SIST EN 60155:1999/A1:1999
(Amendment)Glow-starters for fluorescent lamps (IEC 60155:1993/A1:1995)
Glow-starters for fluorescent lamps (IEC 60155:1993/A1:1995)
EN following parallel vote
Glimmstarter für Leuchtstofflampen (IEC 60155:1993/A1:1995)
Interrupteurs d'amorçage à lueur pour lampes à fluorescence (starters) (CEI 60155:1993/A1:1995)
Tlivni starterji za fluorescenčne sijalke - Dopolnilo A1 (IEC 60155:1993/A1:1995)
General Information
- Status
- Published
- Publication Date
- 30-Jun-1999
- Technical Committee
- IESV - Lamps and related equipment
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Jul-1999
- Due Date
- 01-Jul-1999
- Completion Date
- 01-Jul-1999
Relations
- Effective Date
- 01-Jul-1999
Overview
EN 60155:1995/A1:1995 (Glow‑starters for fluorescent lamps) is the European adoption of IEC 60155:1993 amended in 1995. The amendment updates test methods, adds information relevant to luminaire design, and tightens safety requirements for components used in glow‑starters (starters) for fluorescent and discharge lamps. This standard is intended for manufacturers, test laboratories, luminaire designers and procurement/specification teams concerned with reliable lamp starting and safety.
Key Topics and Requirements
- Scope and identity
- Harmonises with IEC 60155:1993/A1:1995 for glow‑starters used with fluorescent lamps and related discharge lamp applications.
- New informational clause
- Addition of Clause 11 / Annex C: information for luminaire design, including the requirement that the maximum temperature of any part of the starter canister shall not exceed 80 °C.
- Component safety - capacitors
- Capacitors used in starter circuits must be resistant to flame and ignition. The amended test procedure:
- Gradual AC voltage increase until breakdown using a source with about 1 kVA short‑circuit power.
- After breakdown, the capacitor is wrapped with tissue paper per ISO 4046 (Paper - vocabulary) and operated in series with a 40 W inductive ballast at rated voltage for 5 minutes; the capacitor must not ignite the tissue.
- Capacitors used in starter circuits must be resistant to flame and ignition. The amended test procedure:
- Operational performance
- Speed of operation: Test voltage (per IEC 81/901 lamp starting tests) is applied for 25 s; during this period the starter contacts shall open at least seven times (except specified 20 W lamp condition).
- Closed time: During the 25 s test the contacts shall be closed for a minimum total of 10 s.
- Pulse voltage and measurement
- The same test voltage used for speed/starting is applied for 25 s during pulse voltage testing.
- The amendment permits a memory oscilloscope with a specified high‑voltage probe as an alternative to an electrostatic voltmeter (but the electrostatic voltmeter remains the reference in disputes).
- Test circuit details
- Revised Figure 9 defines a high‑voltage test circuit, giving component recommendations (e.g., HV diode types such as BYX90G, HV capacitor values and rated voltages, and electrostatic voltmeter characteristics).
Applications and Users
- Manufacturers of glow‑starters and starter components - to ensure compliance with safety and performance tests.
- Luminaire and lighting designers - to size compartments and verify that starter canister temperatures and mounting meet the 80 °C limit.
- Test laboratories and conformity assessment bodies - for performing the specified flame, endurance and pulse‑voltage tests.
- Procurement/specification authors - to reference the standard in product specifications and safety data sheets.
Related Standards
- IEC 60155:1993 (base standard)
- ISO 4046:1978 (referenced for tissue paper used in flame/ignition tests)
- IEC 81 and IEC 901 (lamp starting test voltages referenced)
Keywords: glow‑starters, fluorescent lamps, EN 60155, IEC 60155, starter tests, luminaire design, capacitor flame resistance, pulse voltage test.
Frequently Asked Questions
SIST EN 60155:1999/A1:1999 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Glow-starters for fluorescent lamps (IEC 60155:1993/A1:1995)". This standard covers: EN following parallel vote
EN following parallel vote
SIST EN 60155:1999/A1:1999 is classified under the following ICS (International Classification for Standards) categories: 29.140.30 - Fluorescent lamps. Discharge lamps. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 60155:1999/A1:1999 has the following relationships with other standards: It is inter standard links to SIST EN 60155:1999. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 60155:1999/A1:1999 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 60155:1999/A1:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-1999
7OLYQLVWDUWHUML]DIOXRUHVFHQþQHVLMDONH'RSROQLOR$,(&$
Glow-starters for fluorescent lamps (IEC 60155:1993/A1:1995)
Glimmstarter für Leuchtstofflampen (IEC 60155:1993/A1:1995)
Interrupteurs d'amorçage à lueur pour lampes à fluorescence (starters) (CEI
60155:1993/A1:1995)
Ta slovenski standard je istoveten z: EN 60155:1995/A1:1995
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
INTERNATIONAL IEC
STANDARD 60155
AMENDMENT 1
1995-10
Amendment 1
Glow-starters for fluorescent lamps
This English-language version is derived from the original
bilingual publication by leaving out all French-language
pages. Missing page numbers correspond to the French-
language pages.
IEC 1995 Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical,
including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
D
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
Oo
IEC:1 995 155 Amend. 1 - 3 -
FOREWORD
This amendment has been prepared by sub-committee 34A: Lamps, of IEC technical com-
mittee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:
DIS
Report on voting
34A/623/RVD
34A/586/DIS
Full information on the voting for the approval of this amendment can be found in the
report on voting indicated in the above table.
Page 3
Contents
Add the title of the new clause 11 and the new annex C as follows:
11 Information for luminaire design
Annex C - Information for luminaire design
Page 9
2 Normative references
Add the following normative reference:
ISO 4046: 1978, Paper, board, pulp and related items - Vocabulary
Page 19
Subclause 7.12.3
Delete the text of this subclause and replace it by the following:
7.12.3 The capacitor shall be resistant to flame and ignition.
Compliance shall be checked by the following test. The capacitors are each subjected to a
gradually increasing a.c. voltage until breakdown occurs. The voltage source used to this
effect should have a short-circuit power of approximately 1 kVA.
Thereafter, each capacitor shall be completely wrapped with tissue paper as specified in 6.86
of ISO 4046 and shall be connected in series with a 40 W inductive ballast complying with
the requirements of annex A and operated for 5 min at the rated voltage of the ballast.
During this test, the capacitor shall not inflame the tissue paper.
155 Amend. 1 ©IEC:1 995 - 5 -
Page 23
8.4 Speed of operation
Delete the existing text and replace it by the following new text:
With the exception of 20 W lamps as specified in IEC 81 for which the voltage shall be
103,5 V, a voltage equal to the test voltage of the lamp starting test for the relevant lamp
specified in IEC 81 or in IEC 901 shall be app
...