SIST EN 300 386:2002
(Main)Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements
- Abstract
- to extend the scope to CATV and multimedia equipment with reference to EN50083-2 for the appropriate port requirements - to include Power Line Telecommunication equipment with reference to EN55022 for radio frequency limits and associated measurement methods - to include the applicability statement given in the EN55024 - to include the specific requirements for EMC testing of xDSL Access Systems - to remove the resistibility requirements - to include the radiated immunity test up to 2GHz - to align the emission requirements to EN55022
- Status
- Published
- Publication Date
- 31-Oct-2002
- Technical Committee
- MOC - Mobile Communications
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Nov-2002
- Due Date
- 01-Nov-2002
- Completion Date
- 01-Nov-2002
- Mandate
- T-353
SIST EN 300 386:2002 is the Slovenian adoption of ETSI EN 300 386 V1.3.1 for electromagnetic compatibility (EMC) and radio spectrum matters in telecommunication network equipment. It specifies emission and immunity requirements, test methods and acceptance criteria for equipment used in telecommunication networks, including switching, transmission, power supply, supervisory and DSL access systems.
What does SIST EN 300 386:2002 specify?
SIST EN 300 386:2002 specifies EMC requirements for equipment intended for use within a telecommunication network. It organizes those requirements by general installation environment and by equipment type, so the same document can be used for design verification, type testing and test reporting.
The scope covers switching equipment, non-radio transmission and ancillary equipment, power supply equipment, and supervisory equipment. It also supports multimedia network equipment through Annex C, where RF ports in the sense of the EN 50083 series are treated alongside telecommunication ports.
A few equipment families are outside the scope, including equipment for cabled distribution systems intended only for television and sound signals and optical amplifiers.
| Annex | What it covers |
|---|---|
| Annex A | Normative surge test method for ports of signal lines remaining within the building |
| Annex B | Informative guidance for evaluating test results and preparing the test report |
| Annex C | Informative EMC guidance for RF ports of multimedia network equipment |
What are the key requirements of SIST EN 300 386:2002?
SIST EN 300 386:2002 requires the equipment to be tested in the installation environment it is intended for, with telecommunication centres and other locations treated differently in the limit tables. If the product documentation does not restrict the installation environment, the more severe applicable test level is used. In practice, that means the test plan must match the real site, not just the preferred lab setup.
Clause 5 sets the immunity test approach. Conducted immunity is applied one port at a time, only to permanently connected signal ports, and the test report must justify any test that is not applied. ESD is limited to user-accessible points, which keeps testing focused on real handling conditions.
Clause 5 and Annex A define surge testing for different port types. Outdoor signal lines use the surge method in EN 61000-4-5, while indoor signal lines can use the special Annex A method for unshielded four-wire balanced interfaces with phantom DC power feeding at bit rates up to 2 Mbit/s when the normal coupling network is unsuitable. This matters for ISDN and similar building-internal interfaces, where the line structure changes the test setup.
Clauses 6 and 7 align emissions with EN 55022 and related EMC standards. AC and DC power ports, telecommunication ports and radiated emissions all have specified methods and limits, while AC ports also use EN 61000-3-2 for harmonic current and EN 61000-3-3 for voltage fluctuations. For buyers and test labs, this means the same equipment may need multiple emission measurements depending on the port.
Clause 10 defines the performance criteria used to judge pass or fail. Criterion A allows normal operation during exposure, criterion B allows temporary degradation during the test but no lasting change after it, and criterion C allows temporary loss if the function self-recovers or can be restored. These criteria are the basis for reporting EMC results consistently.
Clauses 11 to 15 add equipment-specific requirements for switching equipment, transmission equipment, DSL access systems, power supply equipment and supervisory equipment. They set port selection rules, operating conditions, selected test frequencies, and functional checks such as connection control, bit error monitoring, noise checks on analogue ports, and false-alarm behavior.
What terms does SIST EN 300 386:2002 define?
- Equipment Under Test (EUT) - the equipment being subjected to EMC measurements and immunity tests.
- Enclosure port - the physical boundary of the EUT through which electromagnetic fields may leave or enter.
- Performance criterion - the accepted level of behavior during and after electromagnetic exposure.
- Primary supply - the public mains or a locally generated AC or DC supply feeding the equipment.
- Secondary supply - supply to racks or system blocks derived from the primary supply.
- Telecommunication network - a licensed network that provides telecommunications between network termination points.
- Radio Frequencies (RF) - the frequency range above 150 kHz.
Who uses SIST EN 300 386:2002?
SIST EN 300 386:2002 is used by telecommunication equipment manufacturers, EMC test laboratories, network operators, system integrators and quality or compliance teams. It helps them choose the correct test setup, define operating conditions, verify immunity and emissions, and document results in a test report that can support product acceptance or conformity assessment.
Which standards are used with SIST EN 300 386:2002?
- EN 55022 - emission methods and limits for conducted and radiated disturbance.
- EN 61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-11 - immunity test methods for ESD, radiated fields, burst, surge, conducted RF disturbances, and dips/interruptions.
- EN 61000-3-2 and EN 61000-3-3 - limits and methods for harmonics and flicker on AC ports.
- EN 50083-2 - EMC requirements for cable network equipment and RF ports used in multimedia network equipment.
- TR 101 651 - classification of electromagnetic environments used to define installation conditions.
- ETS 300 132-1 and ETS 300 132-2 - power supply interface conditions for AC and DC secondary interfaces.
What does the SIST EN 300 386:2002 document contain?
The document contains general scope and references, definitions and abbreviations, installation-environment guidance, test methods for immunity and emissions, and tables of levels and limits by port and environment. It also includes test configurations for switching equipment, transmission equipment, DSL access systems, power supply equipment and supervisory equipment.
Several clauses are built around practical test setups rather than abstract theory. Figures 2 to 7 show representative configurations, and Annex A adds a detailed surge test arrangement with coupling and decoupling networks. Annex B explains how to record conditions, deviations, uncertainty and results, while Annex C links multimedia network equipment RF ports to EN 50083-2 requirements.
Relations
- Official Journal Project Relation
SIST EN 300 386-2:2000 - Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements; Part 2: Product family standard - Effective Date
- 09-Sep-2009
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 300 386:2002 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements". This standard covers: - to extend the scope to CATV and multimedia equipment with reference to EN50083-2 for the appropriate port requirements - to include Power Line Telecommunication equipment with reference to EN55022 for radio frequency limits and associated measurement methods - to include the applicability statement given in the EN55024 - to include the specific requirements for EMC testing of xDSL Access Systems - to remove the resistibility requirements - to include the radiated immunity test up to 2GHz - to align the emission requirements to EN55022
- to extend the scope to CATV and multimedia equipment with reference to EN50083-2 for the appropriate port requirements - to include Power Line Telecommunication equipment with reference to EN55022 for radio frequency limits and associated measurement methods - to include the applicability statement given in the EN55024 - to include the specific requirements for EMC testing of xDSL Access Systems - to remove the resistibility requirements - to include the radiated immunity test up to 2GHz - to align the emission requirements to EN55022
SIST EN 300 386:2002 is classified under the following ICS (International Classification for Standards) categories: 33.050.01 - Telecommunication terminal equipment in general; 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 386:2002 has the following relationships with other standards: It is inter standard links to SIST EN 300 386-2:2000. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 300 386:2002 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EU, 2010-01-3290; Standardization Mandates: T-353. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 300 386:2002 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Elektromagnetna združljivost (EMC) in zadeve v zvezi z radijskim spektrom (ERM) - Oprema za telekomunikacijsko omrežje - Zahteve za elektromagnetno združljivost (EMC)Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements33.100.01Elektromagnetna združljivost na splošnoElectromagnetic compatibility in general33.050.01Telekomunikacijska terminalska oprema na splošnoTelecommunication terminal equipment in generalICS:Ta slovenski standard je istoveten z:EN 300 386 Version 1.3.1SIST EN 300 386:2002en01-november-2002SIST EN 300 386:2002SLOVENSKI
STANDARD
ETSI ETSI EN 300 386 V1.3.1 (2001-09)2
Reference REN/ERM-EMC-223 Keywords EMC, network, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C Association à but non lucratif enregistrée à la Sous-Préfecture de Grasse (06) N° 7803/88
Important notice Individual copies of the present document can be downloaded from: http://www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http://portal.etsi.org/tb/status/status.asp If you find errors in the present document, send your comment to: editor@etsi.fr Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2001. All rights reserved.
ETSI ETSI EN 300 386 V1.3.1 (2001-09)3 Contents Intellectual Property Rights.6 Foreword.6 1 Scope.7 2 References.8 3 Definitions and abbreviations.11 3.1 Definitions.11 3.2 Abbreviations.12 4 Installation environment.13 5 Immunity: test methods.13 5.1 Electrostatic discharge.13 5.2 Electrical fast transients/burst.13 5.3 Surges.13 5.3.1 Outdoor signal line ports.13 5.3.2 Indoor signal line ports.14 5.3.3 AC power ports.14 5.4 Immunity to continuous conducted signals.14 5.4.1 Low frequency ( 150 kHz).14 5.4.2 Radio frequency (> 150 kHz).14 5.4.2.1 AC power port.14 5.4.2.2 DC power port.14 5.4.2.3 Signal line port.14 5.5 Immunity to radiated electromagnetic fields.14 5.6 Immunity to power supply disturbances: AC and DC power ports.15 5.6.1 Test of immunity to low frequency disturbances: AC power ports.15 6 Emission: test methods.15 6.1 AC power port.15 6.2 DC power port.15 6.3 Telecommunication Port.16 6.4 Radiated emission.16 7 Test levels and limits.16 7.1 Emission.16 7.1.1 Enclosure port, Radiated electromagnetic field emissions.16 7.1.2 AC ports.17 7.1.2.1 Conducted emissions.17 7.1.2.2 Current harmonics.17 7.1.2.3 Voltage fluctuations.17 7.1.3 DC ports; Conducted emissions.17 7.1.4 Telecommunication ports; Conducted emissions.17 7.2 Immunity.18 7.2.1 Equipment operating in telecommunication centres.18 7.2.1.1 Telecommunication centres, enclosure port.18 7.2.1.2 Telecommunication centres, ports for outdoor signal lines.19 7.2.1.3 Telecommunication centres, ports for indoor signal lines.20 7.2.1.4 Telecommunication centres, AC power ports.20 7.2.1.5 Telecommunication centres, DC power ports.21 7.2.2 Equipment operating in locations other than telecommunication centres.21 7.2.2.1 Other than telecommunication centres, enclosure port.21 7.2.2.2 Other than telecommunication centres, ports for outdoor signal lines.22 7.2.2.3 Other than telecommunication centres, ports for indoor signal lines.22 7.2.2.4 Other than telecommunication centres, AC power ports.23 7.2.2.5 Other than telecommunication centres, DC power ports.23 SIST EN 300 386:2002
ETSI ETSI EN 300 386 V1.3.1 (2001-09)4 8 General test configuration.24 9 General operational conditions during testing.24 9.1 Equipment configuration.24 9.2 Operation of multimedia network equipment.25 10 General immunity conditions.25 10.1 General performance criteria.25 11 Switching equipment specific requirements.26 11.1 Test configuration.26 11.2 Operational conditions.27 11.2.1 Emission.27 11.2.2 Immunity.27 11.3 Specific immunity performance criteria.27 11.3.1 Digital port performance criteria.27 11.3.1.1 Performance criterion A (continuous phenomena).27 11.3.1.2 Performance criterion B (transient phenomena).28 11.3.1.3 Performance criterion C (interruptions).28 11.3.2 Analogue port performance criteria.28 11.3.2.1 Performance criterion A (continuous phenomena).28 11.3.2.2 Performance criterion B (transient phenomena).28 11.3.2.3 Performance criterion C (interruptions).28 12 Transmission equipment specific requirements.28 12.1 Test configuration.28 12.2 Operational conditions.29 12.2.1 Emission.29 12.2.2 Immunity.29 12.3 Specific immunity performance criteria.29 12.3.1 Digital signal ports.29 12.3.1.1 Performance criterion A (continuous phenomena).30 12.3.1.2 Performance criterion B (transient phenomena).30 12.3.1.3 Performance criterion C (interruptions).30 12.3.2 Analogue voice frequency signal ports.30 12.3.2.1 Performance criterion A (continuous phenomena).30 12.3.2.2 Performance criterion B (transient phenomena).30 12.3.3 SDH and PDH interfaces.30 12.3.3.1 Tributary and aggregate interfaces.30 12.3.4 ISDN interfaces.31 12.3.4.1 Primary rate access ISDN interfaces.31 12.3.4.2 Network termination NT1 for ISDN "U" interfaces.31 12.3.4.3 Basic access ISDN interfaces.31 12.3.5 Analogue interfaces.31 12.3.5.1 Trunk interfaces and leased line interfaces.31 12.3.5.2 Subscriber interfaces.31 12.3.6 V.10, V.11, V.24, V.28, V.36, X.24 and similar V.- and X.- series interfaces.31 12.3.7 Ethernet and packet-data interfaces.31 12.3.7.1 Performance criterion A (continuous phenomena).31 12.3.7.2 Performance criterion B (transient phenomena).31 12.3.8 Service and maintenance interfaces.31 12.3.9 Synchronization interfaces.32 12.3.9.1 Performance criterion A (continuous phenomena).32 12.3.9.2 Performance criterion B (transient phenomena).32 12.3.10 Remote alarm interfaces.32 12.3.10.1 Performance criterion A (continuous phenomena).32 12.3.10.2 Performance criterion B (transient phenomena).32 13 Digital Subscriber Line (DSL) Access Systems.32 13.1 Test configuration.32 13.2 Operational conditions.33 13.2.1 Immunity.33 13.3 Specific Immunity performance criteria.33 SIST EN 300 386:2002
...