Amendment 1 - Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

Grenzwerte und Messverfahren für Funkstörungen von elektrischen Beleuchtungseinrichtungen und ähnlichen Elektrogeräten

Amendement 1 - Limites et méthodes de mesure des perturbations radioélectriques produites par les appareils électriques d\'éclairage et les appareils analogues

Mejne vrednosti in metode merjenja karakteristik občutljivosti za radijske motnje električne razsvetljave in podobne opreme - Dopolnilo A1

General Information

Status
Not Published
Public Enquiry End Date
30-Jun-2023
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
10-Apr-2024
Due Date
29-May-2024
Completion Date
17-May-2024

Relations

Buy Standard

Draft
EN IEC 55015:2019/oprA1:2023 - BARVE
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
SIST EN IEC 55015:2019/oprA1:2023
01-junij-2023
Mejne vrednosti in metode merjenja karakteristik občutljivosti za radijske motnje
električne razsvetljave in podobne opreme - Dopolnilo A1
Amendment 1 - Limits and methods of measurement of radio disturbance characteristics
of electrical lighting and similar equipment
Grenzwerte und Messverfahren für Funkstörungen von elektrischen
Beleuchtungseinrichtungen und ähnlichen Elektrogeräten
Amendement 1 - Limites et méthodes de mesure des perturbations radioélectriques
produites par les appareils électriques d\'éclairage et les appareils analogues
Ta slovenski standard je istoveten z: EN IEC 55015:2019/prA1:2023
ICS:
33.100.10 Emisija Emission
SIST EN IEC 55015:2019/oprA1:2023 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

SIST EN IEC 55015:2019/oprA1:2023

SIST EN IEC 55015:2019/oprA1:2023
CIS/F/837/CDV
COMMITTEE DRAFT FOR VOTE (CDV)

PROJECT NUMBER:
CISPR 15/AMD1 ED9
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2023-04-21 2023-07-14
SUPERSEDES DOCUMENTS:
CIS/F/821/CD, CIS/F/829A/CC
IEC CIS/F : INTERFERENCE RELATING TO HOUSEHOLD APPLIANCES TOOLS, LIGHTING EQUIPMENT AND SIMILAR APPARATUS
SECRETARIAT: SECRETARY:
Australia Ms Suba Ananth
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

TC 34
Other TC/SCs are requested to indicate their interest, if any,
in this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft for
Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of
• any relevant patent rights of which they are aware and to provide supporting documentation,
• any relevant “in some countries” clauses to be included should this proposal proceed. Recipients are reminded that
the enquiry stage is the final stage for submitting "in some countries" clauses. See AC/22/2007.

TITLE:
Amendment 1 - Limits and methods of measurement of radio disturbance characteristics of electrical
lighting and similar equipment

PROPOSED STABILITY DATE: 2027
NOTE FROM TC/SC OFFICERS:
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.

SIST EN IEC 55015:2019/oprA1:2023
IEC CDV CISPR 15/A1/Ed9 © IEC 2023 – 2 – CIS/F/837/CDV
1 INTRODUCTION
2 This edition includes the following significant technical changes with respect to the previous edition:
3 a) The removal of the voltage probe method for the conducted disturbance measurement of local wired
4 port other than the electrical power supply interface of ELV lamps;
5 b) The introduction of limits and measurement methods for radiated disturbance of the enclosure port
6 in the frequency range 1 – 6 GHz;
7 c) The test set-up for the cconical metal housing for single capped lamps has been rotated;
8 d) The arrangement of cables connected to interfaces of wired network ports has been modified. Cable
9 length has been extended to 1,0 m;
10 e) Measuring arrangements for conducted disturbances for very large EUTs has been clarified.
11 f) Removal of Annex E regarding statistical methods
st
12 g) Includes agreed comments to 1 CD CIS/F/801/CD given in CIS/F/803a/CC
nd
13 h) Includes agreed comments to 2 CD CIS/F/821/CD given in CIS/F/829/CC.
SIST EN IEC 55015:2019/oprA1:2023
IEC CDV CISPR 15/A1/Ed9 © IEC 2023 – 3 – CIS/F/837/CDV
15 1 Scope
16 Replace the first and second paragraph with the following text:
17 This document sets out requirements for controlling the emission (radiated and conducted) of
18 radiofrequency disturbances from:
19 – lighting equipment (3.3.16), except for the types excluded in the second paragraph;
20 – the lighting part of multi-function equipment where this lighting part is a primary function;
21 NOTE 1 Examples are lighting equipment with visible-light communication.
22 – UV and IR radiation equipment for residential and non-industrial applications;
23 – simple advertising signs (see 3.3.1);
24 – decorative and entertainment lighting (see 3.3.6);
25 – emergency signs.
27 Excluded from the scope of this document are:
28 – components or modules intended to be built into lighting equipment and which are not user-
29 replaceable;
30 – lighting equipment intended exclusively for aircraft or airfield facilities (runways, service facilities,
31 platforms);
32 NOTE 2 However, general-purpose lighting that can be installed in many locations, including installations not related to aircraft
33 or airfield, is not excluded from the scope of CISPR 15.
34 – installations;
35 – equipment for which the electromagnetic compatibility requirements in the radio-frequency range
36 are explicitly formulated in other IEC standards, even if they incorporate a built-in lighting function.
37 NOTE 3 Examples of exclusions are:
38 – equipment with built-in lighting devices for display back lighting, scale illumination and signaling;
39 – video signs and dynamic displays (in scope of CISPR 32);
40 – range hoods, refrigerators, freezers (in scope of CISPR 14);
41 – photocopiers, projectors (in scope of CISPR 32);
42 – lighting equipment for road vehicles (in scope of CISPR 12);
43 – maritime equipment (in scope of IEC TC 18 and TC 80);
44 - lighting equipment operating in the ISM frequency bands (in scope of CISPR 11).
46 Replace the sixth paragraph with the following text and additional note:
47 The emission requirements in this document are not intended to be applicable to the intentional
48 transmissions from a radio transmitter as defined by the ITU including their spurious emissions.
SIST EN IEC 55015:2019/oprA1:2023
IEC CDV CISPR 15/A1/Ed9 © IEC 2023 – 4 – CIS/F/837/CDV
52 2  Normative references
53 Replace the references to CISPR 16-1-1 with the following updated reference:
54 CISPR 16-1-1:2019, Specification for radio disturbance and immunity measuring apparatus and
55 methods – Part 1-1: Radio disturbance and immunity measuring apparatus – Measuring apparatus
56 Add the following just below the CISPR 16-1-2 reference:
57 CISPR 16-1-2:2014/AMD1:2017
58 Replace the reference to CISPR 16-1-4 with the following updated reference:
59 CISPR 16-1-4:2019/AMD1:2020, Specification for radio disturbance and immunity measuring apparatus
60 and methods – Part 1-4: Radio disturbance and immunity measuring apparatus – Antennas and test
61 sites for radiated disturbance measurements
63 Insert the following refences to new amendments under the existing references to CISPR 16-2-3 and
64 CISPR 16-4-2 respectively:
65 CISPR 16-2-3:2016/AMD1:2019
66 CISPR 16-4-2:2011/AMD2:2018
67 Insert the following new reference just below the existing reference to CISPR TR 30-1:
68 CISPR TR 30-2:2012, Test method on electromagnetic emissions – Part 2: Electronic control gear for
69 discharge lamps excluding fluorescent lamps
71 Modify definitions 3.2.6 and 3.2.7 to read:
72 3.2.6
73 primary function
74 function of an equipment as specified in the instructions for use
75 3.2.7
76 secondary function
77 any function of an equipment not being essential for fulfilling the primary function as specified in the
78 instructions for use
80 Modify definitions 3.3.1 and 3.3.2 to the following:
81 3.3.1
82 simple advertising sign
83 unit which makes use of lighting for advertising, traffic signage, road signs or alike
84 Note 1 to entry:  Examples are neon tube advertising signs, emergency signs, inner-illuminated signs.
85 3.3.2
86 ancillary equipment
87 transducers (e.g. current probes and artificial networks) and other equipment (e.g. cables, preamplifiers,
88 attenuators, filters, adapters) connected to a measuring receiver or to the EUT and used in the
89 disturbance signal transfer between the EUT and the measuring receiver
91 Add a note to entry at the end of definition 3.3.3:

SIST EN IEC 55015:2019/oprA1:2023
IEC CDV CISPR 15/A1/Ed9 © IEC 2023 – 5 – CIS/F/837/CDV
92 Note 2 to entry: The emission from the associated equipment should not influence the emission of the EUT.
94 Replace the existing term of definition 3.3.6 with the following new term and add two new notes (reusing
95 the same definition):
96 3.3.6
97 decorative and entertainment lighting
98 equipment that emits light for atmospheric, artistic or ambiance purposes
99 Note 1 to entry:  Examples of decorative lighting include LED strip lights, rope lights, and projectors for illuminating building
100 walls or statues in coloured and/or patterned light. Usually, these types of lighting equipment are static, but they can shift
101 through various colours/patterns.
102 Note 2 to entry:  Examples of entertainment lighting include stage, theatre and sky beam lights. Usually, these types of lighting
103 equipment also include some movement, such as dynamically changing the direction of the projected light.”
105 Modify the definition 3.3.16 as follows (keeping the existing Note 1 to entry):
106 3.3.16
107 lighting equipment
108 device that can be used as an independent unit to illuminate a scene, objects or their surroundings so that they
109 can be seen, and modules and components designed to be used in or with such device or assembly of devices
111 Modify definition 3.3.20 to the following:
112 3.3.20
113 restricted ELV lamp
114 ELV lamp with specific restrictions on the type of power supply and/or the cable length that can be
115 applied to it, as specified in the instructions for use
116 Add a new definition for user replaceable:
117 3.3.24
118 User replaceable
119 Components which may be replaced by an ordinary person
120 3.5 Abbreviated terms
121 Correct the term AAN to the following:
AAN asymmetric artificial network
122 Add the term FSOATS:
FSOATS free space open area test site
123 Add the term Fc:
Fc Clock frequency
125 Remove the term ISN
127 4.3.1 Electric power supply interface
128 Add the following note below Table 1:

SIST EN IEC 55015:2019/oprA1:2023
IEC CDV CISPR 15/A1/Ed9 © IEC 2023 – 6 – CIS/F/837/CDV
129 NOTE In the US, lighting devices are classified as either a non-consumer (Class A) or consumer (Class B) device. These
130 classifications limits are similar to the Class A and Class B equipment categories in the CISPR 32:2015+A1 2019 publication.
132 4.3.2 Wired network interfaces other than power supply
133 In NOTE 2 replace the term ‘artificial asymmetrical network’ with ‘asymmetric artificial network’
135 4.4 Limits and methods for the assessment of local wired ports
136 Delete the existing third paragraph.
137 Replace the existing fifth paragraph with:
138 The limits and methods given in Table 6 shall be applied to local wired ports other than electrical power
139 supply interface of ELV lamps.
140 Delete Table 5.
142 Table 6 – Disturbance current limits at local wired ports: local wired ports other than electrical
143 power supply interface of ELV lamp
144 Within the table, renumber existing NOTE 1 to NOTE and delete existing NOTE 2.
146 4.5.2 Frequency range 9 kHz to 30 MHz
147 Replace the fifth paragraph with the following text:
148 The limits in Table 7 and Table 8 provide different options. The test report shall state which method
149 was used and which limits were applied.
150 Replace Table 7 with the following:
151 Table 7 – Maximum EUT dimension that can be used
152 for testing using LLAS with different diameters
Maximum dimension of the EUT, D Loop antenna diameter
m m
D ≤ 1,6
D ≤ 2,4 3
D ≤ 3,2 4
No minimum EUT dimensions are given for the 3 m and 4 m LLAS antenna systems.
However, it is recommended to apply the smallest size of the EUT.
If a small EUT is tested in a large LLAS (i.e., EUT smaller than 1,6 m tested in a 3 m
or 4 m LLAS, or EUT smaller than 2,4 m tested in a 4 m LLAS), it shall be confirmed
that the LLAS is able to detect EUT generated emissions with at least 10 dB of margin
above the measuring instrument’s noise floor.
154 Correct the position of Table 9; insert existing table 9 at the end of 4.5.2 directly after Table 8.
156 4.5.3 Frequency range 30 MHz to 1 GHz
157 Replace the second paragraph with the following text:

SIST EN IEC 55015:2019/oprA1:2023
IEC CDV CISPR 15/A1/Ed9 © IEC 2023 – 7 – CIS/F/837/CDV
158 Table 10 provides different options. The test report shall state which method was used and which limits
159 were applied.
160 Delete Table 9.
161 Insert additional sentence to table note (b) of Table 10:
b
162  The TEM-waveguide is limited to EUTs without cables attached and with a maximum size according to 6.2 of IEC 61000-4-
163 20:2010 (the largest dimension of the enclosure at 1 GHz measuring frequency is one wavelength, 300 mm at 1 GHz). The
164 results taken in a TEM waveguide are converted to field strength for comparison with OATS-based limits at 10 m distance.
166 Add note below Table 10:
167 NOTE In the US, lighting devices are classified as either a non-consumer (Class A) or consumer (Class B) device. These
168 classifications limits are similar to the Class A and Class B equipment categories in the CISPR 32:2015+A1 2019 publication.
170 Insert new clause 4.5.4 with following text:
171 4.5.4 Frequency range 1 GHz to 6 GHz
172 Radiated emission measurements in this frequency range shall be performed up to the frequency determined in
173 accordance with Table 13, based on the highest clock frequency of the EUT. However, if the clock frequencies of
174 the EUT are not known, radiated emission measurements shall be performed up to 6 GHz.
175 Table 13 – Radiated measurement highest frequen
...

Questions, Comments and Discussion