Abstract

This document specifies a method for extraction, separation, and determination of inorganic arsenic (iAs) in growing media and soil improvers using anion-exchange high performance liquid chromatography (HPLC) or ion chromatography (IC) coupled to ICP-MS.
This document is applicable to the fertilizing product blends where a blend is a mix of two or more fertilizing products belonging to the categories of fertilizers, liming material, soil improvers, growing media, inhibitors and plant biostimulants, and where soil improvers and/or growing media are the components with the highest percentage in the blend by mass or volume, or in the case of products in liquid form by dry mass. If the soil improvers and/or growing media are not the components with the highest percentage in the blend, the document relevant to the component with the highest percentage in the blend applies. In case a blend is composed of fertilizing products mixed in equal quantities, the user of the document decides which standard to apply. 
NOTE 1   A soil improver consists of a single bulky (volume-building) component or a mix of bulky (volume-building) components (for example peat, wood fibres, coconut coir, compost, expanded perlite).
NOTE 2   This method has been validated in an interlaboratory study with specific products that were present on the market during the study (as included in Annex B, being biowaste compost (dry, solid, spiked sample), digestate solid (dry, original sample), digestate liquid (spiked sample), growing media blend ((peat, green compost, wood fibre, liming material and inorganic fertilizer (NPK + elements)) dry, solid, spiked sample).

Status
Not Published
Public Enquiry End Date
19-Dec-2025
Technical Committee
KAT - Soil quality
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
09-Oct-2026
Due Date
27-Nov-2026

Buy Documents

Draft

oSIST prEN 18254:2025 - BARVE

English language (19 pages)
Preview
Preview
e-Library read for
×1 day

kSIST FprEN 18254:2026 is a draft European Standard from CEN for determining inorganic arsenic (iAs) in growing media and soil improvers. It specifies an extraction, chromatographic separation and ICP-MS measurement method, and it also applies to certain fertilizing product blends when soil improvers and/or growing media are the main components. Laboratories use it to measure iAs in materials that are placed on the market under the EU fertilising products framework.

What does kSIST FprEN 18254:2026 specify?

kSIST FprEN 18254:2026 specifies a method for the extraction, separation and determination of inorganic arsenic in growing media and soil improvers using anion-exchange HPLC or ion chromatography (IC) coupled to ICP-MS. The document also covers some fertilizing product blends, but only when soil improvers and/or growing media are the components with the highest percentage by mass, volume, or dry mass for liquid products.

kSIST FprEN 18254:2026 is organized into clauses 1 to 11, covering scope, normative references, terms, principle, reagents, apparatus, sampling, procedure, calculation, test report and validation. Annex A gives chromatographic examples, and Annex B gives validation data.

AnnexWhat it covers
Annex AExamples of typical chromatographic separation, including a chromatogram showing chloride interference control
Annex BPerformance characteristics from the interlaboratory validation study

The scope also points users to EN 12579:2024 for sampling, because sampling is not part of the analytical method itself. That matters in practice because a good measurement cannot recover information lost through poor sampling or transport.

What are the key requirements of kSIST FprEN 18254:2026?

kSIST FprEN 18254:2026 is built around a controlled extraction of the arsenic species, separation of inorganic arsenic from other arsenic compounds, and quantification by ICP-MS. The method is meant for routine laboratory work, but it depends on careful sample handling, blank control and chromatographic separation.

Sample handling and extraction

Clause 8.1 says the work must be done by suitably trained staff using normal laboratory safety practice. Clause 7 says sampling follows EN 12579:2024, and clause 8.2 says solid samples are ground and homogenized according to prEN 13040-1:2025, while liquid samples are mixed thoroughly. In practice, the result is only meaningful if the submitted sample is representative and has not changed during transport or storage.

Clause 8.3 describes extraction in a heated water bath after adding the extraction solution to a weighed test portion. The extract is then cooled, centrifuged and filtered before analysis, and a reagent blank is included with the samples. This is important because contamination, poor wetting or incomplete extraction can bias the iAs result.

Reagents, calibration and instrument setup

Clauses 5 and 6 emphasize low-contamination reagents, clean ware and suitable chromatographic and mass-spectrometric equipment. The mobile phase, calibration standards and samples must be prepared so that arsenic in the reagents does not influence the measurement. In practice, blank control is not optional when ICP-MS is used at low levels.

Clause 8.4 uses external calibration with a blank and at least three calibration standards in the working range. Clause 8.5.1 says the instrument conditions depend on the HPLC and ICP-MS systems used, so the operator must follow the manufacturer instructions and make the system stable before starting the run. This means laboratories need a validated setup, not just a working instrument.

Separation, interferences and quality control

Clause 8.5.2 focuses on chromatographic separation of arsenate from other arsenic species and on avoiding chloride interference. The document recommends checking separation with a suitable check solution, watching the chloride signal, and adjusting the chromatographic conditions if arsenate and chloride do not separate well enough. In practice, this is what protects the method from false high results caused by spectral interference.

Clause 8.5.2.3 requires blank test solutions, test samples and control samples to be analysed under the same conditions, with suitable dilution if the extract is too concentrated or the matrix suppresses the response. The clause also calls for internal reference materials or spike recovery checks. That matters because matrix effects are common in soil improvers and growing media, and the analyst needs evidence that the run behaved correctly.

Calculation and reporting

Clause 9 says the result is calculated from the calibration curve and expressed as inorganic arsenic on a dry matter basis. The calculation also allows for blank subtraction and dilution correction. In practice, the laboratory has to keep track of the sample mass, dilution steps and dry matter content, otherwise the reported mg/kg value will not be traceable.

Clause 10 sets the minimum test report content: sample identification, the method reference, the result, sampling information if known, the analysis date, and any optional steps or incidents that could have influenced the outcome. This is the part that supports audits, supplier communication and regulatory traceability.

Validation and performance

Clause 11 states that the method was validated according to ISO 5725-2, and Annex B presents repeatability and reproducibility data from an interlaboratory study. The validation covered four different materials representing soil improvers and growing media. For users, that means the document provides performance data they can compare with their own quality objectives or uncertainty needs.

What terms does kSIST FprEN 18254:2026 define?

  • Analyte - the parameter to be determined; in this document, the analyte is inorganic arsenic.
  • Blank calibration solution - a calibration solution prepared in the same way as the regular calibration solution but without analytes, used to define the zero point.
  • Blank test solution - a solution prepared like the test sample solution but without the test portion, used to check contamination from reagents and handling.
  • Calibration solution - a solution used to calibrate the instrument, made from stock solutions and prepared with acids, buffer, reference element and salts as needed.
  • Stock solution - a solution with a known analyte concentration, prepared from pure chemicals and used to make calibration solutions.
  • Inorganic arsenic (iAs) - the arsenic fraction measured by the method, made up of arsenite As(III) and arsenate As(V).

Who uses kSIST FprEN 18254:2026?

kSIST FprEN 18254:2026 is used by analytical laboratories, method developers and quality control teams that test soil improvers, growing media and qualifying fertilizing product blends. It is also relevant to manufacturers, suppliers and conformity assessment teams that need analytical data for product release, specification checking or market access work under the EU fertilising products framework mentioned in the introduction.

In practice, the main tasks are sample preparation, instrumental analysis, validation, routine batch testing and preparation of defensible test reports. The method also supports organizations that need comparable results across suppliers, laboratories and product types.

Which standards are used with kSIST FprEN 18254:2026?

  • CEN/TS 17732:2022 - provides the terminology used for soil improvers and growing media.
  • EN 12579:2024 - gives the sampling procedure for soil improvers and growing media.
  • prEN 13040-1:2025 - covers sample preparation and the dry matter basis used in the calculation.
  • ISO 5725-2 - provides the framework for validating repeatability and reproducibility.
  • prEN 13650:2025 - is mentioned in the principle as a preliminary aqua regia extraction method that can be used to screen total extractable arsenic before deciding whether iAs determination is needed.

The bibliography also points to related arsenic-speciation standards for foodstuffs, animal feed and plant biostimulants, which were studied as background for this method.

What does the kSIST FprEN 18254:2026 document contain?

kSIST FprEN 18254:2026 contains the analytical principle, the reagent list, the required apparatus, the sampling note, the extraction procedure, calibration preparation, measurement conditions, calculation steps and the test report content. It also includes a validation section tied to ISO 5725-2.

Table 1 gives example HPLC-ICP-MS settings. Annex A provides chromatogram examples that show separation of arsenic species and chloride interference checking, while Annex B gives the interlaboratory performance data for four materials.

Clause 9 includes formulae for calculating iAs on a dry matter basis, including dilution correction and blank subtraction. Those formulae are the part users need when they turn instrument output into a reportable mg/kg result for testing, compliance work or internal quality control.

Buy Documents

Draft

oSIST prEN 18254:2025 - BARVE

English language (19 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

Control Union Certifications

Global certification for agriculture and sustainability.

RVA Netherlands Verified

ECOCERT

Organic and sustainability certification.

COFRAC France Verified

FSC International

Forest Stewardship Council certification.

ASI Germany Verified

Sponsored listings

Frequently Asked Questions

kSIST FprEN 18254:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Soil improvers and growing media - Determination of the inorganic arsenic content". This standard covers: This document specifies a method for extraction, separation, and determination of inorganic arsenic (iAs) in growing media and soil improvers using anion-exchange high performance liquid chromatography (HPLC) or ion chromatography (IC) coupled to ICP-MS. This document is applicable to the fertilizing product blends where a blend is a mix of two or more fertilizing products belonging to the categories of fertilizers, liming material, soil improvers, growing media, inhibitors and plant biostimulants, and where soil improvers and/or growing media are the components with the highest percentage in the blend by mass or volume, or in the case of products in liquid form by dry mass. If the soil improvers and/or growing media are not the components with the highest percentage in the blend, the document relevant to the component with the highest percentage in the blend applies. In case a blend is composed of fertilizing products mixed in equal quantities, the user of the document decides which standard to apply.  NOTE 1 A soil improver consists of a single bulky (volume-building) component or a mix of bulky (volume-building) components (for example peat, wood fibres, coconut coir, compost, expanded perlite). NOTE 2 This method has been validated in an interlaboratory study with specific products that were present on the market during the study (as included in Annex B, being biowaste compost (dry, solid, spiked sample), digestate solid (dry, original sample), digestate liquid (spiked sample), growing media blend ((peat, green compost, wood fibre, liming material and inorganic fertilizer (NPK + elements)) dry, solid, spiked sample).

This document specifies a method for extraction, separation, and determination of inorganic arsenic (iAs) in growing media and soil improvers using anion-exchange high performance liquid chromatography (HPLC) or ion chromatography (IC) coupled to ICP-MS. This document is applicable to the fertilizing product blends where a blend is a mix of two or more fertilizing products belonging to the categories of fertilizers, liming material, soil improvers, growing media, inhibitors and plant biostimulants, and where soil improvers and/or growing media are the components with the highest percentage in the blend by mass or volume, or in the case of products in liquid form by dry mass. If the soil improvers and/or growing media are not the components with the highest percentage in the blend, the document relevant to the component with the highest percentage in the blend applies. In case a blend is composed of fertilizing products mixed in equal quantities, the user of the document decides which standard to apply.  NOTE 1 A soil improver consists of a single bulky (volume-building) component or a mix of bulky (volume-building) components (for example peat, wood fibres, coconut coir, compost, expanded perlite). NOTE 2 This method has been validated in an interlaboratory study with specific products that were present on the market during the study (as included in Annex B, being biowaste compost (dry, solid, spiked sample), digestate solid (dry, original sample), digestate liquid (spiked sample), growing media blend ((peat, green compost, wood fibre, liming material and inorganic fertilizer (NPK + elements)) dry, solid, spiked sample).

kSIST FprEN 18254:2026 is classified under the following ICS (International Classification for Standards) categories: 65.080 - Fertilizers. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN 18254:2026 is associated with the following European legislation: EU Directives/Regulations: 2003/2003, 2019/1009; Standardization Mandates: M/564, M/564 AMD 1, M/564 AMD 2, M/588, M/XXX. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

kSIST FprEN 18254:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
oSIST prEN 18254:2025
01-december-2025
Izboljševalci tal in rastni substrati - Določanje anorganskega arzena
Soil improvers and growing media - Determination of the inorganic arsenic content
Bodenverbesserungsmittel und Kultursubstrate - Bestimmung des anorganischen
Arsengehalts
Amendements du sol et supports de culture - Détermination de la teneur en arsenic
inorganique
Ta slovenski standard je istoveten z: prEN 18254
ICS:
65.080 Gnojila Fertilizers
oSIST prEN 18254:2025 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN 18254:2025
oSIST prEN 18254:2025
DRAFT
EUROPEAN STANDARD
prEN 18254
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2025
ICS 65.080
English Version
Soil improvers and growing media - Determination of the
inorganic arsenic content
Amendements du sol et supports de culture - Bodenverbesserungsmittel und Kultursubstrate -
Détermination de la teneur en arsenic inorganique Bestimmung des anorganischen Arsengehalts
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 223.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 18254:2025 E
worldwide for CEN national Members.

oSIST prEN 18254:2025
prEN 18254:2025 (E)
Contents Page
European foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Principle . 6
5 Reagents . 6
6 Apparatus . 8
7 Sampling . 9
8 Procedure . 9
8.1 Safety . 9
8.2 Sample preparation . 9
8.3 Water bath extraction . 9
8.4 Preparation of the calibration solutions . 10
8.5 Measurement . 10
8.5.1 General instrumental conditions . 10
8.5.2 HPLC-ICP/MS measurement of inorganic arsenic . 11
9 Calculation and expression of the results . 12
9.1 Integration of peaks . 12
9.2 Calculation of inorganic arsenic in the samples . 13
10 Test report . 13
11 Validation of the method . 14
11.1 Validation in accordance with ISO 5725-2. 14
11.2 Performance characteristics. 14
Annex A (informative) Examples of typical chromatographic separation . 15
Annex B (informative) Performance characteristics of the method . 17
Bibliography . 19

oSIST prEN 18254:2025
prEN 18254:2025 (E)
European foreword
This document (prEN 18254:2025) has been prepared by Technical Committee CEN/TC 223 “Soil
improvers and growing media”, the secretariat of which is held by NEN.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a standardization request addressed to CEN by the European
Commission. The Standing Committee of the EFTA States subsequently approves these requests for its
Member States.
oSIST prEN 18254:2025
prEN 18254:2025 (E)
Introduction
This document was prepared by the experts of CEN/TC 223 “Soil improvers and growing media”. The
European Committee for Standardization (CEN) was requested by the European Commission (EC) to
draft European standards or European standardization deliverables to support the implementation of
Regulation (EU) 2019/1009 of 5 June 2019 laying down rules on the making available on the market of
EU fertilizing products (“FPR” or “Fertilising Products Regulation”) [8].
This standardization request, presented as M/564, also contributes to the Communication on “Innovating
for Sustainable Growth: A Bio economy for Europe”. The Working Group 4 “Analytical methods” was
requested to develop a work programme as part of this request. The technical committee CEN/TC 223
“Soil improvers and growing media” was requested to carry out the work programme that will prepare a
series of standards. The interest in soil improvers and growing media has increased significantly in
Europe as a valuable tool to use in agriculture. Standardization was identified as having an important role
in order to promote the use of soil improvers and growing media. The work of CEN/TC 223 seeks to
improve the reliability of the supply chain, thereby boosting the confidence of farmers, industry and
consumers in soil improvers and growing media and will promote and support commercialisation of the
European fertilizer industry. The preparation of this document is based on a standardization request to
CEN by the European Commission and the European Free Trade Association (Mandate M/564)
concerning the modernization of methods of analysis of fertilizers in the framework of Regulation (EU)
2019/1009 of the European Parliament and of the Council.
This document describes a procedure of extraction and measurement for the determination of inorganic
arsenic in growing media and soil improvers. The document is based on a mild acid oxidative extraction
of the arsenic species followed by liquid chromatography (High Performance Liquid Chromatography –
HPLC) or Ion Chromatography (IC) coupled to the element-specific detector Inductively Coupled Plasma
Mass Spectrometry (ICP-MS) for the determination of the mass fraction of inorganic arsenic.
The other standards developed for determination of inorganic arsenic content in animal feeding stuffs,
foodstuffs and plant biostimulants were studied as a basis of the described method [2], [3], [4], [5], [6].
oSIST prEN 18254:2025
prEN 18254:2025 (E)
1 Scope
This document specifies a method for extraction, separation, and determination of inorganic arsenic (iAs)
in growing media and soil improvers using anion-exchange high performance liquid chromatography
(HPLC) or ion chromatography (IC) coupled to ICP-MS.
This document is applicable to the fertilizing product blends where a blend is a mix of two or more
fertilising products belonging to the categories of fertilizers, liming material, soil improvers, growing
media, inhibitors and plant biostimulants, and where soil improvers and/or growing media are the
components with the highest percentage in the blend by mass or volume, or in the case of products in
liquid form by dry mass. If the soil improvers and/or growing media are not the components with the
highest percentage in the blend, the document relevant to the component with the highest percentage in
the blend applies. In case a blend is composed of fertilising products mixed in equal quantities, the user
of the document decides which standard to apply.
NOTE A soil improver consists of a single bulky (volume-building) component or a mix of bulky (volume-
building) components (for example peat, wood fibres, coconut coir, compost, expanded perlite).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
CEN/TS 17732:2022, Soil improvers and growing media - Terminology
EN 12579:2024, Soil improvers and growing media - Sampling
prEN 13040-1:2025, Soil improvers and growing media — Sample preparation — Part 1: Sample
preparation for chemical and physical tests, determination of dry matter content, moisture content and
laboratory bulk density
3 Terms and definitions
For the purposes of this document, the terms and definitions given in CEN/TS 17732:2022 and the
following apply.
3.1
analyte
parameter to be determined
3.2
blank calibration solution
solution prepared in the same way as the calibration solution but leaving out the analytes
3.3
blank test solution
solution prepared in the same way as the test sample solution but omitting the test portion
3.4
calibration solution
solution used to calibrate the instrument, prepared from stock solutions by adding acids, buffer, reference
element and salts as needed
oSIST prEN 18254:2025
prEN 18254:2025 (E)
3.5
stock solution
solution with accurately known analyte concentration(s), prepared from pure chemicals
4 Principle
This document describes a method for the determination of inorganic arsenic in growing media and soil
improvers. Inorganic arsenic consists of arsenite As (III) and arsenate As (V). A representative test
portion of the sample is treated with a diluted nitric acid and hydrogen peroxide solution in a heated
water bath. By this means the sample is solubilised, arsenic species are extracted into solution and As (III)
is oxidized to As (V). The inorganic arsenic is selectively separated from other arsenic compounds using
anion exchange HPLC (High Performance Liquid Chromatography) coupled online to the element-specific
detector ICP-MS (Inductively Coupled Plasma Mass Spectrometer) for the determination of the mass
fraction of the inorganic arsenic. External calibration with solvent matrix-matched standards is used for
the quantification of the amount of the inorganic arsenic. Alternatively, IC (ion chromatography) coupled
to ICP-MS may be used.
A preliminary determination of the total arsenic in aqua regia extracts according to prEN 13650:2025 by
ICP-AES (WI 00223142:2025), can reduce the number of the samples where the determination of iAs is
necessary because if the content of aqua regia (total) extractable arsenic is lower than the legislative limit
for iAs (e.g. [8]) then the determination of iAs is not necessary.
To prove the compliance with existing limit values for inorganic arsenic in soil improvers and growing
media, there is the possibility to choose between:
— Using a testing method determining the aqua regia (total) extractable arsenic content, as long as the
result of the test shows a content below the limit value for inorganic arsenic. In such a case, it may be
safely assumed that soil improvers and growing media comply with the limit value for inorganic
arsenic.
— Using a testing method which determines only inorganic arsenic content.
In case aqua regia extractable (total) As is measured and is presented above or equal the legislative limit
for iAs, the content of inorganic As shall be determined according to this document.
5 Reagents
When using a method of high sensitivity such as ICP-MS and HPLC, the control of the blank levels of water,
acid and other reagents is very important. The reagents shall be of adequate purity and of recognized
analytical grade. The concentration of arsenic species in the reagents and water used shall be negligible
and low enough not to affect the results of the determination. Generally, ultra-pure water from a
purification system and nitric acid of minimum p.a. quality is recommended.
5.1 Water with an electrical conductivity not higher than 0,1 mS/m at 25 °C.
5.2 Nitric acid (HNO ), concentrated, ≥ 65 % (mass fraction), mass concentration of approximately
ρ (HNO ) 1,4 g/ml.
Use only nitric acid available with high purity (minimum p.a. quality) in order to avoid potential
contamination.
5.3 Hydrogen peroxide (H O ), not less than 30 % (mass fraction).
2 2
High purity is essential to avoid potential contamination. Commercially available hydrogen peroxide for
analysis should be tested for contamination of arsenic prior to use. It is necessary to prevent peroxide
degradation and ensure the stability of the solution.
oSIST prEN 18254:2025
prEN 18254:2025 (E)
5.4 Extraction solution, 0,1 mol/l HNO in 3 % (volume fraction) H O .
3 2 2
Add 6,5 ml of HNO (5.2) and thereafter 100 ml of hydrogen peroxide (5.3) into 800 ml water (5.1) in a
1 000 ml volumetric flask. Fill the flask to the mark with water (5.1). This solution is prepared on the day
of use.
It is recommended that the total volume needed for the analysis is estimated and only this amount is
produced in the day of use.
5.5 Ammonium carbonate ((NH ) CO ), mass fraction w ≥ 99,999 %, for preparation of the mobile
4 2 3
phase solution.
5.6 Aqueous ammonia (NH3(aq.)), mass fraction w ≥ 25 %, for adjustment of pH in the mobile phase.
5.7 Methanol (CH OH), HPLC grade, for preparation of the mobile phase solution.
5.8 Mobile phase, e.g. 50 mmol/l ammonium carbonate in 3 % (volume fraction) methanol at pH 10,3.
Dissolve 4,80 g of ammonium carbonate (5.5) in approximately 800 ml water (5.1). Adjust the pH to 10,3
with aqueous ammonia (5.6) and add 30 ml of methanol (5.7) and then fill up to 1 000 ml with water
(5.1). Prior to use filter the mobile phase solution through a 0,45 μm filter using a filtering device (6.4).
The optimal concentration of ammonium carbonate in the mobile phase depends on the analytical column
used (e.g. brand, particle size and dimensions) and should be verified in advance. The appropriate
concentration of ammonium carbonate (usually between 10 mmol/l to 50 mmol/l) is highly dependent
on the column used and is up to the discretion of the analyst. It should fulfil the criteria for sufficient
resolution of the arsenate peak.
Methanol is added to the mobile phase in order to enhance the signal intensity for arsenic. The
concentration of methanol to achieve the highest signal to noise ratio depends on the instrument used
and should be identified by the analyst.
Different mobile phase may be also used according to the instructions of the manufacturer of the column
but it is necessary to verify optimal separation conditions.
1 1
EXAMPLE For example, Agilent column G3154–65001 with a guard column G3154–65002 and
a recommended mobile phase for this column (dihydrogen potassium carbonate 2 mmol, EDTA 0,2 mmol, pH 6,0
adjusted with sodium hydroxide solution 1 mol) were successfully used for the analysis.
5.9 Arsenic (V) standard stock solution, with an arsenic (V) mass concentration of 1 000 mg/l.
The use of commercial standards of arsenic As (V), with a mass concentration of 1 000 mg/l is
recommended.
5.10 Arsenic (V) standard solution I, with an arsenic (V) mass concentration of 10 mg/l in 2 %
(volume fraction) HNO .
Pipette 1 ml of arsenic standard stock solution (5.9) into a 100 ml volumetric flask. Add 2 ml of nitric acid
(5.2), fill to the mark with water (5.1) and mix well. This solution is stable in a refrigerator at least one
week.
5.11 Arsenic (V) standard solution II, with an arsenic (V) mass concentration of 1 mg/l.

Agilent® is a registered trademark of Agilent Technologies Inc. This information is given for the convenience of
users of this document and does not constitute an endorsement by CEN of the product named. Equivalent products
may be used if they can be shown to lead to the same results.
oSIST prEN 18254:2025
prEN 18254:2025 (E)
Pipette 10 ml of arsenic standard solution I (5.10) into a 100 ml volumetric flask, fill to the mark with
water (5.1) and mix well. This solution should be prepared on the same day of use.
5.12 Solution for checking chromatographic separation, containing organic arsenic compounds (e.g.
10 μg/l) monomethylarsenous acid (MMA), dimethylarsinic acid (DMA) and arsenobetaine (AB), as well
as arsenate (e.g. 10 μg/l), arsenite (e.g. 10 μg/l) and chloride (e.g. 100 mg/l).
This solution is recommended to demonstrate satisfactory resolution of individual arsenic species,
possible interferents and to find out how the chromatographic conditions should be optimized (e.g. by
changing the mobile phase concentration or the mobile phase flow rate). The solution shall be prepared
in water (5.1), not in the extraction solution, to check the retention time of the individual arsenic species,
their visual presentation in the chromatogram and how the peaks are separated.
6 Apparatus
6.1 Common laboratory glass (plastic) ware.
Plastic volumetric flasks are recommended for the preparation of the mobile phase and calibration
solutions. All glassware and plastic ware shall be adequately cleaned and stored to avoid any
contamination, including arsenic contamination.
6.2 Laboratory grinder, cap
...