Abstract

The present document covers the EMC requirements for equipment intended to be used within a telecommunications network (as defined in clause 3). Examples of such equipment are:
• Switching equipment. Such equipment includes:
- local telephone exchanges;
- remote switching concentrators;
- international switches;
- telex switches;
- network packet switches.
• General purpose equipment, which is used as a part of a switching system, may be covered by the scope of other standards. For such equipment, if those other standards fully cover all the requirements of the present document, no further requirements are necessary. Switching equipment can also contain transmission functions, and this has to be recognized during testing.
• Non-radio transmission equipment and ancillary equipment. Such equipment includes:
- multiplexers;
- line equipment and repeaters, e.g. equipment for:
- Synchronous Digital Hierarchy (SDH);
- Plesiochronous Digital Hierarchy (PDH);
- Asynchronous Transfer Mode (ATM);
such as:
- Digital Cross Connect systems;
- network terminations;
- transmission equipment used in the access network like XDSL.
• Power supply equipment. Such equipment includes:
- central power plant;
- end of suite power supplies;
- uninterruptible power supplies;
- stabilized AC power supplies;
- and other dedicated telecommunication network power supplies;
but excludes equipment which is uniquely associated with or integrated in other equipment.
• Supervisory equipment. Such equipment includes:
- network management equipment;
- operator access maintenance equipment;
- traffic measurement systems;
- line test units;
- functional test units.
The function of supervision may either be performed by independent equipment or form part of other telecommunication equipment. If the function of supervision forms part of a telecommunication equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission) during EMC testing. The environmental classification used in the present document refers to TR 101 651 [42]. The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures may have to be employed. Equipment for cabled distribution systems intended only for television and sound signals as defined in EN 50083-2 [3] and optical amplifiers as defined in ITU-T Recommendations G.661 [23] and G.662 [24] are outside the scope of the present document.

Status
Published
Publication Date
28-Feb-2006
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Mar-2006
Due Date
01-Mar-2006
Completion Date
01-Mar-2006
Mandate
T-353

Buy Documents

Standard

SIST EN 300 386 V1.3.3:2006

English language (48 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 300 386 V1.3.3:2006 is the Slovenian adoption of ETSI EN 300 386 V1.3.3 for electromagnetic compatibility (EMC) requirements on telecommunication network equipment. It specifies how network equipment is tested for emissions and immunity, and it is intended for manufacturers, EMC test laboratories, quality teams, and buyers who need to judge whether switching, transmission, power supply, or supervisory equipment fits a telecommunications network environment.

What does SIST EN 300 386 V1.3.3:2006 specify?

SIST EN 300 386 V1.3.3:2006 covers EMC requirements for equipment intended to be used within a telecommunications network. The scope includes switching equipment, non-radio transmission equipment and ancillary equipment, power supply equipment, and supervisory equipment.

The standard also sets the installation environment and test context. It uses the environmental classification from TR 101 651, and if no installation restrictions are stated in the product documentation, the equipment is expected to comply with the requirements for all environments, using the more severe test level where needed.

Some equipment is outside the scope, including equipment for cabled distribution systems intended only for television and sound signals, and optical amplifiers. General-purpose equipment used as part of a switching system may be covered by other standards if those standards fully cover the same requirements.

The document is organized into clauses 1 to 15, followed by five annexes.

AnnexWhat it covers
Annex ANormative surge test method for signal line ports remaining within the building, including ISDN set-ups
Annex BInformative guidance for evaluating test results and writing the test report
Annex CInformative guidance for EMC performance requirements and measurement methods for RF ports of multimedia network equipment
Annex DInformative EN title in the official languages
Annex EInformative bibliography

What are the key requirements of SIST EN 300 386 V1.3.3:2006?

SIST EN 300 386 V1.3.3:2006 focuses on how to test ports, what test levels to use, and how equipment must behave during and after EMC exposure. In practice, the standard is built around representative installation conditions, one-port-at-a-time testing for conducted immunity, and performance criteria that match the function of the equipment.

General test setup and port selection

Clause 8 requires the Equipment Under Test (EUT) to be configured as close as possible to normal installed use, with the correct terminations, grounding, cabling, and housing in place. Only permanently connected cables are included, and the selected configuration must be recorded in the test report.

Clause 5 says conducted immunity is applied to one port at a time, and only one port of each type needs to be tested. If a test is not appropriate for a specific port, the decision and the justification must be written into the report. That matters because the standard expects traceable engineering decisions, not informal exclusions.

Immunity methods and when they apply

Clause 5 assigns the main immunity methods:

  • electrostatic discharge (ESD) per EN 61000-4-2 on accessible user-touch points
  • electrical fast transients/burst per EN 61000-4-4
  • surges per EN 61000-4-5
  • conducted RF immunity per EN 61000-4-6
  • radiated RF immunity per EN 61000-4-3
  • voltage dips, short interruptions, and voltage variations on AC power ports in locations other than telecommunication centres per EN 61000-4-11

The standard also distinguishes between telecommunication centres and other locations. The immunity levels are higher for equipment used outside telecommunication centres, which matters when you are deciding whether the product is meant for a controlled network room or for a harsher site such as an office or customer premises.

Emission methods and limits

Clause 6 sets the emission methods. AC power port conducted emissions are measured with EN 55022, current harmonics follow EN 61000-3-2, and voltage fluctuations or flicker follow EN 61000-3-3. DC power port conducted emissions also use the EN 55022 mains-interface approach with an artificial network.

Radiated emissions use EN 55022 in the 30 MHz to 1 000 MHz range, and physically large equipment can use EN 300 127. Clause 7 then points back to the relevant limits, including EN 55022 limits for enclosure and telecommunication ports and the class A limit for DC port conducted emissions.

Equipment-specific criteria

Switching equipment has to be tested while connection setup, connection clearing, and signal quality are monitored together. Clause 11 requires performance on digital ports and analogue ports to be judged against specific criteria for continuous phenomena, transient phenomena, and interruptions. For example, a connection must stay established during continuous exposure, and after transient exposure the equipment must still be able to set up and clear connections in a controlled way.

Transmission equipment in clause 12 is tested with representative tributary and aggregate signals. The preferred test signal is a Pseudo Random Bit Sequence (PRBS), and the equipment must be assessed for bit errors, function after exposure, and any corruption of stored software or data. Clause 12 also applies the relevant criteria to interface families such as SDH, PDH, ISDN, V.-series, Ethernet, packet-data, synchronization, and remote alarm interfaces.

Digital Subscriber Line (DSL) access systems in clause 13 are tested while trained up at nominal rate and with line attenuation chosen to reach minimum acceptable noise margin. The equipment must maintain connection, avoid reproducible bit errors or loss of synchronization, and recover after exposure. The clause also requires attention to POTS/ISDN noise breakthrough where applicable.

Power supply equipment in clause 14 is treated as equipment intended for power distribution within telecommunication centres. It must be assessed at AC secondary and DC secondary interfaces, plus control and signal interfaces. Supervisory equipment in clause 15 must keep the supervising and supervised functions connected, avoid false alarms, and recover normal operation after transients.

What terms does SIST EN 300 386 V1.3.3:2006 define?

  • Equipment Under Test (EUT) - the device or system being checked for EMC performance.
  • enclosure port - the physical boundary of the EUT where electromagnetic fields can leave or enter.
  • performance criterion - the acceptable behaviour of the equipment during or after EMC exposure.
  • telecommunication network - a licensed network providing telecommunications between Network Termination Points (NTPs), excluding terminal equipment beyond the NTPs.
  • main signal port - a port that provides the telecommunications service traffic.
  • auxiliary signal port - a port used for alarms, maintenance, or other operator functions.
  • Digital Subscriber Line (DSL) - the access-system family covered in clause 13.
  • Radio Frequencies (RF) - the frequency range above 150 kHz.

Who uses SIST EN 300 386 V1.3.3:2006?

SIST EN 300 386 V1.3.3:2006 is used by manufacturers of telecommunication network equipment, EMC test laboratories, compliance engineers, quality managers, and procurement teams. It is especially relevant for switching systems, transmission systems, DSL access systems, network power supplies, and supervisory equipment.

In practice, users apply it to choose the right test configuration, decide which ports need testing, select the correct immunity and emission standards, and document pass/fail results in a way that can be audited.

What changed in SIST EN 300 386 V1.3.3:2006 from the previous edition?

SIST EN 300 386 V1.3.3:2006 corresponds to EN 300 386 Version 1.3.3. The document history shows the version progression up to V1.3.3, published in April 2005.

Which standards are used with SIST EN 300 386 V1.3.3:2006?

The document relies on a set of test and interface standards to define methods and acceptance criteria:

  • EN 61000-4-2 - ESD immunity test method
  • EN 61000-4-3 - radiated RF immunity test method
  • EN 61000-4-4 - electrical fast transient/burst test method
  • EN 61000-4-5 - surge immunity test method
  • EN 61000-4-6 - conducted RF immunity test method
  • EN 61000-4-11 - voltage dips, short interruptions, and voltage variations
  • EN 55022 - conducted and radiated emission methods and limits
  • EN 61000-3-2 and EN 61000-3-3 - harmonics and flicker limits
  • TR 101 651 - classification of electromagnetic installation environments
  • EN 50082-1 - general immunity performance criterion C
  • EN 50083-2 - RF port EMC requirements for cable distribution and multimedia network equipment
  • ETS 300 011, ETS 300 012, ETS 300 132-1, ETS 300 132-2, ETS 300 166, ETS 300 232, ITU-T G.958, G.961, G.712, Q.552, V.10, V.11, V.24, V.28, V.36, X.24, X.25, G.812, G.813 - specific interface definitions and performance references used for ISDN, power supply, transmission, analogue, serial, packet-data, and synchronization interfaces

What does the SIST EN 300 386 V1.3.3:2006 document contain?

The document contains the full EMC test framework for telecommunication network equipment: scope, references, definitions, installation environments, immunity methods, emission methods, test levels, and equipment-specific criteria. It uses tables for emission and immunity limits, including separate levels for telecommunication centres and other locations.

It also contains the practical parts a test engineer needs: general test configuration rules, operational conditions during testing, and performance criteria for switching equipment, transmission equipment, DSL access systems, power supply equipment, and supervisory equipment.

Figures support the procedures, including the conducted emission set-up for DC power interfaces, the switching-equipment test arrangement, the transmission-equipment loop-through arrangement, the DSL access system configuration, and the power-supply port identification diagrams. Annex A adds surge test set-ups for ISDN-type signal line ports, while Annex B gives the content expected in test reports.

Relations

Effective Date
09-Sep-2009
Effective Date
05-Jun-2009

Buy Documents

Standard

SIST EN 300 386 V1.3.3:2006

English language (48 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN 300 386 V1.3.3:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements". This standard covers: The present document covers the EMC requirements for equipment intended to be used within a telecommunications network (as defined in clause 3). Examples of such equipment are: • Switching equipment. Such equipment includes: - local telephone exchanges; - remote switching concentrators; - international switches; - telex switches; - network packet switches. • General purpose equipment, which is used as a part of a switching system, may be covered by the scope of other standards. For such equipment, if those other standards fully cover all the requirements of the present document, no further requirements are necessary. Switching equipment can also contain transmission functions, and this has to be recognized during testing. • Non-radio transmission equipment and ancillary equipment. Such equipment includes: - multiplexers; - line equipment and repeaters, e.g. equipment for: - Synchronous Digital Hierarchy (SDH); - Plesiochronous Digital Hierarchy (PDH); - Asynchronous Transfer Mode (ATM); such as: - Digital Cross Connect systems; - network terminations; - transmission equipment used in the access network like XDSL. • Power supply equipment. Such equipment includes: - central power plant; - end of suite power supplies; - uninterruptible power supplies; - stabilized AC power supplies; - and other dedicated telecommunication network power supplies; but excludes equipment which is uniquely associated with or integrated in other equipment. • Supervisory equipment. Such equipment includes: - network management equipment; - operator access maintenance equipment; - traffic measurement systems; - line test units; - functional test units. The function of supervision may either be performed by independent equipment or form part of other telecommunication equipment. If the function of supervision forms part of a telecommunication equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission) during EMC testing. The environmental classification used in the present document refers to TR 101 651 [42]. The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures may have to be employed. Equipment for cabled distribution systems intended only for television and sound signals as defined in EN 50083-2 [3] and optical amplifiers as defined in ITU-T Recommendations G.661 [23] and G.662 [24] are outside the scope of the present document.

The present document covers the EMC requirements for equipment intended to be used within a telecommunications network (as defined in clause 3). Examples of such equipment are: • Switching equipment. Such equipment includes: - local telephone exchanges; - remote switching concentrators; - international switches; - telex switches; - network packet switches. • General purpose equipment, which is used as a part of a switching system, may be covered by the scope of other standards. For such equipment, if those other standards fully cover all the requirements of the present document, no further requirements are necessary. Switching equipment can also contain transmission functions, and this has to be recognized during testing. • Non-radio transmission equipment and ancillary equipment. Such equipment includes: - multiplexers; - line equipment and repeaters, e.g. equipment for: - Synchronous Digital Hierarchy (SDH); - Plesiochronous Digital Hierarchy (PDH); - Asynchronous Transfer Mode (ATM); such as: - Digital Cross Connect systems; - network terminations; - transmission equipment used in the access network like XDSL. • Power supply equipment. Such equipment includes: - central power plant; - end of suite power supplies; - uninterruptible power supplies; - stabilized AC power supplies; - and other dedicated telecommunication network power supplies; but excludes equipment which is uniquely associated with or integrated in other equipment. • Supervisory equipment. Such equipment includes: - network management equipment; - operator access maintenance equipment; - traffic measurement systems; - line test units; - functional test units. The function of supervision may either be performed by independent equipment or form part of other telecommunication equipment. If the function of supervision forms part of a telecommunication equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission) during EMC testing. The environmental classification used in the present document refers to TR 101 651 [42]. The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures may have to be employed. Equipment for cabled distribution systems intended only for television and sound signals as defined in EN 50083-2 [3] and optical amplifiers as defined in ITU-T Recommendations G.661 [23] and G.662 [24] are outside the scope of the present document.

SIST EN 300 386 V1.3.3:2006 is classified under the following ICS (International Classification for Standards) categories: 33.050.01 - Telecommunication terminal equipment in general; 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 300 386 V1.3.3:2006 has the following relationships with other standards: It is inter standard links to SIST EN 300 386-2:2000, SIST EN 300 386 V1.4.1:2008. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 300 386 V1.3.3:2006 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EU, 2010-01-3290; Standardization Mandates: T-353. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 300 386 V1.3.3:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 8 ETSI EN 300 386 V1.3.3 (2005-04)
  • 2 References
  • 9 ETSI EN 300 386 V1.3.3 (2005-04)
  • 10 ETSI EN 300 386 V1.3.3 (2005-04)
  • 11 ETSI EN 300 386 V1.3.3 (2005-04)
  • 3 Definitions and abbreviations
  • 3.1 Definitions
  • 12 ETSI EN 300 386 V1.3.3 (2005-04)
  • 3.2 Abbreviations
  • 13 ETSI EN 300 386 V1.3.3 (2005-04)
  • 4 Installation environment
  • 5 Immunity: test methods
  • 5.1 Electrostatic discharge
  • 5.2 Electrical fast transients/burst
  • 14 ETSI EN 300 386 V1.3.3 (2005-04)
  • 5.3 Surges
  • 5.4 Immunity to continuous conducted signals
  • 15 ETSI EN 300 386 V1.3.3 (2005-04)
  • 5.5 Immunity to radiated electromagnetic fields
  • 5.6 Immunity to power supply disturbances: AC and DC power
  • 6 Emission: test methods
  • 6.1 AC power port
  • 6.2 DC power port
  • 16 ETSI EN 300 386 V1.3.3 (2005-04)
  • 6.3 Telecommunication Port
  • 6.4 Radiated emission
  • 17 ETSI EN 300 386 V1.3.3 (2005-04)
  • 7 Test levels and limits
  • 7.1 Emission
  • 18 ETSI EN 300 386 V1.3.3 (2005-04)
  • 7.2 Immunity
  • 19 ETSI EN 300 386 V1.3.3 (2005-04)
  • 20 ETSI EN 300 386 V1.3.3 (2005-04)
  • 21 ETSI EN 300 386 V1.3.3 (2005-04)
  • 22 ETSI EN 300 386 V1.3.3 (2005-04)
  • 23 ETSI EN 300 386 V1.3.3 (2005-04)
  • 24 ETSI EN 300 386 V1.3.3 (2005-04)
  • 8 General test configuration
  • 9 General operational conditions during testing
  • 9.1 Equipment configuration
  • 25 ETSI EN 300 386 V1.3.3 (2005-04)
  • 9.2 Operation of multimedia network equipment
  • 10 General immunity conditions
  • 10.1 General performance criteria
  • 26 ETSI EN 300 386 V1.3.3 (2005-04)
  • 11 Switching equipment specific requirements
  • 11.1 Test configuration
  • 27 ETSI EN 300 386 V1.3.3 (2005-04)
  • 11.2 Operational conditions
  • 11.3 Specific immunity performance criteria
  • 28 ETSI EN 300 386 V1.3.3 (2005-04)
  • 12 Transmission equipment specific requirements
  • 12.1 Test configuration
  • 29 ETSI EN 300 386 V1.3.3 (2005-04)
  • 12.2 Operational conditions
  • 12.3 Specific immunity performance criteria
  • 30 ETSI EN 300 386 V1.3.3 (2005-04)
  • 31 ETSI EN 300 386 V1.3.3 (2005-04)
  • 32 ETSI EN 300 386 V1.3.3 (2005-04)
  • 13 Digital Subscriber Line (DSL) Access Systems
  • 13.1 Test configuration
  • 33 ETSI EN 300 386 V1.3.3 (2005-04)
  • 13.2 Operational conditions
  • 13.3 Specific Immunity performance criteria
  • 34 ETSI EN 300 386 V1.3.3 (2005-04)
  • 14 Power supply equipment specific conditions
  • 14.1 Test configuration
  • 35 ETSI EN 300 386 V1.3.3 (2005-04)
  • 14.2 Operational conditions
  • 14.3 Specific immunity performance criteria
  • 36 ETSI EN 300 386 V1.3.3 (2005-04)
  • 37 ETSI EN 300 386 V1.3.3 (2005-04)
  • 25 Hz to 5 kHz 10 mV Upso
  • 15 Supervisory equipment specific conditions
  • 15.1 Test configuration
  • 38 ETSI EN 300 386 V1.3.3 (2005-04)
  • 15.2 Operational conditions
  • 15.3 Specific immunity and resistibility performance criteria
  • 39 ETSI EN 300 386 V1.3.3 (2005-04)

1 Scope

The present document covers the EMC requirements for equipment intended to be used within a telecommunications network (as defined in clause 3). Examples of such equipment are:

  • Switching equipment. Such equipment includes:
  • local telephone exchanges;
  • remote switching concentrators;
  • international switches;
  • telex switches;
  • network packet switches.
  • General purpose equipment, which is used as a part of a switching system, may be covered by the scope of other standards. For such equipment, if those other standards fully cover all the requirements of the present document, no further requirements are necessary. Switching equipment can also contain transmission functions, and this has to be recognized during testing.
  • Non-radio transmission equipment and ancillary equipment. Such equipment includes:
  • multiplexers;
  • line equipment and repeaters, e.g. equipment for:
  • Synchronous Digital Hierarchy (SDH);
  • Plesiochronous Digital Hierarchy (PDH);
  • Asynchronous Transfer Mode (ATM); such as:
  • Digital Cross Connect systems;
  • network terminations;
  • transmission equipment used in the access network like XDSL.
  • Power supply equipment. Such equipment includes:
  • central power plant;
  • end of suite power supplies;
  • uninterruptible power supplies;
  • stabilized AC power supplies;
  • and other dedicated telecommunication network power supplies; but excludes equipment which is uniquely associated with or integrated in other equipment. ETSI

SIST EN 300 386 V1.3.3:2006

8 ETSI EN 300 386 V1.3.3 (2005-04)

  • Supervisory equipment. Such equipment includes:
  • network management equipment;
  • operator access maintenance equipment;
  • traffic measurement systems;
  • line test units;
  • functional test units.

The function of supervision may either be performed by independent equipment or form part of other telecommunication equipment. If the function of supervision forms part of a telecommunication equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission) during EMC testing.

The environmental classification used in the present document refers to TR 101 651 [42]. The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures may have to be employed.

Equipment for cabled distribution systems intended only for television and sound signals as defined in EN 50083-2 [3] and optical amplifiers as defined in ITU-T Recommendations G.661 [23] and G.662 [24] are outside the scope of the present document.

2 References

The following documents contain provisions which, through reference in this text, constitute provisions of the present document.

  • References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
  • For a specific reference, subsequent revisions do not apply.
  • For a non-specific reference, the latest version applies.

Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.

[1] CISPR 16-1: "Specification for radio disturbance and immunity measuring apparatus and methods; Part 1: Radio disturbance and immunity measuring apparatus".

[2] EN 50082-1 (1997): "Electromagnetic compatibility - Generic immunity standard - Part 1: Residential, commercial and light industry".

[3] EN 50083-2 (1995): "Cable networks for television signals, sound signals and interactive services - Part 2: Electromagnetic compatibility for equipment". [4] EN 55022 (1998): "Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement".

[5] EN 61000-3-2 (2000): "Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)". [6] EN 61000-3-3 (1995): "Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection". ETSI

SIST EN 300 386 V1.3.3:2006

9 ETSI EN 300 386 V1.3.3 (2005-04)

[7] EN 61000-4-2: "Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test".

[8] EN 61000-4-3: "Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test". [9] EN 61000-4-4: "Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test".

[10] EN 61000-4-5: "Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test".

[11] EN 61000-4-6: "Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields". [12] EN 61000-4-11: "Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests". [13] Void [14] ETSI ETS 300 011 (1998): "Integrated Services Digital Network (ISDN); Primary rate user-network interface; Layer 1 specification and test principles". [15] ETSI ETS 300 012 (1992): "Integrated Services Digital Network (ISDN); Basic user-network interface; Layer 1 specification and test principles".

[16] ETSI ETS 300 132-1 (1996): "Equipment Engineering (EE); Power supply interface at the input to telecommunications equipment; Part 1: Operated by alternating current (ac) derived from direct current (dc) sources".

[17] ETSI ETS 300 132-2 (1996): "Equipment Engineering (EE); Power supply interface at the input to telecommunications equipment; Part 2: Operated by direct current (dc)". [18] ETSI ETS 300 166 (1993): "Transmission and Multiplexing (TM); Physical and electrical characteristics of hierarchical digital interfaces for equipment using the 2 048 kbit/s - based plesiochronous or synchronous digital hierarchies".

[19] ETSI ETS 300 232 (1993): "Transmission and Multiplexing (TM); Optical interfaces for equipments and systems relating to the Synchronous Digital Hierarchy [ITU-T Recommendation G.957 (1993), modified]".

[20] IEC 60050-161: "International Electrotechnical Vocabulary. Chapter 161: Electromagnetic compatibility".

[21] IEC 60050-714: "International Electrotechnical Vocabulary - Chapter 714: Switching and signalling in telecommunications".

[22] ISO/IEC 8802-3 (1996): "Information technology - Telecommunications and information exchange between systems - Local and metropolitan area networks - Specific requirements - Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications".

[23] ITU-T Recommendation G.661 (1998): "Definition and test methods for the relevant generic parameters of optical amplifier devices and subsystems".

[24] ITU-T Recommendation G.662 (1998): "Generic characteristics of optical amplifier devices and subsystems".

[25] ITU-T Recommendation G.712 (1996): "Transmission performance characteristics of pulse code modulation channels".

[26] ITU-T Recommendation G.812 (1998): "Timing requirements of slave clocks suitable for use as node clocks in synchronization networks".

[27] ITU-T Recommendation G.813 (1996): "Timing characteristics of SDH equipment slave clocks (SEC)".

ETSI

SIST EN 300 386 V1.3.3:2006

10 ETSI EN 300 386 V1.3.3 (2005-04)

[28] ITU-T Recommendation G.958 (1994): "Digital line systems based on the synchronous digital hierarchy for use on optical fibre cables".

[29] ITU-T Recommendation G.961 (1993): "Digital transmission system on metallic local lines for ISDN basic rate access".

[30] ETSI EN 300 127: "Electromagnetic compatibility and Radio spectrum Matters (ERM); Radiated emission testing of physically large telecommunication systems". [31] ITU-T Recommendation O.41 (1994): "Psophometer for use on telephone-type circuits". [32] ITU-T Recommendation O.150 (1996): "General requirements for instrumentation for performance measurements on digital transmission equipment".

[33] ITU-T Recommendation Q.552 (1996): "Transmission characteristics at 2-wire analogue interfaces of digital exchanges".

[34] ITU-T Recommendation V.10 (1993): "Electrical characteristics for unbalanced double-current interchange circuits operating at data signalling rates nominally up to 100 kbit/s". [35] ITU-T Recommendation V.11 (1996): "Electrical characteristics for balanced double-current interchange circuits operating at data signalling rates up to 10 Mbit/s". [36] ITU-T Recommendation V.24 (2000): "List of definitions for interchange circuits between Data Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE)". [37] ITU-T Recommendation V.28 (1993): "Electrical characteristics for unbalanced double-current interchange circuits".

[38] ITU-T Recommendation V.36 (1988): "Modems for synchronous data transmission using 60-108 kHz group band circuits".

[39] ITU-T Recommendation X.24 (1988): "List of definitions for interchange circuits between Data Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE) on public data networks".

[40] ITU-T Recommendation X.25 (1996): "Interface between Data Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE) for terminals operating in the packet mode and connected to public data networks by dedicated circuit".

[41] Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility.

[42] ETSI TR 101 651 (V1.1.1): "Electromagnetic compatibility and radio spectrum matters (ERM); Classification of the electromagnetic environment conditions for equipment in telecommunication networks".

[43] Directive 98/34/EC of the European Parliament and of the Council of 22 June 1998 laying down a procedure for the provision of information in the field of technical standards and regulations. [44] ITU-T Recommendation G.996.1 (1999): "Test procedures for digital subscriber line (DSL) transceivers".

[45] ETSI TS 101 135 (V1.5.3): "Transmission and Multiplexing (TM); High bit-rate Digital Subscriber Line (HDSL) transmission systems on metallic local lines; HDSL core specification and applications for combined ISDN-BA and 2 048 kbit/s transmission". [46] ETSI TS 101 524-1 (V1.1.1): "Transmission and Multiplexing (TM); Access transmission system on metallic access cables; Symmetrical single pair high bit rate Digital Subscriber Line (SDSL); Part 1: Functional requirements".

[47] ETSI TS 101 270-1 (V1.2.1): "Transmission and Multiplexing (TM); Access transmission systems on metallic access cables; Very high speed Digital Subscriber Line (VDSL); Part 1: Functional requirements".

ETSI

SIST EN 300 386 V1.3.3:2006

11 ETSI EN 300 386 V1.3.3 (2005-04)

3 Definitions and abbreviations

3.1 Definitions

For the purposes of the present document, the following terms and definitions apply. The definitions taken from the IEC 60050-161 [20] have reference in parentheses.

AC secondary interface: output port of an AC power supply AC secondary voltage: output of the AC power supply at the AC secondary interface NOTE: The AC secondary voltage may be either:

  • a stabilized AC supply derived from a DC primary supply (e.g. where the power supply is an inverter); or
  • derived from the AC primary supply (e.g. a stabilized power supply used where the quality of the primary supply is not sufficient to feed telecommunication equipment). burst (161-02-07): sequence of a limited number of distinct pulses or an oscillation of limited duration connection: temporary association of transmission channels or telecommunication circuits, switching or other functional units set up to provide for the transfer of information between two or more points in a telecommunication network (IEC 60050-714) continuous disturbance (161-02-11): electromagnetic disturbance the effects of which on a particular device or equipment cannot be resolved into a succession of distinct effects DC secondary interface: output port of a DC power supply DC secondary voltage: output of the DC power supply at the DC secondary interface The DC secondary voltage may be derived from the AC primary supply with or without a buffer battery. duration (of a voltage change) (161-08-03): interval of time for the voltage to increase or decrease from the initial value to the final value duration (of a pulse): interval of time between the instants at which the instantaneous value of a pulse reaches 50 % of the pulse magnitude for the first and last time enclosure port: physical boundary of the Equipment Under Test (EUT) through which electromagnetic fields may emanate or on which they may impinge environment, environmental conditions: electromagnetic conditions external to the equipment, to which it is subjected at a certain time The environmental conditions comprise a combination of single environmental parameters and their severity. environmental parameters: present one or more properties of the electromagnetic environment immunity (to a disturbance) (161-01-20): ability of a device, equipment or system to perform without degradation in the presence of an electromagnetic disturbance impulsive disturbance (161-02-09): electromagnetic disturbance which, when incident on a particular device or equipment, manifests itself as a succession of distinct pulses or transients interface "A": terminals at which a power supply is connected to the telecommunications equipment multimedia network equipment: multimedia network equipment containing broadcast and telecommunication functions nominal voltage: nominal value of voltage that designates the type of supply normal service: service mode where telecommunications equipment operates within its specification ETSI

SIST EN 300 386 V1.3.3:2006

12 ETSI EN 300 386 V1.3.3 (2005-04)

performance criterion: limits of acceptable behaviour of the equipment during and after the application of the electromagnetic phenomenon NOTE: Performance criteria A apply for continuous phenomena; performance criteria B and C apply for transient phenomena; and performance criteria R apply for resistibility phenomena. port: particular interface of the EUT with the external electromagnetic environment power supply: power source (within the scope of EN 300 386) to which telecommunications equipment is intended to be connected primary supply: public mains or a locally generated AC or DC supply pulse (161-02-02): abrupt variation of short duration of a physical quantity followed by a rapid return to the initial value Radio Frequencies (RF): frequency range above 150 kHz rise time (of a pulse) (161-02-05): interval of time between the instants at which the instantaneous value of a pulse first reaches a specified lower value and then a specified upper value NOTE: Unless otherwise specified, the lower and upper values are fixed at 10 % and 90 % of the pulse magnitude.

secondary supply: supply to the telecommunications equipment (e.g. racks or system blocks), derived from the primary supply surge (voltage) (161-08-11): transient voltage wave propagating along a line or a circuit and characterized by a rapid increase followed by a slower decrease of the voltage system block: functional group of equipment depending for its operation and performance upon the secondary power supply telecommunication network: network operated under a licence granted by a national telecommunications authority, which provides telecommunications between Network Termination Points (NTPs) (i.e. excluding terminal equipment beyond the NTPs) tertiary supply: supply to the telecommunications equipment derived from the secondary supply transient (adjective or noun) (161-02-01): pertaining to or designating a phenomenon or a quantity which varies between two consecutive steady states during a time interval which is short compared with the timescale of interest

3.2 Abbreviations

For the purposes of the present document, the following abbreviations apply:

ADSL Asymmetric Digital Subscriber Line AM Amplitude Modulation ATM Asynchronous Transfer Mode CPU Central Processing Unit DC Direct Current DLU Digital Line Unit DSL Digital Subscriber Line EMC ElectroMagnetic Compatibility ESD Electrostatic Discharge EUT Equipment Under Test HDSL High bit-rate Digital Subscriber Line LTG Line Trunk Group NTPs Network Termination Points PDH Plesiochronous Digital Hierarchy PRBS Pseudo Random Bit Sequence RF Radio Frequency rms root-mean-square SDH Synchronous Digital Hierarchy ETSI

SIST EN 300 386 V1.3.3:2006

13 ETSI EN 300 386 V1.3.3 (2005-04)

SDSL Symmetrical single pair high bit rate Digital Subscriber Line SN Switching Network TLS Test Load Simulator T /T Rise time (10 % to 90 %) and hold time (50 % to 50 %) of transient signal (see EN 61000-4-4) r h TS Traffic Simulator U Voltage measured with a psophometer conforming to ITU-T Recommendation O.41 pso VDSL Very high speed Digital Subscriber Line

4 Installation environment

The installation environments for the equipment covered by the present document are defined in TR 101 651 [42]. The environments defined are either:

  • the telecommunication centre (major and minor);
  • locations other than telecommunication centre e.g. within offices, customers' premises, outdoor locations, etc. If no restrictions are specified in the product documentation for the installation environment, the equipment shall comply with the requirements of all environments, implying that the more severe test level shall be used when the test is performed.

5 Immunity: test methods

Where reference is made in the present document to specific "test levels" to be used for the tests, it is implicitly required that the EUT shall also fulfil the compliance criteria when tested at "test levels" lower than those specified. This requirement does not apply, however, to tests for immunity to continuous phenomena. Conducted immunity tests shall be applied to one port at a time. Conducted immunity test shall not be applied to the signal ports that, according to the product documentation, are not permanently connected.

One signal port of each type found on the equipment shall be tested. If in normal installation practice multi-pair cables (e.g. 64 × balanced pairs) and composite cables (e.g. a combination of fibre and copper) are used, they may be tested as one single cable. Cables bundled for aesthetic or routing purposes are to be tested individually. It may be determined from consideration of the electrical characteristics and usage of a particular equipment that some of the tests are inappropriate and therefore unnecessary. In such a case, it is required that both the decision and the justification not to apply any particular test to any particular port be recorded in the test report.

5.1 Electrostatic discharge

The immunity test method and laboratory conditions are described in EN 61000-4-2 [7]. ESD shall be applied only to those points and surfaces of the EUT that are expected to be touched during normal operation including users access as specified in the user manual. The application of discharges to any point of the equipment other than the electrostatic protection point, which is accessible only for maintenance purposes, is not required. The application of ESD to the contacts of open connectors is not required.

...