(Main)Aerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short circuit test
Aerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short circuit test
This standard specifies a method for appraising the behaviour of cable insulation subjected to an electric arc initiated by a contaminating fluid.
This standard shall be used together with EN 3475-100.
The primary aim of this test is to produce, in a controlled fashion, failure effects which are representative of those which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination such that electrical arcing occurs, between cables.
Six levels of prospective fault current have been specified for cable sizes 26 to 10.
Individual product standards shall require at least sizes 24, 20, 14 cable to be assessed.
Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 605: Verhalten nach Kurzschluss, feucht
Diese Norm legt ein Verfahren zur Beurteilung des Verhaltens der Isolierung einer Leitung gegenüber einem elek-trischen Lichtbogen fest, der durch eine Verunreinigungsflüssigkeit erzeugt wird.
Diese Norm ist in Verbindung mit EN 3475-100 anzuwenden.
Der Hauptzweck dieser Prüfung besteht darin, auf geregelte Weise Fehlereffekte zu erzeugen, die repräsentativ sind für solche, die im Betrieb auftreten können, wenn ein typisches Leitungsbündel beschädigt und einer Verunreinigung durch eine wässrige Flüssigkeit ausgesetzt wird, so dass zwischen den Leitungen Lichtbogen entstehen.
Sechs prospektive Fehlerstromwerte wurden für die Leitungsgrößen 26 bis 10 festgelegt.
In den einzelnen Produktnormen muss zumindest die Prüfung der Leitungsgrößen 24, 20 und 14 vorgeschrieben werden.
Série aérospatiale - Câbles électriques à usage aéronautique - Méthodes d'essais - Partie 605: Essai de court-circuit humide
Aerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short circuit test
General Information
- Status
- Withdrawn
- Publication Date
- 11-Jun-2002
- Withdrawal Date
- 13-Jul-2010
- Technical Committee
- ASD/ELEC - Electrical
- Drafting Committee
- ASD/ELEC - Electrical
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 14-Jul-2010
- Completion Date
- 14-Jul-2010
Relations
- Effective Date
- 08-Jun-2022
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard

DEKRA North America
DEKRA certification services in North America.
Eagle Registrations Inc.
American certification body for aerospace and defense.

Element Materials Technology
Materials testing and product certification.
Sponsored listings
Frequently Asked Questions
EN 3475-605:2002 is a standard published by the European Committee for Standardization (CEN). Its full title is "Aerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short circuit test". This standard covers: This standard specifies a method for appraising the behaviour of cable insulation subjected to an electric arc initiated by a contaminating fluid. This standard shall be used together with EN 3475-100. The primary aim of this test is to produce, in a controlled fashion, failure effects which are representative of those which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination such that electrical arcing occurs, between cables. Six levels of prospective fault current have been specified for cable sizes 26 to 10. Individual product standards shall require at least sizes 24, 20, 14 cable to be assessed.
This standard specifies a method for appraising the behaviour of cable insulation subjected to an electric arc initiated by a contaminating fluid. This standard shall be used together with EN 3475-100. The primary aim of this test is to produce, in a controlled fashion, failure effects which are representative of those which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination such that electrical arcing occurs, between cables. Six levels of prospective fault current have been specified for cable sizes 26 to 10. Individual product standards shall require at least sizes 24, 20, 14 cable to be assessed.
EN 3475-605:2002 is classified under the following ICS (International Classification for Standards) categories: 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 3475-605:2002 has the following relationships with other standards: It is inter standard links to EN 3475-605:2010, EN 2714-004:2006, EN 4612-010:2019, EN 4604-009:2014, EN 4612-006:2019, EN 2714-008:2006, EN 2713-010:2006, EN 4612-008:2011, EN 4612-008:2019, EN 2084:2018, EN 4612-009:2019, EN 4612-009:2011, EN 4604-010:2017, EN 4612-005:2011, EN 4611-004:2018. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 3475-605:2002 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Aerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short circuit testLuft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 605: Verhalten nach Kurzschluss, feuchtSérie aérospatiale - Câbles électriques a usage aéronautique - Méthodes d'essais - Partie 605: Essai de court-circuit humideAerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short circuit test49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 3475-605:2002SIST EN 3475-605:2004en01-maj-2004SIST EN 3475-605:2004SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 3475-605June 2002ICS 49.060English versionAerospace series - Cables, electrical, aircraft use - Testmethods - Part 605: Wet short circuit testSérie aérospatiale - Câbles électriques à usageaéronautique - Méthodes d'essais - Partie 605: Essai decourt-circuit humideLuft- und Raumfahrt - Elektrischen Leitungen für LuftfahrtVerwendung - Prüfverfahren - Teil 605: Verhalten nachKurzschluß, feuchtThis European Standard was approved by CEN on 21 January 2002.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2002 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 3475-605:2002 ESIST EN 3475-605:2004
1)3Specimen requirementsCables to be tested shall be of traceable origin and shall have passed the high voltage dielectric test definedin the product standard.4Preparation of specimen4.1Cut seven separate lengths of approximately 0,5 m consecutively from one length of cable, andstrip one of the ends of insulation to permit electrical connection. Clean each length of cable with a cleancloth moistened with propan-2-ol fluid.¾¾¾¾¾¾276¾>1)Published by: Department of Defense, The Pentagon, Washington D.C. 20301 USA.SIST EN 3475-605:2004
...