Controls for heating systems - Part 7: Accompanying TR prEN 12098-3:2015 - Modules M3-5,6,7,8

This Technical Report refers to prEN 12098-3, Controls for heating systems - Part 3: Control equipment for electrical heating systems - Modules M3-5,6,7,8.
It contains information to support the correct understanding, use and national adaption of prEN 12098-3:2015.
This Technical Report does not contain any normative provision.

Begleitender TR zu EN 12098-3

Energijske lastnosti stavb - Naprave za regulacijo sistemov za ogrevanje - 7. del: Razlaga in utemeljitev prEN 12098-3:2015 - Moduli M3-5, 6, 7, 8

To tehnično poročilo se nanaša na standard prEN 12098-3, Nadzor za sisteme ogrevanja – 3. del: Oprema za nadzor sistemov električnega ogrevanja – moduli M3-5,6,7,8.
Vsebuje informacije za podporo pravilnega razumevanja, uporabe in nacionalne prilagoditve standarda prEN 12098-3:2015.
To tehnično poročilo ne vsebuje nobenih normativnih določb.

General Information

Status
Withdrawn
Publication Date
09-Aug-2016
Withdrawal Date
29-Nov-2022
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
30-Nov-2022

Relations

Buy Standard

Technical report
TP CEN/TR 12098-7:2018
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-maj-2018
Energijske lastnosti stavb - Naprave za regulacijo sistemov za ogrevanje - 7. del:
Razlaga in utemeljitev prEN 12098-3:2015 - Moduli M3-5, 6, 7, 8
Controls for heating systems - Part 7: Accompanying TR prEN 12098-3:2015 - Modules
M3-5,6,7,8
Ta slovenski standard je istoveten z: CEN/TR 12098-7:2016
ICS:
91.140.10 Sistemi centralnega Central heating systems
ogrevanja
97.120 Avtomatske krmilne naprave Automatic controls for
za dom household use
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

CEN/TR 12098-7
TECHNICAL REPORT
RAPPORT TECHNIQUE
August 2016
TECHNISCHER BERICHT
ICS 91.140.10; 97.120
English Version
Controls for heating systems - Part 7: Accompanying TR
prEN 12098-3:2015 - Modules M3-5,6,7,8
Begleitender TR zu EN 12098-3
This Technical Report was approved by CEN on 11 April 2016. It has been drawn up by the Technical Committee CEN/TC 247.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TR 12098-7:2016 E
worldwide for CEN national Members.

Contents Page
European foreword . 3
Introduction . 4
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 7
4 Symbols and abbreviations . 7
4.1 Symbols . 7
4.2 Abbreviations . 7
5 Control heating systems, general design rules . 8
5.1 Control heating systems, main design rules, general design rules . 8
5.2 Partitioning control heating zones in buildings . 8
5.3 Generation, distribution, emission control . 8
5.3.1 General . 8
5.3.2 Generation . 8
5.3.3 Distribution . 8
5.3.4 Emission . 9
6 Control heating functions and they impact . 10
6.1 OTC - Outside Temperature Compensated control . 10
6.2 Added functions to OTC control . 11
6.2.1 Auto tuning heating curve parameters . 11
6.2.2 Compensation by emitters energy demand transmission . 11
6.2.3 Other meteorological variables and forecast . 11
6.2.4 OSS - Optimum Start-Stop scheduling . 11
6.2.5 OSS generation impact . 12
6.2.6 OSS distribution impact . 12
6.2.7 OSS emission impact . 13
6.3 Added functions to OSS . 13
6.3.1 Auto tuning OSS parameters . 13
6.3.2 Summer-winter switch . 13
7 Integrated functions in control systems and their impact . 13
7.1 Integrated functions . 13
7.2 Central control effect on room temperature control . 14
7.2.1 General . 14
7.2.2 Heating power control accuracy . 14
7.2.3 Heating curve adaptation . 14
7.2.4 Calculating contribution of central control to emission control. 14
Bibliography . 16

European foreword
This document (CEN/TR 12098-7:2016) has been prepared by Technical Committee CEN/TC 247
“Building Automation, Controls and Building Management”, the secretariat of which is held by SNV.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association.
This document is currently divided into the following parts:
— Controls for heating systems — Part 1: Control equipment for hot water heating systems;
— Controls for heating systems — Part 3: Control equipment for electrical heating systems;
— Controls for heating systems — Part 5: Start-stop schedulers for heating systems;
— Controls for heating systems — Part 6: Accompanying TR prEN 12098-1:2015 Modules M3-5,6,7,8
[Technical Report; currently at Voting stage];
— Controls for heating systems — Part 7: Accompanying TR prEN 12098-3:2015 Modules M3-5,6,7,8
[the present Technical Report; currently at Voting stage];
— Controls for heating systems — Part 8: Accompanying TR prEN 12098-5:2015 Modules M3-5,6,7,8
[Technical Report; currently at Voting stage].
Introduction
The CENSE project, the discussion between CEN and the Concerted action highlighted the high page
count of the entire package due to a lot of “textbook” information. This resulted in flooding and
confusing the normative text.
A huge amount of informative contents shall indeed be recorded and available for users to properly
understand, apply and nationally adapt the EPB standards.
The detailed technical rules CEN/TS 16629 ask for a clear separation between normative and
informative contents:
— to avoid flooding and confusing the actual normative part with informative content;
— to reduce the page count of the actual standard;
— to facilitate understanding of the package.
Therefore each EPB standard shall be accompanied by an informative technical report, like this one,
where all informative content is collected.
Table 1 shows the relative position of this TR within the EPB set of standards.
Table 1 — Relative position of this TR within the EN EPB package of standards
Over-arching Building Technical Building System
(as such)
sub M M M M
M1 M2  M5 M6 M8 M10 M11
1 3 4 7 9
1 General General General
Common
terms and
definitions; Building
2 Needs
symbols, units Energy Needs
and
subscripts
(Free) Indoor Maximu
Conditions m Load
3 Application
without and
Systems Power
Ways to
Ways to Ways to
Express
Express Express
4 Energy
Energy Energy
Perfor
Performance Performance
mance
Building
Heat Transfer Emissio
Functions and
5 by n and x
Building
Transmission control
Boundaries
Building Heat Transfer
Distribu
Occupancy by Infiltration
6 tion and x
and Operating and
control
Conditions Ventilation
Aggregation
of Energy Storage
Internal Heat
7 Services and and x
Gains
Energy control
Carriers
Generat
Building Solar Heat
8 ion and x
Partitioning Gains
control
Calculated
Building Load
9 Energy
Dynamics dispatc
Performance
(thermal hing
Submodule
Descriptions
Descriptions
Descriptions
Heating
Cooling
Ventilation
Humidification
Dehumidification
Domestic Hot
waters
Lighting
Building
automation and
control
PV, wind, .
Over-arching Building Technical Building System
(as such)
sub M M M M
M1 M2  M5 M6 M8 M10 M11
1 3 4 7 9
mass) and
operati
ng
conditio
ns
Measur
Measured Measured ed
10 Energy Energy Energy
Performance Performance Perfor
mance
Inspecti
11 Inspection Inspection
on
Ways to
Express
12  BMS
Indoor
Comfort
External
13 Environment
Conditions
Economic
Calculation
Submodule
Descriptions
Descriptions
Descriptions
Heating
Cooling
Ventilation
Humidification
Dehumidification
Domestic Hot
waters
Lighting
Building
automation and
control
PV, wind, .
1 Scope
This Technical Report refers to prEN 12098-3, Controls for heating systems — Part 3: Control equipment
for electrical heating systems — Modules M3-5,6,7,8.
It contains information to support the correct understanding, use and national adaption of
prEN 12098-3:2015.
This Technical Report does not contain any normative provision.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
prEN 12098-1:2015, Controls for heating systems - Part 1: Control equipment for hot water heating
systems - Modules M3-5,6,7,8
prEN 12098-3:2015, Controls for heating systems - Part 3: Control equipment for electrical heating
systems - Modules M3-5,6,7,8
prEN 15232-1:2015, Energy performance of buildings - Part 1: Impact of Building Automation, Controls
and Building Management - Modules M10-4,5,6,7,8,9,10
EN 15316–2-3:2007, Heating systems in buildings - Method for calculation of system energy requirements
and system efficiencies - Part 2-3: Space heating distribution systems
prEN ISO 52000-1:2015, Energy performance of buildings - Overarching EPB assessment - Part 1: General
framework and procedures (ISO/DIS 52000-1:2015)
EN ISO 7345:1995, Thermal insulation - Physical quantities and definitions (ISO 7345:1987)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN ISO 7345:1995,
prEN ISO 52000-1:2015, prEN 12098-3:2015 (the accompanied EPB standard) apply.
4 Symbols and abbreviations
4.1 Symbols
For the purposes of this document, the symbols given in prEN ISO 52000-1:2015 and
prEN 12098-3:2015 (the accompanied EPB standard) apply.
4.2 Abbreviations
Abbreviation Term
OTC outside temperature compensated
RTC room temperature control
FSS fixed start-stop scheduling
OSS optimum start –stop scheduling
5 Control heating systems, general design rules
5.1 Control heating systems, main design rules, general design rules
Efficient Heating control system consists on integrated functions applie
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.