Radio frequency and coaxial cable assemblies - Part 2-3: Detail specification for flexible coaxial cable assemblies - Frequency range 0 to 1 000 MHz, IEC 61169-8 connectors (IEC 60966-2-3:2009)

IEC 60966-2-3:2009(E) is a detail specification that applies to flexible coaxial cables described in IEC 60096-2. It relates to flexible coaxial cable assemblies using BNC connectors. This detail specification gives subfamily requirements and severities which shall be applied . This third edition cancels and replaces the second edition published in 2003. It constitutes a technical revision. The major change with respect to the second edition is the reference to IEC 61169-8 instead of IEC 60169-8.   This detail specification is to be read in conjunction with IE C 60966-1:1999, IE C 60966-2-1:2008 and IE C 60966-2-2:2003.

Konfektionierte Koaxial- und Hochfrequenzkabel - Teil 2-3: Bauartspezifikation für flexible konfektionierte Koaxialkabel - Frequenzbereich 0 bis 1000 MHz, Stecker nach IEC 61169-8 (IEC 60966-2-3:2009)

Ensembles de cordons coaxiaux et de cordons pour fréquences radioélectriques - Partie 2-3: Spécification particulière pour cordons coaxiaux souples - Bande de fréquences de 0 MHz à 1 000 MHz, connecteurs CEI 61169-8 (CEI 60966-2-3:2009)

La CEI 60966-2-3:2009 est une spécification particulière qui s'applique aux câbles coaxiaux souples décrits dans la CEI 60096-2. Elle concerne les cordons coaxiaux souples munis de connecteurs BNC. La présente spécification particulière donne les exigences et les sévérités de sous-famille qui doivent être appliquées. Pour obtenir l'homologation, les opérations de qualification seront réalisées conformément au 12.2 de la CEI 60966-2-1 en tenant compte des variantes spécifiées. Seuls les essais dont les résultats pourraient dépendre des variantes seront répétés. Pour obtenir l'agrément de savoir-faire, les opérations de qualification seront réalisées sur les CQC correspondants comme cela est défini en 12.3 de la CEI 60966-2-1 et décrit dans le manuel CM. Sauf spécification contraire dans le manuel CM, seuls les essais lot par lot des groupes Ba et Eb seront réalisés sur les produits livrés, tous les autres essais seront réalisés sur les CQC comme cela est défini en 12.3 de la CEI 60966-2-1 et décrit dans le manuel CM.
Cette publication doit être lue conjointement avec la CEI 60966-1:1999.
IEC 60966-2-1:2008 et IE 60966-2-2:2003
C

Radijska frekvenca in sestavi koaksialnih kablov - 2-1. del: Podrobna specifikacija za sestave fleksibilnih (zvijavih) koaksialnih kablov - Frekvenčno območje od 0 do 1 000 MHz, konektorji po IEC 61169-8 (IEC 60966-2-3:2009)

General Information

Status
Published
Publication Date
20-Sep-2009
Technical Committee
iTEL - Communication cables
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
12-Aug-2009
Due Date
17-Oct-2009
Completion Date
21-Sep-2009

Relations

Effective Date
13-May-2010

Overview

SIST EN 60966-2-3:2009 is a European standard detailing specifications for flexible coaxial cable assemblies operating within the frequency range of 0 MHz to 1,000 MHz. This specification focuses on assemblies utilizing IEC 61169-8 connectors-specifically BNC type connectors-which feature a 50-ohm characteristic impedance and bayonet locking mechanism. Organized by the European Committee for Electrotechnical Standardization (CLC) and aligned with the International Electrotechnical Commission (IEC), this third edition supersedes the 2003 version, primarily updating the connector reference to IEC 61169-8 from IEC 60169-8. It serves as a critical reference to ensure quality, compatibility, and reliability of flexible coaxial cable assemblies in radio frequency (RF) applications.

Key Topics

  • Scope and Application:
    Specifies flexible coaxial cable assemblies described in IEC 60096-2, combined with BNC connectors per IEC 61169-8, widely used in RF signal transmission.

  • Frequency Range:
    Designed for operation from 0 MHz up to 1,000 MHz, suitable for various telecommunications, CATV, and broadcast systems.

  • Mechanical and Electrical Requirements:

    • Characteristic impedance: 50 Ω ± 2 Ω with ≤ 200 ps rise time
    • Voltage proof minimum: 1.0 kV at 50-65 Hz peak
    • Insulation resistance: >10 MΩ under standard test conditions
    • Inner and outer conductor continuity with ≤ 10 mΩ after tensile testing
    • Tensile strength minimum: 30 N for 1-minute duration
    • Flexure endurance: 500 cycles under specified forces
    • Cable assembly crushing resistance: minimum 600 N
  • Connector Specifications:
    Incorporates IEC 61169-8 standard BNC connectors, both straight and right-angled types, ensuring bayonet locking and ease of use.

  • Testing Protocols:
    Detailed test groups for conformity evaluation including visual, dimensional inspections, voltage proof, insulation resistance, conductor continuity, tensile tests, flexure, flexing endurance, and crushing tests, with defined frequency for lot-by-lot and periodic quality control.

  • Referenced Standards:
    To be read in conjunction with:

    • IEC 60966-1: Generic specifications and test methods for RF and coaxial assemblies
    • IEC 60966-2-1: Sectional specifications for flexible coaxial cable assemblies
    • IEC 60966-2-2: Blank detail specification for flexible assemblies
    • IEC 61196-6: Sectional specifications for CATV drop cables

Applications

SIST EN 60966-2-3:2009 is essential for manufacturers, testers, and system integrators involved in producing or employing flexible coaxial cable assemblies with BNC connectors within vital RF and telecommunications infrastructure. Common applications include:

  • Cable assemblies for CATV distribution and drop cables
  • Broadcast and professional audio/video interconnections
  • RF measurement and test equipment
  • Telecommunications and data communication patch cables
  • Laboratory and industrial RF signal transmission

By adhering to this standard, users ensure interchangeability, performance reliability, durability under mechanical stress, and compliance with international quality benchmarks critical for high-frequency signals in coaxial systems.

Related Standards

For a comprehensive understanding and implementation, SIST EN 60966-2-3:2009 should be used alongside the following standards:

  • EN 60966-1:1999 – Generic specification providing general requirements and test methods for RF and coaxial assemblies.
  • EN 60966-2-1:2009 – Sectional specification detailing flexible coaxial cable assemblies.
  • EN 60966-2-2:2003 – Blank detail specification for flexible coaxial cable assemblies supporting customization.
  • EN 61169-8:2007 – Specification for BNC RF coaxial connectors with 6.5 mm outer conductor inner diameter and bayonet coupling.
  • IEC 61196-6 – Standard covering CATV drop cables, relevant for assemblies built with compliant coaxial cables.

Benefits and Practical Value

Implementing SIST EN 60966-2-3:2009 in manufacturing and testing processes enhances system reliability by guaranteeing that flexible coaxial cable assemblies meet stringent electrical and mechanical performance requirements. The standard supports:

  • Consistent impedance matching to minimize signal reflections and losses
  • Mechanical endurance for demanding installation environments
  • Compatibility with standardized BNC connectors ensuring seamless integration
  • Streamlined quality assurance through defined testing regimes
  • Enhanced lifecycle performance reducing maintenance and downtime

By conforming to this specification, stakeholders benefit from improved product interoperability, reduced risk of signal degradation, and adherence to international norms fostering easier market access and regulatory compliance.

Standard

SIST EN 60966-2-3:2009 - BARVE

English language
9 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 60966-2-3:2009 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Radio frequency and coaxial cable assemblies - Part 2-3: Detail specification for flexible coaxial cable assemblies - Frequency range 0 to 1 000 MHz, IEC 61169-8 connectors (IEC 60966-2-3:2009)". This standard covers: IEC 60966-2-3:2009(E) is a detail specification that applies to flexible coaxial cables described in IEC 60096-2. It relates to flexible coaxial cable assemblies using BNC connectors. This detail specification gives subfamily requirements and severities which shall be applied . This third edition cancels and replaces the second edition published in 2003. It constitutes a technical revision. The major change with respect to the second edition is the reference to IEC 61169-8 instead of IEC 60169-8. This detail specification is to be read in conjunction with <a href='http://webstore.iec.ch/webstore/webstore.nsf/artnum/024991'>IE C 60966-1:1999</a>, <a href='http://webstore.iec.ch/webstore/webstore.nsf/artnum/041971'>IE C 60966-2-1:2008</a> and <a href='http://webstore.iec.ch/webstore/webstore.nsf/artnum/030979'>IE C 60966-2-2:2003</a>.

IEC 60966-2-3:2009(E) is a detail specification that applies to flexible coaxial cables described in IEC 60096-2. It relates to flexible coaxial cable assemblies using BNC connectors. This detail specification gives subfamily requirements and severities which shall be applied . This third edition cancels and replaces the second edition published in 2003. It constitutes a technical revision. The major change with respect to the second edition is the reference to IEC 61169-8 instead of IEC 60169-8. This detail specification is to be read in conjunction with <a href='http://webstore.iec.ch/webstore/webstore.nsf/artnum/024991'>IE C 60966-1:1999</a>, <a href='http://webstore.iec.ch/webstore/webstore.nsf/artnum/041971'>IE C 60966-2-1:2008</a> and <a href='http://webstore.iec.ch/webstore/webstore.nsf/artnum/030979'>IE C 60966-2-2:2003</a>.

SIST EN 60966-2-3:2009 is classified under the following ICS (International Classification for Standards) categories: 33.120.10 - Coaxial cables. Waveguides. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 60966-2-3:2009 has the following relationships with other standards: It is inter standard links to SIST EN 60966-2-3:2004. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 60966-2-3:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2009
1DGRPHãþD
SIST EN 60966-2-3:2004
5DGLMVNDIUHNYHQFDLQVHVWDYLNRDNVLDOQLKNDEORYGHO3RGUREQDVSHFLILNDFLMD
]DVHVWDYHIOHNVLELOQLK ]YLMDYLK NRDNVLDOQLKNDEORY)UHNYHQþQRREPRþMHRGGR
0+]NRQHNWRUMLSR,(& ,(&
Radio frequency and coaxial cable assemblies - Part 2-3: Detail specification for flexible
coaxial cable assemblies - Frequency range 0 to 1 000 MHz, IEC 61169-8 connectors
(IEC 60966-2-3:2009)
Konfektionierte Koaxial- und Hochfrequenzkabel - Teil 2-3: Bauartspezifikation für
flexible konfektionierte Koaxialkabel - Frequenzbereich 0 bis 1000 MHz, Stecker nach
IEC 61169-8 (IEC 60966-2-3:2009)
Ensembles de cordons coaxiaux et de cordons pour fréquences radioélectriques - Partie
2-3: Spécification particulière pour cordons coaxiaux souples - Bande de fréquences de
0 MHz à 1 000 MHz, connecteurs CEI 61169-8 (CEI 60966-2-3:2009)
Ta slovenski standard je istoveten z: EN 60966-2-3:2009
ICS:
33.120.10 Koaksialni kabli. Valovodi Coaxial cables. Waveguides
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 60966-2-3
NORME EUROPÉENNE
August 2009
EUROPÄISCHE NORM
ICS 33.120.10 Supersedes EN 60966-2-3:2003

English version
Radio frequency and coaxial cable assemblies -
Part 2-3: Detail specification for flexible coaxial cable assemblies -
Frequency range 0 MHz to 1 000 MHz, IEC 61169-8 connectors
(IEC 60966-2-3:2009)
Ensembles de cordons coaxiaux Konfektionierte Koaxial- und
et de cordons pour Hochfrequenzkabel -
fréquences radioélectriques - Teil 2-3: Bauartspezifikation
Partie 2-3: Spécification particulière für flexible konfektionierte Koaxialkabel -
pour cordons coaxiaux souples - Frequenzbereich 0 MHz bis 1000 MHz,
Bande de fréquences Steckverbinder nach IEC 61169-8
de 0 MHz à 1 000 MHz, (IEC 60966-2-3:2009)
connecteurs CEI 61169-8
(CEI 60966-2-3:2009)
This European Standard was approved by CENELEC on 2009-07-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: Avenue Marnix 17, B - 1000 Brussels

© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60966-2-3:2009 E
Foreword
The text of document 46/302/FDIS, future edition 3 of IEC 60966-2-3, prepared by IEC TC 46, Cables,
wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories, was
submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60966-2-3 on
2009-07-01.
This European Standard supersedes EN 60966-2-3:2003.
The major change with respect to EN 60966-2-3:2003 is the reference to EN 61169-8 instead of
EN 60169-8.
This detail specification is to be read in conjunction with EN 60966-1:1999, with EN 60966-2-1:2009, and
with EN 60966-2-2:2003.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2010-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2012-07-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60966-2-3:2009 was approved by CENELEC as a European
Standard without any modification.
__________
- 3 - EN 60966-2-3:2009
Annex ZA
(normative)
Reference documents with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

IEC 60966-1 1999 Radio frequency and coaxial cable EN 60966-1 1999
assemblies -
Part 1: Generic specification - General
requirements and test methods
IEC 60966-2-1 2008 Radio frequency and coaxial cable EN 60966-2-1 2009
assemblies -
Part 2-1: Sectional specification for flexible
coaxial cable assemblies
IEC 60966-2-2 2003 Radio frequency and coaxial cable EN 60966-2-2 2003
assemblies -
Part 2-2: Blank detail specification for flexible
coaxial cable assemblies
1) 2)
IEC 61169-8 - Radio-frequency connectors - EN 61169-8 2007
Part 8: Sectional specification - RF coaxial
connectors with inner diameter of outer
conductor 6,5 mm (0,256 in) with bayonet
lock - Characteristics impedance 50 ohms
(type BNC)
1)
IEC 61196-6 - Coaxial communication cables - - -
Part 6: Sectional specification for CATV drop
cables
1)
Undated reference.
2)
Valid edition at date of issue.

IEC 60966-2-3
Edition 3.0 2009-01
INTERNATIONAL
STANDARD
Radio frequency and coaxial cable assemblies –
Part 2-3: Detail specification for flexible coaxial cable assemblies – Frequency
range 0 MHz to 1 000 MHz, IEC 61169-8 connectors

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
F
ICS 33.120.10 ISBN 2-8318-1022-1
– 2 – 60966-2-3 © IEC:2009(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES –

Part 2-3: Detail specification for flexible coaxial cable assemblies –
Frequency range 0 MHz to 1 000 MHz, IEC 61169-8 connectors

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
a
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.