-2:2005+A1 : 2007
VSEBINA Stran
Predgovor . 3
1 Področje uporabe . 4
2 Zveze s standardi . 4
3 Izrazi in definicije . 5
4 Oblike, mere in tolerance . 7
5 Zahteve za material . 7
6 Zamenjava posameznih sestavnih delov sistemske dimovodne naprave . 12
7 Oznaka . 13
8 Informacije o proizvodu . 14
9 Označevanje in etiketiranje . 15
10 Vrednotenje skladnosti . 15
Dodatek A (normativni): Preskusne metode . 18
Dodatek B (informativni): Toplotna upornost . 27
Dodatek C (normativni): Postopki vzorčenja za raven prevzemne kakovosti 10 % (AQL) in
raven pregleda S2 . 28
Dodatek ZA (informativni): Točke tega evropskega standarda, v katerih so obravnavane
določbe Direktive EU o gradbenih proizvodih . 32
Literatura . 37

SIST EN 13063-2:2005+A1 : 2007
Predgovor
Ta dokument (EN 13063-2:2005+A1:2007) je pripravil tehnični odbor CEN/TC 166 "Dimovodne
naprave", katerega sekretariat vodi UNI.

Ta dokument mora dobiti status nacionalnega standarda bodisi z objavo istovetnega besedila ali z
razglasitvijo najpozneje januarja 2008, nasprotujoče nacionalne standarde pa je treba razveljaviti
najpozneje aprila 2009.
Ta dokument vključuje dopolnilo 1, ki ga je CEN sprejel 14. junija 2007.

Ta dokument nadomešča standard EN 13063-2:2005.

Začetek in konec besedila, dodanega ali spremenjenega z dopolnilom, sta označena z oznakama  .

Ta dokument je bil pripravljen na podlagi mandata, ki sta ga Evropska komisija in Evropsko združenje
za prosto trgovino podelila CEN, in podpira bistvene zahteve direktiv EU.

Za povezavo z direktivo(-ami) Evropske unije glej dodatek ZA, ki je sestavni del tega dokumenta.

Ta dokument je 2. del skupine standardov za sistemske dimovodne naprave s keramičnimi dimovodnimi
tuljavami.
Prvi del obravnava dimovodne naprave, odporne proti požaru saj, in tretji del sistemske dimovodne
naprave z zračnimi dimovodi.
V skladu z notranjimi predpisi CEN/CENELEC morajo ta evropski standard obvezno uvesti nacionalne
organizacije za standardizacijo naslednjih držav: Avstrije, Belgije, Bolgarije, Cipra, Češke republike,
Danske, Estonije, Finske, Francije, Grčije, Irske, Islandije, Italije, Latvije, Litve, Madžarske,
Luksemburga, Malte, Nemčije, Nizozemske, Norveške, Poljske, Portugalske, Romunije, Slovaške,
Slovenije, Španije, Švedske, Švice in Združenega kraljestva.

SIST EN 13063-2:2005+A1 : 2007
1 Področje uporabe
Ta evropski standard določa zahteve in preskusne metode za večslojne sistemske dimovodne naprave,
ki obratujejo v vlažnih pogojih (v nadaljevanju: dimovodna naprava za obratovanje v vlažnem), s tlakom
tipa N1, N2 ali P1 v skladu s standardom EN 1443 in delovno temperaturo, nižjo ali enako T600 v skladu
s standardom EN 13063-1:2005+A1 , pri katerih se produkti zgorevanja odvajajo v ozračje prek
keramičnih dimovodnih tuljav. Ta dokument zajema tudi označevanje in pregledovanje.

Ta evropski standard se ne uporablja za konstrukcijsko neodvisne (samostoječe ali samonosilne)
sistemske dimovodne naprave.
Dimovodno napravo za obratovanje v vlažnem lahko sestavljajo naslednji ustrezni sestavni deli:

– keramične dimovodne tuljave,

– izolacijski sloj,
– zunanji plašči,
– malta, odporna proti kislinam, za spajanje dimovodnih tuljav ali elastomerna tesnilna masa,
– malta za spajanje zunanjih plaščev,
– zaključni element,
– temelj dimovodne naprave,
– zbiralnik kondenzata,
– odvod kondenzata,
– obloga dimovodne naprave,
– element z odprtino,
– vratca za čiščenje in pregledovanje,
– distančnik,
– ojačitev.
Sistemska dimovodna naprava za obratovanje v vlažnem je kombinacija med seboj združljivih sestavnih
delov, ki jih je dobavil ali določil en sam proizvajalec, ki prevzema odgovornost za celotno dimovodno
napravo.
OPOMBA: Ta dokument ne zajema dimovodnih naprav, odpornih proti požaru saj.

2 Zveze s standardi
Za uporabo tega dokumenta so nujni naslednji referenčni dokumenti. Pri datiranih sklicevanjih se
uporablja samo navedena izdaja. Pri nedatiranih sklicevanjih se uporablja zadnja izdaja referenčnega
dokumenta (vključno z morebitnimi dopolnili).

EN 998-2:2003 Specifikacija malt za zidanje – 2. del: Malta za zidanje
EN 1366-8 Preskusi požarne odpornosti servisnih inštalacij – 8. del: Kanali
za odvod dima
EN 1443:2003 Dimovodne naprave – Splošne zahteve
EN 1457:1999 Dimniki – Keramične tuljave – Zahteve in preskusne metode
EN 12446:2003 Dimniki – Sestavni deli – Betonski elementi (nosilnega) plašča
dimnika
SIST EN 13063-2:2005+A1 : 2007
EN 13063-1:2005+A1:2007 Dimovodne naprave – Sistemske dimovodne naprave s keramičnimi
dimovodnimi tuljavami – 1. del: Zahteve za odpornost proti požaru
saj in preskusne metode
EN 13069:2006 Dimniki – Keramični (zunanji) plašči za sistemske dimnike – Zahteve
in preskusne metode
EN 13162:2001  Toplotnoizolacijski proizvodi za stavbe – Proizvodi iz mineralne
volne (MW) – Specifikacija
EN 13216-1:2004 Dimovodne naprave – Preskusne metode za sistemske dimovodne
naprave – 1. del: Splošne preskusne metode
EN 13384-1 Dimniki – Računske metode termodinamike in dinamike fluidov –
1. del: Dimniki za eno ogrevalno napravo
EN 14241-1 Dimniki – Elastomerna tesnilna sredstva – Zahteve za material in
preskusne metode – 1. del: Tesnila v dimničnih tuljavah
EN 14297:2004 Dimovodne naprave – Metoda preskušanja odpornosti dimniških
proizvodov proti zmrzovanju in tajanju
ISO 2859-1 Postopki vzorčenja pri kontroli po opisnih (atributivnih)
spremenljivkah – 1. del: Pravila vzorčenja razvrščena po prevzemni
meji kakovosti (AQL) za kontrolo zaporednih partij (lotov)

3 Izrazi in definicije
V tem
...

Questions, Comments and Discussion