NEXT Action: CCMC to make available
2019-03-06 - Sent to BT for approval of A nnex ZA/ZZ (approved=D162/C075)
2018-12-13 PeC: "Compliant" for LVD
2018-11-20 PeC: sent to BT to keep ratification pending in order to fix harmonization (approved D161/C072)
2018-11-12 PeC: submitted for HAS assessment
2017-11-21 - Negative assessment is received during CDV stage. Consultant assessment request is missing for FDIS.

    • sale 10% off
    • Amendment
      17 pages
      English language
    • e-Library read for
      1 day

NEXT Action: CCMC to make available
2019-01-21 PeC: "Compliant" for LVD, sent to BT for integration (approved=D162/C043)
2018-11-21 PeC: sent to BT to keep ratification pending in order to fix harmonization (approved=D161/C073)
2018-11-12 PeC: submitted for HAS assessment
2017-07-31 - Cannot allocate for publication due to negative assessment from Consultant.

    • sale 10% off
    • Amendment
      5 pages
      English language
    • e-Library read for
      1 day

This document provides criteria for the re-use of sulphur hexafluoride (SF6) and its mixtures after recovery and reclaiming from electrical equipment (e.g. for maintenance, at the end-oflife). Sulphur hexafluoride (SF6), nitrogen (N2) and carbon tetrafluoride (CF4), are gases commonly used for electrical equipment. Taking into account environmental concerns, particular attention is paid to re-use criteria for SF6 and its mixtures with N2 and CF4 for its use in electrical equipment. Procedures fo...view more

    • sale 10% off
    • Standard
      51 pages
      English language
    • e-Library read for
      1 day

IEC 60480:2019 provides criteria for the re-use of sulphur hexafluoride (SF6) and its mixtures after recovery and reclaiming from electrical equipment (e.g. for maintenance, at the end-of-life).
Sulphur hexafluoride (SF6), nitrogen (N2) and carbon tetrafluoride (CF4), are gases commonly used for electrical equipment. Taking into account environmental concerns, particular attention is paid to re-use criteria for SF6 and its mixtures with N2 and CF4 for its use in electrical equipment. Procedures...
view more

    • sale 15% off
    • Standard
      97 pages
      English and French language

IEC 60364-5-53:2019 Deals with general requirements for isolation, switching and control and with the requirements for selection and erection of the devices provided to fulfil such functions. This fourth edition cancels and replaces the third edition published in 2001, Amendment 1:2002 and Amendment 2:2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) revision of all clauses except 531 a...
view more

    • sale 15% off
    • Standard
      152 pages
      English and French language

This part of IEC 61347 specifies particular safety requirements for electronic controlgear for
use on AC supplies up to 1 000 V at 50 Hz or 60 Hz and/or DC supplies with operating
frequencies deviating from the supply frequency, associated with fluorescent induction lamps
as specified in IEC 62532 and IEC 62639, for high-frequency operation.
For emergency lighting operation, particular requirements for controlgear operated from a
central supply are given in Annex J. Performance requirements...
view more

    • sale 10% off
    • Standard
      39 pages
      English language
    • e-Library read for
      1 day

IEC 61800-9-1:2017 specifies the general methodology to energy efficiency standardization for any extended product by using the guidance of the extended product approach (EPA). This document specifies the methodology of determination of losses of the extended product and its sub-parts. It is applicable to motor systems operated by a motor starter or by a converter (power drive systems).

    • sale 10% off
    • Standard
      34 pages
      English language
    • e-Library read for
      1 day

IEC 61800-9-2:2017 specifies energy efficiency indicators of power electronics (complete drive modules, CDM), power drive systems (PDS) and motor starters, all used for motor driven equipment. It specifies the methodology for the determination of losses of the complete drive module (CDM), the power drive system (PDS) and the motor system. It defines IE and IES-classes, their limit values and provides test procedures for the classification of the overall losses of the motor system. Furthermore, t...view more

    • sale 10% off
    • Standard
      112 pages
      English language
    • e-Library read for
      1 day

This part of IEC 61347 specifies particular safety requirements for electronic controlgear for use on d.c. supplies up to 250 V and a.c. supplies up to 1 000 V at 50 Hz or 60 Hz and at an output frequency which can deviate from the supply frequency, associated with LED modules.

    • sale 10% off
    • Amendment
      5 pages
      English language
    • e-Library read for
      1 day

IEC 61347-2-3:2011 specifies particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. This second edition cancels and replaces the first edition published in 2000, its Amendment 1 (2004) and its Amendment 2 (2006), IEC 61347-2-4 publis...view more

    • sale 10% off
    • Amendment
      6 pages
      English language
    • e-Library read for
      1 day

IEC 61800-9-2:2017 specifies energy efficiency indicators of power electronics (complete drive modules, CDM), power drive systems (PDS) and motor starters, all used for motor driven equipment. It specifies the methodology for the determination of losses of the complete drive module (CDM), the power drive system (PDS) and the motor system.
It defines IE and IES-classes, their limit values and provides test procedures for the classification of the overall losses of the motor system.
Furthermore,...
view more

    • sale 15% off
    • Standard
      226 pages
      English and French language

IEC 61800-9-1:2017 specifies the general methodology to energy efficiency standardization for any extended product by using the guidance of the extended product approach (EPA).
This document specifies the methodology of determination of losses of the extended product and its sub-parts. It is applicable to motor systems operated by a motor starter or by a converter (power drive systems).

    • sale 15% off
    • Standard
      61 pages
      English and French language

This part of HD 60364 deals with general requirements for isolation and switching and with the
requirements for selection and erection of the devices provided to fulfil such functions.

    • sale 10% off
    • Standardization document
      16 pages
      English language
    • e-Library read for
      1 day

This part of HD 60364 deals with general requirements for isolation, switching, control and monitoring and with the requirements for selection and erection of the devices provided to fulfil such functions

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day

This International Standard provides general and safety requirements for programmable
components used in products covered by IEC 61347.
The requirements of this standard are only applicable to the programmable components
(including its embedded software) in the electronic lamp controlgear. For other
electric/electronic circuits and their components in the electronic lamp controlgear, the
requirements of IEC 61347 series apply.

    • sale 10% off
    • Standard
      43 pages
      English language
    • e-Library read for
      1 day

This part of IEC 61347 specifies general and safety requirements for lamp controlgear for use
on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz.
This standard also covers lamp controlgear for lamps which are not yet standardized.
Tests dealt with in this standard are type tests. Requirements for testing individual lamp
controlgear during production are not included.
Requirements for semi-luminaires are given in IEC 60598-1:2014 (see definition 1.2.60).
Parti...
view more

    • sale 10% off
    • Standard
      124 pages
      English language
    • e-Library read for
      1 day