Lamp controlgear - Part 2-14: Particular requirements for d.c. and/or a.c. supplied electronic controlgear for fluorescent induction lamps (IEC 61347-2-14:2018)

This part of IEC 61347 specifies particular safety requirements for electronic controlgear for
use on AC supplies up to 1 000 V at 50 Hz or 60 Hz and/or DC supplies with operating
frequencies deviating from the supply frequency, associated with fluorescent induction lamps
as specified in IEC 62532 and IEC 62639, for high-frequency operation.
For emergency lighting operation, particular requirements for controlgear operated from a
central supply are given in Annex J. Performance requirements appropriate to the safe
operation of emergency lighting are also contained in Annex J.
Requirements for emergency lighting controlgear operating from non-centralized power
supplies are given in IEC 61347-2-7.
NOTE Performance requirements detailed in Annex J are those considered to be safety related with respect to
reliable emergency operation.

Geräte für Lampen - Teil 2-14: Besondere Anforderungen an gleich- und/oder wechselstromversorgte elektronische Betriebsgeräte für Induktions-Leuchtstofflampen

Appareillages de lampes - Partie 2-14: Exigences particulières pour les appareillages électroniques alimentés en courant continu et/ou alternatif pour les lampes fluorescentes à induction

L'IEC 61347-2-14:2018 spécifie les exigences particulières de sécurité applicables aux appareillages électroniques destinés à être alimentés en courant alternatif jusqu’à 1 000 V à 50 Hz ou 60 Hz et/ou à courant continu avec des fréquences de fonctionnement différentes de la fréquence du réseau d’alimentation, associés aux lampes fluorescentes à induction spécifiées dans l’IEC 62532 et l’IEC 62639, pour un fonctionnement à haute fréquence.

Krmilne stikalne naprave za sijalke - 2-14. del: Posebne zahteve za enosmerno in/ali izmenično napajane elektronske krmilne stikalne naprave za fluorescenčne indukcijske sijalke (IEC 61347-2-14:2018)

Ta del standarda IEC 61347 določa posebne varnostne zahteve za elektronske krmilne stikalne naprave za uporabo z enosmernim napajanjem do 1000 V pri 50 Hz ali 60 Hz in/ali izmeničnim napajanjem z delovno frekvenco, ki odstopa od napajalne frekvence, v povezavi s fluorescenčnimi indukcijskimi sijalkami, kot so opredeljene v standardih IEC 62532 in IEC 62639, za delovanje pri visokih frekvencah.
Za zasilno razsvetljavo so posebne zahteve za centralno napajane krmilne stikalne naprave so podane v dodatku J. Zahteve glede delovanja za varno delovanje zasilne razsvetljave so prav tako zajete v dodatku J.
Zahteve za necentralno napajane krmilne stikalne naprave za zasilno razsvetljavo so podane v standardu IEC 61347-2-7.
OPOMBA: Zahteve glede delovanja, navedene v dodatku J, so tiste, ki so povezane z varnostjo glede zanesljivega zasilnega delovanja.

General Information

Status
Published
Publication Date
13-May-2018
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
07-May-2018
Due Date
12-Jul-2018
Completion Date
14-May-2018

Relations

Buy Standard

Standard
EN IEC 61347-2-14:2018
English language
39 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN IEC 61347-2-14:2018
01-julij-2018
.UPLOQHVWLNDOQHQDSUDYH]DVLMDONHGHO3RVHEQH]DKWHYH]DHQRVPHUQR
LQDOLL]PHQLþQRQDSDMDQHHOHNWURQVNHNUPLOQHVWLNDOQHQDSUDYH]DIOXRUHVFHQþQH
LQGXNFLMVNHVLMDONH ,(&
Lamp controlgear - Part 2-14: Particular requirements for d.c. and/or a.c. supplied
electronic controlgear for fluorescent induction lamps (IEC 61347-2-14:2018)
Ta slovenski standard je istoveten z: EN IEC 61347-2-14:2018
ICS:
29.130.01 Stikalne in krmilne naprave Switchgear and controlgear
na splošno in general
29.140.99 Drugi standardi v zvezi z Other standards related to
žarnicami lamps
SIST EN IEC 61347-2-14:2018 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN IEC 61347-2-14:2018

---------------------- Page: 2 ----------------------

SIST EN IEC 61347-2-14:2018


EUROPEAN STANDARD EN IEC 61347-2-14

NORME EUROPÉENNE

EUROPÄISCHE NORM
April 2018
ICS 29.140.99

English Version
Lamp controlgear - Part 2-14: Particular requirements for DC
and/or AC supplied electronic controlgear for fluorescent
induction lamps
(IEC 61347-2-14:2018)
Appareillages de lampes - Partie 2-14: Exigences Geräte für Lampen - Teil 2-14: Besondere Anforderungen
particulières pour les appareillages électroniques alimentés an gleich- und/oder wechselstromversorgte elektronische
en courant continu et/ou alternatif pour les lampes Betriebsgeräte für Induktions-Leuchtstofflampen
fluorescentes à induction (IEC 61347-2-14:2018)
(IEC 61347-2-14:2018)
This European Standard was approved by CENELEC on 2018-04-03. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN IEC 61347-2-14:2018 E

---------------------- Page: 3 ----------------------

SIST EN IEC 61347-2-14:2018
EN IEC 61347-2-14:2018 (E)
European foreword
The text of document 34C/1374/FDIS, future edition 1 of IEC 61347-2-14, prepared by IEC/SC 34C:
"Auxiliaries for lamps, of IEC technical committee 34: Lamps and related equipment" was submitted to
the IEC-CENELEC parallel vote and approved by CENELEC as EN IEC 61347-2-14:2018.

The following dates are fixed:
(dop) 2019-01-03
• latest date by which the document has to be
implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2021-04-03
standards conflicting with the
document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.

Endorsement notice
The text of the International Standard IEC 61347-2-14:2018 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:

IEC 60598-2-22 NOTE Harmonized as EN 60598-2-22.
2

---------------------- Page: 4 ----------------------

SIST EN IEC 61347-2-14:2018
EN IEC 61347-2-14:2018 (E)
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.

NOTE 1  Where an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.

NOTE 2  Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.

Publication Year Title EN/HD Year
IEC 60929 2011 AC and/or DC-supplied electronic control EN 60929 2011
gear for tubular fluorescent lamps -
Performance requirements
- -  + AC 2011
IEC 61347-1 2015 Lamp controlgear - Part 1: General and EN 61347-1 2015
safety requirement
+ A1 2017  + A1 2018
IEC 61347-2-7 2011 Lamp controlgear -- Part 2-7: Particular EN 61347-2-7 2012
requirements for battery supplied electronic
controlgear for emergency lighting (self-
contained)
+ A1 2017  - -
IEC 61547 -  Equipment for general lighting purposes - EN 61547 -
EMC immunity requirements
IEC 62532 2011 Fluorescent induction lamps - Safety EN 62532 2011
specifications
IEC 62639 2012 Fluorescent induction lamps - Performance EN 62639 2012
specification


3

---------------------- Page: 5 ----------------------

SIST EN IEC 61347-2-14:2018

---------------------- Page: 6 ----------------------

SIST EN IEC 61347-2-14:2018



IEC 61347-2-14

®


Edition 1.0 2018-02




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE











Lamp controlgear –

Part 2-14: Particular requirements for DC and/or AC supplied electronic

controlgear for fluorescent induction lamps



Appareillages de lampes –

Partie 2-14: Exigences particulières pour les appareillages électroniques


alimentés en courant continu et/ou alternatif pour les lampes fluorescentes à

induction












INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 29.140.99 ISBN 978-2-8322-5448-6



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN IEC 61347-2-14:2018
– 2 – IEC 61347-2-14:2018 © IEC 2018
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 7
4 General requirements . 9
5 General notes on tests . 9
6 Classification . 9
7 Marking . 9
7.1 General . 9
7.2 Mandatory markings . 9
7.3 Information to be provided, if applicable . 10
8 Protection against accidental contact with live parts . 10
9 Terminals . 10
10 Provisions for earthing . 10
11 Moisture resistance and insulation . 10
12 Electric strength . 10
13 Thermal endurance test for windings . 10
14 Fault conditions . 10
15 Protection of associated components. 11
15.1 Maximum peak voltage under normal operation conditions . 11
15.2 Maximum working voltage under normal and abnormal operating conditions . 11
15.3 Compliance . 11
15.4 Insulation of input terminals of controllable electronic controlgear . 11
16 Abnormal conditions . 12
16.1 Abnormal conditions for DC and/or AC supplied electronic controlgear . 12
16.2 Additional abnormal conditions for DC only electronic controlgear . 12
17 Construction . 12
18 Creepage distances and clearances . 12
19 Screws, current-carrying parts and connections . 12
20 Resistance to heat, fire and tracking . 13
21 Resistance to corrosion . 13
Annex A (normative) Test to establish whether a conductive part is a live part which
may cause an electric shock . 14
Annex B (normative) Particular requirements for thermally protected lamp controlgear . 15
Annex C (normative) Particular requirements for electronic lamp controlgear with
means of protection against overheating . 16
Annex D (normative) Requirements for carrying out the heating tests of thermally
protected lamp controlgear . 17
Annex E (normative) Use of constant S other than 4 500 in t tests . 18
w
Annex F (normative) Draught-proof enclosure . 19
Annex G (normative) Explanation of the derivation of the values of pulse voltages . 20
Annex H (normative) Tests. 21

---------------------- Page: 8 ----------------------

SIST EN IEC 61347-2-14:2018
IEC 61347-2-14:2018 © IEC 2018 – 3 –
Annex I (normative) Additional requirements for built-in magnetic ballast with double
or reinforced insulation . 22
Annex J (normative) Particular additional safety requirements for DC and/or AC
supplied electronic controlgear for emergency lighting . 23
J.1 General . 23
J.2 Marking . 23
J.2.1 Mandatory markings . 23
J.2.2 Information to be provided if applicable . 23
J.3 General statement . 23
J.4 Starting conditions . 24
J.5 Operating conditions . 24
J.6 Current . 24
J.7 EMC immunity. 24
J.8 Pulse voltage from central battery systems . 24
J.9 Tests for abnormal conditions . 24
J.10 Temperature cycling test and endurance test . 25
J.11 Functional safety (EBLF) . 25
Annex K (informative) Conformity testing during manufacture . 26
Annex L (normative) Particular additional requirements for controlgear providing SELV . 27
Annex M (informative) Dielectric strength test voltages for controlgear intended for
the use in impulse withstand Category III . 28
Annex N (normative) Requirements for insulation materials used for double or
reinforced insulation . 29
Annex O (normative) Additional requirements for built-in electronic controlgear with
double or reinforced insulation . 30
Annex P (normative) Creepage distances and clearances and distance through
insulation (DTI) for lamp controlgear which are protected against pollution by the use
of coating or potting . 31
Annex Q (informative) Example for U calculation . 32
p
Annex R (informative) Concept of creepage distances and clearances . 33
Annex S (informative) Examples of controlgear insulation coordination . 34
Annex T (informative) Creepage distances and clearances for controlgear with a
higher degree of availability (impulse withstand category III) . 35
Bibliography . 36

Table 1 – Relation between RMS working voltage and maximum peak voltage . 11
Table J.1 – Pulse voltages . 24

---------------------- Page: 9 ----------------------

SIST EN IEC 61347-2-14:2018
– 4 – IEC 61347-2-14:2018 © IEC 2018
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

LAMP CONTROLGEAR –

Part 2-14: Particular requirements for DC and/or AC supplied
electronic controlgear for fluorescent induction lamps

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61347-2-14 has been prepared by subcommittee 34C: Auxiliaries
for lamps, of IEC technical committee 34: Lamps and related equipment.
The text of this International Standard is based on the following documents:
FDIS Report on voting
34C/1374/FDIS 34C/1383/RVD

Full information on the voting for the approval of this International Standard can be found in
the report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 10 ----------------------

SIST EN IEC 61347-2-14:2018
IEC 61347-2-14:2018 © IEC 2018 – 5 –
This document is to be used in conjunction with IEC 61347-1:2015 and
IEC 61347-1:2015/AMD1:2017.
NOTE In this document, the following print types are used:
– Requirements proper: in roman type.
– Test specifications: in italic type.
– Explanatory matter: in smaller roman type.
A list of all parts in the IEC 61347 series, published under the general title Lamp controlgear,
can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

---------------------- Page: 11 ----------------------

SIST EN IEC 61347-2-14:2018
– 6 – IEC 61347-2-14:2018 © IEC 2018
INTRODUCTION
This document specifies requirements for fluorescent induction lamp controlgear. The
formatting of IEC 61347-2 into separately published parts provides for ease of future
amendments and revisions. Additional requirements will be added as and when a need for
them is recognized.
This document, and the parts which make up IEC 61347-2, in referring to any of the clauses
of IEC 61347-1, specify the extent to which such a clause is applicable and the order in which
the tests are to be performed; they also include additional requirements, as necessary. All
parts which make up IEC 61347-2 are intended to be self-contained and, therefore, do not
include references to each other. However, for the case of emergency lighting lamp
controlgear, some cross-referencing has been used.
Where the requirements of any of the clauses of IEC 61347-1 are referred to in this document
by the phrase ”The requirements of clause n of IEC 61347-1 apply”, this phrase is interpreted
as meaning that all requirements of the clause in question of Part 1 apply, except any which
are clearly inapplicable to the specific type of lamp controlgear covered by this particular part
of IEC 61347-2.

---------------------- Page: 12 ----------------------

SIST EN IEC 61347-2-14:2018
IEC 61347-2-14:2018 © IEC 2018 – 7 –
LAMP CONTROLGEAR –

Part 2-14: Particular requirements for DC and/or AC supplied
electronic controlgear for fluorescent induction lamps



1 Scope
This part of IEC 61347 specifies particular safety requirements for electronic controlgear for
use on AC supplies up to 1 000 V at 50 Hz or 60 Hz and/or DC supplies with operating
frequencies deviating from the supply frequency, associated with fluorescent induction lamps
as specified in IEC 62532 and IEC 62639, for high-frequency operation.
For emergency lighting operation, particular requirements for controlgear operated from a
central supply are given in Annex J. Performance requirements appropriate to the safe
operation of emergency lighting are also contained in Annex J.
Requirements for emergency lighting controlgear operating from non-centralized power
supplies are given in IEC 61347-2-7.
NOTE Performance requirements detailed in Annex J are those considered to be safety related with respect to
reliable emergency operation.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their
content constitutes requirements of this document. For dated references, only the edition
cited applies. For undated references, the latest edition of the referenced document (including
any amendments) applies.
IEC 60929:2011, AC and/or DC-supplied electronic control gear for tubular fluorescent lamps
– Performance requirements
IEC 61347-1:2015, Lamp controlgear – Part 1: General and safety requirements
IEC 61347-1:2015/AMD1:2017
IEC 61347-2-7:2011, Lamp controlgear – Part 2-7: Particular requirements for battery
supplied electronic controlgear for emergency lighting (self-contained)
IEC 61347-2-7:2011/AMD1:2017
IEC 61547, Equipment for general lighting purposes – EMC immunity requirements
IEC 62532:2011, Fluorescent induction lamps – Safety specifications
IEC 62639:2012, Fluorescent induction lamps – Performance specification
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 61347-1, IEC 62532
and IEC 62639 and the following apply.

---------------------- Page: 13 ----------------------

SIST EN IEC 61347-2-14:2018
– 8 – IEC 61347-2-14:2018 © IEC 2018
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
DC and/or AC supplied electronic controlgear
mains/battery-supplied DC only, AC/DC or AC only to AC invertor including stabilizing
elements for starting and operating one or more fluorescent induction lamps, generally at high
frequency
3.2
maximum allowed peak voltage
highest permitted peak voltage across any insulation under open-circuit condition and any
normal and abnormal operating conditions
Note 1 to entry: The maximum peak voltage is related to the declared RMS working voltage (see Table 1).
3.3
emergency lighting
lighting provided for use when the supply to the normal lighting fails
Note 1 to entry: Emergency lighting includes escape lighting and standby lighting.
3.4
rated battery voltage
voltage declared by the battery manufacturer
3.5
rated emergency power supply voltage
rated voltage of the emergency power supply claimed by the manufacturer
3.6
starting aid
device which facilitates the starting of the lamp
Note 1 to entry: A conductive strip affixed to the outer surface of the lamp and a conductive plate which is spaced
within an appropriate distance from a lamp are examples of starting aids.
3.7
ballast lumen factor
ratio of the luminous flux of a reference lamp when the controlgear under test is operated at
its rated voltage and frequency compared with the luminous flux of the same lamp operated
with the appropriate reference ballast supplied at its rated voltage and frequency
3.8
emergency ballast lumen factor
EBLF
ratio of the emergency luminous flux of the lamp supplied by the emergency controlgear to the
luminous flux of the same lamp operated with the appropriate reference ballast at its rated
voltage and frequency
Note 1 to entry: This note only applies to the French language.
3.9
total circuit power
total power dissipated by ballast and lamp in combination, at the rated voltage and frequency
of the ballast

---------------------- Page: 14 ----------------------

SIST EN IEC 61347-2-14:2018
IEC 61347-2-14:2018 © IEC 2018 – 9 –
3.10
reference lamp
lamp selected for testing controlgear which, when associated with a reference ballast, has
electrical characteristics which are close to the rated values as stated in the relevant lamp
standard
Note 1 to entry Relevant starting lamp data sheets are contained in IEC 62639.
[SOURCE: IEC 61347-1:2015, 3.3, modified – "ballasts" has been replaced with "controlgear"
and the note has been added.]
4 General requirements
The requirements of IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017, Clause 4 apply,
together with the following additional requirement:
DC and/or AC supplied electronic controlgear for emergency lighting shall comply with the
requirements of Annex J.
5 General notes on tests
The requirements of IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017, Clause 5 apply
together with the following additional requirement with regard to the number of specimens.
The following number of specimens shall be submitted for testing:
– one unit for the tests of Clauses 6 to 12 and 15 to 21;
– one unit for the test of Clause 14 (additional units or components, where necessary, may
be required in consultation with the manufacturer).
Tests to meet the safety requirements for DC and/or AC supplied electronic controlgear for
emergency lighting are made under the conditions specified in Annex J.
6 Classification
The requirements of IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017, Clause 6 apply.
7 Marking
7.1 General
Controlgear which forms an integral part of the luminaire need not be marked.
7.2 Mandatory markings
In accordance with the requirements of IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017,
7.2, controlgear, other than integral controlgear, shall be clearly and durably marked with the
following mandatory markings:
a) items a), b), c), d), e), k) and l) of IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017,
7.1, together with
b) the symbol for earthing, as applicable;
c) for controllable controlgear, the control terminals shall be identified;
d) a declaration of the maximum working voltage (RMS) according to 15.3 between
– output terminals,
– any output terminal and earth.

---------------------- Page: 15 ----------------------

SIST EN IEC 61347-2-14:2018
– 10 – IEC 61347-2-14:2018 © IEC 2018
...

Questions, Comments and Discussion