Abstract

This document specifies the general requirements for the preparation of samples, initial suspensions and further dilutions prior to microbiological examinations of soil improvers and growing media. This method is applicable especially for sample preparation prior to microbiological examinations of e.g. Escherichia coli (E. coli), Salmonella spp. and enterococci.
If a laboratory receives a material/product that is not listed in Annex B but has external characteristics (i.e. hardness, fibrous nature, particle size) like one of the materials/products listed in Annex B, then the procedural steps for sample preparation (pre-treatment, treatment and dilution) are carried out in the same way as listed for the material/product which has comparable external characteristics.
Any special diluents or practices required for particular materials or microorganisms in specific standard methods take priority over the general requirements listed in this document.

Status
Not Published
Public Enquiry End Date
14-Apr-2026
Technical Committee
KAT - Soil quality
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
29-Sep-2026
Due Date
17-Nov-2026
Completion Date
30-Oct-2026

Buy Documents

Draft

oSIST prEN 13040-2:2026

English language (18 pages)
Preview
Preview
e-Library read for
×1 day

kSIST FprEN 13040-2:2026 is the SIST publication of the draft European Standard prEN 13040-2 for soil improvers and growing media. It specifies how laboratories prepare samples, initial suspensions and further dilutions before microbiological examination, especially when testing for Escherichia coli (E. coli), Salmonella spp. and enterococci.

What does kSIST FprEN 13040-2:2026 specify?

kSIST FprEN 13040-2:2026 specifies the general requirements for sample preparation before microbiological examinations of soil improvers and growing media. It covers laboratory preparation only - sampling itself is handled separately by EN 12579 - and it gives priority to any special diluent or practice required by a specific microbiological method.

AnnexWhat it covers
Annex ACulture media and reagents
Annex BExample product types and the corresponding sample-preparation steps

The document is organized into clauses on scope, normative references, terms and definitions, principle, reagents, apparatus and equipment, transport and storage, and the step-by-step procedure. That structure matters in practice because the user first checks whether the material fits the scope, then follows the preparation route for the matrix and the microbiological purpose.

What are the key requirements of kSIST FprEN 13040-2:2026?

kSIST FprEN 13040-2:2026 separates the work into two different aims: detection and enumeration. Detection prepares a suspension for enrichment, while enumeration prepares an initial suspension and, if needed, further dilutions so colonies can be counted after incubation.

Sample receipt, transport and storage

Clause 7 requires the laboratory to receive a representative sample that has not been altered during transport or storage. Samples are stored cool, not frozen, and examined promptly, because the microbiome can change over time. In practice, this means the lab needs controlled storage and a fast workflow after receipt.

Taking the test portion

Clause 8.1 requires thorough homogenisation before the test portion is taken. The work must be done aseptically, incidental foreign matter such as stones or plastic must be removed, and the treatment depends on the physical form of the material. Pre-shaped products are sampled directly, rigid solids are reduced in size, and compressed blocks are crushed in their original dry state rather than reconstituted.

Choosing the right preparation route

Clause 8.2 and Annex B link matrix type to pre-treatment, homogenisation method and dilution behaviour. This is important because different materials - for example compost, peat, bark, coir, mineral products or liquids - behave differently in suspension. If a received material is not listed in Annex B but has similar external characteristics, the same procedural steps are used for the comparable material.

Suspensions, pH and dilution

Clause 8.2 requires suitable diluents at laboratory temperature to avoid thermal shock to microorganisms. For matrices that can shift pH strongly, such as bog peat, Sphagnum, alkaline composts or blended products rich in minerals, the initial suspension is checked and corrected to a pH range suitable for the organisms. For Salmonella detection and for enumeration of E. coli and enterococci, the document uses buffered peptone water (BPW) or other specified diluents, with more dilute preparation when swelling materials need extra liquid.

Apparatus and laboratory practice

Clause 6 points to the usual microbiological laboratory equipment and allows disposable equipment if it is suitable. It also highlights sterilization equipment, size-reduction tools, homogenizers, pipettes, accurate weighing and aseptic containers. This tells the laboratory what kind of setup is expected before routine testing starts.

Culture media and special methods

Annex A gives the culture media and reagents and reminds the user to follow manufacturer instructions. It also recommends checking media performance under the laboratory's own storage conditions and points to EN ISO 11133 for performance testing of culture media.

What terms does kSIST FprEN 13040-2:2026 define?

  • Laboratory sample - for microbiological testing, each separate segment sample intended for laboratory testing.
  • Test sample - the sample prepared from the laboratory sample from which test portions are taken, especially when one sample is used for more than one type of analysis.
  • Test portion - the amount of material actually taken for the test.
  • Initial suspension - the primary dilution obtained after the test portion is mixed with a diluent, normally in a nine-fold ratio.
  • Further dilution - a later dilution prepared from the initial suspension to build a dilution series suitable for inoculation and counting.

Who uses kSIST FprEN 13040-2:2026?

kSIST FprEN 13040-2:2026 is used by microbiology laboratories, quality control laboratories and technical staff who test soil improvers and growing media. It is also used by manufacturers, processors and suppliers of compost, peat, coir, bark, digestate, mineral growing media and similar products when they need a defined sample-preparation method before microbiological testing.

Quality managers and buyers use it to specify how samples should be handled before testing, especially when the result must support checks for E. coli, Salmonella spp. or enterococci. Laboratory supervisors use it to set aseptic handling, storage and dilution procedures.

Which standards are used with kSIST FprEN 13040-2:2026?

kSIST FprEN 13040-2:2026 relies on these companion documents:

  • EN 12579 - provides the sampling rules for soil improvers and growing media.
  • EN ISO 7218 - gives the general laboratory requirements and guidance for microbiological examinations.
  • prEN 17732 - supplies the terminology used in this series.
  • EN 13040-1 - is the other part of the EN 13040 series, covering sample preparation for chemical and physical tests.
  • EN ISO 11133 - is referenced in Annex A as the guide for preparation and performance testing of culture media.

What does the kSIST FprEN 13040-2:2026 document contain?

kSIST FprEN 13040-2:2026 contains step-by-step procedures for the test portion, the initial suspension, combined qualitative-quantitative workflows and further decimal dilutions. It also includes a warning on safe laboratory practice, plus practical guidance on aseptic handling and homogenisation.

The document gives the media and reagent information in Annex A and maps example product types to suitable pre-treatment and dilution approaches in Annex B. Figures 1 and 2 summarize the qualitative and quantitative workflows, while Table B.1 links product forms to the equipment and preparation route used in practice.

Buy Documents

Draft

oSIST prEN 13040-2:2026

English language (18 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

Control Union Certifications

Global certification for agriculture and sustainability.

RVA Netherlands Verified

ECOCERT

Organic and sustainability certification.

COFRAC France Verified

FSC International

Forest Stewardship Council certification.

ASI Germany Verified

Sponsored listings

Frequently Asked Questions

kSIST FprEN 13040-2:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Soil improvers and growing media - Sample preparation - Part 2: Sample preparation for microbiological examination". This standard covers: This document specifies the general requirements for the preparation of samples, initial suspensions and further dilutions prior to microbiological examinations of soil improvers and growing media. This method is applicable especially for sample preparation prior to microbiological examinations of e.g. Escherichia coli (E. coli), Salmonella spp. and enterococci. If a laboratory receives a material/product that is not listed in Annex B but has external characteristics (i.e. hardness, fibrous nature, particle size) like one of the materials/products listed in Annex B, then the procedural steps for sample preparation (pre-treatment, treatment and dilution) are carried out in the same way as listed for the material/product which has comparable external characteristics. Any special diluents or practices required for particular materials or microorganisms in specific standard methods take priority over the general requirements listed in this document.

This document specifies the general requirements for the preparation of samples, initial suspensions and further dilutions prior to microbiological examinations of soil improvers and growing media. This method is applicable especially for sample preparation prior to microbiological examinations of e.g. Escherichia coli (E. coli), Salmonella spp. and enterococci. If a laboratory receives a material/product that is not listed in Annex B but has external characteristics (i.e. hardness, fibrous nature, particle size) like one of the materials/products listed in Annex B, then the procedural steps for sample preparation (pre-treatment, treatment and dilution) are carried out in the same way as listed for the material/product which has comparable external characteristics. Any special diluents or practices required for particular materials or microorganisms in specific standard methods take priority over the general requirements listed in this document.

kSIST FprEN 13040-2:2026 is classified under the following ICS (International Classification for Standards) categories: 65.080 - Fertilizers. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN 13040-2:2026 is associated with the following European legislation: EU Directives/Regulations: 2019/1009; Standardization Mandates: M/564. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

kSIST FprEN 13040-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 laboratory sample
  • 3.2 test sample
  • 3.3 test portion
  • 3.4 initial suspension
  • 3.5 further dilution
  • 4 Principle
  • 5 Reagents
  • 6 Apparatus and equipment
  • 7 Transportation and storage of samples
  • 8 Procedure
  • 8.1 Preparation of the test portion
  • 8.2 Preparation of the initial suspension
  • 8.3 Further dilutions
  • Annex A
  • Annex B
  • Bibliography

1 Scope

This document specifies the general requirements for the preparation of samples, initial suspensions and further dilutions prior to microbiological examinations of soil improvers and growing media. This method is intended especially for sample preparation prior to microbiological examinations of e.g. Escherichia coli (E. coli), Salmonella spp. and enterococci.

If a laboratory receives a material/product that is not listed in Annex B but has external characteristics (i.e. hardness, fibrous nature, particle size) like one of the materials/products listed in Annex B, then the procedural steps for sample preparation (pre-treatment, treatment and dilution) are carried out in the same way as listed for the material/product which has comparable external characteristics. Any special diluents or practices required for particular materials or microorganisms in specific standard methods take priority over the general requirements listed in this document.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12579, Soil improvers and growing media - Sampling EN ISO 7218, Microbiology of the food chain - General requirements and guidance for microbiological examinations (ISO 7218)

prEN 17732, Soil improvers and growing media - Terminology

3 Terms and definitions

For the purposes of this document, the terms and definitions given in EN 12579, prEN 17732 and the following apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp/
  • IEC Electropedia: available at https://www.electropedia.org/

3.1 laboratory sample

in relation to chemical and physical testing, a final sample intended for laboratory testing and in relation to microbiological testing, each separate segment sample intended for laboratory testing

3.2 test sample

sample prepared from the laboratory sample (3.1) and from which test portions (3.3) are taken Note 1 to entry: A test sample is only necessary when the laboratory sample is used for multiple analysis (e.g. microbiological and chemical analysis). When multiple analyses are performed (e.g. microbiological and chemical analysis), appropriately sized test sample needs to be taken first for microbiological analysis in order to avoid contamination. The remaining test sample material shall be stored in a cool place for possible subsequent analyses. The remaining laboratory sample is thereafter passed on for chemical analyses, if necessary.

Under preparation. Stage at time of publication: prEN 17732:2025.

oSIST prEN 13040-2:2026 prEN 13040-2:2025 (E)

3.3 test portion

quantity of material drawn from the test sample or directly from the laboratory sample and on which the tests and observations are actually carried out

3.4 initial suspension

primary dilution obtained after the test portion (3.2) has been treated with, normally, a nine-fold quantity of diluent Note 1 to entry: A closer ratio between the diluent and the quantity of material is often not recommended because of possible inhibiting influences of the matrix.

3.5 further dilution

suspension or solution obtained by mixing a measured volume of the initial suspension (3.4) with an x- fold volume of diluent and by repeating this operation with further dilutions until a dilution series is obtained that is suitable for the inoculation of culture media Note 1 to entry: Normally ten-fold dilutions are used to yield a decimal dilution series, but other ratios may be required for specific purposes.

4 Principle

Sample preparation prior to microbiologal examination consists of two consecutive steps, for which the second step depends on the intent of the subsequent microbiological examination, meaning enumeration or detection.

1) Removal of a representative test portion (3.3) out of the test sample (3.2) or laboratory sample (3.1) after thorough homogenisation 2) Addition of the homogenic test portion to the dilution or enrichment medium and homogenisation 2a) For detection: Preparation of a suspension for the first enrichment in a way to obtain an as uniform as possible distribution of microorganisms contained in the test portion 2b) For enumeration: Preparation of an initial suspension in a way to obtain an as uniform as possible distribution of microorganisms contained in the test portion. Preparation, if necessary, of further dilutions in order to reduce the number of microorganisms per unit volume to allow counting of colonies on enumeration plates after incubation

5 Reagents

Follow current laboratory practices in accordance with standards comparable to EN ISO 7218. The composition of culture media and reagents and their preparation are specified in Annex A. For performance testing of culture media, it is advised to follow the procedures of EN ISO 11133.

6 Apparatus and equipment

Disposable equipment is an acceptable alternative to reusable glassware if it has suitable specifications. The usual microbiological laboratory equipment (see EN ISO 7218) and, in particular, the following shall be used.

6.1 Apparatus for dry sterilization (oven) or wet sterilization (autoclave).

oSIST prEN 13040-2:2026 prEN 13040-2:2025 (E) 6.2 Equipment for size reduction; apparatuses (aseptic) may include:

  • scissors;
  • tweezers;
  • spoons;
  • scalpels;
  • knives;
  • hammers (used with a sterile bag around the sample);
  • saws;
  • spatulas;
  • mortar and pestle.

6.3 Homogenization devices; apparatuses (aseptic) may include:

  • a magnetic stirrer with vessels and stirring bars ;
  • orbital shaker, with bottles (glass beads may be used in the case of viscous or thick materials);
  • peristaltic blender (paddle blender), with sterile plastic bags, preferable with a filter;
  • vortex mixer (for dilutions).

6.4 Other laboratory equipment; may include:

  • pipettes or pipettor and sterile tips, to dispense 1 ml to 10 ml with tips (with large opening if necessary);
  • scales and gravimetric dilution controllers, capable of weighing to 1 % of the mass;
  • aseptic containers (bowls, wide-mouth containers, developing tray) for homogenization of the laboratory sample.

7 Transportation and storage of samples

Sampling is not part of the method specified in this document. EN 12579 shall be followed for sampling soil improvers and growing media for microbiological examination. It is important that the laboratory receives a sample that is representative of the product under consideration. The sample shall not have been damaged or changed during transport or storage.

The samples as submitted to the laboratory, shall be stored and treated so that they shall not undergo any further decomposition, physical damage, hydration or dehydration. Samples shall be stored at 5 °C ± 3 °C, but not frozen.

It is recommended to examine the samples within 72 h after reception as the microbiome can change over time.

oSIST prEN 13040-2:2026 prEN 13040-2:2025 (E)

8 Procedure

8.1 Preparation of the test portion

WARNING — In order to safeguard the health of laboratory personnel, it is essential that the procedures described in this document are only undertaken in properly equipped laboratories, under the supervision of a skilled microbiologist, and that great care is taken in the disposal of all incubated materials. Persons using this document shall be familiar with normal laboratory practice. This document does not purport to address all of the safety aspects, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices.

All operations before and after opening the packaged material shall be carried out under aseptic conditions, to avoid any external contamination.

The types of packaged materials sent to the laboratory can be in flexible packaging. This shall be removed or opened aseptically.

NOTE There is no need to disinfect the packaging if the contents can be removed aseptically after opening without any risk of external contamination.

Before taking the test portion, the sample material of the laboratory sample or test sample shall be thoroughly homogenized so that representative sampling is possible. Liquid samples should be homogenized by shaking the container or stirring with an aseptic object. If possible, solid samples should be mixed in the packaging with an aseptic device. If this is not possible, the laboratory sample shall be transferred to an aseptic container (bowl, developing tray) and mixed. Remove any incidental pieces (e.g. stones, glass, plastic pieces) aseptically. The following special features shall be used:

  • For pre-shaped materials (e.g. mineral wool slabs, plugs): The test portion (3.3) is taken directly from the material, without “reconstitution” by addition of water.
  • For solid rigid materials (e.g. compost, bark): Solid materials shall be reduced in size to obtain a representative test portion (3.3) under aseptic conditions (6.1). The dimension of the pieces shall not exceed approximately 2 cm in all dimensions.

...