Fixed capacitors for use in electronic equipment - Part 16: Sectional specification - Fixed metallized polypropylene film dielectric DC capacitors (IEC 60384-16:2019)

IEC 60384-16:2019 applies to fixed capacitors with metallized electrodes and poly­propylene dielectric for use in electronic equipment. These capacitors can have "self-healing properties" depending on conditions of use. They are mainly intended for use with direct voltage.
Capacitors for alternating voltage and pulse applications are not included, but are covered by IEC 60384-17. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. Capacitors for electrical shock hazard protection (covered by IEC 60065) and fluorescent lamp and motor capacitors are also excluded.

Festkondensatoren zur Verwendung in Geräten der Elektronik - Teil 16: Rahmenspezifikation: Festkondensatoren mit metallisierter Polypropylen-Folie als Dielektrikum für Gleichspannung (IEC 60384-16:2019)

Condensateurs fixes utilisés dans les équipements électroniques - Partie 16: Spécification intermédiaire - Condensateurs fixes our courant continu à diélectrique en film de polypropylène métallisé (IEC 60384-16:2019)

L'IEC 60384-16:2019 s'applique aux condensateurs fixes à électrodes métallisées et à diélectrique en polypropylène destinés aux équipements électroniques. Ces condensateurs peuvent avoir des propriétés "autocicatrisantes" en fonction des conditions d'utilisation. Ils sont principalement destinés à être utilisés dans des applications en tension continue.
Les condensateurs destinés à des applications en tension alternative et en impulsions ne sont pas inclus, mais ils sont couverts par l'IEC 60384-17. Les condensateurs d'antiparasitage ne sont pas inclus, mais ils sont couverts par l'IEC 60384-14. Les condensateurs de protection contre les chocs électriques (couverts par l'IEC 60065), ainsi que les condensateurs pour moteurs et pour lampes fluorescentes sont également exclus.

Nespremenljivi kondenzatorji za uporabo v elektronski opremi - 16. del: Področna specifikacija - Nespremenljivi kondenzatorji z dielektrikom iz metalizirane polipropilenske folije za enosmerne napetosti (IEC 60384-16:2019)

Ta del standarda se uporablja za nespremenljive kondenzatorje z metaliziranimi elektrodami in polipropilenskim dielektrikom za uporabo v elektronski opremi. Ti kondenzatorji imajo lahko »samoozdravljive lastnosti«, odvisno od pogojev uporabe. Večinoma so namenjeni uporabi z enosmerno napetostjo. Največja moč, ki se jo uporabi, je 500 var pri 50 Hz in največja temenska napetost je 2500 V. Zajeta sta naslednja dva razreda, in sicer a) razred 1 za dolgotrajno uporabo in b) razred 2 za splošno uporabo. Kondenzatorji za izmenično napetost in impulzno uporabo niso vključeni, vendar so zajeti v standardu IEC 60384-17. Kondenzatorji za preprečevanje elektromagnetnih motenj niso vključeni, vendar so zajeti v standardu IEC 60384-14. Izključeni so tudi kondenzatorji za zaščito pred električnim udarom (zajeti v standardu IEC 60065) ter kondenzatorji v fluorescenčnih sijalkah in motorjih.

General Information

Status
Published
Publication Date
27-Nov-2019
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
20-Nov-2019
Due Date
25-Jan-2020
Completion Date
28-Nov-2019

Relations

Standard
SIST EN IEC 60384-16:2020
English language
40 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-januar-2020
Nadomešča:
SIST EN 60384-16:2006
Nespremenljivi kondenzatorji za uporabo v elektronski opremi - 16. del: Področna
specifikacija - Nespremenljivi kondenzatorji z dielektrikom iz metalizirane
polipropilenske folije za enosmerne napetosti (IEC 60384-16:2019)
Fixed capacitors for use in electronic equipment - Part 16: Sectional specification - Fixed
metallized polypropylene film dielectric DC capacitors (IEC 60384-16:2019)
Festkondensatoren zur Verwendung in Geräten der Elektronik - Teil 16:
Rahmenspezifikation: Festkondensatoren mit metallisierter Polypropylen-Folie als
Dielektrikum für Gleichspannung (IEC 60384-16:2019)
Condensateurs fixes utilisés dans les équipements électroniques - Partie 16:
Spécification intermédiaire - Condensateurs fixes our courant continu à diélectrique en
film de polypropylène métallisé (IEC 60384-16:2019)
Ta slovenski standard je istoveten z: EN IEC 60384-16:2019
ICS:
31.060.10 Fiksni kondenzatorji Fixed capacitors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 60384-16

NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2019
ICS 31.060.30 Supersedes EN 60384-16:2005 and all of its
amendments and corrigenda (if any)
English Version
Fixed capacitors for use in electronic equipment - Part 16:
Sectional specification - Fixed metallized polypropylene film
dielectric DC capacitors
(IEC 60384-16:2019)
Condensateurs fixes utilisés dans les équipements Festkondensatoren zur Verwendung in Geräten der
électroniques - Partie 16: Spécification intermédiaire - Elektronik - Teil 16: Rahmenspezifikation:
Condensateurs fixes our courant continu à diélectrique en Festkondensatoren mit metallisierter Polypropylen-Folie als
film de polypropylène métallisé Dielektrikum für Gleichspannung
(IEC 60384-16:2019) (IEC 60384-16:2019)
This European Standard was approved by CENELEC on 2019-10-21. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 60384-16:2019 E

European foreword
The text of document 40/2686/FDIS, future edition 3 of IEC 60384-16, prepared by IEC/TC 40
"Capacitors and resistors for electronic equipment" was submitted to the IEC-CENELEC parallel vote
and approved by CENELEC as EN IEC 60384-16:2019.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2020-07-21
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2022-10-21
document have to be withdrawn
This document supersedes EN 60384-16:2005 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.

Endorsement notice
The text of the International Standard IEC 60384-16:2019 was approved by CENELEC as a European
Standard without any modification.

In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
IEC 60065 NOTE Harmonized as EN 60065
IEC 60068-2-20:2008 NOTE Harmonized as EN 60068-2-20:2008 (not modified)
IEC 60384-14 NOTE Harmonized as EN 60384-14
IEC 60384-17 NOTE Harmonized as EN IEC 60384-17

Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1  Where an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2  Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60063 -  Preferred number series for resistors and capacitors EN 60063 -
IEC 60068-1 2013 Environmental testing - Part 1: General and EN 60068-1 2014
guidance
IEC 60384-1 2016 Fixed capacitors for use in electronic equipment - EN 60384-1 2016
Part 1: Generic specification
IEC 61193-2 2007 Quality assessment systems - Part 2: Selection and EN 61193-2 2007
use of sampling plans for inspection of electronic
components and packages
IEC 60417 -  Graphical symbols for use on equipment. Index, - -
survey and compilation of the single sheets.
ISO 3 -  Preferred numbers - Series of preferred numbers - -

IEC 60384-16 ®
Edition 3.0 2019-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Fixed capacitors for use in electronic equipment –

Part 16: Sectional specification – Fixed metallized polypropylene film dielectric

DC capacitors
Condensateurs fixes utilisés dans les équipements électroniques –

Partie 16: Spécification intermédiaire – Condensateurs fixes pour courant

continu à diélectrique en film de polypropylène métallisé

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 31.060.30 ISBN 978-2-8322-7334-0

– 2 – IEC 60384-16:2019 © IEC 2019
CONTENTS
FOREWORD . 6
1 General . 8
1.1 Scope . 8
1.2 Object . 8
1.3 Normative references . 8
1.4 Information to be given in a detail specification . 9
1.4.1 General . 9
1.4.2 Outline drawing and dimensions . 9
1.4.3 Mounting . 9
1.4.4 Ratings and characteristics . 10
1.4.5 Marking . 10
1.5 Terms and definitions . 10
1.6 Marking . 11
1.6.1 General . 11
1.6.2 Information for marking . 11
1.6.3 Marking on capacitors . 11
1.6.4 Marking on packaging . 11
2 Preferred ratings and characteristics . 12
2.1 Preferred characteristics . 12
2.2 Preferred values of ratings . 12
2.2.1 Nominal capacitance (C ) . 12
N
2.2.2 Tolerances on nominal capacitance . 12
2.2.3 Nominal capacitance with associated tolerance values . 12
2.2.4 Rated voltage (U ) . 12
R
2.2.5 Category voltage (U ). 13
C
2.2.6 Rated temperature . 13
3 Quality assessment procedures . 13
3.1 Primary stage of manufacture . 13
3.2 Structurally similar components . 13
3.3 Certified records of released lots . 13
3.4 Qualification approval procedures . 13
3.4.1 General . 13
3.4.2 Qualification approval on the basis of the fixed sample size procedures . 13
3.5 Quality conformance inspection . 20
3.5.1 Formation of inspection lots . 20
3.5.2 Test schedule . 21
3.5.3 Delayed delivery . 21
3.5.4 Assessment levels . 21
4 Test and measurement procedures . 22
4.1 Visual examination and check of dimensions . 22
4.1.1 General . 22
4.1.2 Test conditions . 22
4.1.3 Requirements . 22
4.2 Electrical tests . 22
4.2.1 Voltage proof . 22
4.2.2 Capacitance . 23
4.2.3 Tangent of loss angle (tan δ) . 23

IEC 60384-16:2019 © IEC 2019 – 3 –
4.2.4 Insulation resistance . 24
4.2.5 Inductance (if required) . 26
4.2.6 Characteristics depending on temperature (if required) . 26
4.3 Robustness of terminations . 27
4.3.1 General . 27
4.3.2 Initial inspections . 27
4.3.3 Test method . 27
4.3.4 Final inspections . 27
4.4 Resistance to soldering heat . 27
4.4.1 General . 27
4.4.2 Preconditioning . 27
4.4.3 Test conditions . 27
4.4.4 Final inspections . 27
4.5 Solderability . 27
4.5.1 General . 27
4.5.2 Preconditioning . 28
4.5.3 Test conditions . 28
4.5.4 Final inspections . 28
4.6 Rapid change of temperature . 28
4.6.1 General . 28
4.6.2 Initial inspections . 28
4.6.3 Test conditions . 28
4.6.4 Recovery (if required) . 28
4.6.5 Final inspections . 28
4.7 Vibration . 28
4.7.1 General . 28
4.7.2 Mounting . 28
4.7.3 Test conditions . 28
4.7.4 Final inspections . 29
4.8 Bump (if required) . 29
4.8.1 General . 29
4.8.2 Mounting . 29
4.8.3 Initial inspections . 29
4.8.4 Test conditions . 29
4.8.5 Final inspections . 29
4.9 Shock (if required) . 29
4.9.1 General . 29
4.9.2 Mounting . 29
4.9.3 Initial inspections . 30
4.9.4 Test conditions . 30
4.9.5 Final inspections . 30
4.10 Climatic sequence. 30
4.10.1 General . 30
4.10.2 Initial inspections . 30
4.10.3 Dry heat . 30
4.10.4 Damp heat, cyclic, Test Db, first cycle . 30
4.10.5 Cold. 30
4.10.6 Low air pressure (if required) . 30
4.10.7 Damp heat, cyclic, Test Db, remaining cycles . 31

– 4 – IEC 60384-16:2019 © IEC 2019
4.11 Damp heat, steady state . 31
4.11.1 General . 31
4.11.2 Initial inspections . 31
4.11.3 Test conditions . 31
4.11.4 Recovery (if required) . 31
4.11.5 Final inspections . 32
4.11.6 Humidity robustness grades . 32
4.12 Endurance . 32
4.12.1 General . 32
4.12.2 Initial inspections . 32
4.12.3 Test conditions . 32
4.12.4 Recovery . 32
4.12.5 Final inspections . 32
4.13 Charge and discharge . 32
4.13.1 General . 32
4.13.2 Initial inspections . 32
4.13.3 Test conditions . 33
4.13.4 Recovery (if required) . 34
4.13.5 Final inspections . 34
4.14 Component solvent resistance . 34
4.15 Solvent resistance of the marking . 34
4.16 Sealing . 34
Annex A (normative) Humidity robustness grades for applications, where high stability
under high humidity operating conditions is required. 35
A.1 Scope . 35
A.2 Humidity robustness grades . 35
A.2.1 Standard . 35
A.2.2 Grade (I) robustness under humidity . 35
A.2.3 Grade (II) robustness under high humidity . 35
A.2.4 Grade (III) high robustness under high humidity . 35
A.3 Indication of humidity robustness grades . 36
Bibliography . 37

Table 1 – Preferred values . 11
Table 2 – Preferred combinations of capacitance value series and tolerances . 12
Table 3 – Sampling plan for qualification approval tests, assessment level EZ . 15
Table 4 – Test schedule for qualification approval . 16
Table 5 – Lot-by-lot inspection . 21
Table 6 – Periodic inspection . 22
Table 7 – Combinations of test point and test voltage . 23
Table 8 – Tangent of loss angle limits, 1 kHz . 24
Table 9 – Tangent of loss angle limits, 10 kHz . 24
Table 10 – Insulation resistance requirements . 25

IEC 60384-16:2019 © IEC 2019 – 5 –
Table 11 – Temperature coefficient factors . 25
Table 12 – Characteristics at lower category temperature . 26
Table 13 – Characteristics at upper category temperature . 27
Table 14 – Preferred severities . 30
Table 15 – Test conditions . 32
Table 16 – Lead spacing . 33

– 6 – IEC 60384-16:2019 © IEC 2019
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT –

Part 16: Sectional specification –
Fixed metallized polypropylene film dielectric DC capacitors

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60384-16 has been prepared by IEC technical committee 40:
Capacitors and resistors for electronic equipment.
This third edition cancels and replaces the second edition published in 2005. This edition
constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) revision of the structure in accordance with ISO/IEC Directives, Part 2: 2016 to the extent
practicable, and harmonization between other similar kinds of documents;
b) in addition, Clause 4 and all the tables have been reviewed in order to prevent
duplications and contradictions.

IEC 60384-16:2019 © IEC 2019 – 7 –
The text of this International Standard is based on the following documents:
FDIS Report on voting
40/2686/FDIS 40/2691/RVD
Full information on the voting for the approval of this International Standard can be found in
the report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
The list of all parts of the IEC 60384 series, under the general title Fixed capacitors for use in
electronic equipment, can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 8 – IEC 60384-16:2019 © IEC 2019
FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT –

Part 16: Sectional specification –
Fixed metallized polypropylene film dielectric DC capacitors

1 General
1.1 Scope
This part of IEC 60384 applies to fixed capacitors with metallized electrodes and poly-
propylene dielectric for use in electronic equipment.
These capacitors can have "self-healing properties" depending on conditions of use. They are
mainly intended for use with direct voltage.
The maximum power to be applied is 500 var at 50 Hz and the maximum peak voltage
is 2 500 V.
The following two grades are covered;
a) Grade 1: for long-life application;
b) Grade 2: for general application.
Capacitors for alternating voltage and pulse applications are not included, but are covered by
IEC 60384-17.
Capacitors for electromagnetic interference suppression are not included, but are covered by
IEC 60384-14.
Capacitors for electrical shock hazard protection (covered by IEC 60065) and fluorescent
lamp and motor capacitors are also excluded.
1.2 Object
The object of this document is to prescribe preferred ratings and characteristics and to select
from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring
methods and to give general performance requirements for this type of capacitor. Test
severities and requirements prescribed in detail specifications referring to this sectional
specification are of equal or higher performance level, because lower performance levels are
not permitted.
1.3 Normative references
The following documents are referred to in the text in such a way that some or all of their
content constitutes requirements of this document. For dated references, only the edition
cited applies. For undated references, the latest edition of the referenced document (including
any amendments) applies.
IEC 60063, Preferred number series for resistors and capacitors
IEC 60068-1:2013, Environmental testing – Part 1: General and guidance
IEC 60384-1:2016, Fixed capacitors for use in electronic equipment – Part 1: Generic
specification
IEC 60384-16:2019 © IEC 2019 – 9 –
IEC 61193-2:2007, Quality assessment system – Part 2: Selection and use of sampling plans
for inspection of electronic components and packages
IEC 60417, Graphical symbols for use on equipment (available at http://www.graphical-
symbols.info/equipment)
ISO 3, Preferred numbers – Series of preferred numbers
1.4 Information to be given in a detail specification
1.4.1 General
Detail specifications shall be derived from the blank detail specification.
Detail specifications shall not specify requirements inferior to those of the generic, sectional
or blank detail specification. When more severe requirements are included, they shall be
listed in 1.9 of the detail specification and indicated in the test schedules, for example by an
asterisk.
The information given in 1.4.2 may, for convenience, be presented in tabular form.
The following information shall be given in each detail specification and the values quoted
shall preferably be selected from those given in the appropriate clause of this sectional
specification.
1.4.2 Outline drawing and dimensions
There shall be an illustration of the capacitors as an aid to easy recognition and for
comparison of the capacitor with others.
Dimensions and their associated tolerances, which affect interchangeability and mounting,
shall be given in the detail specification. All dimensions shall preferably be stated in
millimetres; however, when the original dimensions are given in inches, the converted metric
dimensions in millimetres shall be added.
Normally, the numerical values shall be given for the length of the body, the width and height
of the body and the wire spacing, or for cylindrical types, the body diameter, and the length
and diameter of the terminals. When necessary, for example, when a number of items
(capacitance values/voltage ranges) are covered by a detail specification, the dimensions and
their associated tolerances shall be placed in a table below the drawing.
The numerical values of the body shall be given as follows:
– width, length and height, or for cylindrical types, diameter and length.
The numerical values of the terminals shall be given as follows:
– width or diameter, length and spacing.
When the configuration is other than described above, the detail specification shall state such
dimensional information as will adequately describe the capacitor.
1.4.3 Mounting
The detail specification shall specify the method of mounting to be applied for normal use and
for the application of the vibration and the bump or shock tests. The design of the capacitor
may be such that special mounting fixtures are required in its use. In this case, the detail
specification shall describe the mounting fixtures and they shall be used in the application of
the vibration and bump or shock tests.

– 10 – IEC 60384-16:2019 © IEC 2019
1.4.4 Ratings and characteristics
1.4.4.1 General
The ratings and characteristics shall be given in accordance with the relevant clauses of this
sectional specification, including the items as specified below.
1.4.4.2 Nominal capacitance range
See 2.2.1.
When products approved in accordance with the detail specification have different ranges, the
following statement should be added:
"The nominal capacitance range available in each voltage range is given in the register of
approvals, available for example on the IECQ on-line certificate system website
www.iecq.org”.
1.4.4.3 Particular characteristics
Additional characteristics may be listed, when they are considered necessary to specify
adequately the component for design and application purposes.
1.4.4.4 Soldering
The detail specification shall prescribe the test methods, severities and requirements
applicable for the solderability and the resistance to the soldering heat test.
1.4.5 Marking
The detail specification shall specify the content of the marking on the capacitor and on the
packaging. When there are deviations from 1.6, these shall be stated in the detail
specification.
1.5 Terms and definitions
For the purposes of this document, the terms and definitions of IEC 60384-1:2016 and the
following apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
1.5.1
performance grade 1 capacitors
capacitors intended for long-life applications with stringent requirements for the
electrical parameters
1.5.2
performance grade 2 capacitors
capacitors for general application where the stringent requirements for
grade 1 are not necessary
1.5.3
stability grade
capacitance drift after climatic and mechanical tests and after endurance tests

IEC 60384-16:2019 © IEC 2019 – 11 –
Note 1 to entry: The performance grade and the stability grade shall be noted in the detail specification.
1.5.4
performance grade and stability grade combinations
designation for combined performance grade and stability grade
SEE: Table 1
Table 1 – Preferred values
Performance Stability Combination
grade grade designation
1 1.1
2 1.2
2 – 2
Note 1 to entry: The three combinations of performance grades and stability grades concern capacitance stability
and tan δ values. Distinction in performance of the three combinations is shown in Table 4.
1.5.5
rated voltage
maximum DC voltage that can be applied continuously to a capacitor at the rated temperature
Note 1 to entry: The sum of the DC voltage and the peak AC voltage applied to the capacitor shall not exceed the
rated voltage. The value of the peak AC voltage allowed at different frequencies is under consideration.
1.6 Marking
1.6.1 General
See IEC 60384-1:2016, 2.4, with the following details.
1.6.2 Information for marking
Information given in the marking is normally selected from the following list; the relative
importance of each item is indicated by its position in the list:
a) nominal capacitance;
b) rated voltage (DC voltage may be indicated by the symbol     (IEC 60417-5031-2002-
10) or     );
c) tolerance on rated capacitance;
d) year and month (or, year and week) of manufacture;
e) manufacturer's name and/or trademark;
f) climatic category;
g) manufacturer's type designation;
h) reference to the detail specification.
1.6.3 Marking on capacitors
The capacitor shall be clearly marked with a), b) and c) above and with as many as possible
of the remaining items as is considered necessary. Any duplication of information in the
marking on the capacitor should be avoided.
1.6.4 Marking on packaging
The packaging containing the capacitors should be clearly marked with all the information
listed in 1.6.2 as necessary.
– 12 – IEC 60384-16:2019 © IEC 2019
2 Preferred ratings and characteristics
2.1 Preferred characteristics
Preferred climatic categories only shall be given in the preferred characteristics.
The capacitors covered by this sectional specification are classified into climatic categories in
accordance with the general rules given in IEC 60068-1:2013, Annex A.
The lower and upper category temperatures and the duration of the damp heat, steady-state
test shall be chosen from the following:
Lower category temperature: −55 °C, −40 °C, −25 °C and −10 °C;
Upper category temperature: +70 °C, +85 °C, +100 °C and +105 °C;
Duration of the damp heat, steady-state test: 4, 10, 21 and 56 days.
The severities for the cold and dry heat tests are the lower and upper category temperatures,
respectively.
2.2 Preferred values of ratings
2.2.1 Nominal capacitance (C )
N
Preferred values of nominal capacitance shall be taken from the E series of IEC 60063.
2.2.2 Tolerances on nominal capacitance
Preferred tolerances on the nominal capacitance are;
±20 %, ±10 %, ±5 %, ±2 % and ±1 %.
2.2.3 Nominal capacitance with associated tolerance values
For preferred combinations of capacitance, series and tolerances are shown in Table 2.
Table 2 – Preferred combinations of capacitance value series
and tolerances
Preferred combinations
Series Tolerances
E 6 ±20 %
E 12 ±10 %
E 24 ±5 %
E 48 ±2 %
E 96 ±1 %
2.2.4 Rated voltage (U )
R
The preferred values of rated voltages taken from the R5 series of ISO 3 are:
40 V − 63 V − 100 V − 160 V − 250 V − 400 V − 630 V − 1 000 V − 1 600 V − 2 500 V.

IEC 60384-16:2019 © IEC 2019 – 13 –
2.2.5 Category voltage (U )
C
The category voltage is equal to the rated voltage U for upper category temperatures up
R
to 85 °C. For an upper category temperature of > 85 °C, the category voltage is 0,7 U .
R
2.2.6 Rated temperature
The standard value for rated temperature is 85 °C. Except for an upper category temperature
of 70 °C where the rated temperature is 70 °C.
3 Quality assessment procedures
3.1 Primary stage of manufacture
The primary stage of manufacture is the winding of the capacitor element or the equivalent
operation.
3.2 Structurally similar components
Capacitors considered as being structurally similar are capacitors produced with similar
processes and materials, though they can be of different case sizes, capacitance and voltage
values.
3.3 Certified records of released lots
The information required in IEC 60384-1:2016, Q.1.5, shall be made available when
prescribed in the detail specification and when requested by a purchaser. After the endurance
test, the required parameters are the capacitance change, tangent of loss angle and the
insulation resistance.
3.4 Qualification approval procedures
3.4.1 General
The procedures for qualification approval testing are given in IEC 60384-1:2016, Clause Q.2.
The schedule to be used for qualification approval testing on the basis of lot-by-lot and
periodic tests is given in 3.5. The procedure using a fixed sample size schedule is given
in 3.4.2.
3.4.2 Qualification approval on the basis of the fixed sample size procedures
3.4.2.1 Sampling
The fixed sample size procedure is described in IEC 60384-1:2016, Q.2.4. The sample shall
be representative of the range of capacitors for which approval is sought. This may be the
whole or the part of the range given in the detail specification.
The sample shall consist of specimens having the maximum and minimum voltages, and, for
these voltages, the maximum and minimum capacitances. When there are more than four
rated voltages, an intermediate voltage shall also be tested. Thus, for the approval of a range,
testing is required of either four or six values (capacitance/voltage combinations). When the
range consists of fewer than four values, the number of specimens to be tested shall be that
required for four values.
a) Two (for 6 values) or three (for 4 values) per value may be used as replacements for
specimens, which are non-conforming because of incidents not attributable to the
manufacturer.
– 14 – IEC 60384-16:2019 © IEC 2019
The numbers given in Group 0 assume that all groups are applicable. If this is not so, the
numbers may be reduced accordingly.
When additional groups are introduced into the qualification approval test schedule, the
number of specimens required for Group 0 shall be increased by the same number as that
required for the additional groups.
Table 3 gives the number of samples to be tested i
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...