SIST EN 302 248 V1.1.2:2008
Electromagnetic compatibility and Radio spectum Matters (ERM) - Navigation radar for use on non-SOLAS vessels: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive
- Abstract
Harmonised EN under article 3.2 of 1999/5/EC
The present document applies to non-SOLAS radar equipment.
The present document is intended to cover the provisions of Directive 1999/5/EC [i.1] (R&TTE Directive) Article 3.2, which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of Article 3 of the R&TTE Directive [i.1] may apply to equipment within the scope of the present. This radar equipment operates in the frequency range 2 900 MHz to 3 100 MHz or 9 300 MHz to 9 500 MHz allocated to the radio navigation service as defined in article 5 of the Radio Regulations [6].
- Status
- Published
- Public Enquiry End Date
- 30-Sep-2007
- Publication Date
- 25-Aug-2008
- Technical Committee
- MOC - Mobile Communications
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 08-Aug-2008
- Due Date
- 13-Oct-2008
- Completion Date
- 26-Aug-2008
- Mandate
- M/284
Buy Documents
ETSI EN 302 248 V1.1.2 (2008-04) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Navigation radar for use on non-SOLAS vessels; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive
ETSI EN 302 248 V1.1.2 (2008-06) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Navigation radar for use on non-SOLAS vessels; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive
SIST EN 302 248 V1.1.2:2008 is the SIST publication of an ETSI harmonized European standard for navigation radar for use on non-SOLAS vessels. It specifies the electromagnetic compatibility and radio spectrum requirements that this radar equipment must meet to support Article 3.2 of the R&TTE Directive, with the main aim of using spectrum effectively and avoiding harmful interference. The standard is used by radar manufacturers, test laboratories, and conformity assessors working with equipment in the 2 900 MHz to 3 100 MHz or 9 300 MHz to 9 500 MHz bands.
What does SIST EN 302 248 V1.1.2:2008 specify?
SIST EN 302 248 V1.1.2:2008 applies to non-SOLAS radar equipment and sets the technical basis for demonstrating conformity with the essential radio requirement in Article 3.2 of Directive 1999/5/EC. It is focused on navigation radar in the radio navigation service bands and is written so that other ENs may be used alongside it for other essential requirements under Article 3.
The document is organized into scope, references, symbols and abbreviations, technical requirements, test methods, and four annexes.
| Annex | What it covers |
|---|---|
| Annex A | HS Requirements and conformance Test specifications Table (HS-RTT) linking each requirement to its test |
| Annex B | Radiated measurement sites, antenna arrangements, site verification, and practical guidance for radiated tests |
| Annex C | Transmission power and unwanted emissions of radar systems, including measuring methods and limit figures |
| Annex D | EN title in the official languages |
What are the key requirements of SIST EN 302 248 V1.1.2:2008?
SIST EN 302 248 V1.1.2:2008 is built around five essential radio performance checks: radiated emissions, operating frequency, transmitter pulse power, out of band emissions, and radiated spurious emissions. Clause 5 turns those requirements into laboratory procedures, so a manufacturer or test house can move from design data to a test report that supports conformity.
Environmental profile, clause 4.1 - Tests have to be run at representative points within the declared operational environment, at minimum within the document’s own test conditions. In practice, this means the equipment must be checked under conditions that reflect real use, not only in a single comfortable lab setting.
Radiated emissions, clause 4.2.1 and 5.3.1 - The radar’s unwanted radiated signals outside the operating frequency are limited when measured at 3 m over 150 kHz to 2 GHz. Clause 5.3.1 uses the EN 60945 method. This matters because the radar must not disturb other shipboard equipment such as receivers or rate-of-turn indicators.
Operating frequency, clause 4.2.2 and 5.3.2 - The radar has to remain within one of the two allocated bands stated in the scope, across all switchable ranges and pulse durations. The test procedure checks the strongest spectral line from the transmitted pulse. In practice, this confirms that the radar stays on its assigned spectrum.
Transmitter pulse power, clause 4.2.3 and 5.3.3 - Pulse power at the antenna side of the Rotary Joint (RJ) must match the manufacturer’s declared value within the permitted tolerance. Clause 5.3.3 allows either direct pulse-power measurement or a calculation based on mean power, pulse duration, and Pulse Repetition Time (PRT). This matters because installers and buyers need to know the radar delivers its stated performance.
Out of band emissions, clause 4.2.4 and 5.3.4 - The standard defines an Out Of Band (OOB) boundary using the pulse characteristics of the radar and then limits the radiated power outside the operating band. Clause 5.3.4 uses the ITU-R Recommendation M.1177-3 setup and asks for shortest-range operation during the test. This controls energy that could interfere with adjacent spectrum users.
Radiated spurious emissions, clause 4.2.5 and 5.3.5 - Harmonics, parasitic emissions, intermodulation products, and frequency-conversion products are limited relative to the Peak Envelope Power (PEP) level of the operating signal. The test method again uses the ITU-R Recommendation M.1177-3 arrangement and swept measurements over the higher and lower bands listed in the clause. This is the check that catches unwanted emissions far away from the operating channel.
Test conditions and uncertainty, clauses 5.1 and 5.2 - The document fixes the standard radar operating mode, normal and extreme temperature and humidity ranges, supply-voltage tolerances for AC and DC equipment, and the way measurement uncertainty is reported. It also sets maximum uncertainty figures for RF frequency, RF pulse power, and transmitter radiated emission. In practice, the test report has to show not only the reading but also how reliable that reading is.
What terms does SIST EN 302 248 V1.1.2:2008 define?
- Equipment Under Test (EUT) - The radar equipment being measured in the compliance test.
- Harmonized Standard (HS) - A standard intended to support presumption of conformity with a legal essential requirement.
- Open Area Test Site (OATS) - An outdoor radiated-measurement site with a ground plane and antenna mast.
- Peak Envelope Power (PEP) - The peak power reference used for the spurious-emission limit.
- Pulse Repetition Time (PRT) - The time between radar pulses, used when calculating pulse power.
- Rotary Joint (RJ) - The rotating interface between the radar antenna and the feed path.
- Out Of Band (OOB) - Emissions outside the operating band but inside the wider region controlled by the radar mask.
- Safety Of Life At Sea (SOLAS) - The maritime safety convention whose scope is used to distinguish non-SOLAS vessels in this standard.
Who uses SIST EN 302 248 V1.1.2:2008?
SIST EN 302 248 V1.1.2:2008 is used by radar manufacturers, maritime electronics suppliers, and design engineers who need to build equipment that stays within the allocated bands and emission limits. Test laboratories use it to set up radiated-emission, frequency, power, and unwanted-emission measurements.
Quality managers, compliance teams, and buyers use it to specify acceptance criteria, review test reports, and check that a radar design has been tested under the right operating and environmental conditions. It is also relevant to certification and conformity assessment work for equipment intended for non-SOLAS vessels.
Which standards are used with SIST EN 302 248 V1.1.2:2008?
| Standard | What it contributes |
|---|---|
| CENELEC EN 60945 | General maritime navigation and radiocommunication test methods and results for radiated emissions testing |
| ITU-R Recommendation M.1177-3 | Measurement techniques and test arrangements for unwanted emissions of radar systems |
| ANSI C63.5 | Antenna calibration methods used in radiated-emission measurements |
| ETSI TR 100 028 | Measurement uncertainty guidance for mobile radio equipment characteristics |
| ETSI TR 102 273 | Improvement of radiated measurement methods and evaluation of measurement uncertainty |
| ITU Radio Regulations | The radio-navigation service allocation and regulatory background for the operating bands |
| Directive 1999/5/EC | The R&TTE Directive referenced by the standard for Article 3.2 conformity |
| ITU-R Recommendation SM.1541-1 | Guidance for out-of-band emissions and the calculation of the radar OOB mask |
What does the SIST EN 302 248 V1.1.2:2008 document contain?
The document contains the requirement clauses for radiated emissions, operating frequency, transmitter pulse power, out of band emissions, and radiated spurious emissions. It also contains the test conditions for standard, normal, and extreme operation, including power supply and environmental settings.
Annex A provides the HS-RTT table that links each requirement to its test clause and marks whether the requirement is unconditional and whether the test is essential. Annex B describes free-field radiated test sites, antenna arrangements, site verification, cable routing, and range-length guidance. Annex C gives indirect connection methods through the rotating joint and the measurement bands and masks for unwanted emissions. Annex D lists the standard title in the official languages.
Buy Documents
ETSI EN 302 248 V1.1.2 (2008-04) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Navigation radar for use on non-SOLAS vessels; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive
ETSI EN 302 248 V1.1.2 (2008-06) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Navigation radar for use on non-SOLAS vessels; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive
Get Certified
Connect with accredited certification bodies for this standard

DNV
DNV is an independent assurance and risk management provider.

Lloyd's Register
Lloyd's Register is a global professional services organisation specialising in engineering and technology.

FSC International
Forest Stewardship Council certification.
Sponsored listings
Frequently Asked Questions
SIST EN 302 248 V1.1.2:2008 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electromagnetic compatibility and Radio spectum Matters (ERM) - Navigation radar for use on non-SOLAS vessels: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive". This standard covers: Harmonised EN under article 3.2 of 1999/5/EC The present document applies to non-SOLAS radar equipment. The present document is intended to cover the provisions of Directive 1999/5/EC [i.1] (R&TTE Directive) Article 3.2, which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of Article 3 of the R&TTE Directive [i.1] may apply to equipment within the scope of the present. This radar equipment operates in the frequency range 2 900 MHz to 3 100 MHz or 9 300 MHz to 9 500 MHz allocated to the radio navigation service as defined in article 5 of the Radio Regulations [6].
Harmonised EN under article 3.2 of 1999/5/EC The present document applies to non-SOLAS radar equipment. The present document is intended to cover the provisions of Directive 1999/5/EC [i.1] (R&TTE Directive) Article 3.2, which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of Article 3 of the R&TTE Directive [i.1] may apply to equipment within the scope of the present. This radar equipment operates in the frequency range 2 900 MHz to 3 100 MHz or 9 300 MHz to 9 500 MHz allocated to the radio navigation service as defined in article 5 of the Radio Regulations [6].
SIST EN 302 248 V1.1.2:2008 is classified under the following ICS (International Classification for Standards) categories: 33.060.99 - Other equipment for radiocommunications; 33.100.01 - Electromagnetic compatibility in general; 47.020.70 - Navigation and control equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 302 248 V1.1.2:2008 is associated with the following European legislation: EU Directives/Regulations: 1999/5/EC, TRRTP124; Standardization Mandates: M/284. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 302 248 V1.1.2:2008 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 References
- 2.1 Normative references
- 7 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 2.2 Informative references
- 3 Symbols and abbreviations
- 3.1 Symbols
- 3.2 Abbreviations
- 8 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 4 Technical requirements
- 4.1 Environmental profile
- 4.2 Conformance requirements
- 30 MHz to 156 MHz 120 kHz
- 9 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 10 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 11 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 5 Testing for compliance with technical requirements
- 5.1 Test conditions, power supply and ambient temperatures
- 12 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 5.2 Interpretation of the measurement results
- 13 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 5.3 Essential radio test suites
- 14 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 5.4 Other test specifications
- 15 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 16 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 17 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 18 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 19 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 20 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 21 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 22 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 23 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 24 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 25 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 26 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 27 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- 28 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
1 Scope
The present document applies to non-SOLAS radar equipment.
The present document is intended to cover the provisions of Directive 1999/5/EC [7] (R&TTE Directive) Article 3.2, which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of Article 3 of the R&TTE Directive [7] may apply to equipment within the scope of the present. This radar equipment operates in the frequency range 2 900 MHz to 3 100 MHz or 9 300 MHz to 9 500 MHz allocated to the radio navigation service as defined in article 5 of the Radio Regulations [6].
2 References
References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
- For a specific reference, subsequent revisions do not apply.
- Non-specific reference may be made only to a complete document or a part thereof and only in the following cases:
- if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document;
- for informative references.
Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.
For online referenced documents, information sufficient to identify and locate the source shall be provided. Preferably, the primary source of the referenced document should be cited, in order to ensure traceability. Furthermore, the reference should, as far as possible, remain valid for the expected life of the document. The reference shall include the method of access to the referenced document and the full network address, with the same punctuation and use of upper case and lower case letters.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity.
2.1 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies.
[1] CENELEC EN 60945 (Edition 4 - 2002): "Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results". [2] ITU-R Recommendation M.1177-3 (2003): "Techniques for measurement of unwanted emissions of radar systems".
[3] ANSI C63.5 (1988): "American National Standard for Calibration of Antennas Used for Radiated Emission Measurements in Electromagnetic Interference (EMI) Control". [4] ETSI TR 100 028 (V1.3.1 - all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics". ETSI
7 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
[5] ETSI TR 102 273 (2001): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Improvement on Radiated Methods of Measurement (using test site) and evaluation of the corresponding measurement uncertainties".
[6] ITU Radio Regulations.
2.2 Informative references
The following referenced documents are not essential to the use of the present document but they assist the user with regard to a particular subject area. For non-specific references, the latest version of the referenced document (including any amendments) applies.
[7] Directive 1999/5/EC of The European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (R&TTE Directive).
[8] Directive 98/34/EC of the European Parliament and of the Council laying down a procedure for the provision of information in the field of technical standards and regulations and of rules on information society services.
[9] ITU-R Recommendation SM.1541-1: "Unwanted emissions in the out-of-band domain".
3 Symbols and abbreviations
3.1 Symbols
For the purposes of the present document, the following symbols apply:
B -40 dB bandwidth
P Transmission mean power
m P Transmission pulse power
t t Time t Transmission pulse duration
p t Pulse rise time
r
3.2 Abbreviations
For the purposes of the present document, the following abbreviations apply:
EBL Electronic Bearing Line EUT Equipment Under Test FTC Fast Time Constant HS Harmonized Standard LNA Low Noise Amplifier OATS Open Area Test Site OOB Out Of Band PEP Peak Envelope Power PRT Pulse Repetition Time RF Radio Frequency RJ Rotary Joint SOLAS Safety Of Life At Sea STC Sensitivity Time Control VRM Variable Range Marker VSWR Voltage Standing Wave Radio ETSI
8 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
4 Technical requirements
4.1 Environmental profile
Tests defined in the present document shall be carried out at representative points within the boundary limits of the declared operational environmental profile which, as a minimum, shall be that specified in the test conditions contained in the present document.
As technical performance varies subject to environmental conditions, tests shall be carried out under a sufficient variety of environmental conditions as specified in the present document to give confidence of compliance for the affected technical requirements (which shall also be within the boundary limits of the declared operational environmental profile).
4.2 Conformance requirements
4.2.1 Radiated emissions
4.2.1.1 Definition
Radiated electromagnetic emissions are to be understood as any signals radiated by the completely assembled and operated radar equipment, other than the operating frequency, with its spectra, which can potentially disturb other equipment on the ship, such as radio receivers or rate of turn indicators.
4.2.1.2 Limits
In the frequency range 150 kHz to 2 GHz, the measured radio frequency field strength at a distance of 3 m caused by the EUT shall not exceed the limits shown in table 1.
Table 1: Radiated electromagnetic emission Frequency range Measuring Bandwidth Limits 150 kHz to 300 kHz 9 kHz 10 mV/m to 316 μV/m (80 dBμV/m to 52 dBμV/m) 300 kHz to 30 MHz 9 kHz 316 μV/m to 50 μV/m (52 dBμV/m to 34 dBμV/m)
30 MHz to 156 MHz 120 kHz
500 μV/m (54 dBμV/m) and 165 MHz to 2 GHz 156 MHz to 165 MHz 9 kHz 16 μV/m (24 dBμV/m) quasi peak or 32 μV /m (30 dBμV/m) peak
4.2.1.3 Conformance
Conformance tests as defined in clause 5.3.1 shall be carried out.
4.2.2 Operating frequency
4.2.2.1 Definition
The transmitter produces short microwave pulses, which causes a broad frequency spectrum, depending on the pulse duration and the pulse repetition frequency. The operating frequency is to be understood as the frequency of the microwave during the transmitting pulse and is represented by the spectral line of highest amplitude.
4.2.2.2 Limits
In all switchable distance ranges and pulse durations the operation frequency of the radar equipment shall have values in the range of 2 900 MHz to 3 100 MHz or 9 300 MHz to 9 500 MHz. ETSI
9 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
4.2.2.3 Conformance
Conformance tests as defined in clause 5.3.2 shall be carried out.
4.2.3 Transmitter pulse power
4.2.3.1 Definition
Transmitter pulse power P is to be understood as the mean value of the microwave power during the transmission pulse t at the antenna side of the Rotary Joint (RJ). For the arithmetic mean value of the transmitting power, integrated over the PRT, the abbreviation P will be used.
m
4.2.3.2 Limits
The transmitter pulse power P shall be as specified by the manufacturer +0 dB to -3 dB. t
4.2.3.3 Conformance
Conformance tests as defined in clause 5.3.3 shall be carried out.
4.2.4 Out of band emissions
4.2.4.1 Definition
ITU-R Recommendation SM.1541-1 [9] gives guidance to calculate the -40 dB bandwidth and to specify the OOB mask for primary radars in per cent of the -40 dB bandwidth (see figure 1). The -40 dB bandwidth (B ) for primary radars shall be determined with the following established formula by using the
lesser of:
K 64 B = or −40 t t ×t r where the coefficient K is 6,2 for radars with output power greater than 100 kW and 7,6 for lower-power radars and radars operating in the radio navigation service in the 2 900 MHz to 3 100 MHz and 9 300 MHz to 9 500 MHz band. The latter expression applies if the rise time t is less than about 0,0094t when K is 6,2 or about 0,014t when K is 7,6. r
Attenuation (dBpp)
0 100 200 300 400 500 600 Frequency separation (per cent of 40 dB bandwidth)
Figure 1: OOB mask for primary radars ETSI
10 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
For ideal rectangular pulses, the spectrum falls off at 20 dB per decade leading to a B of 6,4/t and a 40 dB bandwidth
ten times as large, i.e. 64/t. To discourage the use of pulses with abrupt rise and fall times, no margin is allowed. The spectra of trapezoidal pulses fall off firstly at 20 dB per decade and then ultimately at 40 dB per decade. If the radio or rise time to pulse duration exceeds 0,008 the 40 dB points will fall on the 40 dB per decade slope, in which case the bandwidth B would be:
5,7 B = −40 t×t r e.g. a radar with a fixed 10 ns rise time would result in bandwidth values as shown in table 2. Table 2: Examples of -40 dB bandwidth of a primary radar at different pulse durations (rise time = 10 ns) Pulse duration - 40 dB bandwidth B
Short pulse (t = 50 ns) B = 255 MHz
Medium Pulse (t = 200 ns) B = 127 MHz
B = 81 MHz Long Pulse (t = 500 ns)
4.2.4.2 Limits
The maximum radiated Out Of Band-emission power level shall not exceed the limits given in figure C.3.
4.2.4.3 Conformance
Conformance tests as defined in clause 5.3.4 shall be carried out.
4.2.5 Radiated spurious emissions
4.2.5.1 Definition
Spurious emissions are defined as the entity of all emissions in the frequency range of 70 % of the cut-off frequency of the waveguide to 26 GHz, but outside the OOB-boundaries.
They include:
- harmonic emissions (whole multiples of the operating frequency);
- parasitic emissions (independent, accidentally);
- intermodulation (between oscillator- and operation frequency or between oscillator and harmonics);
- emissions caused by frequency conversions.
4.2.5.2 Limits
All radiated spurious emission levels shall be 43+10 log PEP or 60 dB below the PEP level of the radiated operating frequency (see figure C.3) whichever is less stringent.
4.2.5.3 Conformance
Conformance tests as defined in clause 5.3.5 shall be carried out. ETSI
11 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
5 Testing for compliance with technical requirements
5.1 Test conditions, power supply and ambient temperatures
5.1.1 Standard operating mode of the radar equipment
Unless otherwise stated the radar equipment shall be set to the standard operating mode which is understood to be as follows:
Operation state: on (antenna turns); Antenna height: 7 m; RANGE: shortest; TUNE setting: optimal; GAIN setting: optimal; STC setting: zero; FTC setting: off; Range rings: visible; VRM: visible; EBL: visible; Brilliance of all attributes: optimal (well readable).
5.1.2 Normal test conditions
5.1.2.1 Normal temperature and humidity
The temperature and humidity conditions for tests shall be a combination of temperature and humidity within the following ranges:
o o a) temperature: +15 C to +35 C; or within the manufacturers stated operating range and stated in the report; b) relative humidity: 20 % to 75 %.
When the relative humidity is lower than 20 %, it shall be stated in the test report.
5.1.2.2 Normal test power supply
5.1.2.2.1 AC test power supply The test voltage for equipment to be connected to an AC supply shall be the nominal mains voltage declared by the manufacturer -10 % to +10 %. For the purpose of the present document, the nominal voltage shall be the declared voltage or any of the declared voltages for which the equipment is indicated as having been designed. The frequency of the test voltage shall be 50 Hz ±1 Hz.
ETSI
12 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
5.1.2.2.2 DC test power supply Where the equipment is designed to operate from a DC source, the normal test voltage shall be the nominal voltage as declared by the manufacturer -10 % to +20 %.
The internal impedance of the test power source shall be low enough for its effect on the test results to be negligible. For the purpose of testing the power source voltage shall be measured at the input terminals of the equipment. During testing, the power source voltages shall be maintained within a tolerance of ±3 % relative to the voltage level at the beginning of each test.
5.1.3 Extreme test conditions
5.1.3.1 Extreme temperatures
5.1.3.1.1 Indoor unit The temperature and humidity conditions for extreme tests shall be a combination of nominal temperature and humidity within the following ranges:
o o a) temperature: 0 C to +40 C; b) relative humidity: 20 % to 75 %.
When the relative humidity is lower than 20 %, it shall be stated in the test report. 5.1.3.1.2 Outdoor unit The temperature and humidity conditions for extreme tests shall be a combination of nominal temperature and humidity within the following ranges:
o o a) temperature: -20 C to +55 C; b) relative humidity: 20 % to 93 %.
When the relative humidity is lower than 20 %, it shall be stated in the test report.
5.1.3.2 Extreme power supply voltage test conditions
The extreme power supply test voltages applied to the equipment shall be according to table 3. Table 3: Extreme power supply voltage and frequency tolerances Power supply Voltage variation % Frequency variation % AC ±10 ±5 DC +20 Not applicable
5.2 Interpretation of the measurement results
The interpretation of the results recorded in a test report for the measurements described in the present document shall be as follows:
- the measured value related to the corresponding limit shall be used to decide whether an equipment meets the requirements of the present document;
- the value of the measurement uncertainty for the measurement of each parameter shall be included in the test report; ETSI
13 Final draft ETSI EN 302 248 V1.1.2 (2008-04)
- the recorded value of the measurement uncertainty shall be, for each measurement, equal to or lower than the figures in table 2.
For the test methods, according to the present document, the measurement uncertainty figures shall be calculated in accordance with TR 100 028 [4] and shall correspond to an expansion factor (coverage factor) k = 1,96 or k = 2 (which provide confidence levels of respectively 95 % and 95,45 % in the case where the distributions characterizing the actual measurement uncertainties are normal (Gaussian)).
Table 4 is based on such expansion factors.
Table 4: Absolute measurement uncertainties: maximum values Parameter Maximum uncertainty
RF frequency 7 1 x 10 RF pulse power 1,5 dB Radiated emission of transmitter 6 dB
...
Contents
- 1 Scope
- 2 References
- 2.1 Normative references
- 7 ETSI EN 302 248 V1.1.2 (2008-06)
- 2.2 Informative references
- 3 Symbols and abbreviations
- 3.1 Symbols
- 3.2 Abbreviations
- 8 ETSI EN 302 248 V1.1.2 (2008-06)
- 4 Technical requirements
- 4.1 Environmental profile
- 4.2 Conformance requirements
- 30 MHz to 156 MHz 120 kHz
- 9 ETSI EN 302 248 V1.1.2 (2008-06)
- 10 ETSI EN 302 248 V1.1.2 (2008-06)
- 11 ETSI EN 302 248 V1.1.2 (2008-06)
- 5 Testing for compliance with technical requirements
- 5.1 Test conditions, power supply and ambient temperatures
- 12 ETSI EN 302 248 V1.1.2 (2008-06)
- 5.2 Interpretation of the measurement results
- 13 ETSI EN 302 248 V1.1.2 (2008-06)
- 5.3 Essential radio test suites
- 14 ETSI EN 302 248 V1.1.2 (2008-06)
- 15 ETSI EN 302 248 V1.1.2 (2008-06)
- 5.4 Other test specifications
- 16 ETSI EN 302 248 V1.1.2 (2008-06)
- 17 ETSI EN 302 248 V1.1.2 (2008-06)
- 18 ETSI EN 302 248 V1.1.2 (2008-06)
- 19 ETSI EN 302 248 V1.1.2 (2008-06)
- 20 ETSI EN 302 248 V1.1.2 (2008-06)
- 21 ETSI EN 302 248 V1.1.2 (2008-06)
- 22 ETSI EN 302 248 V1.1.2 (2008-06)
- 23 ETSI EN 302 248 V1.1.2 (2008-06)
- 24 ETSI EN 302 248 V1.1.2 (2008-06)
- 25 ETSI EN 302 248 V1.1.2 (2008-06)
- 26 ETSI EN 302 248 V1.1.2 (2008-06)
- 27 ETSI EN 302 248 V1.1.2 (2008-06)
- 28 ETSI EN 302 248 V1.1.2 (2008-06)
- 29 ETSI EN 302 248 V1.1.2 (2008-06)
- 30 ETSI EN 302 248 V1.1.2 (2008-06)
1 Scope
The present document applies to non-SOLAS radar equipment.
The present document is intended to cover the provisions of Directive 1999/5/EC [i.1] (R&TTE Directive) Article 3.2, which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of Article 3 of the R&TTE Directive [i.1] may apply to equipment within the scope of the present. This radar equipment operates in the frequency range 2 900 MHz to 3 100 MHz or 9 300 MHz to 9 500 MHz allocated to the radio navigation service as defined in article 5 of the Radio Regulations [6].
2 References
References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
- For a specific reference, subsequent revisions do not apply.
- Non-specific reference may be made only to a complete document or a part thereof and only in the following cases:
- if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document;
- for informative references.
Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.
For online referenced documents, information sufficient to identify and locate the source shall be provided. Preferably, the primary source of the referenced document should be cited, in order to ensure traceability. Furthermore, the reference should, as far as possible, remain valid for the expected life of the document. The reference shall include the method of access to the referenced document and the full network address, with the same punctuation and use of upper case and lower case letters.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity.
2.1 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies.
[1] CENELEC EN 60945 (Edition 4 - 2002): "Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results". [2] ITU-R Recommendation M.1177-3 (2003): "Techniques for measurement of unwanted emissions of radar systems".
[3] ANSI C63.5 (1988): "American National Standard for Calibration of Antennas Used for Radiated Emission Measurements in Electromagnetic Interference (EMI) Control". [4] ETSI TR 100 028 (V1.3.1 - all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics". ETSI
7 ETSI EN 302 248 V1.1.2 (2008-06)
[5] ETSI TR 102 273 (2001): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Improvement on Radiated Methods of Measurement (using test site) and evaluation of the corresponding measurement uncertainties".
[6] ITU Radio Regulations.
2.2 Informative references
The following referenced documents are not essential to the use of the present document but they assist the user with regard to a particular subject area. For non-specific references, the latest version of the referenced document (including any amendments) applies.
[i.1] Directive 1999/5/EC of The European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (R&TTE Directive).
[i.2] Directive 98/34/EC of the European Parliament and of the Council laying down a procedure for the provision of information in the field of technical standards and regulations and of rules on information society services.
[i.3] ITU-R Recommendation SM.1541-1: "Unwanted emissions in the out-of-band domain".
3 Symbols and abbreviations
3.1 Symbols
For the purposes of the present document, the following symbols apply:
B -40 dB bandwidth
P Transmission mean power
m P Transmission pulse power
t t Time t Transmission pulse duration
p t Pulse rise time
r
3.2 Abbreviations
For the purposes of the present document, the following abbreviations apply:
EBL Electronic Bearing Line EUT Equipment Under Test FTC Fast Time Constant HS Harmonized Standard LNA Low Noise Amplifier OATS Open Area Test Site OOB Out Of Band PEP Peak Envelope Power PRT Pulse Repetition Time RF Radio Frequency RJ Rotary Joint SOLAS Safety Of Life At Sea STC Sensitivity Time Control VRM Variable Range Marker VSWR Voltage Standing Wave Radio ETSI
8 ETSI EN 302 248 V1.1.2 (2008-06)
4 Technical requirements
4.1 Environmental profile
Tests defined in the present document shall be carried out at representative points within the boundary limits of the declared operational environmental profile which, as a minimum, shall be that specified in the test conditions contained in the present document.
As technical performance varies subject to environmental conditions, tests shall be carried out under a sufficient variety of environmental conditions as specified in the present document to give confidence of compliance for the affected technical requirements (which shall also be within the boundary limits of the declared operational environmental profile).
4.2 Conformance requirements
4.2.1 Radiated emissions
4.2.1.1 Definition
Radiated electromagnetic emissions are to be understood as any signals radiated by the completely assembled and operated radar equipment, other than the operating frequency, with its spectra, which can potentially disturb other equipment on the ship, such as radio receivers or rate of turn indicators.
4.2.1.2 Limits
In the frequency range 150 kHz to 2 GHz, the measured radio frequency field strength at a distance of 3 m caused by the EUT shall not exceed the limits shown in table 1.
Table 1: Radiated electromagnetic emission Frequency range Measuring Bandwidth Limits 150 kHz to 300 kHz 9 kHz 10 mV/m to 316 μV/m (80 dBμV/m to 52 dBμV/m) 300 kHz to 30 MHz 9 kHz 316 μV/m to 50 μV/m (52 dBμV/m to 34 dBμV/m)
30 MHz to 156 MHz 120 kHz
500 μV/m (54 dBμV/m) and 165 MHz to 2 GHz 156 MHz to 165 MHz 9 kHz 16 μV/m (24 dBμV/m) quasi peak or 32 μV /m (30 dBμV/m) peak
4.2.1.3 Conformance
Conformance tests as defined in clause 5.3.1 shall be carried out.
4.2.2 Operating frequency
4.2.2.1 Definition
The transmitter produces short microwave pulses, which causes a broad frequency spectrum, depending on the pulse duration and the pulse repetition frequency. The operating frequency is to be understood as the frequency of the microwave during the transmitting pulse and is represented by the spectral line of highest amplitude.
4.2.2.2 Limits
In all switchable distance ranges and pulse durations the operation frequency of the radar equipment shall have values in the range of 2 900 MHz to 3 100 MHz or 9 300 MHz to 9 500 MHz. ETSI
9 ETSI EN 302 248 V1.1.2 (2008-06)
4.2.2.3 Conformance
Conformance tests as defined in clause 5.3.2 shall be carried out.
4.2.3 Transmitter pulse power
4.2.3.1 Definition
Transmitter pulse power P is to be understood as the mean value of the microwave power during the transmission pulse t at the antenna side of the Rotary Joint (RJ). For the arithmetic mean value of the transmitting power, integrated over the PRT, the abbreviation P will be used.
m
4.2.3.2 Limits
The transmitter pulse power P shall be as specified by the manufacturer +0 dB to -3 dB. t
4.2.3.3 Conformance
Conformance tests as defined in clause 5.3.3 shall be carried out.
4.2.4 Out of band emissions
4.2.4.1 Definition
ITU-R Recommendation SM.1541-1 [i.3] gives guidance to calculate the -40 dB bandwidth and to specify the OOB mask for primary radars in per cent of the -40 dB bandwidth (see figure 1). The -40 dB bandwidth (B ) for primary radars shall be determined with the following established formula by using the
lesser of:
K 64 B = or −40 t t ×t r where the coefficient K is 6,2 for radars with output power greater than 100 kW and 7,6 for lower-power radars and radars operating in the radio navigation service in the 2 900 MHz to 3 100 MHz and 9 300 MHz to 9 500 MHz band. The latter expression applies if the rise time t is less than about 0,0094t when K is 6,2 or about 0,014t when K is 7,6. r
Attenuation (dBpp)
0 100 200 300 400 500 600 Frequency separation (per cent of 40 dB bandwidth)
Figure 1: OOB mask for primary radars ETSI
10 ETSI EN 302 248 V1.1.2 (2008-06)
For ideal rectangular pulses, the spectrum falls off at 20 dB per decade leading to a B of 6,4/t and a 40 dB bandwidth
ten times as large, i.e. 64/t. To discourage the use of pulses with abrupt rise and fall times, no margin is allowed. The spectra of trapezoidal pulses fall off firstly at 20 dB per decade and then ultimately at 40 dB per decade. If the radio or rise time to pulse duration exceeds 0,008 the 40 dB points will fall on the 40 dB per decade slope, in which case the bandwidth B would be:
5,7 B = −40 t×t r e.g. a radar with a fixed 10 ns rise time would result in bandwidth values as shown in table 2. Table 2: Examples of -40 dB bandwidth of a primary radar at different pulse durations (rise time = 10 ns) Pulse duration - 40 dB bandwidth B
Short pulse (t = 50 ns) B = 255 MHz
Medium Pulse (t = 200 ns) B = 127 MHz
B = 81 MHz Long Pulse (t = 500 ns)
4.2.4.2 Limits
The maximum radiated Out Of Band-emission power level shall not exceed the limits given in figure C.3.
4.2.4.3 Conformance
Conformance tests as defined in clause 5.3.4 shall be carried out.
4.2.5 Radiated spurious emissions
4.2.5.1 Definition
Spurious emissions are defined as the entity of all emissions in the frequency range of 70 % of the cut-off frequency of the waveguide to 26 GHz, but outside the OOB-boundaries.
They include:
- harmonic emissions (whole multiples of the operating frequency);
- parasitic emissions (independent, accidentally);
- intermodulation (between oscillator- and operation frequency or between oscillator and harmonics);
- emissions caused by frequency conversions.
4.2.5.2 Limits
All radiated spurious emission levels shall be 43+10 log PEP or 60 dB below the PEP level of the radiated operating frequency (see figure C.3) whichever is less stringent.
4.2.5.3 Conformance
Conformance tests as defined in clause 5.3.5 shall be carried out. ETSI
11 ETSI EN 302 248 V1.1.2 (2008-06)
5 Testing for compliance with technical requirements
5.1 Test conditions, power supply and ambient temperatures
5.1.1 Standard operating mode of the radar equipment
Unless otherwise stated the radar equipment shall be set to the standard operating mode which is understood to be as follows:
Operation state: on (antenna turns); Antenna height: 7 m; RANGE: shortest; TUNE setting: optimal; GAIN setting: optimal; STC setting: zero; FTC setting: off; Range rings: visible; VRM: visible; EBL: visible; Brilliance of all attributes: optimal (well readable).
5.1.2 Normal test conditions
5.1.2.1 Normal temperature and humidity
The temperature and humidity conditions for tests shall be a combination of temperature and humidity within the following ranges:
o o a) temperature: +15 C to +35 C; or within the manufacturers stated operating range and stated in the report; b) relative humidity: 20 % to 75 %.
When the relative humidity is lower than 20 %, it shall be stated in the test report.
5.1.2.2 Normal test power supply
5.1.2.2.1 AC test power supply The test voltage for equipment to be connected to an AC supply shall be the nominal mains voltage declared by the manufacturer -10 % to +10 %. For the purpose of the present document, the nominal voltage shall be the declared voltage or any of the declared voltages for which the equipment is indicated as having been designed. The frequency of the test voltage shall be 50 Hz ±1 Hz.
ETSI
12 ETSI EN 302 248 V1.1.2 (2008-06)
5.1.2.2.2 DC test power supply Where the equipment is designed to operate from a DC source, the normal test voltage shall be the nominal voltage as declared by the manufacturer -10 % to +20 %.
The internal impedance of the test power source shall be low enough for its effect on the test results to be negligible. For the purpose of testing the power source voltage shall be measured at the input terminals of the equipment. During testing, the power source voltages shall be maintained within a tolerance of ±3 % relative to the voltage level at the beginning of each test.
5.1.3 Extreme test conditions
5.1.3.1 Extreme temperatures
5.1.3.1.1 Indoor unit The temperature and humidity conditions for extreme tests shall be a combination of nominal temperature and humidity within the following ranges:
o o a) temperature: 0 C to +40 C; b) relative humidity: 20 % to 75 %.
When the relative humidity is lower than 20 %, it shall be stated in the test report. 5.1.3.1.2 Outdoor unit The temperature and humidity conditions for extreme tests shall be a combination of nominal temperature and humidity within the following ranges:
o o a) temperature: -20 C to +55 C; b) relative humidity: 20 % to 93 %.
When the relative humidity is lower than 20 %, it shall be stated in the test report.
5.1.3.2 Extreme power supply voltage test conditions
The extreme power supply test voltages applied to the equipment shall be according to table 3. Table 3: Extreme power supply voltage and frequency tolerances Power supply Voltage variation % Frequency variation % AC ±10 ±5 DC +20 Not applicable
5.2 Interpretation of the measurement results
The interpretation of the results recorded in a test report for the measurements described in the present document shall be as follows:
- the measured value related to the corresponding limit shall be used to decide whether an equipment meets the requirements of the present document;
- the value of the measurement uncertainty for the measurement of each parameter shall be included in the test report; ETSI
13 ETSI EN 302 248 V1.1.2 (2008-06)
- the recorded value of the measurement uncertainty shall be, for each measurement, equal to or lower than the figures in table 2.
For the test methods, according to the present document, the measurement uncertainty figures shall be calculated in accordance with TR 100 028 [4] and shall correspond to an expansion factor (coverage factor) k = 1,96 or k = 2 (which provide confidence levels of respectively 95 % and 95,45 % in the case where the distributions characterizing the actual measurement uncertainties are normal (Gaussian)).
Table 4 is based on such expansion factors.
Table 4: Absolute measurement uncertainties: maximum values Parameter Maximum uncertainty
RF frequency 7 1 x 10 RF pulse power 1,5 dB Radiated emission of transmitter 6 dB
5.3 Essential radio test suites
5.3.1 Radiated emissions
On a test site selected from annex B, the EUT shall be placed on a non-conductive support with a height of 1,5 m. When the EUT consists of more than one unit the interconnecting cables shall have the maximum length and type as indicated by the manufacturer or 20 m whichever is shorter. Available input and output ports of the ancillary equipment under test shall be connected to the maximum length of cable as indicated by the manufacturer or 20 m whichever is shorter and terminated to simulate the impedance of the relevant ports of the radio equipment. These cables shall be bundled at the approximate centre of the cable with the bundles of 30 cm to 40 cm in length running in the horizontal plane from the port to which it is connected. If it is impractical to do so because of cable bulk or stiffness, the disposition of the excess cable shall be precisely noted in the test report.
The test antenna shall be placed at a radial distance of 3 m from the edge of the minimum dimension circle, the smallest dimension circle in the horizontal plane that encloses all elements of the indoor- and the outdoor -units, at a height of 1,5 m above the ground plane.
The test method shall be according to EN 60945 [1].
The radiated emission of the EUT shall be measured in the frequency range 150 kHz to 2 GHz. The results obtained shall be compared to the limits in clause 4.2.1.2 in order to prove compliance with the requirement.
...
Contents
- 1 Scope
- 2 References
- 2.1 Normative references
- 7 ETSI EN 302 248 V1.1.2 (2008-06)
- 2.2 Informative references
- 3 Symbols and abbreviations
- 3.1 Symbols
- 3.2 Abbreviations
- 8 ETSI EN 302 248 V1.1.2 (2008-06)
- 4 Technical requirements
- 4.1 Environmental profile
- 4.2 Conformance requirements
- 30 MHz to 156 MHz 120 kHz
- 9 ETSI EN 302 248 V1.1.2 (2008-06)
- 10 ETSI EN 302 248 V1.1.2 (2008-06)
- 11 ETSI EN 302 248 V1.1.2 (2008-06)
- 5 Testing for compliance with technical requirements
- 5.1 Test conditions, power supply and ambient temperatures
- 12 ETSI EN 302 248 V1.1.2 (2008-06)
- 5.2 Interpretation of the measurement results
- 13 ETSI EN 302 248 V1.1.2 (2008-06)
- 5.3 Essential radio test suites
- 14 ETSI EN 302 248 V1.1.2 (2008-06)
- 15 ETSI EN 302 248 V1.1.2 (2008-06)
- 5.4 Other test specifications
- 16 ETSI EN 302 248 V1.1.2 (2008-06)
- 17 ETSI EN 302 248 V1.1.2 (2008-06)
- 18 ETSI EN 302 248 V1.1.2 (2008-06)
- 19 ETSI EN 302 248 V1.1.2 (2008-06)
- 20 ETSI EN 302 248 V1.1.2 (2008-06)
- 21 ETSI EN 302 248 V1.1.2 (2008-06)
- 22 ETSI EN 302 248 V1.1.2 (2008-06)
- 23 ETSI EN 302 248 V1.1.2 (2008-06)
- 24 ETSI EN 302 248 V1.1.2 (2008-06)
- 25 ETSI EN 302 248 V1.1.2 (2008-06)
- 26 ETSI EN 302 248 V1.1.2 (2008-06)
- 27 ETSI EN 302 248 V1.1.2 (2008-06)
- 28 ETSI EN 302 248 V1.1.2 (2008-06)
- 29 ETSI EN 302 248 V1.1.2 (2008-06)
- 30 ETSI EN 302 248 V1.1.2 (2008-06)
1 Scope
The present document applies to non-SOLAS radar equipment.
The present document is intended to cover the provisions of Directive 1999/5/EC [i.1] (R&TTE Directive) Article 3.2, which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of Article 3 of the R&TTE Directive [i.1] may apply to equipment within the scope of the present. This radar equipment operates in the frequency range 2 900 MHz to 3 100 MHz or 9 300 MHz to 9 500 MHz allocated to the radio navigation service as defined in article 5 of the Radio Regulations [6].
2 References
References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
- For a specific reference, subsequent revisions do not apply.
- Non-specific reference may be made only to a complete document or a part thereof and only in the following cases:
- if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document;
- for informative references.
Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.
For online referenced documents, information sufficient to identify and locate the source shall be provided. Preferably, the primary source of the referenced document should be cited, in order to ensure traceability. Furthermore, the reference should, as far as possible, remain valid for the expected life of the document. The reference shall include the method of access to the referenced document and the full network address, with the same punctuation and use of upper case and lower case letters.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity.
2.1 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies.
[1] CENELEC EN 60945 (Edition 4 - 2002): "Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results". [2] ITU-R Recommendation M.1177-3 (2003): "Techniques for measurement of unwanted emissions of radar systems".
[3] ANSI C63.5 (1988): "American National Standard for Calibration of Antennas Used for Radiated Emission Measurements in Electromagnetic Interference (EMI) Control". [4] ETSI TR 100 028 (V1.3.1 - all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics". ETSI
SIST EN 302 248 V1.1.2:2008
7 ETSI EN 302 248 V1.1.2 (2008-06)
[5] ETSI TR 102 273 (2001): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Improvement on Radiated Methods of Measurement (using test site) and evaluation of the corresponding measurement uncertainties".
[6] ITU Radio Regulations.
2.2 Informative references
The following referenced documents are not essential to the use of the present document but they assist the user with regard to a particular subject area. For non-specific references, the latest version of the referenced document (including any amendments) applies.
[i.1] Directive 1999/5/EC of The European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (R&TTE Directive).
[i.2] Directive 98/34/EC of the European Parliament and of the Council laying down a procedure for the provision of information in the field of technical standards and regulations and of rules on information society services.
[i.3] ITU-R Recommendation SM.1541-1: "Unwanted emissions in the out-of-band domain".
3 Symbols and abbreviations
3.1 Symbols
For the purposes of the present document, the following symbols apply:
B -40 dB bandwidth
P Transmission mean power
m P Transmission pulse power
t t Time t Transmission pulse duration
p t Pulse rise time
r
3.2 Abbreviations
For the purposes of the present document, the following abbreviations apply:
EBL Electronic Bearing Line EUT Equipment Under Test FTC Fast Time Constant HS Harmonized Standard LNA Low Noise Amplifier OATS Open Area Test Site OOB Out Of Band PEP Peak Envelope Power PRT Pulse Repetition Time RF Radio Frequency RJ Rotary Joint SOLAS Safety Of Life At Sea STC Sensitivity Time Control VRM Variable Range Marker VSWR Voltage Standing Wave Radio ETSI
SIST EN 302 248 V1.1.2:2008
8 ETSI EN 302 248 V1.1.2 (2008-06)
4 Technical requirements
4.1 Environmental profile
Tests defined in the present document shall be carried out at representative points within the boundary limits of the declared operational environmental profile which, as a minimum, shall be that specified in the test conditions contained in the present document.
As technical performance varies subject to environmental conditions, tests shall be carried out under a sufficient variety of environmental conditions as specified in the present document to give confidence of compliance for the affected technical requirements (which shall also be within the boundary limits of the declared operational environmental profile).
4.2 Conformance requirements
4.2.1 Radiated emissions
4.2.1.1 Definition
Radiated electromagnetic emissions are to be understood as any signals radiated by the completely assembled and operated radar equipment, other than the operating frequency, with its spectra, which can potentially disturb other equipment on the ship, such as radio receivers or rate of turn indicators.
4.2.1.2 Limits
In the frequency range 150 kHz to 2 GHz, the measured radio frequency field strength at a distance of 3 m caused by the EUT shall not exceed the limits shown in table 1.
Table 1: Radiated electromagnetic emission Frequency range Measuring Bandwidth Limits 150 kHz to 300 kHz 9 kHz 10 mV/m to 316 μV/m (80 dBμV/m to 52 dBμV/m) 300 kHz to 30 MHz 9 kHz 316 μV/m to 50 μV/m (52 dBμV/m to 34 dBμV/m)
30 MHz to 156 MHz 120 kHz
500 μV/m (54 dBμV/m) and 165 MHz to 2 GHz 156 MHz to 165 MHz 9 kHz 16 μV/m (24 dBμV/m) quasi peak or 32 μV /m (30 dBμV/m) peak
4.2.1.3 Conformance
Conformance tests as defined in clause 5.3.1 shall be carried out.
4.2.2 Operating frequency
4.2.2.1 Definition
The transmitter produces short microwave pulses, which causes a broad frequency spectrum, depending on the pulse duration and the pulse repetition frequency. The operating frequency is to be understood as the frequency of the microwave during the transmitting pulse and is represented by the spectral line of highest amplitude.
4.2.2.2 Limits
In all switchable distance ranges and pulse durations the operation frequency of the radar equipment shall have values in the range of 2 900 MHz to 3 100 MHz or 9 300 MHz to 9 500 MHz. ETSI
SIST EN 302 248 V1.1.2:2008
9 ETSI EN 302 248 V1.1.2 (2008-06)
4.2.2.3 Conformance
Conformance tests as defined in clause 5.3.2 shall be carried out.
4.2.3 Transmitter pulse power
4.2.3.1 Definition
Transmitter pulse power P is to be understood as the mean value of the microwave power during the transmission pulse t at the antenna side of the Rotary Joint (RJ). For the arithmetic mean value of the transmitting power, integrated over the PRT, the abbreviation P will be used.
m
4.2.3.2 Limits
The transmitter pulse power P shall be as specified by the manufacturer +0 dB to -3 dB. t
4.2.3.3 Conformance
Conformance tests as defined in clause 5.3.3 shall be carried out.
4.2.4 Out of band emissions
4.2.4.1 Definition
ITU-R Recommendation SM.1541-1 [i.3] gives guidance to calculate the -40 dB bandwidth and to specify the OOB mask for primary radars in per cent of the -40 dB bandwidth (see figure 1). The -40 dB bandwidth (B ) for primary radars shall be determined with the following established formula by using the
lesser of:
K 64 B = or −40 t t ×t r where the coefficient K is 6,2 for radars with output power greater than 100 kW and 7,6 for lower-power radars and radars operating in the radio navigation service in the 2 900 MHz to 3 100 MHz and 9 300 MHz to 9 500 MHz band. The latter expression applies if the rise time t is less than about 0,0094t when K is 6,2 or about 0,014t when K is 7,6. r
Attenuation (dBpp)
0 100 200 300 400 500 600 Frequency separation (per cent of 40 dB bandwidth)
Figure 1: OOB mask for primary radars ETSI
SIST EN 302 248 V1.1.2:2008
10 ETSI EN 302 248 V1.1.2 (2008-06)
For ideal rectangular pulses, the spectrum falls off at 20 dB per decade leading to a B of 6,4/t and a 40 dB bandwidth
ten times as large, i.e. 64/t. To discourage the use of pulses with abrupt rise and fall times, no margin is allowed. The spectra of trapezoidal pulses fall off firstly at 20 dB per decade and then ultimately at 40 dB per decade. If the radio or rise time to pulse duration exceeds 0,008 the 40 dB points will fall on the 40 dB per decade slope, in which case the bandwidth B would be:
5,7 B = −40 t×t r e.g. a radar with a fixed 10 ns rise time would result in bandwidth values as shown in table 2. Table 2: Examples of -40 dB bandwidth of a primary radar at different pulse durations (rise time = 10 ns) Pulse duration - 40 dB bandwidth B
Short pulse (t = 50 ns) B = 255 MHz
Medium Pulse (t = 200 ns) B = 127 MHz
B = 81 MHz Long Pulse (t = 500 ns)
4.2.4.2 Limits
The maximum radiated Out Of Band-emission power level shall not exceed the limits given in figure C.3.
4.2.4.3 Conformance
Conformance tests as defined in clause 5.3.4 shall be carried out.
4.2.5 Radiated spurious emissions
4.2.5.1 Definition
Spurious emissions are defined as the entity of all emissions in the frequency range of 70 % of the cut-off frequency of the waveguide to 26 GHz, but outside the OOB-boundaries.
They include:
- harmonic emissions (whole multiples of the operating frequency);
- parasitic emissions (independent, accidentally);
- intermodulation (between oscillator- and operation frequency or between oscillator and harmonics);
- emissions caused by frequency conversions.
4.2.5.2 Limits
All radiated spurious emission levels shall be 43+10 log PEP or 60 dB below the PEP level of the radiated operating frequency (see figure C.3) whichever is less stringent.
4.2.5.3 Conformance
Conformance tests as defined in clause 5.3.5 shall be carried out. ETSI
SIST EN 302 248 V1.1.2:2008
11 ETSI EN 302 248 V1.1.2 (2008-06)
5 Testing for compliance with technical requirements
5.1 Test conditions, power supply and ambient temperatures
5.1.1 Standard operating mode of the radar equipment
Unless otherwise stated the radar equipment shall be set to the standard operating mode which is understood to be as follows:
Operation state: on (antenna turns); Antenna height: 7 m; RANGE: shortest; TUNE setting: optimal; GAIN setting: optimal; STC setting: zero; FTC setting: off; Range rings: visible; VRM: visible; EBL: visible; Brilliance of all attributes: optimal (well readable).
5.1.2 Normal test conditions
5.1.2.1 Normal temperature and humidity
The temperature and humidity conditions for tests shall be a combination of temperature and humidity within the following ranges:
o o a) temperature: +15 C to +35 C; or within the manufacturers stated operating range and stated in the report; b) relative humidity: 20 % to 75 %.
When the relative humidity is lower than 20 %, it shall be stated in the test report.
5.1.2.2 Normal test power supply
5.1.2.2.1 AC test power supply The test voltage for equipment to be connected to an AC supply shall be the nominal mains voltage declared by the manufacturer -10 % to +10 %. For the purpose of the present document, the nominal voltage shall be the declared voltage or any of the declared voltages for which the equipment is indicated as having been designed. The frequency of the test voltage shall be 50 Hz ±1 Hz.
ETSI
SIST EN 302 248 V1.1.2:2008
12 ETSI EN 302 248 V1.1.2 (2008-06)
5.1.2.2.2 DC test power supply Where the equipment is designed to operate from a DC source, the normal test voltage shall be the nominal voltage as declared by the manufacturer -10 % to +20 %.
The internal impedance of the test power source shall be low enough for its effect on the test results to be negligible. For the purpose of testing the power source voltage shall be measured at the input terminals of the equipment. During testing, the power source voltages shall be maintained within a tolerance of ±3 % relative to the voltage level at the beginning of each test.
5.1.3 Extreme test conditions
5.1.3.1 Extreme temperatures
5.1.3.1.1 Indoor unit The temperature and humidity conditions for extreme tests shall be a combination of nominal temperature and humidity within the following ranges:
o o a) temperature: 0 C to +40 C; b) relative humidity: 20 % to 75 %.
When the relative humidity is lower than 20 %, it shall be stated in the test report. 5.1.3.1.2 Outdoor unit The temperature and humidity conditions for extreme tests shall be a combination of nominal temperature and humidity within the following ranges:
o o a) temperature: -20 C to +55 C; b) relative humidity: 20 % to 93 %.
When the relative humidity is lower than 20 %, it shall be stated in the test report.
5.1.3.2 Extreme power supply voltage test conditions
The extreme power supply test voltages applied to the equipment shall be according to table 3. Table 3: Extreme power supply voltage and frequency tolerances Power supply Voltage variation % Frequency variation % AC ±10 ±5 DC +20 Not applicable
5.2 Interpretation of the measurement results
The interpretation of the results recorded in a test report for the measurements described in the present document shall be as follows:
- the measured value related to the corresponding limit shall be used to decide whether an equipment meets the requirements of the present document;
- the value of the measurement uncertainty for the measurement of each parameter shall be included in the test report; ETSI
SIST EN 302 248 V1.1.2:2008
13 ETSI EN 302 248 V1.1.2 (2008-06)
- the recorded value of the measurement uncertainty shall be, for each measurement, equal to or lower than the figures in table 2.
For the test methods, according to the present document, the measurement uncertainty figures shall be calculated in accordance with TR 100 028 [4] and shall correspond to an expansion factor (coverage factor) k = 1,96 or k = 2 (which provide confidence levels of respectively 95 % and 95,45 % in the case where the distributions characterizing the actual measurement uncertainties are normal (Gaussian)).
Table 4 is based on such expansion factors.
Table 4: Absolute measurement uncertainties: maximum values Parameter Maximum uncertainty
RF frequency 7 1 x 10 RF pulse power 1,5 dB Radiated emission of transmitter 6 dB
5.3 Essential radio test suites
5.3.1 Radiated emissions
On a test site selected from annex B, the EUT shall be placed on a non-conductive support with a height of 1,5 m. When the EUT consists of more than one unit the interconnecting cables shall have the maximum length and type as indicated by the manufacturer or 20 m whichever is shorter. Available input and output ports of the ancillary equipment under test shall be connected to the maximum length of cable as indicated by the manufacturer or 20 m whichever is shorter and terminated to simulate the impedance of the relevant ports of the radio equipment. These cables shall be bundled at the approximate centre of the cable with the bundles of 30 cm to 40 cm in length running in the horizontal plane from the port to which it is connected. If it is impractical to do so because of cable bulk or stiffness, the disposition of the excess cable shall be precisely noted in the test report.
The test antenna shall be placed at a radial distance of 3 m from the edge of the minimum dimension circle, the smallest dimension circle in the horizontal plane that encloses all elements of the indoor- and the outdoor -units, at a height of 1,5 m above the ground plane.
The test method shall be according to EN 60945 [1].
The radiated emission of the EUT shall be measured in the frequency range 150 kHz to 2 GHz. The results obtained shall be compared to the limits in clause 4.2.1.2 in order to prove compliance with the requirement.
...