SIST EN 61000-5-7:2002
(Main)Electromagnetic compatibility (EMC) -- Part 5-7: Installation and mitigation guidelines - Degrees of protection by enclosures against electromagnetic disturbances (EM code)
Electromagnetic compatibility (EMC) -- Part 5-7: Installation and mitigation guidelines - Degrees of protection by enclosures against electromagnetic disturbances (EM code)
Describes performance requirements, test methods and classification procedures for degrees of protection provided by empty enclosures against electromagnetic disturbances for frequencies between 10 kHz and 40 GHz. The shielding protection is measured for the purpose of demonstrating that the enclosure provides adequate shielding of electromagnetic energy to support acceptable performance of the complete assembled units when tested to applicable IEC standards. The purpose of this standard is to provide a repeatable means for evaluating the electromagnetic shielding performance of empty mechanical enclosures, including cabinets and subracks, and to specify a marking code to allow a manufacturer to select an enclosure with a known capability for attenuating electromagnetic fields. The requirements for immunity to various types of electromagnetic disturbances, including lightning and high-altitude electro-magnetic pulse (HEMP) will need to be considered by manufacturers when determining the need for application of this standard for specific equipment and applications, and for the specific enclosure shielding requirements which are necessary as a function of frequency.
Elektromagnetische Verträglichkeit (EMV) -- Teil 5-7: Installationsrichtlinien und Abhilfemaßnahmen - Schutzarten durch Gehäuse gegen elektromagnetische Störgrößen (EM-Code)
Compatibilité électromagnétique (CEM) -- Partie 5-7: Guide d'installation et d'atténuation - Degrés de protection procurés par les enveloppes contre les perturbations électromagnétiques (Code EM)
Spécifie les prescriptions, les méthodes d'essai et de classification applicables aux degrés de protection contre les perturbations électromagnétiques offerts par des enveloppes vides, pour les fréquences comprises entre 10 kHz et 40 GHz. La protection par blindage est mesurée pour montrer que l'enveloppe fournit un blindage adéquat à l'épreuve de l'énergie électromagnétique pour assurer des caractéristiques de fonctionnement acceptables des unités assemblées complètes lorsqu'elles sont soumises aux essais selon les normes CEI applicables. La présente norme a pour objet de fournir un moyen reproductible pour l'évaluation des performances de blindage électromagnétique des enveloppes mécaniques vides y compris les coffrets et les bâtis et de spécifier un code de marquage pour permettre à un fabricant de choisir une enveloppe avec une capacité d'atténuer des champs électromagnétiques connue. Les prescriptions d'immunité pour différents types de perturbations électromagnétiques y compris les impulsions de foudre et électromagnétiques nucléaires à haute altitude (IEM-HA) seront examinées par les constructeurs lorsqu'ils détermineront le besoin d'application de la présente norme pour des équipements et des applications spécifiques et pour les prescriptions des enveloppes de blindage spécifiques nécessaires en fonction de la fréquence.
Electromagnetic compatibility (EMC) - Part 5-7: Installation and mitigation guidelines - Degrees of protection by enclosures against electromagnetic disturbances (EM code) (IEC 61000-5-7:2001)
General Information
- Status
- Published
- Publication Date
- 30-Apr-2002
- Technical Committee
- EMC - Electromagnetic compatibility
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-May-2002
- Due Date
- 01-May-2002
- Completion Date
- 01-May-2002
Frequently Asked Questions
SIST EN 61000-5-7:2002 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electromagnetic compatibility (EMC) -- Part 5-7: Installation and mitigation guidelines - Degrees of protection by enclosures against electromagnetic disturbances (EM code)". This standard covers: Describes performance requirements, test methods and classification procedures for degrees of protection provided by empty enclosures against electromagnetic disturbances for frequencies between 10 kHz and 40 GHz. The shielding protection is measured for the purpose of demonstrating that the enclosure provides adequate shielding of electromagnetic energy to support acceptable performance of the complete assembled units when tested to applicable IEC standards. The purpose of this standard is to provide a repeatable means for evaluating the electromagnetic shielding performance of empty mechanical enclosures, including cabinets and subracks, and to specify a marking code to allow a manufacturer to select an enclosure with a known capability for attenuating electromagnetic fields. The requirements for immunity to various types of electromagnetic disturbances, including lightning and high-altitude electro-magnetic pulse (HEMP) will need to be considered by manufacturers when determining the need for application of this standard for specific equipment and applications, and for the specific enclosure shielding requirements which are necessary as a function of frequency.
Describes performance requirements, test methods and classification procedures for degrees of protection provided by empty enclosures against electromagnetic disturbances for frequencies between 10 kHz and 40 GHz. The shielding protection is measured for the purpose of demonstrating that the enclosure provides adequate shielding of electromagnetic energy to support acceptable performance of the complete assembled units when tested to applicable IEC standards. The purpose of this standard is to provide a repeatable means for evaluating the electromagnetic shielding performance of empty mechanical enclosures, including cabinets and subracks, and to specify a marking code to allow a manufacturer to select an enclosure with a known capability for attenuating electromagnetic fields. The requirements for immunity to various types of electromagnetic disturbances, including lightning and high-altitude electro-magnetic pulse (HEMP) will need to be considered by manufacturers when determining the need for application of this standard for specific equipment and applications, and for the specific enclosure shielding requirements which are necessary as a function of frequency.
SIST EN 61000-5-7:2002 is classified under the following ICS (International Classification for Standards) categories: 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 61000-5-7:2002 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EC, 2014/30/EU, 89/336/EEC; Standardization Mandates: M/490. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase SIST EN 61000-5-7:2002 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.