Industrial communication networks - Profiles - Part 5-x: Installation of fieldbuses - Installation profiles for CPF x (x=2, 3, 6, 12, 21)

Réseaux de communication industriels - Profils - Partie 5-x: Installation des bus de terrain - Profils d’installation pour CPF x (x = 2, 3, 6, 12, 21)

Industrijska komunikacijska omrežja - Profili - 5-x. del: Inštalacija procesnih vodil - Inštalacijski profili za CPF x (x = 2, 3, 6, 12, 21)

General Information

Status
Not Published
Public Enquiry End Date
12-Jun-2022
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
05-Apr-2022
Due Date
23-Aug-2022
Completion Date
13-Jun-2022

Relations

Buy Standard

Draft
prEN IEC 61784-5-X:2022 - BARVE
English language
92 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN IEC 61784-5-X:2022
01-junij-2022
Industrijska komunikacijska omrežja - Profili - 5-x. del: Inštalacija procesnih vodil -
Inštalacijski profili za CPF x (x = 2, 3, 6, 12, 21)
Industrial communication networks - Profiles - Part 5-x: Installation of fieldbuses -
Installation profiles for CPF x (x=2, 3, 6, 12, 21)
Réseaux de communication industriels - Profils - Partie 5-x: Installation des bus de
terrain - Profils d’installation pour CPF x (x = 2, 3, 6, 12, 21)
Ta slovenski standard je istoveten z: prEN IEC 61784-5-X:2022
ICS:
25.040.40 Merjenje in krmiljenje Industrial process
industrijskih postopkov measurement and control
35.100.40 Transportni sloj Transport layer
oSIST prEN IEC 61784-5-X:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN IEC 61784-5-X:2022

---------------------- Page: 2 ----------------------
oSIST prEN IEC 61784-5-X:2022
65C/1158/CDV

COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 61784-5-X ED5
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2022-03-25 2022-06-17
SUPERSEDES DOCUMENTS:
65C/1111/RR

IEC SC 65C : INDUSTRIAL NETWORKS
SECRETARIAT: SECRETARY:
France Ms Valérie DEMASSIEUX
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

SC 22G,TC 57,SC 121A
Other TC/SCs are requested to indicate their interest, if any,
in this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft for
Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.

This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which they
are aware and to provide supporting documentation.

TITLE:
Industrial communication networks – Profiles – Part 5-x: Installation of fieldbuses – Installation profiles
for CPF x (x=2, 3, 6, 12, 21)

PROPOSED STABILITY DATE: 2028

NOTE FROM TC/SC OFFICERS:


Copyright © 2022 International Electrotechnical Commission, IEC. All rights reserved. It is permitted to download this
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.

---------------------- Page: 3 ----------------------
oSIST prEN IEC 61784-5-X:2022

INCLUDED SUBPARTS
NOTE 1: The page numbers of each subpart are prefixed with the CPF number of the subpart to facilitate
identification, and so that the numbering of each subpart can be independent of those that precede it.

NOTE 2: The Contents of each subpart begins on page xxx2, so that the page numbering will be unchanged when
the final International Standard is issued with its IEC-Central-Office-provided cover sheet.

NOTE 3: Part 5-8 (Ed 3.0), Part 5-19 (Ed 2.0) and Part 5-22 (Ed 1.0) are not included since they are circulated
separately (Part 5-8 and Part 5-19 have substantial changes, Part 5-22 is a new part).

NOTE 4: Part 5-1 (Ed 1.0), Part 5-4 (Ed 1.1), Part 5-10 (Ed 2.1), Part 5-11 (Ed 3.0), Part 5-13 (Ed 1.0), Part 5-14
(Ed 2.0), Part 5-15 (Ed 1.1), Part 5-16 (Ed 1.0), Part 5-17 (Ed 1.0), Part 5-18 (Ed 1.0) and Part 5-20
(Ed 1.0) are not included since they are simply reconfirmed, as indicated in 65C/1090/Q, 65C/1097/RQ
and 65C/1111/RR.


IEC 61784-5-2 Ed4.0, Amendment 1, Industrial communication networks - Profiles –
Part 5-2: Installation of fieldbuses – Installation profiles for CPF 2 . 2002

IEC 61784-5-3 Ed4.0, Amendment 1, Industrial communication networks - Profiles –
Part 5-3: Installation of fieldbuses – Installation profiles for CPF 3 . 3002

IEC 61784-5-6 Ed5.0, Industrial communication networks - Profiles –
Part 5-6: Installation of fieldbuses – Installation profiles for CPF 6 . 6002

IEC 61784-5-12 Ed3.0, Industrial communication networks - Profiles –
Part 5-12: Installation of fieldbuses – Installation profiles for CPF 12 . 12002

IEC 61784-5-21 Ed1.0, Amendment 1, Industrial communication networks - Profiles –
Part 5-21: Installation of fieldbuses – Installation profiles for CPF 21 . 21002

---------------------- Page: 4 ----------------------
oSIST prEN IEC 61784-5-X:2022
– 2002 – IEC CDV 61784-5-2:2018/AMD1
© IEC 2022
1 INTERNATIONAL ELECTROTECHNICAL COMMISSION
2 ____________
3
4 INDUSTRIAL COMMUNICATION NETWORKS –
5 PROFILES –
6
7 Part 5-2: Installation of fieldbuses –
8 Installation profiles for CPF 2
9
10 AMENDMENT 1
11
12 FOREWORD
13 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
14 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
15 international co-operation on all questions concerning standardization in the electrical and electronic fields. To
16 this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
17 Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
18 Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
19 in the subject dealt with may participate in this preparatory work. International, governmental and non-
20 governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
21 with the International Organization for Standardization (ISO) in accordance with conditions determined by
22 agreement between the two organizations.
23 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
24 consensus of opinion on the relevant subjects since each technical committee has representation from all
25 interested IEC National Committees.
26 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
27 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
28 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
29 misinterpretation by any end user.
30 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
31 transparently to the maximum extent possible in their national and regional publications. Any divergence
32 between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
33 the latter.
34 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
35 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
36 services carried out by independent certification bodies.
37 6) All users should ensure that they have the latest edition of this publication.
38 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
39 members of its technical committees and IEC National Committees for any personal injury, property damage or
40 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
41 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
42 Publications.
43 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
44 indispensable for the correct application of this publication.
45 9) Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
46 rights. IEC shall not be held responsible for identifying any or all such patent rights.
47 Amendment 1 to IEC 61784-5-2:2018 has been prepared by subcommittee 65C: Industrial
48 networks, of IEC technical committee 65: Industrial-process measurement, control and
49 automation.
50 The text of this Amendment is based on the following documents:
Draft Report on voting
65C/XX/XXXX 65C/XX/XXX
51
52 Full information on the voting for its approval can be found in the report on voting indicated in
53 the above table.

---------------------- Page: 5 ----------------------
oSIST prEN IEC 61784-5-X:2022
IEC CDV 61784-5-2:2018/AMD1
© IEC 2022 – 2003 –
54 The language used for the development of this Amendment is English.
55 This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
56 accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement,
57 available at www.iec.ch/members_experts/refdocs. The main document types developed by
58 IEC are described in greater detail at www.iec.ch/standardsdev/publications/.
59 A list of all parts of IEC 61784-5 series, under the general title Industrial communications
60 networks – Profiles – Installation of fieldbuses, can be found on the IEC website.
61 The committee has decided that the contents of this document will remain unchanged until the
62 stability date indicated on the IEC website under webstore.iec.ch in the data related to the
63 specific document. At this date, the document will be
64 • reconfirmed,
65 • withdrawn,
66 • replaced by a revised edition, or
67 • amended.
68
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates that it
contains colours which are considered to be useful for the correct understanding of its
contents. Users should therefore print this document using a colour printer.
69
70 ___________
71
72 INTRODUCTION to Amendment 1
73 This Amendment 1 includes the following significant technical changes with respect to
74 IEC 61784-5-2:2018:
75 a) Update references of IEC 61918:2018 to include additions of IEC 61918:2018/AMD1:—
76 b) Add references for consideration of security to clause B.4.2.2
77 c) Update optical fiber specifications and references in clauses B.4.3.3.2 and B.4.4.1.4
78 d) Add definition of electromagnetic compatibility options for conformance to clause
79 B.4.4.1.2.1
80 e) Add support of mesh bonding systems to clauses B.4.4 and B.5
81 f) Add acceptance of end-to-end link verification and certification testing to clause B.6
82
83
84

---------------------- Page: 6 ----------------------
oSIST prEN IEC 61784-5-X:2022
– 2004 – IEC CDV 61784-5-2:2018/AMD1
© IEC 2022
85 FOREWORD
86 Replace “This document is to be used in conjunction with IEC 61918:2018” with “This
87 document is to be used in conjunction with IEC 61918:2018 and IEC 61918:2018/AMD1:—”.
88 INTRODUCTION
89 Replace, at the beginning of the second paragraph, “IEC 61918:2018” with “IEC 61918:2018
90 and IEC 61918:2018/AMD1:—”.
91 Replace Figure 1 with the following updated Figure.
93 Figure 1 – Standards relationships
94 1 Scope
95 Replace, in the second paragraph, “IEC 61918:2018” with “IEC 61918:2018 and IEC
96 61918:2018/AMD1:—”.
97 2 Normative references
98 Add the following normative reference:
99 IEC 61918:2018/AMD1:—, Amendment 1 – Industrial communication networks – Installation of
1
100 communication networks in industrial premises
___________
1
Under preparation. Stage at the time of publication: IEC/FDIS 61918:2018/AMD1

---------------------- Page: 7 ----------------------
oSIST prEN IEC 61784-5-X:2022
IEC CDV 61784-5-2:2018/AMD1
© IEC 2022 – 2005 –
101 Replace, in the last sentence, “IEC 61918:2018 Clause 2” with “IEC 61918:2018 Clause 2 and
102 IEC 61918:2018/AMD1:— Clause 2”
103 3 Terms, definitions, and abbreviated terms
104 Replace, in the first sentence, “IEC 61918:2018 Clause 3” with “IEC 61918:2018, Clause 3
105 and IEC 61918:2018/AMD1:—, Clause 3, and the Annexes, Clause 3”
106 6 Conformance to installation profiles
107 Replace the two items in the list following the second paragraph with the following items:
2
108 “Compliance with IEC 61784-5-2:2018 and IEC 61784-5-2:2018/AMD1:— for CP 2/m
109 or”
110 “Compliance with IEC 61784-5-2 (Ed.4.1:—) for CP 2/m ”.
111 B.2 Normative references
112 Replace “ANSI/TIA-568-C.1” with “ANSI/TIA-568.2-D” (no change to title).
113 B.4.2.2 Security
114 Replace the last paragraph with the following new paragraph:
115 CP 2/2 has provisions for supporting secure system designs aligned with IEC 62443.
116 IEC 62443 breaks down the design of security within a system to security levels based on risk
117 level. For each level there are different measures such as identification and authentication,
118 data access control, tamper detection, data access restriction, data confidentiality, response
119 time, and resource availability. Aspects of the system may need mitigations depending on the
120 level of security risk identified.
121 NOTE See [45] for more information on securing the installation of CP 2/2 systems. See ANSI/TIA 5017 [46] for
122 more information for deterrence or restricted access measures that may be taken for securing the physical
123 infrastructure of zones where it is deemed necessary or appropriate.
124 B.4.3.1.4 Combination of basic topologies
125 Replace “Not applicable” with the following new text and figure:
126 Replacement:
127 Through IEEE 802.1 bridging, CP 2/2 provides for routing of data through active topologies
128 and allows interfacing of all equipment through a hierarchical star topology. This is typically
129 facilitated through a network zone approach where an individual node on a network can be
130 replaced with an entire subnetwork configured in an independent topology such as a ring,
131 active linear bus, redundant active linear bus, or an additional active star. This concept is
132 shown in Figure B.18.
___________
2
The date should not be used when the edition number is used.

---------------------- Page: 8 ----------------------
oSIST prEN IEC 61784-5-X:2022
– 2006 – IEC CDV 61784-5-2:2018/AMD1
© IEC 2022
Redundant
Linear
Linear
Star
Ring
Node
133
134 Figure B.18 – Example of combination of basic active topologies
135
136 B.4.3.3.2 Network characteristics for optical fibre cabling
137 Replace, in the first row of Table B.2, “Bandwidth (MHz)” with “Bandwidth (Mbit/s)”
138 Replace, in the second column of Table B.2, all occurrences of “Modal bandwidth (MHz x km)”
139 with “Bandwidth (Mbit/s)”
140 Replace, in the third column of Table B.2, all occurrences of “MHz” with “Mbit/s”
141 Replace Table B.5 with the following new table:
142 Table B.5 – Recognized fibre types
Fibre Type Supported Designations Bandwidth @ Standard
fibres 850 nm/1 310 nm
Multimode 62,5 µm/125 µm OM1 200 MHz × km/500 MHz × km IEC 60793-2-10, type A1-
OM1
62,5 µm/ OM1 200 MHz × km/500 MHz × km IEC 60793-2-30, type A3g
200 µm/230 µm
50 µm/125 µm OM2 500 MHz × km/500 MHz × km IEC 60793-2-10, type A1-
OM2
2 000 MHz × km/ IEC 60793-2-10, type A1-
OM3
500 MHz × km OM3
OM4 4 700 MHz × km/ IEC 60793-2-10, type A1-
500 MHz × km OM4
OM5 4 700 MHz × km/ IEC 60793-2-10, type A1-
500 MHz × km OM5
50 µm/200 µm/ OM2 400 MHz × km/ IEC 60793-2-30, type A3f
230 µm 400 MHz × km
Single-mode 9 µm/125 µm OS1 N/A IEC 60793-2-50, type B-
652.B
OS2 N/A IEC 60793-2-50, type B-
652.D
Setp Index 980 µm/1 000 µm N/A 4 MHz × km IEC 60793-2-40, type A4a.2
Multimode and A4d
143
144 Add, in all cells of the second column of Table B.6, “,OM5” at the end of the list of supported
145 fibre types.

---------------------- Page: 9 ----------------------
oSIST prEN IEC 61784-5-X:2022
IEC CDV 61784-5-2:2018/AMD1
© IEC 2022 – 2007 –
146 Replace, in the last row of Table B.6, “1000BASE-LX10” with “1000BASE-LX10 and
147 100BASE-LX10”
148 B.4.4.1.2.1 Balanced cables for Ethernet-based CPs
149 Replace, in Table B.8, all occurrences of “ANSI/TIA 568-C.2” with “ANSI/TIA 568.2-D”.
150 Replace, in Table B.8, in row “Conductor gauges”, the contents of the right cell with “0,40 mm
151 to 0,65 mm (26AWG to 22AWG)”
152 Delete, in Table B.8, rows for “Coupling Attenuation”, “Shielding Effectiveness”, “TCL”, and
153 “ELTCTL”.
154 Add, after Table B.9, the following text:
155 Where category 6 or 6a cables are used, the extended requirements of ANSI/TIA 568.2-D
156 apply in addition to the requirements listed in this subclause B.4.4.1.2.1.
157 Replace all text and tables at the end of the subclause beginning at “Modification:” with the
158 following new text and tables:
159 Addition:
160 Cables shall be selected based on ability to support one of the four options of channel and
161 link electromagnetic performance as defined below.
162 a) The UTP cable supporting 10BASE-T or 100BASE-T applications shall be selected and
163 installed based on the ability to meet the Transverse Conversion Loss (TCL) and Equal
164 Level Transverse Conversion Transfer Loss (ELTCTL) requirements at both ends of the
165 cabling in accordance with Table B.27 and the environment local to the cabling.
166 Table B.27 – Unbalance attentuation limits for unshielded twisted-pair cabling serving
167 10BASE-T and 100BASE-T applications
Parameter Frequency Limit
a
MHz dB
TCL 1 ≤ f < 100 Compliant with ISO/IEC 11801
ELTCTL 1 ≤ f < 30 Compliant with ISO/IEC 11801
a
Limits are applicable to all environmental classifications aligned with delineation in ISO/IEC 11801-1
168
169 b) The UTP cable supporting 1000BASE-T applications shall be selected and installed based
170 on the ability to meet the Transverse Conversion Loss (TCL) and Equal Level Transverse
171 Conversion Transfer Loss (ELTCTL) requirements at both ends of the cabling in
172 accordance with Table B.28 and the environment local to the cabling.
173 Table B.28 – Unbalance attenuation limits for unshielded twisted-pair cabling serving
174 1000BASE-T applications
Parameter Frequency Limit
MHz dB
E1 E2 E3
TCL Compliant with
1 ≤ f < 30 69,2 – 15 × log (f) 79,2 – 15 × log (f)
10 10
ISO/IEC 11801
1 ≤ f ≤ 100 76,6 – 20 × log (f) 86,6 – 20 × log (f)
10 10
(max. 40 dB) (max. 46 dB)

---------------------- Page: 10 ----------------------
oSIST prEN IEC 61784-5-X:2022
– 2008 – IEC CDV 61784-5-2:2018/AMD1
© IEC 2022
Parameter Frequency Limit
MHz dB
E1 E2 E3
ELTCTL Compliant with
1 ≤ f < 30 42 – 20 × log (f) 52 – 20 × log (f)
10 10
ISO/IEC 11801
(max. 40 dB) (max. 40 dB)
175
176 c) The UTP cable supporting 1000BASE-T applications shall be selected and installed based
177 on the ability to meet the Transverse Conversion Loss (TCL) and Equal Level Transverse
178 Conversion Transfer Loss (ELTCTL) requirements at both ends of the cabling while also
179 restricting the insertion loss and indirectly the associated cable length in accordance with
180 Table B.29 and the environment local to the cabling. Under this condition the nominal
181 maximum cable length is limited to 72 m instead of the expected 100 m.
182 Table B.29 – Unbalance attenuation limits for unshielded twisted-pair cabling serving
183 1000BASE-T applications
Parameter Frequency Limit
a
MHz dB
Insertion Loss
1 ≤ f ≤100
0,72×�1,967�𝑓𝑓+0,023×𝑓𝑓+0,1/�𝑓𝑓�
TCL 1 ≤ f ≤100 Compliant with ISO/IEC 11801
ELTCTL 1 ≤ f ≤30 Compliant with ISO/IEC 11801
a
Limits are applicable to all environmental classifications aligned with delineation in ISO/IEC 11801-1
184
185 d) The shielded cable shall be selected and installed based on the ability to meet the
186 coupling attenuation requirements at both ends of the cabling in accordance with
187 Table B.30 and the environment local to the cabling. Coupling attenuation (see
188 Table B.30) shall be measured in accordance with IEC 61156-5.
189 Table B.30 – Coupling attenuation limits for screened twisted-pair cabling
Parameter Frequency Limit
a
MHz dB
Coupling 30 ≤ f ≤100 Compliant with ISO/IEC 11801
Attenuation
a
Limits are applicable to all environmental classifications aligned with delineation in ISO/IEC 11801-1
190
191 B.4.4.1.4 Optical fibre cables
192 Replace Table B.15 with the following new table:
193 Table B.15 – Information relevant to optical fibre cables
Characteristic 9.10/125 µm 50/125 µm 62,5/125 µm 980/1 000 µm 200/230 µm
single mode multimode multimode step index step index
silica silica silica POF hard clad
silica
Standard OS1 or OS2 OM2, OM3, OM1 -- --
OM4, OM5
Maximum attenuation per km – – – 18 dB 12 dB
(650 nm)
Maximum attenuation per km – 2,5 dB 3,0 dB – –
(820 nm)
Maximum attenuation per km 0,4 dB 0,8 dB 1,0 dB – –
(1 310 nm)

---------------------- Page: 11 ----------------------
oSIST prEN IEC 61784-5-X:2022
IEC CDV 61784-5-2:2018/AMD1
© IEC 2022 – 2009 –
Characteristic 9.10/125 µm 50/125 µm 62,5/125 µm 980/1 000 µm 200/230 µm
single mode multimode multimode step index step index
silica silica silica POF hard clad
silica
Number of optical fibres 2 minimum 2 minimum 2 minimum – –
Connector type (e.g. duplex or Duplex, Duplex, Duplex, – –
simplex) duplex-able, duplex-able, duplex-able,
simplex simplex simplex
Jacket colour requirements User defined User User – –
defined defined
Jacket material User defined User User – –
defined defined
Resistance to harsh As needed to As needed As needed – –
environment (e.g. UV, oil support to support to support
resist, LS0H) application application application
and and and
environment environment environment
194
195 B.4.4.2.2 Connecting hardware for balanced cabling CPs based on Ethernet
196 Replace Table B.17 with the following new table (title and contents):
197 Table B.17 – Unbalance Attenuation limits for connectors based on Ethernet serving
198 1000BASE-T applications
Parameter Frequency Limit
MHz dB
E1 E2 E3
TCL 1 ≤ f < 250 Not defined Not defined 94 – 20 × log (f)
10
TCTL Not defined Not defined
1 ≤ f < 30 71.5 – 20 × log (f)
10
199
200 Delete, in Tables B.18 and B.19, rows for “Contact rating”.
201 Replace, in Table B.19 and in Table B.20, in row “Contact plating”, the contents of the second
202 and third cells with the following text:
203 0,762 µm gold over 1,27 µm nickel or 0,127 µm gold minimum over 0,508 µm
204 palladium nickel over 1,27 µm nickel or equivalent plating.
205 Gold shall be 24 karat minimum.
206 B.4.4.2.5 Connecting hardware for optical fibre cabling
207 Replace, in Table B.22, in the column “200/230 μm step index hard cladded silica”, in the cells
208 corresponding to rows “SC”, “ST”, and “SC-RJ”, “No” with “Yes”.
209 B.4.4.7.4.1 Non-earthing or parallel RC
210 Delete “Not applicable.”.
211 B.4.4.7.4.2 Direct
212 Delete “Not applicable.”.
213 B.4.4.7.4.3 Derivatives of direct and parallel RC
214 Replace, in the first sentence, the word “requires” with “recommends”.

---------------------- Page: 12 ----------------------
oSIST prEN IEC 61784-5-X:2022
– 2010 – IEC CDV 61784-5-2:2018/AMD1
© IEC 2022
215 B.4.4.7.5 Specific requirements for CPs
216 Replace “Not applicable” with the following new text and figures:
217 Addition:
218 CP 2/2 ranks the shield application according to the applied earthing and bonding system.
219 a) Star earthing
220 Ranking of preferred shield termination application in a star earthing arrangement is
221 shown in Figure B.19 in order from left to right.
Most Least
Preferred Preferred
Double Single
Hybrid Single AC
Isolated Point
Earthing Earth
Earthing Earth
222
223 Figure B.19 – Shield termination in star earthing arrangements
224 b) Equipotential/mesh earthing
225 In equiptential/mesh earthing arrangements, application of direct grounding at multiple
226 points of the cable is preferred (see Figure B.20).
227
228 Figure B.20 – shield termination in mesh earthing arrangements
229 B.5.3.1 Common description
230 Replace, in the third sentence of the last paragraph, “see Figure H.2 of IEC 61918:2018” with
231 “see IEC 61918:2018, Annex H and IEC 61918:2018/AMD1:—, Annex H”.
232 B.5.7.4.4 Derivatives of direct and parallel RC
233 Replace, at the beginning of the fourth sentence of the first paragraph, the word “requires”
234 with “recommends”.
235 Replace the last paragraph with the following new paragraph:
236 If the active device provides a low DC resistance (less than 500 kΩ) to earth at the jack and
237 connects to a link partner device that also provides a low DC resistance to earth at its jack, an
238 equalizing shunt conductor shall be used to mitigate earth voltage offsets between the two
239 end points, see IEC 61918:2018, Figure 35. The sizing of the conductor shall be in
240 accordance with IEC 61918:2018, Table 14.
241 B.6.2.1 General
242 Replace the fifth bulleted item with the following new bulleted item:
243 • presence of dust caps for unused connectorized cabling and equipment;

---------------------- Page: 13 ----------------------
oSIST prEN IEC 61784-5-X:2022
IEC CDV 61784-5-2:2018/AMD1
© IEC 2022 – 2011 –
244 Replace the seventh bulleted item with the following new bulleted item:
245 • routing of cables with respect to other circuits according to IEC 61918:2018, Table 17.
246 B.6.2.5.1 Verification of cable routing
247 Replace list items a) and b) with the following new list items a) and b):
248 a) The length of the end-to-end link or a channel is the sum of the lengths of the fixed
249 horizontal cables and cords between the two end points. The length of a permanent link is
250 the sum of the fixed horizontal cable and any intermediary cords not including those cords
251 connecting directly to the end equipment. Length of the link/channel may be determined by
252 physically measuring the length(s) of the cable(s), determined from the length markings on
253 the cable(s), when present.
254 b) The length of the permanent link shall not be greater than 90 m (295 ft). The length of the
255 end-to-end link or channel shall not be greater than 100 m (328 ft), including equipment
256 cords and patch cords. If the channel or permanent link has been de-rated because of
257 temperature or cable attenuation, then the total channel length is less than 100 m (328 ft)
258 and the permanent link will be less than 90 m (295 ft). See the derating tables in
259 IEC 61918:2018, Table 11 and Table 12.
260 B.6.3.2.1.1 Common description
261 Replace the last paragraph with the following new paragraph:
262 Electrical performance testing shall be performed either on the end-to-end link, channel, or
263 permanent link or any combination thereof.
264
265 Bibliography
266 Add, at the end of Bibliography, the following new references:
267 [45] ODVA: PUB00148: EtherNet/IP Media Planning & Installation Manual, 2006, available at
268
269 [46] ANSI/TIA-5017 – Telecommunications Physical Network Security Standard, February
270 2016
271
272 ___________

---------------------- Page: 14 ----------------------
oSIST prEN IEC 61784-5-X:2022
– 3002 – IEC CDV 61784-5-3:2018/AMD1
  © IEC 2022
1 INTERNATIONAL ELECTROTECHNICAL COMMISSION
2 ____________
3
4 INDUSTRIAL COMMUNICATION NETWORKS –
5 PROFILES –
6
7 Part 5-3: Installation of fieldbuses –
8 Installation profiles for CPF 3
9
10 AMENDMENT 1
11
12 FOREWORD
13 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
14 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
15 co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
16 in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
17 Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
18 preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
19 may participate in this preparatory work. International, governmental and non-governmental organizations liaising
20 with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
21 Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
22 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
23 consensus of opinion on the relevant subjects since each technical committee has representation from all
24 interested IEC National Committees.
25 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
26 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
27 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
28 misinterpretation by any end user.
29 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
30 transparently to the maximum extent possible in their national and regional publications. Any divergence between
31 any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
32 5)
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.