EN 846-7:2000
(Main)Methods of test for ancillary components for masonry - Part 7: Determination of shear load capacity and load displacement characteristics of shear ties and slip ties (couplet test for mortar joint connections)
Methods of test for ancillary components for masonry - Part 7: Determination of shear load capacity and load displacement characteristics of shear ties and slip ties (couplet test for mortar joint connections)
This European standard specifies the couplet method for determining the horizontal and vertical shear load resistance and load-deflection behaviour of shear ties and slip ties embedded in mortar joints. The test is intended for ties for connecting together two leaves of masonry forming a collar jointed wall or two walls at right angles. It also applies to ties used for connecting the edges of infill panel walls to frames which encircle them.
Prüfverfahren für Ergänzungsbauteile für Mauerwerk - Teil 7: Bestimmung der Schubtragfähigkeit und der Steifigkeit von Mauerverbindern (Steinpaar-Prüfung in Mörtelfugen)
Diese Europäische Norm legt das Steinpaar-Verfahren zur Bestimmung der horizontalen und vertikalen Schubtragfähigkeit und Steifigkeit von in Mörtel- fugen eingebetteten Mauerverbindern fest. Die Prüfung ist vorgesehen für Mauerverbinder, die zwei Mauerwerksschalen einer zweischaligen Mauerwerkswand mit Längsfuge oder zwei rechtwinklig zueinander stehende Wände verbinden. Sie ist auch für Mauerverbinder anwendbar, die zur Verbindung der Ränder von Füllwänden mit Rahmenkonstruktionen verwendet werden.
Méthodes d'essai des composants accessoires de maçonnerie - Partie 7: Détermination de la résistance au cisaillement et des caractéristiques effort-déformation des attaches résistant au cisaillement et des attaches de glissement (essai dans un joint de mortier entre deux éléments)
La présente norme européenne spécifie la méthode d'essai pour la détermination de la résistance au cisaillement horizontal et vertical et du comportement charge/déformation d'attaches de cisaillement et d'attaches de glissement ancrées dans des joints de mortier. Cet essai est conçu pour des attaches prévues pour relier deux parois de maçonnerie ou deux murs à angles droits. Il s'applique également à des attaches utilisées pour relier les bords de murs de remplissage aux cadres ou aux ossatures qui les entourent.
Metode preskušanja dodatnih komponent zidovine - 7. del: Ugotavljanje strižne nosilnosti in lastnosti sila-pomik zidnih veznih stremen, obremenjenih na strig in zdrs (preskus v malti med dvema zidakoma)
General Information
- Status
- Withdrawn
- Publication Date
- 15-Feb-2000
- Withdrawal Date
- 07-Aug-2012
- Technical Committee
- CEN/TC 125 - Masonry
- Drafting Committee
- CEN/TC 125/WG 4 - Test methods
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 08-Aug-2012
- Completion Date
- 08-Aug-2012
- Directive
- 89/106/EEC - Construction products
Relations
- Effective Date
- 13-May-2009
Get Certified
Connect with accredited certification bodies for this standard

ICC Evaluation Service
Nonprofit organization that performs technical evaluations of building products.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
BBA (British Board of Agrément)
UK construction product certification.
Sponsored listings
Frequently Asked Questions
EN 846-7:2000 is a standard published by the European Committee for Standardization (CEN). Its full title is "Methods of test for ancillary components for masonry - Part 7: Determination of shear load capacity and load displacement characteristics of shear ties and slip ties (couplet test for mortar joint connections)". This standard covers: This European standard specifies the couplet method for determining the horizontal and vertical shear load resistance and load-deflection behaviour of shear ties and slip ties embedded in mortar joints. The test is intended for ties for connecting together two leaves of masonry forming a collar jointed wall or two walls at right angles. It also applies to ties used for connecting the edges of infill panel walls to frames which encircle them.
This European standard specifies the couplet method for determining the horizontal and vertical shear load resistance and load-deflection behaviour of shear ties and slip ties embedded in mortar joints. The test is intended for ties for connecting together two leaves of masonry forming a collar jointed wall or two walls at right angles. It also applies to ties used for connecting the edges of infill panel walls to frames which encircle them.
EN 846-7:2000 is classified under the following ICS (International Classification for Standards) categories: 91.060.10 - Walls. Partitions. Facades; 91.080.30 - Masonry. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 846-7:2000 has the following relationships with other standards: It is inter standard links to EN 846-7:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 846-7:2000 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC; Standardization Mandates: M/116. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 846-7:2000 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2001
Metode preskušanja dodatnih komponent zidovine - 7. del: Ugotavljanje strižne
nosilnosti in lastnosti sila-pomik zidnih veznih stremen, obremenjenih na strig in
zdrs (preskus v malti med dvema zidakoma)
Methods of test for ancillary components for masonry - Part 7: Determination of shear
load capacity and load displacement characteristics of shear ties and slip ties (couplet
test for mortar joint connections)
Prüfverfahren für Ergänzungsbauteile für Mauerwerk - Teil 7: Bestimmung der
Schubtragfähigkeit und der Steifigkeit von Mauerverbindern (Steinpaar-Prüfung in
Mörtelfugen)
Méthodes d'essai des composants accessoires de maçonnerie - Partie 7: Détermination
de la résistance au cisaillement et des caractéristiques effort-déformation des attaches
résistant au cisaillement et des attaches de glissement (essai dans un joint de mortier
entre deux éléments)
Ta slovenski standard je istoveten z: EN 846-7:2000
ICS:
91.080.30 Zidane konstrukcije Masonry
2003-01.Slovenski inštitut za stand
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.