Respiratory protective devices - Threads for facepieces - Part 2: Centre thread connection

This European Standard is applicable to centre threads for respiratory protective devices. This standard does not apply to diving equipment and to positive pressure demand breathing apparatus.

Atemschutzgeräte - Gewinde für Atemanschlüsse - Teil 2: Zentralgewindeanschluß

Diese Europäische Norm gilt für Zentralgewinde für Atemschutzgeräte. Diese Norm gilt nicht für Tauchgeräte und Geräte in Überdruckausführung.

Appareils de protection respiratoire - Filetages pour pieces faciales - Partie 2: Raccord a filetage central

La présente norme européenne est applicable aux filetages centraux des appareils de protection respiratoire. La présente norme ne s'applique ni aux appareils de plongée ni aux appareils isolants du type à la demande à pression positive.

Oprema za varovanje dihal – Navoji na maskah – 2. del: Povezava s središčnim navojem

General Information

Status
Published
Publication Date
30-Jun-1999
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Jul-1999
Due Date
01-Jul-1999
Completion Date
01-Jul-1999

Relations

Effective Date
01-Jul-1999

Overview

EN 148-2:1999 is a CEN (European Committee for Standardization) standard that specifies requirements for centre thread connections used on facepieces of respiratory protective devices. The standard covers the design intent and applicability for threaded facepiece fittings, ensuring safe, reliable mechanical and sealing interfaces between masks and filters or breathing hoses. It explicitly excludes diving equipment and positive pressure demand breathing apparatus.

Key Topics

The standard addresses essential technical topics for centre thread connections without prescribing specific proprietary designs. Topics typically covered include:

  • Thread geometry and form: standardized thread profiles and mating interfaces to ensure interchangeability between compatible facepieces and accessories.
  • Mechanical performance: strength, durability and resistance to wear under normal use conditions.
  • Sealing and leakage control: requirements to maintain airtight connections between facepiece and attached components.
  • Materials and corrosion resistance: suitable material properties for threads and threaded fittings to maintain performance and safety.
  • Dimensional tolerances and fit: tolerancing rules to ensure consistent mating across different manufacturers.
  • Marking and documentation: identification of compliant components and relevant information for users and procurement.
  • Testing and conformity: test methods to verify compliance with mechanical, sealing and dimensional requirements.

Note: EN 148-2 sets the framework and performance expectations for centre thread connections; it does not list numeric thread sizes or operational limits in this summary.

Applications

EN 148-2 is practical for organizations and roles involved in the design, manufacture, testing, procurement and use of respiratory protective equipment:

  • PPE manufacturers and designers: to design facepieces and connectors that are compatible and conformant with European requirements.
  • Test laboratories and certification bodies: to assess thread connections for compliance and safety approvals.
  • Occupational health and safety professionals: to specify compatible respiratory equipment for workplaces.
  • Procurement teams: to ensure purchased respirators and filters are interoperable and meet recognized standards.
  • Maintenance and repair: guidance for replacement parts and ensuring continued compatibility.

Related Standards

EN 148-2 is part of the EN 148 series addressing threads for facepieces. For complete system compliance, users should consult the broader EN 148 series and other respiratory protective device standards (e.g., standards covering complete facepieces, filters, and performance testing).

Keywords: EN 148-2, respiratory protective devices, centre thread connection, facepiece threads, CEN standard, PPE, thread interchangeability, respiratory connector standard.

Frequently Asked Questions

SIST EN 148-2:1999 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Respiratory protective devices - Threads for facepieces - Part 2: Centre thread connection". This standard covers: This European Standard is applicable to centre threads for respiratory protective devices. This standard does not apply to diving equipment and to positive pressure demand breathing apparatus.

This European Standard is applicable to centre threads for respiratory protective devices. This standard does not apply to diving equipment and to positive pressure demand breathing apparatus.

SIST EN 148-2:1999 is classified under the following ICS (International Classification for Standards) categories: 13.340.30 - Respiratory protective devices. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 148-2:1999 has the following relationships with other standards: It is inter standard links to SIST EN 148-2:1996. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 148-2:1999 is associated with the following European legislation: EU Directives/Regulations: 2016/425, 89/686/EEC; Standardization Mandates: M/BC/CEN/88/7. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 148-2:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-1999
2SUHPD]DYDURYDQMHGLKDO±1DYRMLQDPDVNDK±GHO3RYH]DYDVVUHGLãþQLP
QDYRMHP
Respiratory protective devices - Threads for facepieces - Part 2: Centre thread
connection
Atemschutzgeräte - Gewinde für Atemanschlüsse - Teil 2: Zentralgewindeanschluß
Appareils de protection respiratoire - Filetages pour pi
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...