This European Standard specifies laboratory methods for testing externally and internally mounted air transfer devices
operating under pressure differences.
It applies to devices located between two spaces (between one room and outside, or between two rooms) of the following
types:
-devices with fixed opening(s);
-devices with manually adjustable opening(s);
-devices with pressure difference controlled opening(s);
-window openings specifically designed to act as an air transfer device.
It describes tests intended to characterise the following:
-flow rate/pressure;
-non-reverse flow ability;
-air tightness when closed' (for closeable externally mounted air transfer device);
-geometrical free area;
-air diffusion in the occupied zone;
-sound insulation;
-water tightness.
This standard does not apply to evaluation of:
-air filtration;
-condensation risk;
-noise production.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies laboratory methods for testing externally and internally mounted air transfer devices operating under pressure differences.
This document applies to air transfer devices of the following types:
- air transfer devices with fixed opening(s);
- air transfer devices with manually adjustable opening(s);
- air transfer devices with pressure difference controlled opening(s);
- window openings specifically designed to act as an air transfer device.
This document describes tests intended to characterize the following:
- flow rate/pressure;
- equivalent area
- reverse flow ability;
- air tightness when closed;
- free area;
- air diffusion in the occupied zone;
- sound insulation;
- water tightness.
This document does not apply to evaluation of:
- air filtration;
- condensation risk;
- noise production.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard defines physical quantities used in the field thermal performance of
buildings and building elements, and gives the corresponding Symbols and units.
NOTE Because the scope of this International Standard is restricted to thermal performance and energy use
in the built environment, some of the definitions given in clause 2 differ from those given ISO 80000-5 Quantities
and units - Part 5: Thermodynamics (ISO 80000-5:2007).
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 7345:2018 defines physical quantities used in the thermal performance of buildings and building elements, and gives the corresponding symbols and units.
NOTE Because the scope of this document is restricted to thermal performance and energy use in the built environment, some of the definitions it contains differ from those given ISO 80000-5.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
This standard specifies a general method for assessing the driving rain resistance of wall systems through determining the water tightness of wall systems under pulsating air pressure.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This standard specifies a general method for assessing the driving rain resistance of wall systems through determining the water tightness of wall systems under pulsating air pressure.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This Standard establishes the principles and criteria to be complied with for the determination of the laboratory steady-state heat transfer properties of masonry walls in a hot box by means of a heat flow meter mounted on one face of the masonry wall to be tested (i.e. the test specimen). It describes the apparatus, measurement technique and necessary data reporting. It does not, however, specify a particular apparatus design since requirements vary particularly in terms of size, and also to a lesser extent in terms of operating conditions.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
This Standard establishes the principles and criteria to be complied with for the determination of the laboratory steady-state heat transfer properties of masonry walls in a hot box by means of a heat flow meter mounted on one face of the masonry wall to be tested (i.e. the test specimen). It describes the apparatus, measurement technique and necessary data reporting. It does not, however, specify a particular apparatus design since requirements vary particularly in terms of size, and also to a lesser extent in terms of operating conditions.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
Migrated from Progress Sheet (TC Comment) (2000-07-10): The final ISO Standard is not yet available ++ In the first registration CEN/TC 89 had 1990-10 as date for stage 41 approved ++ by BT
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
Lays down the principles for the design of the apparatus and minimum requirement that shall be met for determination of the laboratory steady-state thermal transmission properties of building components and similar components for industrial use. Does not specify a particular design. Describes also the apparatus, measurement technique and necessary data reporting. Primarily intended for laboratory measurements of large, inhomogeneous specimens. Does not provide for measurements where there is mass transfer through the specimen during the test.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies laboratory methods for testing externally and internally mounted air transfer devices operating under pressure differences. It applies to any devices located between two spaces (between one room and outside, or between two rooms) such as: - devices with fixed opening(s); - devices with manually adjustable opening(s); - devices with pressure difference controlled opening(s). It describes tests intended to characterize the following: - flowrate/pressure; - air diffusion; - air leakage (for closeable externally mounted air transfer device); - sound reduction;...
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies laboratory methods for testing externally and internally mounted air transfer devices operating under pressure differences. It applies to any devices located between two spaces (between one room and outside, or between two rooms) such as: - devices with fixed opening(s); - devices with manually adjustable opening(s); - devices with pressure difference controlled opening(s). It describes tests intended to characterize the following: - flowrate/pressure; - air diffusion; - air leakage (for closeable externally mounted air transfer device); - sound reduction;...
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
Defines physical quantities used in the field of thermal insulation, i.a. quantity of heat, heat flow rate, density of heat flow rate, thermal conductivity, thermal resistance, thermal transmittance, heat capacity, thermal diffusivity, thermal effusivity etc., and gives the corresponding symbols and units.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
Defines physical quantities used in the field of thermal insulation, i.a. quantity of heat, heat flow rate, density of heat flow rate, thermal conductivity, thermal resistance, thermal transmittance, heat capacity, thermal diffusivity, thermal effusivity etc., and gives the corresponding symbols and units.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day