EN 13121-4:2005
(Main)GRP tanks and vessels for use above ground - Part 4: Delivery, installation and maintenance
GRP tanks and vessels for use above ground - Part 4: Delivery, installation and maintenance
This document gives requirements for delivery, installation and maintenance of GRP tanks and vessels in accordance with prEN 13121- 3.
Oberirdische GFK-Tanks und -Behälter - Teil 4: Auslieferung, Aufstellung und Instandhaltung
Dieses Dokument gilt für die Anforderungen für die Auslieferung und die Aufstellung von GFK-Tanks und Behältern nach prEN 13121-3.
Réservoirs et récipients en PRV pour applications hors sol - Partie 4: Livraison, installation et maintenance
Le présent document spécifie les exigences relatives à la livraison, l'installation et la maintenance des
réservoirs et récipients en PRV, conformes au prEN 13121-3.
Nadzemni rezervoarji iz armiranega poliestra - 4. del: Dostava, postavitev in vzdrževanje
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Nadzemni rezervoarji iz armiranega poliestra - 4. del: Dostava, postavitev in vzdrževanjeOberirdische GFK-Tanks und -Behälter - Teil 4: Auslieferung, Aufstellung und InstandhaltungRéservoirs et récipients en PRV pour applications hors sol - Partie 4: Livraison, installation et maintenanceGRP tanks and vessels for use above ground - Part 4: Delivery, installation and maintenance23.020.10UH]HUYRDUMLStationary containers and tanksICS:Ta slovenski standard je istoveten z:EN 13121-4:2005SIST EN 13121-4:2005en01-marec-2005SIST EN 13121-4:2005SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13121-4January 2005ICS 23.020.10English versionGRP tanks and vessels for use above ground - Part 4: Delivery,installation and maintenanceRéservoirs et récipients en PRV pour applications hors sol -Partie 4: Livraison, installation et maintenanceOberirdische GFK-Tanks und -Behälter - Teil 4:Auslieferung, Aufstellung und InstandhaltungThis European Standard was approved by CEN on 12 November 2004.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2005 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13121-4:2005: ESIST EN 13121-4:2005
Allowable lifting methods for straight vertical lift.9 Annex B (informative)
Repositioning of tank/vessel from horizontal to vertical.12 Annex C (informative)
Delivery checklist.15 Annex D (informative)
Installation checklist.16 Annex E (informative)
Guidance notes for maintenance.17 E.1 General.17 E.2 Service conditions.17 E.3 Cleaning and servicing.17 E.4 Repairing and replacing.17 E.5 Inspections and tests.17 Bibliography.18
follows: a) Wherever possible the GRP tank or vessel shall be stored in the design orientation i.e. vertical tank or vessel shall be stored (supported and anchored) vertically. If it is not possible to store the item in their operational
orientation it may be stored otherwise with special considerations on supporting and anchoring. The use of saddles or supporting timbers with wedges may be necessary. b) The storage area shall be level and free from protrusions or ridges to avoid point loading. The GRP vessel or tank shall be located in an area remote from vehicular traffic or suitably protected from traffic. Consideration shall be given to movements due to wind on the empty item and temporary anchors shall be provided. 4.5 Lifting devices Where the lifting device will make direct contact with GRP surfaces, synthetic fibre flat webbing slings shall be used. The minimum width of the slings shall be 80 mm. 4.6 Loading The GRP tank or vessel shall be lifted and handled in a suitable manner according to the state of the art; appropriate manners are shown in the examples in Annex A (informative) and Annex B (informative). The lifting devices shall be attached to the GRP tank or vessel in correspondence with the design of the tank or
vessel. All lifts shall take into the consideration the site and atmospheric conditions, especially wind. All lifts shall avoid any impact. Loading details shall be recorded.
NOTE This may be done by e.g. using the form given in Annex C (informative). 4.7 Transportation Loads occurring during transport shall be considered to ensure that undue stress, local loads and abrasion are not imposed on the GRP tank or vessel. The GRP tank or vessel shall be secured by webbing slings or ropes. NOTE At the destination and before off-loading the GRP tank or vessel should be visually inspected. The results of inspec-tion should be recorded, e.g. using the form Annex C (informative). SIST EN 13121-4:2005
...
Questions, Comments and Discussion