EN 10351:2011
(Main)Chemical analysis of ferrous materials - Inductively coupled plasma optical emission spectrometric analysis of unalloyed and low alloyed steels - Determination of Mn, P, Cu, Ni, Cr, Mo, V, Co, Al (total) and Sn [Routine method]
Chemical analysis of ferrous materials - Inductively coupled plasma optical emission spectrometric analysis of unalloyed and low alloyed steels - Determination of Mn, P, Cu, Ni, Cr, Mo, V, Co, Al (total) and Sn [Routine method]
This European Standard specifies an inductively coupled plasma optical emission spectrometry routine method for the analysis of unalloyed and low alloyed steels, whose iron content shall be at least 95 %.
This method is applicable to the elements listed in Table 1 within the ranges shown.
Table 1 - Application ranges
(...)
In all cases, the ranges specified can be extended or adapted (after validation) for the determination of other mass fractions, provided that the iron content in the samples under concern is above 95 %.
Other elements may be included. However such elements and their mass fractions should be carefully checked, taking into account the possible interferences, the sensitivity, the resolution and the linearity criteria of each instrument and each wavelength.
Depending also on the sensitivity of each instrument, suitable dilutions of the calibration and the test sample solutions may be necessary.
Moreover, even if the method described is "multi elemental", it is not absolutely necessary to carry out the determination of all the elements of its scope simultaneously: the measurement conditions have to be optimised by each laboratory, depending on the performances of each apparatus available.
NOTE 1 The accuracy of the method is unsatisfactory for phosphorus contents from 0,05 to 0,1 %.
NOTE 2 The trueness of the method couldn't be checked for vanadium contents below 0,05 %.
NOTE 3 The precision of the method is unsatisfactory for aluminium (total) contents below 0,02 %.
Chemische Analyse von Eisenwerkstoffen - Analyse von unlegierten und niedrig legierten Stählen mittels optischer Emissionsspektrometrie mit induktiv gekoppeltem Plasma - Bestimmung von Mn, P, Cu, Ni, Cr, Mo, V, Co, Al (gesamt) und Sn [Routineverfahren]
Diese Europäische Norm legt ein Verfahren der optischen Emissionsspektrometrie mit induktiv gekoppeltem Plasma (ICP-Emissionsspektrometrie) fest, das routinemäßig zur Analyse unlegierter und niedrig legierter Stähle anzuwenden ist, die einen Eisengehalt von mindestens 95 % haben. Das Verfahren ist auf die in Tabelle 1 aufgeführten Elemente innerhalb der angegebenen Bereiche anwendbar.
Alle angegebenen Bereiche können erweitert oder (nach einer Validierung) so angepasst werden, dass auch andere Massenanteile zu bestimmen sind, sofern die zu analysierenden Proben einen Eisenanteil von mehr als 95 % haben. Das Verfahren darf auch dann angewendet, wenn weitere Elemente enthalten sind. Diese Elemente und ihre Massenanteile sollten jedoch unter Berücksichtigung möglicher Störungen, der Empfindlichkeit, der Auflösung und der Linearitätskriterien für jedes ICP-Emissionsspektrometer und für jede Wellenlänge sorgfältig überprüft werden. Entsprechend der Empfindlichkeit des jeweiligen ICP-Emissionsspektrometers kann es notwendig sein, geeignete Verdünnungen der Kalibrier- und der Untersuchungsprobenlösungen anzuwenden. Obwohl das beschriebene Verfahren zur „Mehrelementbestimmung“ angewendet wird, müssen nicht unbedingt alle im Anwendungsbereich angegebenen Elemente gleichzeitig bestimmt werden; die Messbedin-gungen sind in jedem Prüflaboratorium in Abhängigkeit von den Leistungsparametern der verfügbaren Prüfgeräte zu optimieren. ANMERKUNG 1 Für Phosphorgehalte von 0,05 % bis 0,1 % ist die Genauigkeit dieses Verfahren nicht zufrieden stellend. ANMERKUNG 2 Für Vanadiumgehalte unter 0,05 % konnte die Richtigkeit des Verfahrens nicht überprüft werden. ANMERKUNG 3 Für Aluminiumgehalte (Gesamtgehalte) unter 0,02 % ist die Präzision dieses Verfahrens nicht zufrieden stellend.
Analyse chimique des matériaux ferreux - Analyse des aciers non alliés et faiblement alliés par spectrométrie d'émission optique avec source à plasma induit - Détermination de Mn, P, Cu, Ni, Cr, Mo, V, Co, Al (total) et Sn [Méthode de routine]
La présente Norme européenne spécifie une méthode de routine, par spectrométrie d'émission optique avec
source à plasma induit, pour l’analyse des aciers non alliés et faiblement alliés ayant une teneur en fer d’au
moins 95 %.
Cette méthode s’applique aux éléments listés dans le Tableau 1, dans les domaines de teneur indiqués.
Dans tous les cas, les domaines spécifiés peuvent être étendus ou adaptés (après validation) pour la
détermination des autres teneurs, à condition que la teneur en fer des échantillons concernés soit supérieure
à 95 %.
D'autres éléments peuvent être inclus. Il convient toutefois de contrôler, avec la plus grande attention, ces
éléments et leurs teneurs, en tenant compte des interférences éventuelles, de la sensibilité, de la résolution et
des critères de linéarité de chaque instrument et chaque longueur d'onde.
En fonction, également, de la sensibilité de chaque instrument, des dilutions appropriées des solutions
d’étalonnage et des solutions d’échantillon peuvent être nécessaires.
Qui plus est, même si la méthode décrite est « multiélémentaire », il n’est pas absolument nécessaire de
déterminer simultanément tous les éléments de son domaine d’application : les conditions de mesurage
doivent être optimisées par chaque laboratoire, en fonction des performances de chaque appareil disponible.
NOTE 1 L'exactitude de la méthode n’est pas satisfaisante pour les teneurs en phosphore comprises entre 0,05 et
0,1 %.
NOTE 2 La justesse de la méthode n’a pas pu être vérifiée pour les teneurs en vanadium inférieures à 0,05 %.
NOTE 3 La fidélité de la méthode n’est pas satisfaisante pour les teneurs en aluminium (total) inférieures à 0,02 %.
Kemična analiza železovih zlitin - Analiza z direktno spektrometrijo optične emisije z induktivno sklopljeno plazmo nelegiranih in malolegiranih jekel - Določevanje Mn, P, Cu, Ni, Cr, Mo, V, Co, Al (celotni) in Sn [rutinska metoda]
Ta dokument določa rutinsko metodo z emisijsko spektrometrijo z induktivno sklopljeno plazmo za analizo nelegiranih in malolegiranih jekel.
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.@Chemische Analyse von Eisenwerkstoffen - Analyse von unlegierten und niedrig legierten Stählen mittels optischer Emissionsspektrometrie mit induktiv gekoppeltem Plasma - Bestimmung von Mn, P, Cu, Ni, Cr, Mo, V, Co, Al (gesamt) und Sn [Routineverfahren]Analyse chimique des matériaux ferreux - Analyse des aciers non alliés et faiblement alliés par spectrométrie d'émission optique avec source à plasma induit - Détermination de Mn, P, Cu, Ni, Cr, Mo, V, Co, Al (total) et Sn [Méthode de routine]Chemical analysis of ferrous materials - Inductively coupled plasma optical emission spectrometric analysis of unalloyed and low alloyed steels - Determination of Mn, P, Cu, Ni, Cr, Mo, V, Co, Al (total) and Sn [Routine method]77.040.30Kemijska analiza kovinChemical analysis of metalsICS:Ta slovenski standard je istoveten z:EN 10351:2011SIST EN 10351:2011en,fr,de01-november-2011SIST EN 10351:2011SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 10351
March 2011 ICS 77.140.10; 77.140.45 English Version
Chemical analysis of ferrous materials - Inductively coupled plasma optical emission spectrometric analysis of unalloyed and low alloyed steels - Determination of Mn, P, Cu, Ni, Cr, Mo, V, Co, Al (total) and Sn [Routine method]
Analyse chimique des matériaux ferreux - Analyse des aciers non alliés et faiblement alliés par spectrométrie d'émission optique avec source à plasma induit - Détermination de Mn, P, Cu, Ni, Cr, Mo, V, Co, Al (total) et Sn [Méthode de routine]
Chemische Analyse von Eisenwerkstoffen - Analyse von unlegierten und niedrig legierten Stählen mittels optischer Emissionsspektrometrie mit induktiv gekoppeltem Plasma -Bestimmung von Mn, P, Cu, Ni, Cr, Mo, V, Co, Al (gesamt) und Sn [Routineverfahren] This European Standard was approved by CEN on 15 January 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 10351:2011: ESIST EN 10351:2011
Plasma optical emission spectrometer — Suggested performance criteria to be checked . 20Annex B (normative)
Synoptic of the operations related to Clause 9 . 24Annex C (informative)
Test samples used for the validation precision test . 25Annex D (informative)
Detailed results obtained from the validation precision test . 26Annex E (informative)
Graphical representation of the precision data . 35Bibliography . 44 SIST EN 10351:2011
In all cases, the ranges specified can be extended or adapted (after validation) for the determination of other mass fractions, provided that the iron content in the samples under concern is above 95 %. Other elements may be included. However such elements and their mass fractions should be carefully checked, taking into account the possible interferences, the sensitivity, the resolution and the linearity criteria of each instrument and each wavelength. Depending also on the sensitivity of each instrument, suitable dilutions of the calibration and the test sample solutions may be necessary. Moreover, even if the method described is "multi elemental", it is not absolutely necessary to carry out the determination of all the elements of its scope simultaneously: the measurement conditions have to be optimised by each laboratory, depending on the performances of each apparatus available. NOTE 1 The accuracy of the method is unsatisfactory for phosphorus contents from 0,05 to 0,1 %. NOTE 2 The trueness of the method couldn't be checked for vanadium contents below 0,05 %. NOTE 3 The precision of the method is unsatisfactory for aluminium (total) contents below 0,02 %. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. CEN/TR 10345:2008, Guideline for statistical data treatment of inter laboratory tests for validation of analytical methods SIST EN 10351:2011
= 1,19 g/ml) 4.2 Hydrochloric acid, solution 1 + 1 Add 500 ml of hydrochloric acid (4.1) to 500 ml of water. 4.3 Nitric acid, HNO3 (ρρρρ20 = 1,33 g/ml) 4.4 Nitric acid, solution 1 + 1 Add 500 ml of nitric acid (4.3) to 500 ml of water. 4.5 Hydrofluoric acid, HF (ρρρρ20 = 1,13 g/ml) WARNING — Hydrofluoric acid is extremely irritating and corrosive to skin and mucous membranes producing severe skin burns which are slow to heal. In the case of contact with skin, wash well with water, apply a topical gel containing 2,5 % (mass fraction) calcium gluconate, and seek immediate medical treatment. 4.6 Sulphuric acid, H2SO4 (ρρρρ20 = 1,84 g/ml) 4.7 Sulphuric acid, solution 1 + 1 SIST EN 10351:2011
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.