Coaxial cables - Part 9-1: Sectional specification for coaxial cables for analogue and digital signal transmission - Indoor drop cables for systems operating at 5 MHz - 1 000 MHz

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to coaxial indoor drop cables for analogue and digital signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with the EN 60728 series and with EN 50173 and EN 50174 series.
Cables according to this standard are designed for an operating temperature range from -40 °C and +70 °C  and at frequencies between 5 MHz and 1 000 MHz.
The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, and environmental and fire performance of the cables.

Koaxiale Kabel - Teil 9-1: Rahmenspezifikation für koaxiale Kabel für analoge und digitale Signalübertragung – Innenkabel für Systeme im Bereich von 5 MHz - 1 000 MHz

Câbles coaxiaux - Partie 9-1: Spécification intermédiaire pour câbles coaxiaux pour la transmission de signaux analogiques et numériques – Câbles de raccordement à usage intérieur pour les systèmes fonctionnant entre 5 MHz et 1 000 MHz

La présente partie de l’EN 50117 qui est une spécification intermédiaire s’applique aux câbles coaxiaux de raccordement à usage intérieur pour la transmission unidirectionnelle ou bidirectionnelle de signaux analogiques et numériques, par exemple pour les réseaux de distribution par câbles pour signaux de télévision, signaux de radiodiffusion sonore et services interactifs, conformément aux normes EN 60728-1, EN 60728-1-1, EN 60728-101, EN 60728-10, EN 50173-1 et EN 50173-4. Cela inclut également la transmission de signaux BCT (Technologies de communication et de télédiffusion) fournis par un réseau de distribution par câble (CATV, MATV ou SMATV).
La présente Norme européenne est destinée à spécifier les méthodes d’essai et les exigences applicables pour les caractéristiques électriques, mécaniques et d’environnement et pour les performances de tenue au feu des câbles.

Koaksialni kabli - 9-1. del: Področna specifikacija za koaksialne kable za analogni in digitalni prenos signala - Notranji priključni kabli za sisteme, ki delujejo v območju od 5 MHz do 1 000 MHz

Ta evropski standard je povezan s standardom EN 50117-1 in naj bi se uporabljal skupaj s to splošno specifikacijo. Ta specifikacija se uporablja za koaksialne notranje priključne kable za analogni in digitalni prenos signala, npr. za kabelska omrežja za televizijske signale, zvočne signale ter interaktivne storitve v skladu s skupino standardov EN 60728, EN 50173 in EN 50174.
Kabli v skladu s tem standardom so zasnovani za delovanje v temperaturnem območju od –40 °C do 70 °C in pri frekvencah med 5 MHz in 1000 MHz.
Namen tega evropskega standarda je določiti veljavne preskusne metode in zahteve za električne, mehanske, okoljske ter požarne lastnosti kablov.

General Information

Status
Published
Public Enquiry End Date
31-Aug-2017
Publication Date
08-May-2019
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
17-Apr-2019
Due Date
22-Jun-2019
Completion Date
09-May-2019

Relations

Buy Standard

Standard
EN 50117-9-1:2019
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2019
Nadomešča:
SIST EN 50117-2-1:2005
SIST EN 50117-2-1:2005/A1:2008
SIST EN 50117-2-1:2005/A2:2013
Koaksialni kabli - 9-1. del: Področna specifikacija za koaksialne kable za analogni
in digitalni prenos signala - Notranji priključni kabli za sisteme, ki delujejo v
območju od 5 MHz do 1 000 MHz
Coaxial cables - Part 9-1: Sectional specification for coaxial cables for analogue and
digital signal transmission - Indoor drop cables for systems operating at 5 MHz - 1 000
MHz
Koaxiale Kabel - Teil 9-1: Rahmenspezifikation für koaxiale Kabel für analoge und
digitale Signalübertragung – Innenkabel für Systeme im Bereich von 5 MHz - 1 000 MHz
Câbles coaxiaux - Partie 9-1: Spécification intermédiaire pour câbles coaxiaux pour la
transmission de signaux analogiques et numériques – Câbles de raccordement à usage
intérieur pour les systèmes fonctionnant entre 5 MHz et 1 000 MHz
Ta slovenski standard je istoveten z: EN 50117-9-1:2019
ICS:
33.120.10 Koaksialni kabli. Valovodi Coaxial cables. Waveguides
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 50117-9-1

NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2019
ICS 33.120.10 Supersedes EN 50117-2-1:2005
English Version
Coaxial cables - Part 9-1: Sectional specification for coaxial
cables for analogue and digital signal transmission - Indoor drop
cables for systems operating at 5 MHz - 1 000 MHz
Câbles coaxiaux - Partie 9-1: Spécification intermédiaire Koaxialkabel - Teil 9-1: Rahmenspezifikation für
pour câbles coaxiaux pour la transmission de signaux Koaxialkabel für analoge und digitale Signalübertragung -
analogiques et numériques - Câbles de raccordement à Innenkabel für Systeme im Bereich von 5 MHz - 1 000 MHz
usage intérieur pour les systèmes fonctionnant entre 5 MHz
et 1 000 MHz
This European Standard was approved by CENELEC on 2018-10-10. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50117-9-1:2019 E
Contents Page
European foreword .3
1 Scope .4
2 Normative references .4
3 Terms and definitions .5
4 Requirements for cable construction and design .5
4.1 General .5
4.2 Inner conductor .6
4.3 Dielectric .6
4.4 Outer conductor or screen .6
4.5 Filling compounds .6
4.6 Moisture barriers.6
4.7 Wrapping layers .6
4.8 Sheath .7
4.9 Metallic protection .7
4.10 Cable integral suspension strand (Messenger wire) .7
4.11 Oversheath .7
4.12 Fauna proofing .7
4.13 Chemical and/or environmental proofing .7
4.14 Cable identification .7
4.14.1 General .7
4.14.2 Sheath marking .7
4.15 Labelling .8
5 Tests and requirements for completed cables .8
5.1 General .8
5.2 Electrical parameters and requirements .8
5.2.1 Low-frequency and DC electrical parameters and requirements .8
5.2.2 High-frequency electrical and transmission parameters and requirements .9
5.3 Mechanical parameters and requirements . 10
5.4 Environmental parameters and requirements . 12
5.5 Fire performance test methods . 12
Annex A (informative) Cable types . 13
Bibliography . 14

European foreword
This document (EN 50117-9-1:2019) has been prepared by CLC/SC 46XA "Coaxial cables" of CLC/TC 46X
"Communication cables".
The following dates are fixed:
• latest date by which this document has (dop) 2019-09-29
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2022-03-29
standards conflicting with this document
have to be withdrawn
This document supersedes EN 50117-2-1:2005.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission and
the European Free Trade Association.
All materials used for cables according to this standard should fulfil the requirements of the current REACH
Regulation and ROHS Directives.
1 Scope
This part of EN 50117 which is a sectional specification applies to coaxial indoor drop cables for analogue and
digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and
interactive services in accordance with EN 60728-1, EN 60728-1-1, EN 60728-101, EN 60728-10, EN 50173-
1 and EN 50173-4. This includes also the transmission of BCT signals provided by a CATV, MATV or SMATV
cable network.
The purpose of this document is to specify the applicable test methods and requirements for the electrical,
mechanical and environmental characteristics and for fire performance of the cables.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 50117-1:2019, Coaxial cables - Part 1: Generic specification
EN 50173-1, Information technology - Generic cabling systems - Part 1: General requirements
EN 50173-4, Information technology - Generic cabling systems - Part 4: Homes
EN 50289-3-9:2001, Communication cables - Specifications for test methods - Part 3-9: Mechanical test
methods - Bending tests
EN 50290-1-2:2004, Communication cables - Part 1-2: Definitions
EN 50290-2-1:2005, Communication cables - Part 2-1: Common design rules and construction
EN 50290-2-22, Communication cables - Part 2-22: Common design rules and construction - PVC sheathing
compounds
EN 50290-2-27, Communication cables - Part 2-27: Common design rules and construction - Halogen free
flame retardant thermoplastic sheathing compounds
EN 50290-2-37, Communication cables - Part 2-37: Common design rules and construction - Polyethylene
insulation for coaxial cables
EN 50290-2-38, Communication cables - Part 2-38: Common design rules and construction - Polypropylene
insulation for coaxial cables
EN 50290-4-1:2014, Communication cables - Part 4-1: General considerations for the use of cables -
Environmental conditions and safety aspects
EN 50290-4-2:2014, Communication cables - Part 4-2: General considerations for the use of cables - Guide to
use
EN 60728-1, Cable networks for television signals, sound signals and interactive services - Part 1: System
performance of forward paths (IEC 60728-1)
EN 60728-1-1, Cable networks for television signals, sound signals and interactive services - Part 1-1: RF
cabling for two way home networks (IEC 60728-1-1)
EN 60728-10, Cable networks for television signals, sound signals and interactive services - Part 10: System
performance for return paths (IEC 60728-10)
EN 60728-101, Cable networks for television signals, sound signals and interactive services - Part 101:
System performance of forward paths loaded with digital channels only (IEC 60728-101)
EN 62153-1-1, Metallic communication cables test methods - Part 1-1: Electrical - Measurement of the
pulse/step return loss in the frequency domain using the Inverse Discrete Fourier Transformation (IDFT) (IEC
62153-1-1)
IEC 61196-1-112, Coaxial communication cables - Part 1-112: Electrical test methods - Test for return loss
(uniformity of impedance)
IEC 61196-1-115, Coaxial communication cables - Part 1-115: Electrical test methods - Test for regularity of
impedance (pulse/step function return loss)
IEC 62153-4-3, Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility (EMC) -
Surface transfer impedance - Triaxial method
IEC 62153-4-4, Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) -
Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 50290-1-2:2004, EN 50117-1:2019,
EN 60728-1 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
drop cable
coaxial cable which is used to connect from:
a) subscriber tap or a directional coupler to a system outlet,
b) subscriber tap to a subscriber splitter,
c) subscriber splitter to a system outlet
3.2
indoor drop cable
drop cable for indoor application
4 Requirements for cable construction and design
4.1 General
1)
Cables according to this standard are designed for an operating temperature range from -40 °C to +70 °C
and at frequencies between 5 MHz and 1 000 MHz.
When designing the cable, consideration should be given to the maximum admissible current stated in the
detail specification. It is assumed that the raise of temperature of the inner conductor when submitted to the
maximum current under nominal ambient conditions does not affect the mechanical and electrical properties
of the cable.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.