Abstract

The present document covers the EMC requirements for non-radio equipment intended to be used within a public telecommunications network, which provides telecommunications between Network Termination Points (NTPs) (i.e. excluding terminal equipment beyond the NTPs). Examples of such equipment are:
Switching equipment. Such equipment includes:
- local telephone exchanges;
- remote switching concentrators;
- international switches;
- telex switches;
- network packet switches;
- base station controllers, radio network controllers;
- network servers and gateways.
Non-radio transmission equipment and ancillary equipment. Such equipment includes:
- multiplexers;
- line equipment and repeaters, e.g. equipment for:
_ Synchronous Digital Hierarchy (SDH);
_ Plesiochronous Digital Hierarchy (PDH);
_ Asynchronous Transfer Mode (ATM);
such as:
_ Digital Cross Connect systems;
_ network terminations;
_ transmission equipment used in the access network like xDSL.
Power supply equipment. Such equipment includes:
- central power plant;
- end of suite power supplies;
- uninterruptible power supplies;
- stabilized AC power supplies; and
- other dedicated telecommunication network power supplies;
but excludes equipment which is uniquely associated with or integrated in other equipment.
Supervisory equipment. Such equipment includes:
- network management equipment;
- operator access maintenance equipment;
- traffic measurement systems;
- line test units;
- functional test units.
The function of supervision may either be performed by independent equipment or form part of other telecommunication network equipment. If the function of supervision forms part of a telecommunication network equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission) during EMC testing. The environmental classification locations used in the present document refers to TR 101 651 [i.22]. The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures may have to be employed. General purpose equipment, which is used as a part of a telecommunication network, may be covered by the scope of other standards. For such equipment, if those other standards fully cover the requirements of the present document, no further assessment is necessary. Equipment for cabled distribution systems intended only for television and sound signals as defined in EN 50083-2 [3] and optical amplifiers as defined in ITU-T Recommendations G.661 [i.6] and G.662 [i.7] are outside the scope of the present document. Equipment may provide different functions, i.e. switching equipment may also provide transmission functions and transmission equipment may provide storage capabilities etc. All available functions of the EUT are to be tested.

Status
Published
Publication Date
24-Sep-2012
Technical Committee
MOC - Mobile Communications
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
10-Sep-2012
Due Date
15-Nov-2012
Completion Date
25-Sep-2012

Buy Documents

Standard

en_300386v010601o - Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements

English language (50 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

en_300386v010601p - Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements

English language (50 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

SIST EN 300 386 V1.6.1:2012

English language (50 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 300 386 V1.6.1:2012 is the Slovenian adoption of ETSI EN 300 386 V1.6.1 for telecommunication network equipment. It specifies electromagnetic compatibility (EMC) requirements for non-radio equipment used within a public telecommunications network between Network Termination Points (NTPs), so it helps designers, test labs, and buyers assess whether switching, transmission, power supply, and supervisory equipment can operate in real network environments.

What does SIST EN 300 386 V1.6.1:2012 specify?

SIST EN 300 386 V1.6.1:2012 specifies EMC immunity and emission requirements, together with the test methods and test configurations used to check them. It applies to equipment in telecommunication centres and in locations such as offices, customer premises, and outdoor sites.

The scope includes switching equipment, non-radio transmission and ancillary equipment, power supply equipment, and supervisory equipment. It also states that all available functions of the equipment under test (EUT) are to be tested when one device provides several functions.

AnnexWhat it covers
Annex ASurge test method for signal line ports remaining within the building
Annex BEvaluation of test results and test report content
Annex CGuidance for RF ports of multimedia network equipment
Annex DBibliography

What are the key requirements of SIST EN 300 386 V1.6.1:2012?

SIST EN 300 386 V1.6.1:2012 sets the EMC test approach first, then gives product-specific criteria for switching, transmission, DSL access systems, power supply equipment, and supervisory equipment. In practice, the standard is used to verify that the equipment still performs its intended network function while being exposed to defined disturbances.

General test approach

Clause 5 requires immunity tests to be applied one port at a time for conducted tests, with only permanently connected signal ports included. It also says that if a test is judged inappropriate for a port, the decision and justification must be recorded in the test report.

Clause 8 requires the EUT to be configured like a normal installation as closely as possible, with correct terminations, proper earthing, and all covers and access panels in place. This matters because EMC results depend strongly on real cabling, grounding, and mechanical layout.

Clause 9 requires the EUT to be powered and operated in a way that represents normal use, and it allows exercising equipment or software to simulate traffic. Clause 10 defines the general performance criteria:

  • Criterion A - the apparatus continues to operate as intended during the test
  • Criterion B - the apparatus continues to operate as intended after the test
  • Criterion C - temporary loss of function is allowed if the function recovers or can be restored

Disturbance tests and limits

Clauses 5 and 6 identify the main test families: electrostatic discharge, electrical fast transients/burst, surge, conducted RF immunity, radiated RF immunity, voltage dips and interruptions, and emission measurements on AC power, DC power, telecommunication, and radiated ports. The standard also points to different methods for AC and DC ports and for ports that are only used over short cables.

Clause 7 gives the limits and test levels, with separate values for telecommunication centres and other locations. That separation matters because installed environments are not equally severe.

Product-specific performance

Clauses 11 to 14 add criteria for different equipment types. Switching equipment must maintain established connections and controlled call handling, while analogue ports also have noise limits at 600 Ω. Transmission equipment is checked with error counts, frame alignment, synchronization, and data/data-link behaviour. DSL access systems are tested with trained-up links, minimum acceptable noise margin, and checks on bit errors and POTS/ISDN break-through. Power supply equipment is checked at the AC secondary interface, DC secondary interface, and control/signal ports. Supervisory equipment must keep the supervised connection and avoid false alarms.

What terms does SIST EN 300 386 V1.6.1:2012 define?

SIST EN 300 386 V1.6.1:2012 defines several terms that shape how the tests are applied.

  • Equipment Under Test (EUT) - the equipment being checked for EMC performance.
  • Network Termination Points (NTPs) - the boundaries of the public telecommunications network covered by the scope.
  • Performance criterion - the acceptable behaviour limit during or after an electromagnetic test.
  • Telecommunication network ports - ports intended for voice, data, or signalling interconnection with telecommunications or data networks.
  • Primary supply - the public mains or a locally generated AC or DC supply feeding the equipment.
  • Secondary supply - the supply derived from the primary supply and used by the telecommunications equipment.
  • Radio Frequencies (RF) - frequencies above 150 kHz.

Who uses SIST EN 300 386 V1.6.1:2012?

SIST EN 300 386 V1.6.1:2012 is used by EMC test laboratories, equipment designers, conformity assessment teams, quality managers, and buyers of telecommunication network equipment. It is relevant for equipment manufacturers and integrators working on switching systems, transmission systems, DSL access equipment, power supplies, and supervisory or maintenance equipment.

What changed in SIST EN 300 386 V1.6.1:2012 from the previous edition?

SIST EN 300 386 V1.6.1:2012 is the V1.6.1 edition published in 2012 and it follows the earlier V1.5.1 edition listed in the document history.

Which standards are used with SIST EN 300 386 V1.6.1:2012?

The standard relies on a set of measurement and product-interface standards for applying and interpreting the EMC tests. Key examples include:

  • EN 55022 for conducted and radiated emission methods and limits
  • EN 61000-4-2, -4-3, -4-4, -4-5, -4-6, and -4-11 for immunity test methods
  • EN 61000-3-2, -3-3, -3-11, and -3-12 for harmonics and flicker on AC ports
  • ETS 300 132-1 and EN 300 132-2 for power supply interface conditions
  • TR 101 651 for environmental classification of installation locations
  • EN 300 011-1, EN 300 012-1, EN 300 166, ETS 300 232, G.961, G.712, Q.552, and other interface standards for the specific ports being tested

What does the SIST EN 300 386 V1.6.1:2012 document contain?

SIST EN 300 386 V1.6.1:2012 contains test methods, test levels, limits, setup drawings, and performance criteria for EMC assessment. It includes tables for immunity and emission by port type and environment, figures for switching, transmission, DSL, and power supply test configurations, and Annex A with a detailed surge setup for building-contained signal ports.

Annex B explains how to evaluate results and what to include in a test report, including the EUT description, test conditions, uncertainty, calibration status, and any deviations. Annex C gives additional guidance for RF ports in multimedia network equipment, which is useful where telecommunication and cable distribution functions are combined.

Buy Documents

Standard

en_300386v010601o - Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements

English language (50 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

en_300386v010601p - Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements

English language (50 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

SIST EN 300 386 V1.6.1:2012

English language (50 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN 300 386 V1.6.1:2012 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electromagnetic compatibility and Radio spectrum Matters (ERM) - Telecommunication network equipment - ElectroMagnetic Compatibility (EMC) requirements". This standard covers: The present document covers the EMC requirements for non-radio equipment intended to be used within a public telecommunications network, which provides telecommunications between Network Termination Points (NTPs) (i.e. excluding terminal equipment beyond the NTPs). Examples of such equipment are: Switching equipment. Such equipment includes: - local telephone exchanges; - remote switching concentrators; - international switches; - telex switches; - network packet switches; - base station controllers, radio network controllers; - network servers and gateways. Non-radio transmission equipment and ancillary equipment. Such equipment includes: - multiplexers; - line equipment and repeaters, e.g. equipment for: _ Synchronous Digital Hierarchy (SDH); _ Plesiochronous Digital Hierarchy (PDH); _ Asynchronous Transfer Mode (ATM); such as: _ Digital Cross Connect systems; _ network terminations; _ transmission equipment used in the access network like xDSL. Power supply equipment. Such equipment includes: - central power plant; - end of suite power supplies; - uninterruptible power supplies; - stabilized AC power supplies; and - other dedicated telecommunication network power supplies; but excludes equipment which is uniquely associated with or integrated in other equipment. Supervisory equipment. Such equipment includes: - network management equipment; - operator access maintenance equipment; - traffic measurement systems; - line test units; - functional test units. The function of supervision may either be performed by independent equipment or form part of other telecommunication network equipment. If the function of supervision forms part of a telecommunication network equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission) during EMC testing. The environmental classification locations used in the present document refers to TR 101 651 [i.22]. The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures may have to be employed. General purpose equipment, which is used as a part of a telecommunication network, may be covered by the scope of other standards. For such equipment, if those other standards fully cover the requirements of the present document, no further assessment is necessary. Equipment for cabled distribution systems intended only for television and sound signals as defined in EN 50083-2 [3] and optical amplifiers as defined in ITU-T Recommendations G.661 [i.6] and G.662 [i.7] are outside the scope of the present document. Equipment may provide different functions, i.e. switching equipment may also provide transmission functions and transmission equipment may provide storage capabilities etc. All available functions of the EUT are to be tested.

The present document covers the EMC requirements for non-radio equipment intended to be used within a public telecommunications network, which provides telecommunications between Network Termination Points (NTPs) (i.e. excluding terminal equipment beyond the NTPs). Examples of such equipment are: Switching equipment. Such equipment includes: - local telephone exchanges; - remote switching concentrators; - international switches; - telex switches; - network packet switches; - base station controllers, radio network controllers; - network servers and gateways. Non-radio transmission equipment and ancillary equipment. Such equipment includes: - multiplexers; - line equipment and repeaters, e.g. equipment for: _ Synchronous Digital Hierarchy (SDH); _ Plesiochronous Digital Hierarchy (PDH); _ Asynchronous Transfer Mode (ATM); such as: _ Digital Cross Connect systems; _ network terminations; _ transmission equipment used in the access network like xDSL. Power supply equipment. Such equipment includes: - central power plant; - end of suite power supplies; - uninterruptible power supplies; - stabilized AC power supplies; and - other dedicated telecommunication network power supplies; but excludes equipment which is uniquely associated with or integrated in other equipment. Supervisory equipment. Such equipment includes: - network management equipment; - operator access maintenance equipment; - traffic measurement systems; - line test units; - functional test units. The function of supervision may either be performed by independent equipment or form part of other telecommunication network equipment. If the function of supervision forms part of a telecommunication network equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission) during EMC testing. The environmental classification locations used in the present document refers to TR 101 651 [i.22]. The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures may have to be employed. General purpose equipment, which is used as a part of a telecommunication network, may be covered by the scope of other standards. For such equipment, if those other standards fully cover the requirements of the present document, no further assessment is necessary. Equipment for cabled distribution systems intended only for television and sound signals as defined in EN 50083-2 [3] and optical amplifiers as defined in ITU-T Recommendations G.661 [i.6] and G.662 [i.7] are outside the scope of the present document. Equipment may provide different functions, i.e. switching equipment may also provide transmission functions and transmission equipment may provide storage capabilities etc. All available functions of the EUT are to be tested.

SIST EN 300 386 V1.6.1:2012 is classified under the following ICS (International Classification for Standards) categories: 33.050.01 - Telecommunication terminal equipment in general; 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 300 386 V1.6.1:2012 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EU, 2014/30/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 300 386 V1.6.1:2012 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


Final draft ETSI EN 300 386 V1.6.1 (2012-04)

Harmonized European Standard
Electromagnetic compatibility
and Radio spectrum Matters (ERM);
Telecommunication network equipment;
ElectroMagnetic Compatibility (EMC) requirements

2 Final draft ETSI EN 300 386 V1.6.1 (2012-04)

Reference
REN/ERM-EMC-312
Keywords
EMC, network, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
http://portal.etsi.org/chaircor/ETSI_support.asp
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.

© European Telecommunications Standards Institute 2012.
All rights reserved.
TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
3 Final draft ETSI EN 300 386 V1.6.1 (2012-04)
Contents
Intellectual Property Rights . 6
Foreword . 6
1 Scope . 7
2 References . 8
2.1 Normative references . 8
2.2 Informative references . 10
3 Definitions and abbreviations . 12
3.1 Definitions . 12
3.2 Abbreviations . 14
4 Installation environment . 14
5 Immunity: test methods . 15
5.1 Electrostatic discharge . 15
5.2 Electrical fast transients/burst . 15
5.3 Surges . 15
5.3.1 Signal line ports . 15
5.3.2 AC power ports . 15
5.4 Immunity to continuous conducted signals . 16
5.4.1 Low frequency (≤ 150 kHz) . 16
5.4.2 Radio frequency (> 150 kHz) . 16
5.4.2.1 AC power port . 16
5.4.2.2 DC power port . 16
5.4.2.3 Signal line port . 16
5.5 Immunity to radiated electromagnetic fields . 16
5.6 Immunity to power supply disturbances: AC and DC power ports . 16
5.6.1 Test of immunity to low frequency disturbances: AC power ports . 16
5.6.2 Test of immunity to low frequency disturbances: DC power ports . 16
6 Emission: test methods . 17
6.1 AC power port . 17
6.2 DC power port . 17
6.3 Telecommunication Port . 17
6.4 Radiated emission. 17
7 Test levels and limits . 18
7.1 Emission . 18
7.1.1 Enclosure port, Radiated electromagnetic field emissions . 18
7.1.2 AC ports . 18
7.1.2.1 Conducted emissions . 18
7.1.2.2 Current harmonics . 18
7.1.2.3 Voltage fluctuations . 18
7.1.3 DC ports, Conducted emissions . 18
7.1.4 Telecommunication ports, Conducted emissions . 18
7.2 Immunity . 19
7.2.1 Equipment operating in telecommunication centres . 19
7.2.1.1 Telecommunication centres, enclosure port . 19
7.2.1.2 Telecommunication centres, ports for outdoor signal lines . 20
7.2.1.3 Telecommunication centres, ports for indoor signal lines . 21
7.2.1.4 Telecommunication centres, AC power ports . 22
7.2.1.5 Telecommunication centres, DC power ports . 22
7.2.2 Equipment operating in locations other than telecommunication centres . 23
7.2.2.1 Other than telecommunication centres, enclosure port . 23
7.2.2.2 Other than telecommunication centres, ports for outdoor signal lines . 24
7.2.2.3 Other than telecommunication centres, ports for indoor signal lines . 25
7.2.2.4 Other than telecommunication centres, AC power ports . 26
ETSI
4 Final draft ETSI EN 300 386 V1.6.1 (2012-04)
7.2.2.5 Other than telecommunication centres, DC power ports . 27
8 General test configuration . 28
9 General operational conditions during testing . 28
9.1 Equipment configuration . 28
9.2 Operation of multimedia network equipment . 29
10 General immunity conditions . 29
10.1 General performance criteria . 29
11 Switching equipment specific requirements . 30
11.1 Test configuration. 30
11.2 Operational conditions . 31
11.2.1 Emission . 32
11.2.2 Immunity . 32
11.3 Specific immunity performance criteria . 32
11.3.1 Digital port performance criteria . 32
11.3.1.1 Performance criterion A (continuous phenomena) . 32
11.3.1.2 Performance criterion B (transient phenomena). 32
11.3.1.3 Performance criterion C (interruptions) . 32
11.3.2 Analogue port performance criteria . 33
11.3.2.1 Performance criterion A (continuous phenomena) . 33
11.3.2.2 Performance criterion B (transient phenomena). 33
11.3.2.3 Performance criterion C (interruptions) . 33
12 Transmission equipment specific requirements . 33
12.1 Test configuration. 33
12.2 Operational conditions . 34
12.2.1 Emission . 34
12.2.2 Immunity . 34
12.3 Specific immunity performance criteria . 34
12.3.1 Digital signal ports . 34
12.3.1.1 Performance criterion A (continuous phenomena) . 35
12.3.1.2 Performance criterion B (transient phenomena). 35
12.3.1.3 Performance criterion C (interruptions) . 35
12.3.2 Analogue voice frequency signal ports . 35
12.3.2.1 Performance criterion A (continuous phenomena) . 35
12.3.2.2 Performance criterion B (transient phenomena). 35
12.3.3 SDH and PDH interfaces . 35
12.3.3.1 Tributary and aggregate interfaces . 35
12.3.4 ISDN interfaces . 36
12.3.4.1 Primary rate access ISDN interfaces . 36
12.3.4.2 Network termination NT1 for ISDN "U" interfaces . 36
12.3.4.3 Basic access ISDN interfaces . 36
12.3.5 Analogue interfaces . 36
12.3.5.1 Trunk interfaces and leased line interfaces . 36
12.3.5.2 Subscriber interfaces . 36
12.3.6 V.10, V.11, V.24, V.28, V.36, X.24 and similar V.- and X.- series interfaces . 36
12.3.7 Ethernet and packet-data interfaces . 36
12.3.7.1 Performance criterion A (continuous phenomena) . 36
12.3.7.2 Performance criterion B (transient phenomena). 36
12.3.8 Service and maintenance interfaces . 36
12.3.9 Synchronization interfaces . 37
12.3.9.1 Performance criterion A (continuous phenomena) . 37
12.3.9.2 Performance criterion B (transient phenomena). 37
12.3.10 Remote alarm interfaces . 37
12.3.10.1 Performance criterion A (continuous phenomena) . 37
12.3.10.2 Performance criterion B (transient phenomena). 37
12.4 Digital Subscriber Line (DSL) Access Systems . 37
12.4.1 Test configuration . 37
12.4.2 Operational conditions . 38
12.4.3 Immunity . 38
12.4.4 Specific Immunity performance criteria . 38
ETSI
5 Final draft ETSI EN 300 386 V1.6.1 (2012-04)
12.4.4.1 Performance Criteria A (continuous phenomena) . 39
12.4.4.2 Performance Criteria B (transient phenomena) . 39
12.4.4.3 Performance Criteria C (interruptions). 39
13 Power supply equipment specific conditions . 39
13.1 Test configuration. 39
13.2 Operational conditions . 40
13.2.1 Emission . 40
13.2.2 Immunity . 40
13.3 Specific immunity performance criteria . 41
13.3.1 Alternating current secondary interface . 41
13.3.1.1 Performance criterion A (continuous phenomena) . 41
13.3.1.2 Performance criterion B (transient phenomena). 41
13.3.2 Direct current secondary interface . 42
13.3.2.1 Performance criterion A (continuous phenomena) . 42
13.3.2.2 Performance criterion B (transient phenomena). 42
13.3.3 Control/signal interface . 42
13.3.4 Tertiary supply interface . 42
14 Supervisory equipment specific conditions . 42
14.1 Test configuration. 42
14.2 Operational conditions . 43
14.3 Specific immunity performance criteria . 43
14.3.1 Performance criterion A (continuous phenomena) . 43
14.3.2 Performance criterion B (transient phenomena) . 43
Annex A (normative): Surges: test method for ports of signal lines remaining within the
building . 44
A.1 Test set-up for signal ports . 44
Annex B (informative): Evaluation of test results . 46
Annex C (informative): Guidance on EMC performance requirements and methods of
measurement for RF ports (in the sense of EN 50083 series) of
multimedia network equipment . 48
Annex D (informative): Bibliography . 49
History . 50

ETSI
6 Final draft ETSI EN 300 386 V1.6.1 (2012-04)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://ipr.etsi.org).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This final draft Harmonized European Standard (EN) has been produced by ETSI Technical Committee
Electromagnetic compatibility and Radio spectrum Matters (ERM), and is now submitted for the ETSI standards One-
step Approval Procedure.
The present document has been produced by ETSI in response to a mandate from the European Commission issued
under Directive 98/34/EC [i.23] as amended by Directive 98/48/EC [i.30].
The present document is intended to become a Harmonized Standard, the reference of which will be published in the
Official Journal of the European Communities referencing the Council Directive on the approximation of the laws of
the Member States relating to electromagnetic compatibility ("the EMC Directive") (2004/108/EC [i.24]).

Proposed national transposition dates
Date of latest announcement of this EN (doa): 3 months after ETSI publication
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 6 months after doa
Date of withdrawal of any conflicting National Standard (dow): 36 months after doa

ETSI
7 Final draft ETSI EN 300 386 V1.6.1 (2012-04)
1 Scope
The present document covers the EMC requirements for non-radio equipment intended to be used within a public
telecommunications network, which provides telecommunications between Network Termination Points (NTPs)
(i.e. excluding terminal equipment beyond the NTPs). Examples of such equipment are:
• Switching equipment. Such equipment includes:
- local telephone exchanges;
- remote switching concentrators;
- international switches;
- telex switches;
- network packet switches;
- base station controllers, radio network controllers;
- network servers and gateways.
• Non-radio transmission equipment and ancillary equipment. Such equipment includes:
- multiplexers;
- line equipment and repeaters, e.g. equipment for:
� Synchronous Digital Hierarchy (SDH);
� Plesiochronous Digital Hierarchy (PDH);
� Asynchronous Transfer Mode (ATM);
such as:
� Digital Cross Connect systems;
� network terminations;
� transmission equipment used in the access network like xDSL.
• Power supply equipment. Such equipment includes:
- central power plant;
- end of suite power supplies;
- uninterruptible power supplies;
- stabilized AC power supplies; and
- other dedicated telecommunication network power supplies;
but excludes equipment which is uniquely associated with or integrated in other equipment.
ETSI
8 Final draft ETSI EN 300 386 V1.6.1 (2012-04)
• Supervisory equipment. Such equipment includes:
- network management equipment;
- operator access maintenance equipment;
- traffic measurement systems;
- line test units;
- functional test units.
The function of supervision may either be performed by independent equipment or form part of other
telecommunication network equipment. If the function of supervision forms part of a telecommunication network
equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission)
during EMC testing.
The environmental classification locations used in the present document refers to TR 101 651 [i.22].
The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus
covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any
location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance
may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures
may have to be employed.
General purpose equipment, which is used as a part of a telecommunication network, may be covered by the scope of
other standards. For such equipment, if those other standards fully cover the requirements of the present document, no
further assessment is necessary. Equipment for cabled distribution systems intended only for television and sound
signals as defined in EN 50083-2 [3] and optical amplifiers as defined in ITU-T Recommendations G.661 [i.6] and
G.662 [i.7] are outside the scope of the present document.
Equipment may provide different functions, i.e. switching equipment may also provide transmission functions and
transmission equipment may provide storage capabilities etc. All available functions of the EUT are to be tested.
2 References
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
reference document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee
their long term validity.
2.1 Normative references
The following referenced documents are necessary for the application of the present document.
[1] CENELEC EN 55016-1-2 (-2004 + Amendment 1: 2005 + Amendment 2: 2006): "Specification
for radio disturbance and immunity measuring apparatus and methods -- Part 1-2: Radio
disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances".
[2] Void.
[3] CENELEC EN 50083-2 (2006): "Cable networks for television signals, sound signals and
interactive services -- Part 2: Electromagnetic compatibility for equipment".
[4] CENELEC EN 55022 (2010): "Information technology equipment - Radio disturbance
characteristics - Limits and methods of measurement".
ETSI
9 Final draft ETSI EN 300 386 V1.6.1 (2012-04)
[5] CENELEC EN 61000-3-2 (2006 + Amendment 1: 2009 + Amendment 2: 2009): "Electromagnetic
compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input
current <= 16 A per phase)".
[6] CENELEC EN 61000-3-3 (2008): "Electromagnetic compatibility (EMC) -- Part 3-3: Limits -
Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply
systems, for equipment with rated current <= 16 A per phase and not subject to conditional
connection".
[7] CENELEC EN 61000-3-11 (2000): "Electromagnetic compatibility (EMC) -- Part 3-11: Limits -
Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply
systems - Equipment with rated current <= 75 A and subject to conditional connection".
[8] CENELEC EN 61000-3-12 (2011): "Electromagnetic compatibility (EMC) -- Part 3-12: Limits -
Limits for harmonic currents produced by equipment connected to public low-voltage systems
with input current > 16 A and <= 75 A per phase".
[9] CENELEC EN 61000-4-2 (2009): "Electromagnetic compatibility (EMC) -- Part 4-2: Testing and
measurement techniques - Electrostatic discharge immunity test".
[10] CENELEC EN 61000-4-3 (2006 + Amendment 1: 2008 + Amendment 2: 2010 + Interpretation
Sheet: 2009 ): "Electromagnetic compatibility (EMC) -- Part 4-3: Testing and measurement
techniques - Radiated, radio-frequency, electromagnetic field immunity test".
[11] CENELEC EN 61000-4-4 (2004 + Amendment 1: 2010): "Electromagnetic compatibility (EMC) -
- Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test".
[12] CENELEC EN 61000-4-5 (2006): "Electromagnetic compatibility (EMC) -- Part 4-5: Testing and
measurement techniques - Surge immunity test".
[13] CENELEC EN 61000-4-6 (2009): "Electromagnetic compatibility (EMC) -- Part 4-6: Testing and
measurement techniques - Immunity to conducted disturbances, induced by radio-frequency
fields".
[14] CENELEC EN 61000-4-11 (2004): "Electromagnetic compatibility (EMC) -- Part 4-11: Testing
and measurement techniques - Voltage dips, short interruptions and voltage variations immunity
tests".
[15] ETSI ETS 300 132-1 (1996): "Equipment Engineering (EE); Power supply interface at the input to
telecommunications equipment; Part 1: Operated by alternating current (ac) derived from direct
current (dc) sources".
[16] ETSI EN 300 132-2 (2011): "Environmental Engineering (EE); Power supply interface at the input
to telecommunications and datacom (ICT) equipment; Part 2: Operated by -48 V direct current
(dc)".
[17] IEC 60050-161 (1990): "International Electrotechnical Vocabulary. Chapter 161: Electromagnetic
compatibility".
[18] IEC 60050-714 (1992): "International Electrotechnical Vocabulary - Chapter 714: Switching and
signalling in telecommunications".
[19] ETSI EN 300 127 (1999): "Electromagnetic compatibility and Radio spectrum Matters (ERM);
Radiated emission testing of physically large telecommunication systems".
[20] ITU-T Recommendation O.41 (1994): "Psophometer for use on telephone-type circuits".
[21] ITU-T Recommendation G.996.1 (2001 + Amendment 1: 2003): "Test procedures for digital
subscriber line (DSL) transceivers".
[22] ETSI TS 101 135 (2000): "Transmission and Multiplexing (TM); High bit-rate Digital Subscriber
Line (HDSL) transmission systems on metallic local lines; HDSL core specification and
applications for combined ISDN-BA and 2 048 kbit/s transmission".
ETSI
10 Final draft ETSI EN 300 386 V1.6.1 (2012-04)
[23] ETSI TS 101 524-1 (2000): "Transmission and Multiplexing (TM); Access transmission system on
metallic access cables; Symmetrical single pair high bitrate Digital Subscriber Line (SDSL);
Part 1: Functional requirements".
[24] ETSI TS 101 270-1 (2005): "Transmission and Multiplexing (TM); Access transmission systems
on metallic access cables; Very high speed Digital Subscriber Line (VDSL); Part 1: Functional
requirements".
[25] ITU-T Recommendation G.992.1 (1999 + Annex H: 2000 + Corrigendum 1: 2001 +
Corrigendum 2: 2002 + Amendment 1: 2003 + Corrigendum of Amendment 1: 2003):
"Asymmetric digital subscriber line (ADSL) transceivers".
[26] ITU-T Recommendation G.992.3 (2009 + Corrigendum 1: 2009 + Amendment 1: 2010 +
Amendment 2: 2010 + Amendment 3: 2010 + Corrigendum 2: 2011 + Amendment 4: 2011):
"Asymmetric digital subscriber line transceivers 2 (ADSL2)".
[27] ITU-T Recommendation G.992.5 (2009 + Corrigendum 1: 2010): "Asymmetric digital subscriber
line 2 transceivers (ADSL2) - Extended bandwidth ADSL2 (ADSL2plus)".
2.2 Informative references
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] ETSI EN 300 011-1 (2000): "Integrated Services Digital Network (ISDN); Primary rate User
Network Interface (UNI); Part 1: Layer 1 specification".
[i.2] ETSI EN 300 012-1 (2000): "Integrated Services Digital Network (ISDN); Basic User-Network
Interface (UNI); Part 1: Layer 1 specification".
[i.3] ETSI EN 300 166 (2001): "Transmission and Multiplexing (TM); Physical and electrical
characteristics of hierarchical digital interfaces for equipment using the 2 048 kbit/s - based
plesiochronous or synchronous digital hierarchies".
[i.4] ETSI ETS 300 232 (1993 + Amendment 1: 1996): "Transmission and Multiplexing (TM); Optical
interfaces for equipments and systems relating to the Synchronous Digital Hierarchy (SDH)
[ITU-T Recommendation G.957 (1995), modified]".
[i.5] ISO/IEC 8802-3 (2000): "Information technology - Telecommunications and information
exchange between systems - Local and metropolitan area networks - Specific requirements - Part
3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical
layer specifications".
[i.6] ITU-T Recommendation G.661 (2007): "Definition and test methods for the relevant generic
parameters of optical amplifier devices and subsystems".
[i.7] ITU-T Recommendation G.662 (2005): "Generic characteristics of optical amplifier devices and
subsystems".
[i.8] ITU-T Recommendation G.712 (2001): "Transmission performance characteristics of pulse code
modulation channels".
[i.9] ITU-T Recommendation G.812 (2004): "Timing requirements of slave clocks suitable for use as
node clocks in synchronization networks".
[i.10] ITU-T Recommendation G.813 (2003): "Timing characteristics of SDH equipment slave clocks
(SEC)".
[i.11] Void.
[i.12] ITU-T Recommendation G.961 (1993 + Erratum 1: 2000): "Digital transmission system on
metallic local lines for ISDN basic rate access".
ETSI
11 Final draft ETSI EN 300 386 V1.6.1 (2012-04)
[i.13] ITU-T Recommendation O.150 (1996 + Corrigendum 1: 2002): "General requirements for
instrumentation for performance measurements on digital transmission equipment".
[i.14] ITU-T Recommendation Q.552 (2001): "Transmission characteristics at 2-wire analogue interfaces
of digital exchanges".
[i.15] ITU-T Recommendation V.10 (1993): "Electrical characteristics for unbalanced double-current
interchange circuits operating at data signalling rates nominally up to 100 kbit/s".
[i.16] ITU-T Recommendation V.11 (1996): "Electrical characteristics for balanced double-current
interchange circuits operating at data signalling rates up to 10 Mbit/s".
[i.17] ITU-T Recommendation V.24 (2000): "List of definitions for interchange circuits between Data
Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE)".
[i.18] ITU-T Recommendation V.28 (1993): "Electrical characteristics for unbalanced double-current
interchange circuits".
[i.19] ITU-T Recommendation V.36 (1988): "Modems for synchronous data transmission using
60-108 kHz group band circuits".
[i.20] ITU-T Recommendation X.24 (1988): "List of definitions for interchange circuits between Data
Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE) on public data
networks".
[i.21] ITU-T Recommendation X.25 (1996 + Corrigendum 1: 1998): "Interface between Data Terminal
Equipment (DTE) and Data Circuit-terminating Equipment (DCE) for terminals operating in the
packet mode and connected to public data networks by dedicated circuit".
[i.22] ETSI TR 101 651 (1999): "Electromagnetic compatibility and radio spectrum matters (ERM);
Classification of the electromagnetic environment conditions for equipment in telecommunication
networks".
[i.23] Directive 98/34/EC of the European Parliament and of the Council of 22 June 1998 laying down a
procedure for the provision of information in the field of technical standards and regulations (EMC
Directive).
[i.24] Council Directive 2004/108/EC of 15 December 2004 on the approximation of the laws of the
Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC
(EMC Directive).
[i.25] ITU-T Recommendation G.783 (2006 + Erratum 1: 2006 + Amendment 1: 2008 + Amendment 2:
2010): "Characteristics of synchronous digital hierarchy (SDH) equipment functional blocks".
[i.26] ITU-T Recommendation G.798 (2010 + Corrigendum 1: 2011 + Amendment 1: 2011):
"Characteristics of optical transport network hierarchy equipment functional blocks".
[i.27] Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio
equipment and telecommunications terminal equipment and the mutual recognition of their
conformity (R&TTE Directive).
[i.28] IEEE 1284 (2000): "IEEE Standard Signalling Method for a Bidirectional Parallel Peripheral
Interface for Personal Computers".
[i.29] IEEE 1394 (2008): "IEEE Standard for High Performance Serial Bus Bridges".
[i.30] Directive 98/48/EC of the European Parliament and of the Council of 20 July 1998 amending
Directive 98/34/EC laying down a procedure for the provision of information in the field of
technical standards and regulations.
ETSI
12 Final draft ETSI EN 300 386 V1.6.1 (2012-04)
3 Definitions and abbreviations
3.1 Definitions
For the purposes of the present document, the terms and definitions given in IEC 60050-161 [17] and the following
apply:
NOTE: The definitions taken from IEC 60050-161 [17] have reference in parentheses.
AC secondary interface: output port of an AC power supply
AC secondary voltage: output of the AC power supply at the AC secondary interface
NOTE: The AC secondary voltage may be either:
- a stabilized AC supply derived from a DC primary supply (e.g. where the power supply is an
inverter); or
- derived from the AC primary supply (e.g. a stabilized power supply used where the quality of the
primary supply is not sufficient to feed telecommunication equipment).
burst (161-02-07): sequence of a limited number of distinct pulses or an oscillation of limited duration
connection: temporary association of transmission channels or telecommunication circuits, switching or other
functional units set up to provide for the transfer of information between two or more points in a telecommunication
network (IEC 60050-714 [18])
continuous disturbance (161-02-11): electromagnetic disturbance the effects of which on a particular device or
equipment cannot be resolved into a succession of distinct effects
DC secondary interface: output port of a DC power supply
DC secondary voltage: output of the DC power supply at the DC secondary interface
NOTE: The DC secondary voltage may be derived from the AC primary supply with or without a buffer battery.
duration (of a voltage change) (161-08-03): interval of time for the voltage to increase or decrease from the initial
value to the final value
duration (of a pulse): interval of time between the instants at which the instantaneous value of a pulse reaches 50 % of
the pulse magnitude for the first and last time
enclosure port: physical boundary of the Equipment Under Test (EUT) through which electromagnetic fields may
emanate or on which they may impinge
environment, environmental conditions: electromagnetic conditions external to the equipment, to which it is
subjected at a certain time
NOTE: The environmental conditions comprise a combination of single environmental parameters and their
severity.
environmental parameters: present one or more properties of the electromagnetic environment
immunity (to a disturbance) (161-01-20): ability of a device, equipment or system to perform without degradation in
the presence of an electromagnetic disturbance
impulsive disturbance (161-02-09): electromagnetic disturbance which, when incident on a particular device or
equipment, manifests itself as a succession of distinct pulses or transients
interface "A": terminals at which a power supply is connected to the telecommunications equipment
multimedia network equipment: multimedia network equipment containing broadcast and telecommunication
functions
ETSI
13 Final draft ETSI EN 300 386 V1.6.1 (2012-04)
nominal voltage: nominal value of voltage that designates the type of supply
normal service: service mode where telecommunications equipment operates within its specification
performance criterion: limits of acceptable behaviour of the equipment during and after the application of the
electromagnetic phenomenon
NOTE: Performance criteria A apply for continuous phenomena; performance criteria B and C apply for transient
phenomena; and performance criteria R apply for resistibility phenomena.
port: particular interface of the EUT with the external electromagnetic environment
power supply: power source (within the scope of the present document) to which telecommunications equipment is
intended to be connected
prim
...


Harmonized European Standard
Electromagnetic compatibility
and Radio spectrum Matters (ERM);
Telecommunication network equipment;
ElectroMagnetic Compatibility (EMC) requirements

2 ETSI EN 300 386 V1.6.1 (2012-09)

Reference
REN/ERM-EMC-312
Keywords
EMC, network, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
http://portal.etsi.org/chaircor/ETSI_support.asp
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.

© European Telecommunications Standards Institute 2012.
All rights reserved.
TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
3 ETSI EN 300 386 V1.6.1 (2012-09)
Contents
Intellectual Property Rights . 6
Foreword . 6
1 Scope . 7
2 References . 8
2.1 Normative references . 8
2.2 Informative references . 10
3 Definitions and abbreviations . 12
3.1 Definitions . 12
3.2 Abbreviations . 14
4 Installation environment . 14
5 Immunity: test methods . 15
5.1 Electrostatic discharge . 15
5.2 Electrical fast transients/burst . 15
5.3 Surges . 15
5.3.1 Signal line ports . 15
5.3.2 AC power ports . 15
5.4 Immunity to continuous conducted signals . 16
5.4.1 Low frequency (≤ 150 kHz) . 16
5.4.2 Radio frequency (> 150 kHz) . 16
5.4.2.1 AC power port . 16
5.4.2.2 DC power port . 16
5.4.2.3 Signal line port . 16
5.5 Immunity to radiated electromagnetic fields . 16
5.6 Immunity to power supply disturbances: AC and DC power ports . 16
5.6.1 Test of immunity to low frequency disturbances: AC power ports . 16
5.6.2 Test of immunity to low frequency disturbances: DC power ports . 16
6 Emission: test methods . 17
6.1 AC power port . 17
6.2 DC power port . 17
6.3 Telecommunication Port . 17
6.4 Radiated emission. 17
7 Test levels and limits . 18
7.1 Emission . 18
7.1.1 Enclosure port, Radiated electromagnetic field emissions . 18
7.1.2 AC ports . 18
7.1.2.1 Conducted emissions . 18
7.1.2.2 Current harmonics . 18
7.1.2.3 Voltage fluctuations . 18
7.1.3 DC ports, Conducted emissions . 18
7.1.4 Telecommunication ports, Conducted emissions . 18
7.2 Immunity . 19
7.2.1 Equipment operating in telecommunication centres . 19
7.2.1.1 Telecommunication centres, enclosure port . 19
7.2.1.2 Telecommunication centres, ports for outdoor signal lines . 20
7.2.1.3 Telecommunication centres, ports for indoor signal lines . 21
7.2.1.4 Telecommunication centres, AC power ports . 22
7.2.1.5 Telecommunication centres, DC power ports . 22
7.2.2 Equipment operating in locations other than telecommunication centres . 23
7.2.2.1 Other than telecommunication centres, enclosure port . 23
7.2.2.2 Other than telecommunication centres, ports for outdoor signal lines . 24
7.2.2.3 Other than telecommunication centres, ports for indoor signal lines . 25
7.2.2.4 Other than telecommunication centres, AC power ports . 26
ETSI
4 ETSI EN 300 386 V1.6.1 (2012-09)
7.2.2.5 Other than telecommunication centres, DC power ports . 27
8 General test configuration . 28
9 General operational conditions during testing . 28
9.1 Equipment configuration . 28
9.2 Operation of multimedia network equipment . 29
10 General immunity conditions . 29
10.1 General performance criteria . 29
11 Switching equipment specific requirements . 30
11.1 Test configuration. 30
11.2 Operational conditions . 31
11.2.1 Emission . 32
11.2.2 Immunity . 32
11.3 Specific immunity performance criteria . 32
11.3.1 Digital port performance criteria . 32
11.3.1.1 Performance criterion A (continuous phenomena) . 32
11.3.1.2 Performance criterion B (transient phenomena). 32
11.3.1.3 Performance criterion C (interruptions) . 32
11.3.2 Analogue port performance criteria . 33
11.3.2.1 Performance criterion A (continuous phenomena) . 33
11.3.2.2 Performance criterion B (transient phenomena). 33
11.3.2.3 Performance criterion C (interruptions) . 33
12 Transmission equipment specific requirements . 33
12.1 Test configuration. 33
12.2 Operational conditions . 34
12.2.1 Emission . 34
12.2.2 Immunity . 34
12.3 Specific immunity performance criteria . 34
12.3.1 Digital signal ports . 34
12.3.1.1 Performance criterion A (continuous phenomena) . 35
12.3.1.2 Performance criterion B (transient phenomena). 35
12.3.1.3 Performance criterion C (interruptions) . 35
12.3.2 Analogue voice frequency signal ports . 35
12.3.2.1 Performance criterion A (continuous phenomena) . 35
12.3.2.2 Performance criterion B (transient phenomena). 35
12.3.3 SDH and PDH interfaces . 35
12.3.3.1 Tributary and aggregate interfaces . 35
12.3.4 ISDN interfaces . 36
12.3.4.1 Primary rate access ISDN interfaces . 36
12.3.4.2 Network termination NT1 for ISDN "U" interfaces . 36
12.3.4.3 Basic access ISDN interfaces . 36
12.3.5 Analogue interfaces . 36
12.3.5.1 Trunk interfaces and leased line interfaces . 36
12.3.5.2 Subscriber interfaces . 36
12.3.6 V.10, V.11, V.24, V.28, V.36, X.24 and similar V.- and X.- series interfaces . 36
12.3.7 Ethernet and packet-data interfaces . 36
12.3.7.1 Performance criterion A (continuous phenomena) . 36
12.3.7.2 Performance criterion B (transient phenomena). 36
12.3.8 Service and maintenance interfaces . 36
12.3.9 Synchronization interfaces . 37
12.3.9.1 Performance criterion A (continuous phenomena) . 37
12.3.9.2 Performance criterion B (transient phenomena). 37
12.3.10 Remote alarm interfaces . 37
12.3.10.1 Performance criterion A (continuous phenomena) . 37
12.3.10.2 Performance criterion B (transient phenomena). 37
12.4 Digital Subscriber Line (DSL) Access Systems . 37
12.4.1 Test configuration . 37
12.4.2 Operational conditions . 38
12.4.3 Immunity . 38
12.4.4 Specific Immunity performance criteria . 38
ETSI
5 ETSI EN 300 386 V1.6.1 (2012-09)
12.4.4.1 Performance Criteria A (continuous phenomena) . 39
12.4.4.2 Performance Criteria B (transient phenomena) . 39
12.4.4.3 Performance Criteria C (interruptions). 39
13 Power supply equipment specific conditions . 39
13.1 Test configuration. 39
13.2 Operational conditions . 40
13.2.1 Emission . 40
13.2.2 Immunity . 40
13.3 Specific immunity performance criteria . 41
13.3.1 Alternating current secondary interface . 41
13.3.1.1 Performance criterion A (continuous phenomena) . 41
13.3.1.2 Performance criterion B (transient phenomena). 41
13.3.2 Direct current secondary interface . 42
13.3.2.1 Performance criterion A (continuous phenomena) . 42
13.3.2.2 Performance criterion B (transient phenomena). 42
13.3.3 Control/signal interface . 42
13.3.4 Tertiary supply interface . 42
14 Supervisory equipment specific conditions . 42
14.1 Test configuration. 42
14.2 Operational conditions . 43
14.3 Specific immunity performance criteria . 43
14.3.1 Performance criterion A (continuous phenomena) . 43
14.3.2 Performance criterion B (transient phenomena) . 43
Annex A (normative): Surges: test method for ports of signal lines remaining within the
building . 44
A.1 Test set-up for signal ports . 44
Annex B (informative): Evaluation of test results . 46
Annex C (informative): Guidance on EMC performance requirements and methods of
measurement for RF ports (in the sense of EN 50083 series) of
multimedia network equipment . 48
Annex D (informative): Bibliography . 49
History . 50

ETSI
6 ETSI EN 300 386 V1.6.1 (2012-09)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://ipr.etsi.org).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This Harmonized European Standard (EN) has been produced by ETSI Technical Committee Electromagnetic
compatibility and Radio spectrum Matters (ERM).
The present document has been produced by ETSI in response to a mandate from the European Commission issued
under Directive 98/34/EC [i.23] as amended by Directive 98/48/EC [i.30].
The present document is intended to become a Harmonized Standard, the reference of which will be published in the
Official Journal of the European Communities referencing the Council Directive on the approximation of the laws of
the Member States relating to electromagnetic compatibility ("the EMC Directive") (2004/108/EC [i.24]).

National transposition dates
Date of adoption of this EN: 10 August 2012
Date of latest announcement of this EN (doa): 30 November 2012
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 May 2013
Date of withdrawal of any conflicting National Standard (dow): 30 November 2015

ETSI
7 ETSI EN 300 386 V1.6.1 (2012-09)
1 Scope
The present document covers the EMC requirements for non-radio equipment intended to be used within a public
telecommunications network, which provides telecommunications between Network Termination Points (NTPs)
(i.e. excluding terminal equipment beyond the NTPs). Examples of such equipment are:
• Switching equipment. Such equipment includes:
- local telephone exchanges;
- remote switching concentrators;
- international switches;
- telex switches;
- network packet switches;
- base station controllers, radio network controllers;
- network servers and gateways.
• Non-radio transmission equipment and ancillary equipment. Such equipment includes:
- multiplexers;
- line equipment and repeaters, e.g. equipment for:
� Synchronous Digital Hierarchy (SDH);
� Plesiochronous Digital Hierarchy (PDH);
� Asynchronous Transfer Mode (ATM);
such as:
� Digital Cross Connect systems;
� network terminations;
� transmission equipment used in the access network like xDSL.
• Power supply equipment. Such equipment includes:
- central power plant;
- end of suite power supplies;
- uninterruptible power supplies;
- stabilized AC power supplies; and
- other dedicated telecommunication network power supplies;
but excludes equipment which is uniquely associated with or integrated in other equipment.
ETSI
8 ETSI EN 300 386 V1.6.1 (2012-09)
• Supervisory equipment. Such equipment includes:
- network management equipment;
- operator access maintenance equipment;
- traffic measurement systems;
- line test units;
- functional test units.
The function of supervision may either be performed by independent equipment or form part of other
telecommunication network equipment. If the function of supervision forms part of a telecommunication network
equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission)
during EMC testing.
The environmental classification locations used in the present document refers to TR 101 651 [i.22].
The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus
covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any
location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance
may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures
may have to be employed.
General purpose equipment, which is used as a part of a telecommunication network, may be covered by the scope of
other standards. For such equipment, if those other standards fully cover the requirements of the present document, no
further assessment is necessary. Equipment for cabled distribution systems intended only for television and sound
signals as defined in EN 50083-2 [3] and optical amplifiers as defined in ITU-T Recommendations G.661 [i.6] and
G.662 [i.7] are outside the scope of the present document.
Equipment may provide different functions, i.e. switching equipment may also provide transmission functions and
transmission equipment may provide storage capabilities etc. All available functions of the EUT are to be tested.
2 References
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
reference document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee
their long term validity.
2.1 Normative references
The following referenced documents are necessary for the application of the present document.
[1] CENELEC EN 55016-1-2 (-2004 + Amendment 1: 2005 + Amendment 2: 2006): "Specification
for radio disturbance and immunity measuring apparatus and methods -- Part 1-2: Radio
disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances".
[2] Void.
[3] CENELEC EN 50083-2 (2006): "Cable networks for television signals, sound signals and
interactive services -- Part 2: Electromagnetic compatibility for equipment".
[4] CENELEC EN 55022 (2010): "Information technology equipment - Radio disturbance
characteristics - Limits and methods of measurement".
ETSI
9 ETSI EN 300 386 V1.6.1 (2012-09)
[5] CENELEC EN 61000-3-2 (2006 + Amendment 1: 2009 + Amendment 2: 2009): "Electromagnetic
compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input
current <= 16 A per phase)".
[6] CENELEC EN 61000-3-3 (2008): "Electromagnetic compatibility (EMC) -- Part 3-3: Limits -
Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply
systems, for equipment with rated current <= 16 A per phase and not subject to conditional
connection".
[7] CENELEC EN 61000-3-11 (2000): "Electromagnetic compatibility (EMC) -- Part 3-11: Limits -
Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply
systems - Equipment with rated current <= 75 A and subject to conditional connection".
[8] CENELEC EN 61000-3-12 (2011): "Electromagnetic compatibility (EMC) -- Part 3-12: Limits -
Limits for harmonic currents produced by equipment connected to public low-voltage systems
with input current > 16 A and <= 75 A per phase".
[9] CENELEC EN 61000-4-2 (2009): "Electromagnetic compatibility (EMC) -- Part 4-2: Testing and
measurement techniques - Electrostatic discharge immunity test".
[10] CENELEC EN 61000-4-3 (2006 + Amendment 1: 2008 + Amendment 2: 2010 + Interpretation
Sheet: 2009 ): "Electromagnetic compatibility (EMC) -- Part 4-3: Testing and measurement
techniques - Radiated, radio-frequency, electromagnetic field immunity test".
[11] CENELEC EN 61000-4-4 (2004 + Amendment 1: 2010): "Electromagnetic compatibility (EMC) -
- Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test".
[12] CENELEC EN 61000-4-5 (2006): "Electromagnetic compatibility (EMC) -- Part 4-5: Testing and
measurement techniques - Surge immunity test".
[13] CENELEC EN 61000-4-6 (2009): "Electromagnetic compatibility (EMC) -- Part 4-6: Testing and
measurement techniques - Immunity to conducted disturbances, induced by radio-frequency
fields".
[14] CENELEC EN 61000-4-11 (2004): "Electromagnetic compatibility (EMC) -- Part 4-11: Testing
and measurement techniques - Voltage dips, short interruptions and voltage variations immunity
tests".
[15] ETSI ETS 300 132-1 (1996): "Equipment Engineering (EE); Power supply interface at the input to
telecommunications equipment; Part 1: Operated by alternating current (ac) derived from direct
current (dc) sources".
[16] ETSI EN 300 132-2 (2011): "Environmental Engineering (EE); Power supply interface at the input
to telecommunications and datacom (ICT) equipment; Part 2: Operated by -48 V direct current
(dc)".
[17] IEC 60050-161 (1990): "International Electrotechnical Vocabulary. Chapter 161: Electromagnetic
compatibility".
[18] IEC 60050-714 (1992): "International Electrotechnical Vocabulary - Chapter 714: Switching and
signalling in telecommunications".
[19] ETSI EN 300 127 (1999): "Electromagnetic compatibility and Radio spectrum Matters (ERM);
Radiated emission testing of physically large telecommunication systems".
[20] ITU-T Recommendation O.41 (1994): "Psophometer for use on telephone-type circuits".
[21] ITU-T Recommendation G.996.1 (2001 + Amendment 1: 2003): "Test procedures for digital
subscriber line (DSL) transceivers".
[22] ETSI TS 101 135 (2000): "Transmission and Multiplexing (TM); High bit-rate Digital Subscriber
Line (HDSL) transmission systems on metallic local lines; HDSL core specification and
applications for combined ISDN-BA and 2 048 kbit/s transmission".
ETSI
10 ETSI EN 300 386 V1.6.1 (2012-09)
[23] ETSI TS 101 524-1 (2000): "Transmission and Multiplexing (TM); Access transmission system on
metallic access cables; Symmetrical single pair high bitrate Digital Subscriber Line (SDSL);
Part 1: Functional requirements".
[24] ETSI TS 101 270-1 (2005): "Transmission and Multiplexing (TM); Access transmission systems
on metallic access cables; Very high speed Digital Subscriber Line (VDSL); Part 1: Functional
requirements".
[25] ITU-T Recommendation G.992.1 (1999 + Annex H: 2000 + Corrigendum 1: 2001 +
Corrigendum 2: 2002 + Amendment 1: 2003 + Corrigendum of Amendment 1: 2003):
"Asymmetric digital subscriber line (ADSL) transceivers".
[26] ITU-T Recommendation G.992.3 (2009 + Corrigendum 1: 2009 + Amendment 1: 2010 +
Amendment 2: 2010 + Amendment 3: 2010 + Corrigendum 2: 2011 + Amendment 4: 2011):
"Asymmetric digital subscriber line transceivers 2 (ADSL2)".
[27] ITU-T Recommendation G.992.5 (2009 + Corrigendum 1: 2010): "Asymmetric digital subscriber
line 2 transceivers (ADSL2) - Extended bandwidth ADSL2 (ADSL2plus)".
2.2 Informative references
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] ETSI EN 300 011-1 (2000): "Integrated Services Digital Network (ISDN); Primary rate User
Network Interface (UNI); Part 1: Layer 1 specification".
[i.2] ETSI EN 300 012-1 (2000): "Integrated Services Digital Network (ISDN); Basic User-Network
Interface (UNI); Part 1: Layer 1 specification".
[i.3] ETSI EN 300 166 (2001): "Transmission and Multiplexing (TM); Physical and electrical
characteristics of hierarchical digital interfaces for equipment using the 2 048 kbit/s - based
plesiochronous or synchronous digital hierarchies".
[i.4] ETSI ETS 300 232 (1993 + Amendment 1: 1996): "Transmission and Multiplexing (TM); Optical
interfaces for equipments and systems relating to the Synchronous Digital Hierarchy (SDH)
[ITU-T Recommendation G.957 (1995), modified]".
[i.5] ISO/IEC 8802-3 (2000): "Information technology - Telecommunications and information
exchange between systems - Local and metropolitan area networks - Specific requirements -
Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and
physical layer specifications".
[i.6] ITU-T Recommendation G.661 (2007): "Definition and test methods for the relevant generic
parameters of optical amplifier devices and subsystems".
[i.7] ITU-T Recommendation G.662 (2005): "Generic characteristics of optical amplifier devices and
subsystems".
[i.8] ITU-T Recommendation G.712 (2001): "Transmission performance characteristics of pulse code
modulation channels".
[i.9] ITU-T Recommendation G.812 (2004): "Timing requirements of slave clocks suitable for use as
node clocks in synchronization networks".
[i.10] ITU-T Recommendation G.813 (2003): "Timing characteristics of SDH equipment slave clocks
(SEC)".
[i.11] Void.
[i.12] ITU-T Recommendation G.961 (1993 + Erratum 1: 2000): "Digital transmission system on
metallic local lines for ISDN basic rate access".
ETSI
11 ETSI EN 300 386 V1.6.1 (2012-09)
[i.13] ITU-T Recommendation O.150 (1996 + Corrigendum 1: 2002): "General requirements for
instrumentation for performance measurements on digital transmission equipment".
[i.14] ITU-T Recommendation Q.552 (2001): "Transmission characteristics at 2-wire analogue interfaces
of digital exchanges".
[i.15] ITU-T Recommendation V.10 (1993): "Electrical characteristics for unbalanced double-current
interchange circuits operating at data signalling rates nominally up to 100 kbit/s".
[i.16] ITU-T Recommendation V.11 (1996): "Electrical characteristics for balanced double-current
interchange circuits operating at data signalling rates up to 10 Mbit/s".
[i.17] ITU-T Recommendation V.24 (2000): "List of definitions for interchange circuits between Data
Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE)".
[i.18] ITU-T Recommendation V.28 (1993): "Electrical characteristics for unbalanced double-current
interchange circuits".
[i.19] ITU-T Recommendation V.36 (1988): "Modems for synchronous data transmission using
60-108 kHz group band circuits".
[i.20] ITU-T Recommendation X.24 (1988): "List of definitions for interchange circuits between Data
Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE) on public data
networks".
[i.21] ITU-T Recommendation X.25 (1996 + Corrigendum 1: 1998): "Interface between Data Terminal
Equipment (DTE) and Data Circuit-terminating Equipment (DCE) for terminals operating in the
packet mode and connected to public data networks by dedicated circuit".
[i.22] ETSI TR 101 651 (1999): "Electromagnetic compatibility and radio spectrum matters (ERM);
Classification of the electromagnetic environment conditions for equipment in telecommunication
networks".
[i.23] Directive 98/34/EC of the European Parliament and of the Council of 22 June 1998 laying down a
procedure for the provision of information in the field of technical standards and regulations (EMC
Directive).
[i.24] Council Directive 2004/108/EC of 15 December 2004 on the approximation of the laws of the
Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC
(EMC Directive).
[i.25] ITU-T Recommendation G.783 (2006 + Erratum 1: 2006 + Amendment 1: 2008 + Amendment 2:
2010): "Characteristics of synchronous digital hierarchy (SDH) equipment functional blocks".
[i.26] ITU-T Recommendation G.798 (2010 + Corrigendum 1: 2011 + Amendment 1: 2011):
"Characteristics of optical transport network hierarchy equipment functional blocks".
[i.27] Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio
equipment and telecommunications terminal equipment and the mutual recognition of their
conformity (R&TTE Directive).
[i.28] IEEE 1284 (2000): "IEEE Standard Signalling Method for a Bidirectional Parallel Peripheral
Interface for Personal Computers".
[i.29] IEEE 1394 (2008): "IEEE Standard for High Performance Serial Bus Bridges".
[i.30] Directive 98/48/EC of the European Parliament and of the Council of 20 July 1998 amending
Directive 98/34/EC laying down a procedure for the provision of information in the field of
technical standards and regulations.
ETSI
12 ETSI EN 300 386 V1.6.1 (2012-09)
3 Definitions and abbreviations
3.1 Definitions
For the purposes of the present document, the terms and definitions given in IEC 60050-161 [17] and the following
apply:
NOTE: The definitions taken from IEC 60050-161 [17] have reference in parentheses.
AC secondary interface: output port of an AC power supply
AC secondary voltage: output of the AC power supply at the AC secondary interface
NOTE: The AC secondary voltage may be either:
- a stabilized AC supply derived from a DC primary supply (e.g. where the power supply is an
inverter); or
- derived from the AC primary supply (e.g. a stabilized power supply used where the quality of the
primary supply is not sufficient to feed telecommunication equipment).
burst (161-02-07): sequence of a limited number of distinct pulses or an oscillation of limited duration
connection: temporary association of transmission channels or telecommunication circuits, switching or other
functional units set up to provide for the transfer of information between two or more points in a telecommunication
network (IEC 60050-714 [18])
continuous disturbance (161-02-11): electromagnetic disturbance the effects of which on a particular device or
equipment cannot be resolved into a succession of distinct effects
DC secondary interface: output port of a DC power supply
DC secondary voltage: output of the DC power supply at the DC secondary interface
NOTE: The DC secondary voltage may be derived from the AC primary supply with or without a buffer battery.
duration (of a voltage change) (161-08-03): interval of time for the voltage to increase or decrease from the initial
value to the final value
duration (of a pulse): interval of time between the instants at which the instantaneous value of a pulse reaches 50 % of
the pulse magnitude for the first and last time
enclosure port: physical boundary of the Equipment Under Test (EUT) through which electromagnetic fields may
emanate or on which they may impinge
environment, environmental conditions: electromagnetic conditions external to the equipment, to which it is
subjected at a certain time
NOTE: The environmental conditions comprise a combination of single environmental parameters and their
severity.
environmental parameters: present one or more properties of the electromagnetic environment
immunity (to a disturbance) (161-01-20): ability of a device, equipment or system to perform without degradation in
the presence of an electromagnetic disturbance
impulsive disturbance (161-02-09): electromagnetic disturbance which, when incident on a particular device or
equipment, manifests itself as a succession of distinct pulses or transients
interface "A": terminals at which a power supply is connected to the telecommunications equipment
multimedia network equipment: multimedia network equipment containing broadcast and telecommunication
functions
ETSI
13 ETSI EN 300 386 V1.6.1 (2012-09)
nominal voltage: nominal value of voltage that designates the type of supply
normal service: service mode where telecommunications equipment operates within its specification
performance criterion: limits of acceptable behaviour of the equipment during and after the application of the
electromagnetic phenomenon
NOTE: Performance criteria A apply for continuous phenomena; performance criteria B and C apply for transient
phenomena; and performance criteria R apply for resistibility phenomena.
port: particular interface of the EUT with the external electromagnetic environment
power supply: power source (within the scope of the present document) to which telecommunications equipment is
intended to be connected
primary supply: public mains or a locally generated AC or DC supply
public telecommunications network: telecommunication network operated by an entity required to publish its
interface specifications under art. 4 of Direc
...


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Elektromagnetna združljivost in zadeve v zvezi z radijskim spektrom (ERM) - Oprema za telekomunikacijsko omrežje - Zahteve za elektromagnetno združljivost (EMC)Electromagnetic compatibility and Radio spectrum Matters (ERM) - Telecommunication network equipment - ElectroMagnetic Compatibility (EMC) requirements33.100.01Elektromagnetna združljivost na splošnoElectromagnetic compatibility in general33.050.01Telekomunikacijska terminalska oprema na splošnoTelecommunication terminal equipment in generalICS:Ta slovenski standard je istoveten z:EN 300 386 Version 1.6.1SIST EN 300 386 V1.6.1:2012en01-oktober-2012SIST EN 300 386 V1.6.1:2012SLOVENSKI
STANDARD
Harmonized European Standard SIST EN 300 386 V1.6.1:2012

ETSI ETSI EN 300 386 V1.6.1 (2012-09) 2
Reference REN/ERM-EMC-312 Keywords EMC, network, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C Association à but non lucratif enregistrée à la Sous-Préfecture de Grasse (06) N° 7803/88
Important notice Individual copies of the present document can be downloaded from: http://www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http://portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http://portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2012. All rights reserved.
DECTTM, PLUGTESTSTM, UMTSTM and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association. SIST EN 300 386 V1.6.1:2012

ETSI ETSI EN 300 386 V1.6.1 (2012-09) 3 Contents Intellectual Property Rights . 6 Foreword . 6 1 Scope . 7 2 References . 8 2.1 Normative references . 8 2.2 Informative references . 10 3 Definitions and abbreviations . 12 3.1 Definitions . 12 3.2 Abbreviations . 14 4 Installation environment . 14 5 Immunity: test methods . 15 5.1 Electrostatic discharge . 15 5.2 Electrical fast transients/burst . 15 5.3 Surges . 15 5.3.1 Signal line ports . 15 5.3.2 AC power ports . 15 5.4 Immunity to continuous conducted signals . 16 5.4.1 Low frequency (≤ 150 kHz) . 16 5.4.2 Radio frequency (> 150 kHz) . 16 5.4.2.1 AC power port . 16 5.4.2.2 DC power port . 16 5.4.2.3 Signal line port . 16 5.5 Immunity to radiated electromagnetic fields . 16 5.6 Immunity to power supply disturbances: AC and DC power ports . 16 5.6.1 Test of immunity to low frequency disturbances: AC power ports . 16 5.6.2 Test of immunity to low frequency disturbances: DC power ports . 16 6 Emission: test methods . 17 6.1 AC power port . 17 6.2 DC power port . 17 6.3 Telecommunication Port . 17 6.4 Radiated emission. 17 7 Test levels and limits . 18 7.1 Emission . 18 7.1.1 Enclosure port, Radiated electromagnetic field emissions . 18 7.1.2 AC ports . 18 7.1.2.1 Conducted emissions . 18 7.1.2.2 Current harmonics . 18 7.1.2.3 Voltage fluctuations . 18 7.1.3 DC ports, Conducted emissions . 18 7.1.4 Telecommunication ports, Conducted emissions . 18 7.2 Immunity . 19 7.2.1 Equipment operating in telecommunication centres . 19 7.2.1.1 Telecommunication centres, enclosure port . 19 7.2.1.2 Telecommunication centres, ports for outdoor signal lines . 20 7.2.1.3 Telecommunication centres, ports for indoor signal lines . 21 7.2.1.4 Telecommunication centres, AC power ports . 22 7.2.1.5 Telecommunication centres, DC power ports . 22 7.2.2 Equipment operating in locations other than telecommunication centres . 23 7.2.2.1 Other than telecommunication centres, enclosure port . 23 7.2.2.2 Other than telecommunication centres, ports for outdoor signal lines . 24 7.2.2.3 Other than telecommunication centres, ports for indoor signal lines . 25 7.2.2.4 Other than telecommunication centres, AC power ports . 26 SIST EN 300 386 V1.6.1:2012

ETSI ETSI EN 300 386 V1.6.1 (2012-09) 4 7.2.2.5 Other than telecommunication centres, DC power ports . 27 8 General test configuration . 28 9 General operational conditions during testing . 28 9.1 Equipment configuration . 28 9.2 Operation of multimedia network equipment . 29 10 General immunity conditions . 29 10.1 General performance criteria . 29 11 Switching equipment specific requirements . 30 11.1 Test configuration. 30 11.2 Operational conditions . 31 11.2.1 Emission . 32 11.2.2 Immunity . 32 11.3 Specific immunity performance criteria . 32 11.3.1 Digital port performance criteria . 32 11.3.1.1 Performance criterion A (continuous phenomena) . 32 11.3.1.2 Performance criterion B (transient phenomena). 32 11.3.1.3 Performance criterion C (interruptions) . 32 11.3.2 Analogue port performance criteria . 33 11.3.2.1 Performance criterion A (continuous phenomena) . 33 11.3.2.2 Performance criterion B (transient phenomena). 33 11.3.2.3 Performance criterion C (interruptions) . 33 12 Transmission equipment specific requirements . 33 12.1 Test configuration. 33 12.2 Operational conditions . 34 12.2.1 Emission . 34 12.2.2 Immunity . 34 12.3 Specific immunity performance criteria . 34 12.3.1 Digital signal ports . 34 12.3.1.1 Performance criterion A (continuous phenomena) . 35 12.3.1.2 Performance criterion B (transient phenomena). 35 12.3.1.3 Performance criterion C (interruptions) . 35 12.3.2 Analogue voice frequency signal ports . 35 12.3.2.1 Performance criterion A (continuous phenomena) . 35 12.3.2.2 Performance criterion B (transient phenomena). 35 12.3.3 SDH and PDH interfaces . 35 12.3.3.1 Tributary and aggregate interfaces . 35 12.3.4 ISDN interfaces . 36 12.3.4.1 Primary rate access ISDN interfaces . 36 12.3.4.2 Network termination NT1 for ISDN "U" interfaces . 36 12.3.4.3 Basic access ISDN interfaces . 36 12.3.5 Analogue interfaces . 36 12.3.5.1 Trunk interfaces and leased line interfaces . 36 12.3.5.2 Subscriber interfaces . 36 12.3.6 V.10, V.11, V.24, V.28, V.36, X.24 and similar V.- and X.- series interfaces . 36 12.3.7 Ethernet and packet-data interfaces . 36 12.3.7.1 Performance criterion A (continuous phenomena) . 36 12.3.7.2 Performance criterion B (transient phenomena). 36 12.3.8 Service and maintenance interfaces . 36 12.3.9 Synchronization interfaces . 37 12.3.9.1 Performance criterion A (continuous phenomena) . 37 12.3.9.2 Performance criterion B (transient phenomena). 37 12.3.10 Remote alarm interfaces . 37 12.3.10.1 Performance criterion A (continuous phenomena) . 37 12.3.10.2 Performance criterion B (transient phenomena). 37 12.4 Digital Subscriber Line (DSL) Access Systems . 37 12.4.1 Test configuration . 37 12.4.2 Operational conditions . 38 12.4.3 Immunity . 38 12.4.4 Specific Immunity performance criteria . 38 SIST EN 300 386 V1.6.1:2012

ETSI ETSI EN 300 386 V1.6.1 (2012-09) 5 12.4.4.1 Performance Criteria A (continuous phenomena) . 39 12.4.4.2 Performance Criteria B (transient phenomena) . 39 12.4.4.3 Performance Criteria C (interruptions). 39 13 Power supply equipment specific conditions . 39 13.1 Test configuration. 39 13.2 Operational conditions . 40 13.2.1 Emission . 40 13.2.2 Immunity . 40 13.3 Specific immunity performance criteria . 41 13.3.1 Alternating current secondary interface . 41 13.3.1.1 Performance criterion A (continuous phenomena) . 41 13.3.1.2 Performance criterion B (transient phenomena). 41 13.3.2 Direct current secondary interface . 42 13.3.2.1 Performance criterion A (continuous phenomena) . 42 13.3.2.2 Performance criterion B (transient phenomena). 42 13.3.3 Control/signal interface . 42 13.3.4 Tertiary supply interface . 42 14 Supervisory equipment specific conditions . 42 14.1 Test configuration. 42 14.2 Operational conditions . 43 14.3 Specific immunity performance criteria . 43 14.3.1 Performance criterion A (continuous phenomena) . 43 14.3.2 Performance criterion B (transient phenomena) . 43 Annex A (normative): Surges: test method for ports of signal lines remaining within the building . 44 A.1 Test set-up for signal ports . 44 Annex B (informative): Evaluation of test results . 46 Annex C (informative): Guidance on EMC performance requirements and methods of measurement for RF ports (in the sense of EN 50083 series) of multimedia network equipment . 48 Annex D (informative): Bibliography . 49 History . 50
ETSI ETSI EN 300 386 V1.6.1 (2012-09) 6 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http://ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Harmonized European Standard (EN) has been produced by ETSI Technical Committee Electromagnetic compatibility and Radio spectrum Matters (ERM). The present document has been produced by ETSI in response to a mandate from the European Commission issued under Directive 98/34/EC [i.23] as amended by Directive 98/48/EC [i.30]. The present document is intended to become a Harmonized Standard, the reference of which will be published in the Official Journal of the European Communities referencing the Council Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility ("the EMC Directive") (2004/108/EC [i.24]).
National transposition dates Date of adoption of this EN: 10 August 2012 Date of latest announcement of this EN (doa): 30 November 2012 Date of latest publication of new National Standard or endorsement of this EN (dop/e):
31 May 2013 Date of withdrawal of any conflicting National Standard (dow): 30 November 2015
ETSI ETSI EN 300 386 V1.6.1 (2012-09) 7 1 Scope The present document covers the EMC requirements for non-radio equipment intended to be used within a public telecommunications network, which provides telecommunications between Network Termination Points (NTPs) (i.e. excluding terminal equipment beyond the NTPs). Examples of such equipment are: • Switching equipment. Such equipment includes: - local telephone exchanges; - remote switching concentrators; - international switches; - telex switches; - network packet switches; - base station controllers, radio network controllers; - network servers and gateways. • Non-radio transmission equipment and ancillary equipment. Such equipment includes: - multiplexers; - line equipment and repeaters, e.g. equipment for:
Synchronous Digital Hierarchy (SDH);
Plesiochronous Digital Hierarchy (PDH);
Asynchronous Transfer Mode (ATM); such as:
Digital Cross Connect systems;
network terminations;
transmission equipment used in the access network like xDSL. • Power supply equipment. Such equipment includes: - central power plant; - end of suite power supplies; - uninterruptible power supplies; - stabilized AC power supplies; and - other dedicated telecommunication network power supplies; but excludes equipment which is uniquely associated with or integrated in other equipment. SIST EN 300 386 V1.6.1:2012

ETSI ETSI EN 300 386 V1.6.1 (2012-09) 8 • Supervisory equipment. Such equipment includes: - network management equipment; - operator access maintenance equipment; - traffic measurement systems; - line test units; - functional test units. The function of supervision may either be performed by independent equipment or form part of other telecommunication network equipment. If the function of supervision forms part of a telecommunication network equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission) during EMC testing. The environmental classification locations used in the present document refers to TR 101 651 [i.22]. The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures may have to be employed. General purpose equipment, which is used as a part of a telecommunication network, may be covered by the scope of other standards. For such equipment, if those other standards fully cover the requirements of the present document, no further assessment is necessary. Equipment for cabled distribution systems intended only for television and sound signals as defined in EN 50083-2 [3] and optical amplifiers as defined in ITU-T Recommendations G.661 [i.6] and G.662 [i.7] are outside the scope of the present document. Equipment may provide different functions, i.e. switching equipment may also provide transmission functions and transmission equipment may provide storage capabilities etc. All available functions of the EUT are to be tested. 2 References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the reference document (including any amendments) applies. Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference. NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity. 2.1 Normative references The following referenced documents are necessary for the application of the present document. [1] CENELEC EN 55016-1-2 (-2004 + Amendment 1: 2005 + Amendment 2: 2006): "Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-2: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances". [2] Void. [3] CENELEC EN 50083-2 (2006): "Cable networks for television signals, sound signals and interactive services -- Part 2: Electromagnetic compatibility for equipment". [4] CENELEC EN 55022 (2010): "Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement". SIST EN 300 386 V1.6.1:2012

ETSI ETSI EN 300 386 V1.6.1 (2012-09) 9 [5] CENELEC EN 61000-3-2 (2006 + Amendment 1: 2009 + Amendment 2: 2009): "Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase)". [6] CENELEC EN 61000-3-3 (2008): "Electromagnetic compatibility (EMC) -- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection". [7] CENELEC EN 61000-3-11 (2000): "Electromagnetic compatibility (EMC) -- Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current <= 75 A and subject to conditional connection". [8] CENELEC EN 61000-3-12 (2011): "Electromagnetic compatibility (EMC) -- Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and <= 75 A per phase". [9] CENELEC EN 61000-4-2 (2009): "Electromagnetic compatibility (EMC) -- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test". [10] CENELEC EN 61000-4-3 (2006 + Amendment 1: 2008 + Amendment 2: 2010 + Interpretation Sheet: 2009 ): "Electromagnetic compatibility (EMC) -- Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test". [11] CENELEC EN 61000-4-4 (2004 + Amendment 1: 2010): "Electromagnetic compatibility (EMC) -- Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test". [12] CENELEC EN 61000-4-5 (2006): "Electromagnetic compatibility (EMC) -- Part 4-5: Testing and measurement techniques - Surge immunity test". [13] CENELEC EN 61000-4-6 (2009): "Electromagnetic compatibility (EMC) -- Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields". [14] CENELEC EN 61000-4-11 (2004): "Electromagnetic compatibility (EMC) -- Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests". [15] ETSI ETS 300 132-1 (1996): "Equipment Engineering (EE); Power supply interface at the input to telecommunications equipment; Part 1: Operated by alternating current (ac) derived from direct current (dc) sources". [16] ETSI EN 300 132-2 (2011): "Environmental Engineering (EE); Power supply interface at the input to telecommunications and datacom (ICT) equipment; Part 2: Operated by -48 V direct current (dc)". [17] IEC 60050-161 (1990): "International Electrotechnical Vocabulary. Chapter 161: Electromagnetic compatibility". [18] IEC 60050-714 (1992): "International Electrotechnical Vocabulary - Chapter 714: Switching and signalling in telecommunications". [19] ETSI EN 300 127 (1999): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Radiated emission testing of physically large telecommunication systems". [20] ITU-T Recommendation O.41 (1994): "Psophometer for use on telephone-type circuits". [21] ITU-T Recommendation G.996.1 (2001 + Amendment 1: 2003): "Test procedures for digital subscriber line (DSL) transceivers". [22] ETSI TS 101 135 (2000): "Transmission and Multiplexing (TM); High bit-rate Digital Subscriber Line (HDSL) transmission systems on metallic local lines; HDSL core specification and applications for combined ISDN-BA and 2 048 kbit/s transmission". SIST EN 300 386 V1.6.1:2012

ETSI ETSI EN 300 386 V1.6.1 (2012-09) 10 [23] ETSI TS 101 524-1 (2000): "Transmission and Multiplexing (TM); Access transmission system on metallic access cables; Symmetrical single pair high bitrate Digital Subscriber Line (SDSL); Part 1: Functional requirements". [24] ETSI TS 101 270-1 (2005): "Transmission and Multiplexing (TM); Access transmission systems on metallic access cables; Very high speed Digital Subscriber Line (VDSL); Part 1: Functional requirements". [25] ITU-T Recommendation G.992.1 (1999 + Annex H: 2000 + Corrigendum 1: 2001 + Corrigendum 2: 2002 + Amendment 1: 2003 + Corrigendum of Amendment 1: 2003): "Asymmetric digital subscriber line (ADSL) transceivers". [26] ITU-T Recommendation G.992.3 (2009 + Corrigendum 1: 2009 + Amendment 1: 2010 + Amendment 2: 2010 + Amendment 3: 2010 + Corrigendum 2: 2011 + Amendment 4: 2011): "Asymmetric digital subscriber line transceivers 2 (ADSL2)". [27] ITU-T Recommendation G.992.5 (2009 + Corrigendum 1: 2010): "Asymmetric digital subscriber line 2 transceivers (ADSL2) - Extended bandwidth ADSL2 (ADSL2plus)". 2.2 Informative references The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. [i.1] ETSI EN 300 011-1 (2000): "Integrated Services Digital Network (ISDN); Primary rate User Network Interface (UNI); Part 1: Layer 1 specification". [i.2] ETSI EN 300 012-1 (2000): "Integrated Services Digital Network (ISDN); Basic User-Network Interface (UNI); Part 1: Layer 1 specification". [i.3] ETSI EN 300 166 (2001): "Transmission and Multiplexing (TM); Physical and electrical characteristics of hierarchical digital interfaces for equipment using the 2 048 kbit/s - based plesiochronous or synchronous digital hierarchies". [i.4] ETSI ETS 300 232 (1993 + Amendment 1: 1996): "Transmission and Multiplexing (TM); Optical interfaces for equipments and systems relating to the Synchronous Digital Hierarchy (SDH) [ITU-T Recommendation G.957 (1995), modified]". [i.5] ISO/IEC 8802-3 (2000): "Information technology - Telecommunications and information exchange between systems - Local and metropolitan area networks - Specific requirements - Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications". [i.6] ITU-T Recommendation G.661 (2007): "Definition and test methods for the relevant generic parameters of optical amplifier devices and subsystems". [i.7] ITU-T Recommendation G.662 (2005): "Generic characteristics of optical amplifier devices and subsystems". [i.8] ITU-T Recommendation G.712 (2001): "Transmission performance characteristics of pulse code modulation channels". [i.9] ITU-T Recommendation G.812 (2004): "Timing requirements of slave clocks suitable for use as node clocks in synchronization networks". [i.10] ITU-T Recommendation G.813 (2003): "Timing characteristics of SDH equipment slave clocks (SEC)". [i.11] Void. [i.12] ITU-T Recommendation G.961 (1993 + Erratum 1: 2000): "Digital transmission system on metallic local lines for ISDN basic rate access". SIST EN 300 386 V1.6.1:2012

ETSI ETSI EN 300 386 V1.6.1 (2012-09) 11 [i.13] ITU-T Recommendation O.150 (1996 + Corrigendum 1: 2002): "General requirements for instrumentation for performance measurements on digital transmission equipment". [i.14] ITU-T Recommendation Q.552 (2001): "Transmission characteristics at 2-wire analogue interfaces of digital exchanges". [i.15] ITU-T Recommendation V.10 (1993): "Electrical characteristics for unbalanced double-current interchange circuits operating at data signalling rates nominally up to 100 kbit/s". [i.16] ITU-T Recommendation V.11 (1996): "Electrical characteristics for balanced double-current interchange circuits operating at data signalling rates up to 10 Mbit/s". [i.17] ITU-T Recommendation V.24 (2000): "List of definitions for interchange circuits between Data Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE)". [i.18] ITU-T Recommendation V.28 (1993): "Electrical characteristics for unbalanced double-current interchange circuits". [i.19] ITU-T Recommendation V.36 (1988): "Modems for synchronous data transmission using 60-108 kHz group band circuits". [i.20] ITU-T Recommendation X.24 (1988): "List of definitions for interchange circuits between Data Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE) on public data networks". [i.21] ITU-T Recommendation X.25 (1996 + Corrigendum 1: 1998): "Interface between Data Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE) for terminals operating in the packet mode and connected to public data networks by dedicated circuit". [i.22] ETSI TR 101 651 (1999): "Electromagnetic compatibility and radio spectrum matters (ERM); Classification of the electromagnetic environment conditions for equipment in telecommunication networks". [i.23] Directive 98/34/EC of the European Parliament and of the Council of 22 June 1998 laying down a procedure for the provision of information in the field of technical standards and regulations (EMC Directive). [i.24] Council Directive 2004/108/EC of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC (EMC Directive). [i.25] ITU-T Recommendation G.783 (2006 + Erratum 1: 2006 + Amendment 1: 2008 + Amendment 2: 2010): "Characteristics of synchronous digital hierarchy (SDH) equipment functional blocks". [i.26] ITU-T Recommendation G.798 (2010 + Corrigendum 1: 2011 + Amendment 1: 2011): "Characteristics of optical transport network hierarchy equipment functional blocks". [i.27] Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (R&TTE Directive). [i.28] IEEE 1284 (2000): "IEEE Standard Signalling Method for a Bidirectional Parallel Peripheral Interface for Personal Computers". [i.29] IEEE 1394 (2008): "IEEE Standard for High Performance Serial Bus Bridges". [i.30] Directive 98/48/EC of the European Parliament and of the Council of 20 July 1998 amending Directive 98/34/EC laying down a procedure for the provision of information in the field of technical standards and regulations. SIST EN 300 386 V1.6.1:2012

ETSI ETSI EN 300 386 V1.6.1 (2012-09) 12 3 Definitions and abbreviations 3.1 Definitions For the purposes of the present document, the terms and definitions given in IEC 60050-161 [17] and the following apply: NOTE: The definitions taken from IEC 60050-161 [17] have reference in parentheses. AC secondary interface: output port of an AC power supply AC secondary voltage: output of the AC power supply at the AC secondary interface NOTE: The AC secondary voltage may be either: - a stabilized AC supply derived from a DC primary supply (e.g. where the power supply is an inverter); or - derived from the AC primary supply (e.g. a stabilized power supply used where the quality of the primary supply is not sufficient to feed telecommunication equipment). burst (161-02-07): sequence of a limited number of distinct pulses or an oscillation of limited duration connection: temporary association of transmission channels or telecommunication circuits, switching or other functional units set up to provide for the transfer of information between two or more points in a telecommunication network (IEC 60050-714 [18]) continuous disturbance (161-02-11): electromagnetic disturbance the effects of which on a particular device or equipment cannot be resolved into a succession of distinct effects DC secondary interface: output port of a DC power supply DC secondary voltage: output of the DC power supply at the DC secondary interface NOTE: The DC secondary voltage may be derived from the AC primary supply with or without a buffer battery. duration (of a voltage change) (161-08-03): interval of time for the voltage to increase or decrease from the initial value to the final value duration (of a pulse): interval of time between the instants at which the instantaneous value of a pulse reaches 50 % of the pulse magnitude for the first and last time enclosure port: physical boundary of the Equipment Under Test (EUT) through which electromagnetic fields may emanate or on which they may impinge environment, environmental conditions: electromagnetic conditions external to the equipment, to which it is subjected at a certain time NOTE: The environmental conditions comprise a combination of single environmental parameters and their severity. environmental parameters: present one or more properties of the electromagnetic environment immunity (to a disturbance) (161-01-20): ability of a device, equipment or system to perform without degradation in the presence of an electromagnetic disturbance impulsive disturbance (161-02-09): electromagnetic disturbance which, when incident on a particular device or equipment, manifests itself as a succession of distinct pulses or transients interface "A": terminals at which a power supply is connected to the telecommunications equipment multimedia network equipment: multimedia network equipment containing broadcast and telecommunication functions SIST EN 300 386 V1.6.1:2012

ETSI ETSI EN 300 386 V1.6.1 (2012-09) 13 nominal voltage: nominal value of voltage that designates the type of supply normal service: service mode where telecommunications equipment operates within its specification performance criterion: limits of acceptable behaviour of the equipment during and after the application of the electromagnetic phenomenon NOTE: Performance criteria A apply for continuous phenomena; performance criteria B and C apply for transient phenomena; and performance criteria R apply for resistibility phenomena. port: particular interface of the EUT with the external electromagnetic environment power supply: power source (within the scope of the present document) to which telecommunications equipment is intended to be connected primary supply: public mains or a locally generated AC or DC supply public telecommunications network: telecommunication network operated by an entity required to publish its interface specifications under art. 4 of Directive 1999/5/EC [i.27] pulse (161-02-02): abrupt v
...