CEN/TC 169/WG 12 - Joint Working Group with CEN/TC 226 - Road lighting
This working group specifies lighting requirements for all classes of roads and road users which meet the needs of visual performance, comfort and safety. It gives lighting values in terms of luminance, illuminance, uniformity, glare restrictions and the colour properties of the light sources to design and control road lighting installations and methods to calculate and measure these values. The working group also provides details on how to measure and control the energy efficiency of road lighting installations. This working group does not consider or set lighting specifications for the lighting of tunnels and underpasses on or under roads.
Joint Working Group with CEN/TC 226 - Road lighting
This working group specifies lighting requirements for all classes of roads and road users which meet the needs of visual performance, comfort and safety. It gives lighting values in terms of luminance, illuminance, uniformity, glare restrictions and the colour properties of the light sources to design and control road lighting installations and methods to calculate and measure these values. The working group also provides details on how to measure and control the energy efficiency of road lighting installations. This working group does not consider or set lighting specifications for the lighting of tunnels and underpasses on or under roads.
General Information
This document defines the presentation of utilances or utilization factors respectively for luminaires used for road lighting.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This part of the European Standard defines how to calculate the energy performance indicators for road lighting installations using the calculated power density indicator (PDI) DP and the calculated annual energy consumption indicator (AECI) DE. Power density indicator (DP) demonstrates the energy needed for a road lighting installation, while it is fulfilling the relevant lighting requirements specified in EN 13201-2. The annual energy consumption indicator (DE) determines the power consumption during the year, even if the relevant lighting requirements change during the night or seasons.
These indicators may be used to compare the energy performance of different road lighting solutions and technologies for the same road lighting project. The energy performance of road lighting systems with different road geometries or different lighting requirements cannot be compared to each other directly, as the energy performance is influenced by, amongst others, the geometry of the area to be lit, as well as the lighting requirements. The power density indicator (DP) and annual energy consumption indicator (DE) apply for all traffic areas covered by the series of lighting classes M, C and P as defined in EN 13201-2.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation28 pagesSlovenian languagesale 10% offe-Library read for1 day
This European Standard specifies measurement conditions and procedures for measuring the photometric quality parameters of road lighting installations, i.e. the quantities that quantify their performances in accordance with EN 13201-2 lighting classes.
Parameters used for quantifying the energy performance of road lighting installations are not considered.
A methodology to evaluate the road lighting performances considering tolerances in the design parameters is described in the informative Annex A.
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation47 pagesSlovenian languagesale 10% offe-Library read for1 day
This European Standard specifies the conventions and mathematical procedures to be adopted in calculating the photometric performance of road lighting installations designed in accordance with the parameters described in EN 13201-2 to ensure that every lighting calculation is based on the same mathematical principles.
The design procedure of a lighting installation also requires the knowledge of the parameters involved in the described model, their tolerances and variability. These aspects are not considered in this part of EN 13201 but a procedure to analyse their contribution in the expected results is suggested in EN 13201-4 and it can also be used in the design phase.
- Standard63 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation57 pagesSlovenian languagesale 10% offe-Library read for1 day
This part of this European Standard defines performance requirements which are specified as lighting classes for road lighting aiming at the visual needs of road users, and it considers environmental aspects of road lighting.
NOTE Installed luminous intensity classes for the restriction of disability glare and control of obtrusive light and installed glare index classes for the restriction of discomfort glare are defined in the informative Annex A. Lighting of pedestrian crossings is discussed in the informative Annex B. Disability glare evaluation for conflict areas (C classes) and pedestrian and pedal cyclists (P classes) is discussed in the informative Annex C.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation21 pagesSlovenian languagesale 10% offe-Library read for1 day
This Technical Report specifies the lighting classes set out in EN 13201-2 and gives guidelines on the selection of the most appropriate class for a given situation. To do this, it includes a system to define appropriate lighting classes for different outdoor public areas in terms of parameters relevant to guarantee the aims presented in introductions.
The decision on whether a road should be lit is defined in the national road lighting policy. This varies by country or municipality. Specific guidelines are usually available at national level for each country. This Technical Report does not give the criteria on which a decision to light an area can be made, nor on how a lighting installation should be used. Further guidance is given in CIE 115:2010 (Paragraph 1.2 and Annex A).
The methods presented in Clauses 5, 6 and 7 have to be considered as the starting points of a comprehensive approach for the normal road lighting. In that sense, the models cannot cover all the different road cases; they introduce general parameters and the impact on lighting requirements. Only the real situation and its unique characteristics (geometry of the road, marking, visual environment, difficulty of the navigation task, lack of visibility, risks of glares due to existing elements, local weather, specific users such as high rate of elderly or visually impaired people, etc.) can lead to a final determination of the appropriate lighting class applying risk evaluation techniques.
The visual needs of road users under reduced traffic volumes during certain periods of night or under varying weather conditions, and the positive benefits of reduced energy consumption and potential environmental improvements, are some of the considerations which justify the installation of adaptive road lighting. There are a variety of suitable instruments, devices and methods which can be used for the intelligent control of a road lighting installation. The control systems range from very simple to the most sophisticated applications. Annex B is of assistance in choosing the correct lighting level when adaptive lighting is used as it provides a more refined evaluation of the luminance or illuminance levels within the specific lighting class. Whilst the luminance or illuminance levels may be varied to suit reduced traffic volumes, weather conditions or other parameters the quality parameters of the applicable lighting class specified in EN 13201-2 should be maintained at all times.
Renewal or refurbishment of obsolete and uneconomic installations is important. It may be possible to obtain more adapted lighting levels with lower energy consumption using new designs and new technology. The upgrading of lighting and control systems will often give good cost-benefit ratios and short amortisation periods.
This document does not give guidelines on the selection of lighting classes for toll stations, tunnels or canals and locks.
- Technical report26 pagesEnglish languagesale 10% offe-Library read for1 day
- Technical report26 pagesEnglish languagesale 10% offe-Library read for1 day
- Technical report – translation26 pagesSlovenian languagesale 10% offe-Library read for1 day