WG 7 - TC 46/SC 46C/WG 7
TC 46/SC 46C/WG 7
General Information
IEC 61156-13:2023 describes cables intended to be used for transmission of 10 Mbit/s over a single twisted pair and distances of up to 1 km. The transmission characteristics of these cables are specified up to a frequency of 20 MHz and at a temperature of 20 °C. Depending on the MICE environment and the installation conditions, either unscreened or screened cables can be used. Furthermore, to consider different maximum transmission lengths, two sets of requirements are specified. The cable type A-1000 is a design supporting up to 1 km channel length while the cable type A-400 is supporting up to 400 m channel length. A blank detail specification can be found in Annex A.
The cables covered by this document are intended to operate with voltages and currents normally encountered in communication systems. While these cables are not intended to be used in conjunction with low impedance sources, for example the electric power supplies of public utility mains, they are intended to be used to support the delivery of DC low voltage remote powering applications.
- Standard24 pagesEnglish languagesale 15% off
IEC 61156-11:2023 is available as IEC 61156-11:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61156-11:2023 describes cables intended to be used for single balanced pair (office, home, industrial) applications according to ISO/IEC 11801-1. An example of existing application is 1000BASE-T1, see ISO/IEC TR 11801-9906. The transmission characteristics of these cables are specified up to a frequency of 1,25 GHz and at a temperature of 20 °C. The T1-C type cable is specified up to 600 MHz, the T1-D type cable up to 1,25 GHz. Depending on the MICE environment and the installation conditions either unscreened or screened cables can be used. A blank detail specification can be found in Annex A.
- Standard27 pagesEnglish languagesale 15% off
IEC 61156-1:2023 is available as IEC 61156-1:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61156-1:2023 specifies the definitions, requirements and test methods of multicore, symmetrical pair and quad cables. This document is applicable to communication systems such as local area networks (LANs) and data communication cables. It is also applicable to cables used for industrial applications, customer premises wiring and generic cabling comprising installation cables and cables for work area wiring which are defined in ISO/IEC 11801 (all parts). The cables covered by this document are intended to operate with voltages and currents normally encountered in communication systems. While these cables are not intended to be used in conjunction with low impedance sources, for example the electric power supplies of public utility mains, they are intended to be used to support the delivery of low voltage remote powering applications including but not restricted to Power over Ethernet as specified in ISO/IEC/IEEE 8802-3.
- Standard111 pagesEnglish and French languagesale 15% off
IEC 61156-8:2023 is available as IEC 61156-8:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61156-8:2023 relates to IEC 61156-1 and IEC 61156-7. The cables described herein are specified up to 1 200 MHz and are specifically designed to build work area cords. It covers a cable having four individually screened (S/FTP) pairs. The cable can be provided with a common screen over the cable core. The cables covered by this sectional specification are intended to operate with voltages and currents normally encountered in communication systems and support the delivery of DC low voltage remote powering applications. These cables are not intended to be used in conjunction with low impedance sources, for example the electric power supply of public utility mains. This second edition cancels and replaces the first edition published in 2009, and Amendment 1:2013. This edition includes the following significant technical changes with respect to the previous edition:
a. align clauses with IEC 61156-1:2023;
b. additional reference to IEC 62153-4-9 test method (triaxial) for coupling attenuation measurement to be consistent with all other parts of the IEC 61156 series;
c. incorporation of blank detail specification.
- Standard26 pagesEnglish languagesale 15% off
IEC 61156-7:2023 is available as IEC 61156-7:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61156-7:2023 specifies cables that can be used for various communication systems as well as for analogue systems, such as video, that exist or are under development and which may use as many as four pairs simultaneously. In this sense, this sectional specification provides the cable characteristics required by system developers to evaluate new systems as well as to enhance present systems. It covers a cable having four individually screened (S/FTP) pairs. The cable can be provided with a common screen over the cable core. This second edition cancels and replaces the first edition published in 2003 and Amendment 1:2012. This edition includes the following significant technical changes with respect to the previous edition:
a. align clauses with IEC 61156-1:2023;
b. remove the clause related to screening attenuation as it is no longer a test to be performed (replaced by coupling attenuation);
c. replace the IEC 62153-4-2 method (injection clamp) with IEC 61156-4-5 (absorbing clamp) for coupling attenuation measurement to be consistent with all other parts of the IEC 61156 series;
d. include IEC 62153-4-9 test method (triaxial) for coupling attenuation measurement to be consistent with all other parts of the IEC 61156 series;
e. incorporate the blank detail specification.
- Standard54 pagesEnglish languagesale 15% off
IEC 61156-12:2021 describes cables intended to be used for transmission of 1 Gbit/s over a single twisted pair for office, home and industrial application. An example of an existing application is 1000BASE-T1; see ISO/IEC TR 11801-9906. The transmission characteristics of these cables are specified up to a frequency of 600 MHz and at a temperature of 20 °C. The cable type recognised is intended to be used for the work area wiring of shielded channels with a nominal length of 40 m. Possible designs are U/FTP, X/UTP and X/FTP, where X stands for F, S or SF.
The cables covered by this document are intended to operate with voltages and currents normally encountered in communication systems. While these cables are not intended to be used in conjunction with low impedance sources, e.g. the electric power supplies of public utility mains, they are intended to be used to support the delivery of low voltage remote powering applications.
- Standard25 pagesEnglish languagesale 15% off
IEC 61156-5:2020 is available as IEC 61156-5:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61156-5:2020 describes the cables intended primarily for horizontal floor wiring as defined in ISO/IEC 11801. It covers cable designs comprising individually screened, common screened and unscreened pairs or quads. The transmission characteristics and the frequency range of the cables are specified at 20 °C. The cables covered by this document are intended to operate with voltages and currents normally encountered in communication systems Those cables are intended to be used to support the delivery of low voltage remote powering applications such as IEEE 802.3af (Power over Ethernet) or further developments for example according to IEEE 802.3at or IEEE 802.3bt. This third edition cancels and replaces the second edition published in 2009 and Amendment 1:2012. This edition includes the following significant technical changes with respect to the previous edition
- additional balance levels with respect to MICE implementation by certain cabling specifications;
- reference to current standards and technical reports with respect to measurement techniques and remote powering.
- Standard27 pagesEnglish languagesale 15% off
IEC 61156-6:2020 is available as IEC 61156-6:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61156-6:2020 describes the cables intended primarily for working area wiring as defined in ISO/IEC 11801 (all parts). It covers cable designs comprising individually screened, common screened and unscreened pairs or quads. The transmission characteristics and the frequency range of the cables are specified at 20 °C. These cables can be used for various communication channels which use as many as four pairs simultaneously. In this sense, this document provides the cable characteristics required by system developers to evaluate new systems. This fourth edition cancels and replaces the third edition published in 2010 and Amendment 1:2012. It includes the following significant technical changes with respect to the previous edition:
- additional balance levels with respect to MICE implementation by certain cabling specifications;
- reference to current standards and technical reports with respect to measurement techniques and remote powering
- Standard26 pagesEnglish languagesale 15% off
IEC 61156-11:2019 describes cables intended to be used for transmission of 1 Gbps over a single twisted pair for office, home and industrial application. An example of existing application is 1000BASE-T1, see ISO/IEC TR 11801-9906. The transmission characteristics of these cables are specified up to a frequency of 600 MHz and at a temperature of 20 °C. The cable type recognised is intended to be used for shielded channels with a nominal length of 40 m. Possible designs are U/FTP, X/UTP and X/FTP, where X stands for F, S or SF. A blank detail specification can be found in Annex A. These cables can comprise more than one pair in the event that several systems are operated in parallel. In this case, refer to Clause 7 of this document. The cables covered by this document are intended to operate with voltages and currents normally encountered in communication systems. While these cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains, they are intended to be used to support the delivery of low-voltage remote powering applications.
- Standard25 pagesEnglish languagesale 15% off
IEC 61156-1-4:2018 specifies a method to assess the thermal behaviour of cables arranged in bundles, for digital communications. A method is described to determine the temperature increase in cable bundles for certain remote powering currents as a basis to analyse the expected performance under several test arrangements described in standards dealing with the installation of cabling systems.
It is only intended to provide guidance to assess the thermal behaviour of cables for digital communications in reference environmental conditions and arrangements. It is therefore not intended to become a type of test method.
This first edition cancels and replaces IEC PAS 61156-1-4, published in 2010. This edition includes the following significant technical changes with respect to the previous edition:
a) Several test arrangements are considered;
b) The mathematical approach was revised.
- Standard18 pagesEnglish languagesale 15% off
IEC 61156-10:2016(E) describes cables primarily intended for work area cords as defined in ISO/IEC 11801 and in ISO/IEC TR 11801-9901 which is planned to be included in the next edition of ISO/IEC 11801-1. It covers overall screened cables with screened (X/FTP) or unscreened (X/UTP) pairs, where X stands for F, S or SF, as well as pair-screened cables without overall screen (U/FTP). The transmission characteristics of these cables are specified up to a frequency of 2 000 MHz and at a temperature of 20 °C. Two categories of cables are recognised:
- Category 8.1 for use in Class I according to ISO/IEC TR 11801-9901;
- Category 8.2 for use in Class II according to ISO/IEC TR 11801-9901.
- Standard17 pagesEnglish languagesale 15% off
IEC 61156-9:2016(E) describes cables primarily intended for the fixed part of channels as defined in ISO/IEC 11801 and in ISO/IEC TR 11801-9901 which is planned to be included in the next edition of ISO/IEC 11801-1. It covers overall screened cables with screened (X/FTP) or unscreened (X/UTP) pairs, where X stands for F, S or SF, as well as pair-screened cables without overall screen (U/FTP). The transmission characteristics of these cables are specified up to a frequency of 2 000 MHz and at a temperature of 20 °C. Two categories of cables are recognised:
- Category 8.1 for use in Class I according to ISO/IEC TR 11801-9901;
- Category 8.2 for use in Class II according to ISO/IEC TR 11801-9901.
- Standard17 pagesEnglish languagesale 15% off
IEC/TR 61156-1-2:2009(E) is a revision of the symmetrical pair/quad electrical transmission characteristics present in IEC 61156-1:2002 (Edition 2) and not carried into IEC 61156-1:2007 (Edition 3). This technical report includes the following topics from IEC 61156-1:2002
- the characteristic impedance test methods and function fitting procedures of 3.3.6;
- Annex A covering basic transmission line equations and test methods;
- Annex B covering the open/short-circuit method;
- Annex C covering unbalance attenuation.
- Technical report46 pagesEnglish languagesale 15% off
IEC 61156-2-1:2010(E) is a blank detail specification. It relates to multicore and symmetrical pair/quad cables for digital communications in horizontal floor wiring. This third edition cancels and replaces the second edition published in 2003. It constitutes a technical revision and takes into account the technical changes made in the IEC 61156-2, Edition 3 (2010).
- Standard12 pagesEnglish languagesale 15% off
IEC 61156-2:2010(E) defines individually screened or unscreened pair/quad cables, with or without overall common screen for horizontal floor wiring. These cables are suitable for the various communication systems for which the reference is given in the relevant detail specification. The cables covered by this sectional specification are intended to operate with voltages and currents normally adopted for communication systems. These cables should not be connected to low impedance sources, for example, the public mains electricity supply. This third edition cancels and replaces the second edition published in 2003 and constitutes a technical revision. This new edition includes category 3 and 5 cables.
This publication is to be read in conjunction with IEC 61156-1:2002.
- Standard16 pagesEnglish languagesale 15% off
IEC 61156-6:2010(E) referes to IEC 61156-1. The cables described herein are intended primarily for work area wiring as defined in ISO/IEC 11801 and ISO/IEC 24702. It covers individually screened, common screened and unscreened pairs or quads. The transmission characteristics and the frequency range of the cables are specified at 20 °C. These cables can be used for various communication channels which use as many as four pairs simultaneously. In this sense, this sectional specification provides the cable characteristics required by system developers to evaluate new systems. It cancels and replaces the second edition published in 2007 and constitutes a technical revision. It includes the following significant technical changes with respect to the previous edition:
- new requirements for new cables Cat6A, Cat7A;
- revised requirements and tests for the cables.
This publication shall be read in conjunction with IEC 61156-1:2009.
- Standard20 pagesEnglish languagesale 15% off
- Standard17 pagesEnglish and French languagesale 15% off
IEC 61156-8:2009(E) relates to IEC 61156-1 and IEC 61156-7. The cables described herein are specified up to 1 200 MHz and are specifically designed to build patch, equipment, and work area cables as defined in ISO/IEC 11801 and ISO/IEC 15018. It covers a cable having four individually screened (STP) pairs. The cable may be provided with a common screen over the cable core. The transmission characteristics are specified for a frequency range 4 MHz to 1 200 MHz and at 20 °C. The contents of the corrigendum of July 2009 have been included in this copy.
- Standard17 pagesEnglish languagesale 15% off
IEC 61156-3-1:2009(E) determines the layout and style for detail specifications describing multicore and symmetrical pair(s)/quad(s) cables for digital communication in work area wiring. Detail specifications based on the blank detail specification may be prepared by a national standards organization, a manufacturer or a user. This edition constitutes a technical revision. The significant global technical change is the alignment with IEC 61156-3:2008. This publication is to be read in conjunction with IEC 61156-1:2002 and IEC 61156-3:2008.
- Standard11 pagesEnglish languagesale 15% off
IEC 61156-4:2009(E) is a sectional specification and relates to IEC 61156-1:2002. The cables are specifically intended for riser wiring up to category 5 (class D) as defined and specified in ISO/IEC 11801:1995. It defines individually screened or unscreened pairs/quads cables, with or without overall common screen. When installed vertically extra length requirements may be applicable and are defined in the relevant specifications. This edition constitutes a technical revision. The main changes can be found in subclauses 3.3.1.2, 3.3.2, 3.3.4, 3.3.5, 3.3.5.1, 3.3.5.2, 3.3.6 and 3.4. This publication is to be read in conjunction with IEC 61156-1:2002.
- Standard15 pagesEnglish languagesale 15% off
IEC 61156-4-1:2009(E) relates to multicore and symmetrical pair/quad cables for digital communications in riser application. This blank detail specification determines the layout and style for detail specifications describing multicore and symmetrical pair(s)/quad(s) cables for digital communication in riser wiring. Detail specifications based on the blank detail specification may be prepared by a national standards organization, a manufacturer or a user. This edition constitutes a technical revision. The significant global technical change is the alignment with IEC 61156-4. This publication is to be read in conjunction with IEC 61156-1:2002 and IEC 61156-4:2009.
- Standard12 pagesEnglish languagesale 15% off
IEC 61156-5:2009(E) describes the cables intended primarily for horizontal floor wiring as defined in ISO/IEC 11801. It covers individually screened, common screened and unscreened pairs or quads. The transmission characteristics and the frequency range of the cables are specified at 20 °C. Those cables are intended to be used to support the delivery of low voltage and power applications such as IEEE 802.3af (Power over Ethernet) and IEEE 802.3at (Power over Ethernet Plus). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- new requirements for new Cat6A and Cat7A cables;
- revised requirements and tests for Cat5e, Cat6 and Cat7 cables. The contents of the corrigendum of February 2010 have been included in this copy. This publication is to be read in conjunction with IEC 61156-1:2002.
- Standard24 pagesEnglish languagesale 15% off
IEC 61156-3:2008(E) defines individually screened, common overall core screen and unscreened pairs or quads in cables for work area wiring. These cables are suitable for the various communication systems for which the reference is given in the relevant detail specification. The cables covered by this sectional specification are intended to operate with voltages and currents normally adopted for communication systems. These cables should not be connected to low impedance sources, for example, the public mains electricity supply. The cables are specifically intended for work area wiring as defined in ISO/IEC 11801. This third edition cancels and replaces the second edition published in 2003. This edition constitutes a technical revision and includes the following significant technical changes with respect to the previous edition:
a) new requirements for new cables Cat3, and Cat5 applications;
b) a better numbering in order to take into account the generic specification.
- Standard14 pagesEnglish languagesale 15% off
IEC 61156-1 is applicable to communication systems such as ISDN, local area networks and data communication systems and specifies the definitions, requirements and test methods of multicore, symmetrical pair and quad cables. It is also applicable to cables used for customer premises wiring. The contents of the corrigendum of August 2015 have been included in this copy.
- Standard96 pagesEnglish and French languagesale 15% off
determines the layout and style for detail specifications describing symmetrical pair cables with transmission characteristics up to 1 200 MHz for digital and analog communications. Detail specifications, based on the blank detail specification, may be prepared by a national organization, a manufacturer, or a user.
- Standard17 pagesEnglish and French languagesale 15% off
applies to capability approval requirements for cables for various communication systems as well as to analog systems, such as video, that exist or are under development and which may use as many as four pairs simultaneously.
- Standard17 pagesEnglish and French languagesale 15% off
provides the cable characteristics required by system developers to evaluate new systems as well as to enhance present systems
- Standard27 pagesEnglish and French languagesale 15% off
specifies the definitions and test methods, when used in harsh environment, of symmetrical pair and quad cables used in digital communication systems such as ISDN, local area networks and data communication systems. gives guidance concerning the design and testing of these cables.
- Standard107 pagesEnglish and French languagesale 15% off
Applies to Capability Approval requirements for cables intended to construct patch, equipment, and work area cords for digital communications in accordance with generic specification IEC 61156-1-1 and Clause 4 of the sectional specification IEC 61156-6.
- Standard8 pagesEnglish languagesale 15% off
Applies to Capability Approval requirements for cables for digital communications in horizontal floor wiring in accordance with generic specification IEC 61156-1-1 and Clause 4 of the sectional specification IEC 61156-5.
- Standard8 pagesEnglish languagesale 15% off
A sectional specification applies to Capability Approval requirements for cables for digital communications in horizontal floor wiring according to IEC 61156-1 and IEC 61156-2.
- Standard15 pagesEnglish and French languagesale 15% off
A sectional specification applies to Capability Approval requirements for cables for digital communications in work area wiring according to IEC 61156-1 and IEC 61156-3.
- Standard15 pagesEnglish and French languagesale 15% off
A sectional specification applies to Capability Approval requirements for multicore and symmetrical pair cables for digital communication riser cables according to IEC 61156-1 and 61156-4.
- Standard15 pagesEnglish and French languagesale 15% off
IEC 61156-5-1:2009(E) describes symmetrical pair/quad cables intended primarily for horizontal floor cabling as defined in ISO/IEC 11801 and ISO/IEC 24702. It includes additional recommended environmental characteristics and severities which are derived from the environmental classifications that are specified for cabling for various environments. This edition constitutes a technical revision and includes the following significant technical changes with respect to the previous edition:
- new requirements for new cables Cat6A and Cat7A;
- revised requirements and tests for the cables.
This publication is to be read in conjunction with IEC 61156-1:2007 and IEC 61156-5:2009.
- Standard10 pagesEnglish languagesale 15% off
IEC 61156-6-1:2009(E) describes symmetrical pair/quad cables intended primarily for horizontal floor cabling as defined in ISO/IEC 11801 and ISO/IEC 24702. It includes additional recommended environmental characteristics and severities which are derived from the environmental classifications that are specified for cabling for various environments. This edition constitutes a technical revision and includes the following significant technical changes with respect to the previous edition:
- new requirements for new cables Cat6A and Cat7A;
- revised requirements and tests for the cables.
This publication is to be read in conjunction with IEC 61156-1:2007 and IEC 61156-6:2007.
- Standard10 pagesEnglish languagesale 15% off
IEC/PAS 61156-1-4:2010(E) is covering exclusively four-pair data grade cables and is intended to provide a test method for the determination of the maximum attained conductor temperatures which occur due to the deployment of the IEEE protocol for PoE /PoEP. It gives as well the required background information about the thermodynamic behaviour of such bundled cables, if they are located in areas with restricted heat dissipation, a reality which occurs in every installation situation. However, only the basic principles are given, as the rigorous application and solution of these problems fall into the relevant cabling standards.