Abstract

This document shall cover, regardless if manufactured in factories or in temporary plants on site under the same conditions, prefabricated reinforced components of autoclaved aerated concrete with a dry density between 250 and 1000 kg/m3 to be used in building construction as:
—   solid, hollow core and multilayer wall elements intended to be used as structural elements;
—   solid, hollow core and multilayer wall elements intended to be used as non-structural elements and if relevant for applications in contact with soil and ground water;
—   retaining walls intended to be used as structural elements and if relevant for applications in contact with soil and ground water;
—   solid, hollow core and multilayer roof elements intended to be used as structural elements;
—   solid, hollow core and multilayer floor elements intended to be used as structural elements;
—   solid, hollow core beams intended to be used as structural elements;
—   solid piers intended to be used as structural elements and if relevant for applications in contact with soil and ground water;
—   cladding elements intended to be used as non-loadbearing elements;
—   rectangular cross-section box culverts intended not to be used as structural elements and if relevant for applications in contact with soil and ground water;
—   components for noise barriers intended not to be used as structural elements and if relevant for applications in contact with soil and ground water.
This document does not cover:
—   retaining walls intended to retain tanks or reservoirs of liquids;
—   precast diaphragm walls (concrete sheet piling);
—   ribbed floor elements;
—   lintels.

Status
Not Published
Public Enquiry End Date
25-Sep-2025
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
10-Jun-2026
Due Date
29-Jul-2026

Buy Documents

Draft

oSIST prEN 12602:2025

English language (76 pages)
Preview
Preview
e-Library read for
×1 day

kSIST FprEN 12602:2026 is the draft European Standard for precast autoclaved aerated concrete (AAC) products. It sets the product characteristics, test methods, assessment rules and factory production control for reinforced AAC components used in building construction, so manufacturers, laboratories, notified bodies and specifiers can work from the same technical basis.

What does kSIST FprEN 12602:2026 specify?

kSIST FprEN 12602:2026 covers prefabricated reinforced AAC components made in factories or in temporary plants on site under the same conditions. It applies to products with a dry density between 250 and 1000 kg/m3 used as structural or non-structural building elements, including cases where the product may be in contact with soil and ground water.

The scope includes wall, roof, floor and beam elements, plus retaining walls, solid piers, cladding elements, rectangular cross-section box culverts and noise-barrier components. It excludes retaining walls for tanks or reservoirs of liquids, precast diaphragm walls, ribbed floor elements and lintels.

The document is organized into clauses on terms and symbols, characteristics, testing and assessment, AVCP, and Annex ZA, which links the standard to EU construction-product requirements.

AnnexWhat it covers
Annex ZARelationship with Regulation (EU) No. 305/2011, relevant characteristics, AVCP system and task assignment

What are the key requirements of kSIST FprEN 12602:2026?

kSIST FprEN 12602:2026 focuses on declared product performance, how to test it, and how to keep production consistent. In practice, the standard tells a manufacturer what to measure, what a purchaser can ask for, and what a notified body or lab may need to verify.

  • AAC material properties in Clause 4.1 and testing in Clause 5.1. The standard covers characteristic compressive strength, dry density, modulus of elasticity, drying shrinkage, creep, freeze-thaw resistance and corrosion protection. These are the basic material data used for design, durability checks and product declaration.

  • Reinforcing steel properties in Clause 4.2 and Clause 5.2. It specifies elongation at maximum load, elongation after fracture, stress ratio, tensile yield strength and ultimate tensile strength. This matters because the reinforcement has to suit the structural role of the element and its handling and transport loads.

  • Mechanical performance in Clause 4.3 and Clause 5.3. The document includes flexural strength, longitudinal load, loadbearing capacity under transverse load, and joint rigidity in in-plane and out-of-plane shear. These results support structural verification for walls, floors, roofs, beams and piers.

  • Fire performance in Clauses 4.4 and 4.5. Reaction to fire is class declared, and resistance to fire is addressed as EI, R, REI, EI-M and REI-M class declarations with testing. Clause 5.4 allows Euroclass A1 without testing when equally distributed organic material is below the stated limit, and Clause 5.5 points to the fire test and classification standards used for different element types.

  • Thermal, water and acoustic performance in Clauses 4.6 to 4.8. The standard covers thermal conductivity, water vapour resistance factor, airborne sound insulation, impact sound insulation and sound absorption. These properties matter for energy design, moisture control and acoustic comfort.

  • Mass and transportation weight in Clause 4.9 and Clause 5.9. The standard requires the element mass to be declared and includes a rule for transport-weight density when manufacturer data are not available, with a specific note for beams. This supports logistics, lifting plans and transport calculations.

  • Dangerous substances in Clauses 4.10 and 4.11, with test methods in 5.10 and 5.11. The standard covers emissions to indoor air and leaching to soil and ground water, using defined substance lists and rounding rules. For practice, this means the product can be checked for the intended exposure route and the result reported in a controlled way.

  • Environmental sustainability and documentation in Clauses 4.12, 4.13, 5.12 and 5.13. The standard includes reference service life, life cycle assessment, resource use, waste, output flows and biogenic carbon, plus the documentation to accompany the declaration of performance. For custom-made products, the attached documents must include the relevant load and exposure scenarios and the calculations or tabulated values behind them.

Clause 6 sets out AVCP: performance may be assessed by testing, calculation, tabulated values or descriptive documentation, and the manufacturer must operate factory production control. It also covers initial inspection, continuous surveillance and validation of environmental sustainability company-specific data.

What terms does kSIST FprEN 12602:2026 define?

  • Autoclaved aerated concrete (AAC) - Concrete with a dry density between 250 and 1000 kg/m3 made from binders, fine siliceous material, recycled aggregates, a cell-generating material and water, then cut and steam-cured in autoclaves.

  • Reinforcement - The strengthening material in the component, commonly steel mats, cages or bars, used either for loadbearing function or for handling, transport and construction.

  • Corrosion protective coating - A coating applied to reinforcement to protect it against corrosion.

  • Pier - The vertical loadbearing part of a wall between or beside openings.

  • Fire wall - A wall that separates two spaces and is designed for fire resistance and structural stability.

  • Factory production control (FPC) - The manufacturer’s internal production control system used to keep product performance consistent under AVCP.

Who uses kSIST FprEN 12602:2026?

kSIST FprEN 12602:2026 is used by manufacturers of precast AAC products, including factories and temporary on-site plants working under the same conditions. It is also used by test laboratories, notified bodies, designers, structural engineers, quality managers and procurement teams who need to specify, test, check or buy AAC elements.

It is especially relevant for building construction projects using structural walls, roofs, floors, beams and piers, and for products with non-structural, lining or infrastructure uses such as cladding, box culverts and noise barriers. The standard is also important where products may be exposed to fire, moisture, sound, soil or ground water.

What changed in kSIST FprEN 12602:2026 from the previous edition?

kSIST FprEN 12602:2026 supersedes EN 12602:2016. The foreword states these changes from the previous edition:

  • the text was adjusted to the product-category rules
  • the text was aligned with the European Commission standardization request for precast concrete products under Regulation (EU) No. 305/2011
  • terms and definitions were updated
  • the order of clauses changed
  • AAC parameters were adapted
  • normative references were added and dated
  • product properties and requirements were updated, including acoustic properties and thermal resistance
  • Annexes A to H were deleted and Annex ZA was adapted

Which standards are used with kSIST FprEN 12602:2026?

Standard(s)What they contribute
EN 678, EN 679, EN 680, EN 990, EN 1352, EN 1355, EN 1356, EN 15304AAC density, strength, shrinkage, corrosion protection, modulus, creep, transverse-load and freeze-thaw test methods
EN 1739, EN 1740, EN 1741Joint shear and longitudinal-load performance for prefabricated AAC components
EN 1745, EN 12664, EN ISO 10456Thermal-property methods and declared/design thermal values
EN 13501-1, EN ISO 1182, EN ISO 1716Reaction-to-fire classification
EN 13501-2, EN 1363-2, EN 1364-1, EN 1365-1, EN 1365-2, EN 1365-3, EN 1365-4Fire-resistance classification and element-specific fire testing
EN 16516Emissions into indoor air
EN 16637-1, EN 16637-2Leaching tests for soil and ground water exposure
EN 15804+A2:2019 and prEN 18185:2025Environmental product-declaration and sustainability rules
EN ISO 354, EN ISO 717-1, EN ISO 717-2, EN ISO 10140-1, EN ISO 10140-2, EN ISO 10140-3, EN ISO 10140-5, EN ISO 12354-2Sound absorption, laboratory sound insulation testing, rating and calculation
ISO 16269-6Statistical tolerance intervals used in assessment

What does the kSIST FprEN 12602:2026 document contain?

The document contains the characteristic requirements for AAC material properties, reinforcement, mechanical performance, fire, thermal, water, acoustic and environmental performance. It also contains test, sampling and assessment methods, including the way emissions and leaching results are derived and rounded, and a transport-weight rule for elements.

Annex ZA maps product types to essential characteristics and AVCP tasks for declaration of performance and CE marking. The document also includes documentation requirements for off-the-shelf and custom-made products, including drawings, dimensions, tolerances, materials, load scenarios and calculation references.

Relations

Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026
Effective Date
04-Nov-2026

Buy Documents

Draft

oSIST prEN 12602:2025

English language (76 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

kSIST FprEN 12602:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Precast autoclaved aerated concrete products". This standard covers: This document shall cover, regardless if manufactured in factories or in temporary plants on site under the same conditions, prefabricated reinforced components of autoclaved aerated concrete with a dry density between 250 and 1000 kg/m3 to be used in building construction as: — solid, hollow core and multilayer wall elements intended to be used as structural elements; — solid, hollow core and multilayer wall elements intended to be used as non-structural elements and if relevant for applications in contact with soil and ground water; — retaining walls intended to be used as structural elements and if relevant for applications in contact with soil and ground water; — solid, hollow core and multilayer roof elements intended to be used as structural elements; — solid, hollow core and multilayer floor elements intended to be used as structural elements; — solid, hollow core beams intended to be used as structural elements; — solid piers intended to be used as structural elements and if relevant for applications in contact with soil and ground water; — cladding elements intended to be used as non-loadbearing elements; — rectangular cross-section box culverts intended not to be used as structural elements and if relevant for applications in contact with soil and ground water; — components for noise barriers intended not to be used as structural elements and if relevant for applications in contact with soil and ground water. This document does not cover: — retaining walls intended to retain tanks or reservoirs of liquids; — precast diaphragm walls (concrete sheet piling); — ribbed floor elements; — lintels.

This document shall cover, regardless if manufactured in factories or in temporary plants on site under the same conditions, prefabricated reinforced components of autoclaved aerated concrete with a dry density between 250 and 1000 kg/m3 to be used in building construction as: — solid, hollow core and multilayer wall elements intended to be used as structural elements; — solid, hollow core and multilayer wall elements intended to be used as non-structural elements and if relevant for applications in contact with soil and ground water; — retaining walls intended to be used as structural elements and if relevant for applications in contact with soil and ground water; — solid, hollow core and multilayer roof elements intended to be used as structural elements; — solid, hollow core and multilayer floor elements intended to be used as structural elements; — solid, hollow core beams intended to be used as structural elements; — solid piers intended to be used as structural elements and if relevant for applications in contact with soil and ground water; — cladding elements intended to be used as non-loadbearing elements; — rectangular cross-section box culverts intended not to be used as structural elements and if relevant for applications in contact with soil and ground water; — components for noise barriers intended not to be used as structural elements and if relevant for applications in contact with soil and ground water. This document does not cover: — retaining walls intended to retain tanks or reservoirs of liquids; — precast diaphragm walls (concrete sheet piling); — ribbed floor elements; — lintels.

kSIST FprEN 12602:2026 is classified under the following ICS (International Classification for Standards) categories: 91.100.30 - Concrete and concrete products. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN 12602:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 1716:2018, SIST EN 1356:2001, SIST EN 18185:2026, SIST EN 1365-3:2001, SIST EN 16516:2018+A1:2020, SIST EN 16637-2:2024, SIST EN 13501-2:2023, SIST EN 1740:2001, SIST EN 1365-4:1999, SIST ISO 16269-6:2015, SIST EN ISO 11925-2:2026, SIST EN ISO 717-1:2021, SIST EN 15304:2010, SIST EN 1793-1:2026, SIST EN ISO 6892-1:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

kSIST FprEN 12602:2026 is associated with the following European legislation: EU Directives/Regulations: 305/2011; Standardization Mandates: M/100, M/609, M/627. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

kSIST FprEN 12602:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions, symbols and abbreviations
  • 3.1 Terms and definitions
  • 3.1.1 autoclaved aerated concrete
  • 3.1.2 raw materials
  • 3.1.3 reinforcement
  • 3.1.4 corrosion protective coating
  • 3.1.5 pier
  • 3.1.6 fire wall
  • 3.2 Symbols
  • 4 Characteristics
  • 4.1 Autoclaved aerated concrete (AAC)
  • 4.2 Reinforcing steel
  • 4.3 Mechanical performance
  • 4.4 Reaction to fire – class declaration
  • 4.5 Resistance to fire
  • 4.6 Thermal performance
  • 4.7 Water performance
  • 4.8 Acoustic performance
  • 4.9 Other performances – Mass of element
  • 4.10 Release of dangerous substances – indoor air
  • 4.11 Release of dangerous substances – soil and ground water
  • 4.12 Environmental sustainability
  • 4.13 Documents to be provided together with the declaration of performance
  • 5 Testing, assessment and sampling methods
  • 5.1 Autoclaved aerated concrete (AAC)
  • 5.2 Reinforcing steel
  • 5.3 Mechanical performance
  • 5.4 Reaction to fire – class declaration
  • 5.5 Resistance to fire – class declaration – testing
  • 5.6 Thermal performance
  • 5.7 Water performance
  • 5.8 Acoustic performance
  • 1. For a mass unit area m’ in the range 50 kg/m ≤ m’ < 150 kg/m
  • 2. For a mass unit area m’ges in the range 150 kg/m ≤ m’ < 300 kg/m
  • 5.9 Other performances
  • 5.10 Release of dangerous substances – indoor air
  • 5.11 Release of dangerous substances – soil and ground water
  • 5.12 Environmental sustainability
  • 5.13 Performances in attached documentation of the product
  • 6 Assessment and verification of constancy of performance – AVCP
  • 6.1 General
  • 6.2 Assessment of performance
  • 6.3 Verification of constancy of performance
  • Annex ZA
  • 6.3 manufacturer (FPC)
  • 6.3 FPC
  • 6.3 ZA.1.12 relevant for the intended
  • 6.3 Competence as regards the provision
  • 6.3 of performances in attached
  • 6.3 for the intended use which are
  • 6.3 validate any company-
  • Bibliography

1 Scope

This document shall cover, regardless if manufactured in factories or in temporary plants on site under the same conditions, prefabricated reinforced components of autoclaved aerated concrete with a dry

density between 250 and 1000 kg/m to be used in building construction as:

  • solid, hollow core and multilayer wall elements intended to be used as structural elements;
  • solid, hollow core and multilayer wall elements intended to be used as non-structural elements and if relevant for applications in contact with soil and ground water;
  • retaining walls intended to be used as structural elements and if relevant for applications in contact with soil and ground water;
  • solid, hollow core and multilayer roof elements intended to be used as structural elements;
  • solid, hollow core and multilayer floor elements intended to be used as structural elements;
  • solid, hollow core beams intended to be used as structural elements;
  • solid piers intended to be used as structural elements and if relevant for applications in contact with soil and ground water;
  • cladding elements intended to be used as non-loadbearing elements;
  • rectangular cross-section box culverts intended not to be used as structural elements and if relevant for applications in contact with soil and ground water;
  • components for noise barriers intended not to be used as structural elements and if relevant for applications in contact with soil and ground water.

This document does not cover:

  • retaining walls intended to retain tanks or reservoirs of liquids;
  • precast diaphragm walls (concrete sheet piling);
  • ribbed floor elements;
  • lintels.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 678:1993, Determination of the dry density of autoclaved aerated concrete EN 679:2005, Determination of the compressive strength of autoclaved aerated concrete EN 680:2005, Determination of the drying shrinkage of autoclaved aerated concrete EN 990:2002, Test methods for verification of corrosion protection of reinforcement in autoclaved aerated concrete and lightweight aggregate concrete with open structure

oSIST prEN 12602:2025 prEN 12602:2025 (E) EN 1352:1996, Determination of static modulus of elasticity under compression of autoclaved aerated concrete or lightweight aggregate concrete with open structure EN 1355:1996, Determination of creep strains under compression of autoclaved aerated concrete or lightweight aggregate concrete with open structure EN 1356:1996, Performance test for prefabricated reinforced components of autoclaved aerated concrete or lightweight aggregate concrete with open structure under transverse load EN 1363-2:1999, Fire resistance tests - Part 2: Alternative and additional procedures EN 1364-1:2015, Fire resistance tests for non-loadbearing elements - Part 1: Walls EN 1365-1:2012, Fire resistance tests for loadbearing elements - Part 1: Walls EN 1365-2:2014, Fire resistance tests for loadbearing elements - Part 2: Floors and roofs EN 1365-3:1999, Fire resistance tests for loadbearing elements - Part 3: Beams EN 1365-4:1999, Fire resistance tests for loadbearing elements - Part 4: Columns EN 1739:2007, Determination of shear strength for in-plane forces of joints between prefabricated components of autoclaved aerated concrete or lightweight aggregate concrete with open structure EN 1740:1998, Performance test for prefabricated reinforced components made of autoclaved aerated concrete or lightweight aggregate concrete with open structure under predominantly longitudinal load (vertical components) EN 1741:1998, Determination of shear strength for out-of-plane forces of joints between prefabricated components made of autoclaved aerated concrete or lightweight aggregate concrete with open structure EN 1745:2020, Masonry and masonry products - Methods for determining thermal properties EN 12664:2001, Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Dry and moist products of medium and low thermal resistance EN 13501-1:2018, Fire classification of construction products and building elements - Part 1: Classification using data from reaction to fire tests EN 13501-2:2023, Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance and/or smoke control tests, excluding ventilation services EN 15304:2010, Determination of the freeze-thaw resistance of autoclaved aerated concrete

EN 15804:2012+A2:2019, Sustainability of construction works — Environmental product declarations — Core rules for the product category of construction products EN 16516:2017+A1:2020, Construction products: Assessment of release of dangerous substances - Determination of emissions into indoor air

As impacted by EN 15804:2012+A2:2019/AC:2021.

oSIST prEN 12602:2025 prEN 12602:2025 (E) EN 16637-1:2023, Construction products: Assessment of release of dangerous substances - Part 1: Guidance for the determination of leaching tests and additional testing steps EN 16637-2:2023, Construction products: Assessment of release of dangerous substances - Part 2:

Horizontal dynamic surface leaching test prEN 18185:2025, Sustainability of construction works - Environmental product declarations - Product Category Rules for precast lightweight concrete with an open structure and precast autoclaved aerated concrete EN ISO 354:2003, Acoustics - Measurement of sound absorption in a reverberation room (ISO 354:2003) EN ISO 717-1:2020, Acoustics - Rating of sound insulation in buildings and of building elements - Part 1:

Airborne sound insulation (ISO 717-1:2020) EN ISO 717-2:2020, Acoustics - Rating of sound insulation in buildings and of building elements - Part 2:

Impact sound insulation (ISO 717-2:2020) EN ISO 10140-1:2021, Acoustics - Laboratory measurement of sound insulation of building elements - Part 1: Application rules for specific products (ISO 10140-1:2021) EN ISO 10140-2:2021, Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation (ISO 10140-2:2021) EN ISO 10140-3:2021, Acoustics - Laboratory measurement of sound insulation of building elements - Part 3: Measurement of impact sound insulation (ISO 10140-3:2021) EN ISO 10140-5:2021, Acoustics - Laboratory measurement of sound insulation of building elements - Part 5: Requirements for test facilities and equipment (ISO 10140-5:2021)

EN ISO 10456:2007, Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values (ISO 10456) EN ISO 12354-2:2017, Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 2: Impact sound insulation between rooms (ISO 12354-2:2017) ISO 16269-6:2014, Statistical interpretation of data — Part 6: Determination of statistical tolerance intervals

3 Terms and definitions, symbols and abbreviations

3.1 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp/
  • IEC Electropedia: available at https://www.electropedia.org/

As impacted by EN ISO 10456:2007/AC:2009.

oSIST prEN 12602:2025 prEN 12602:2025 (E)

3.1.1 autoclaved aerated concrete

AAC

concrete with a dry density between 250 and 1000 kg/m that is manufactured from binders such as cement and/or lime combined with fine siliceous based material, recycled aggregates, cell generating material and water whereby the raw materials are mixed together and cast into moulds where the mix is allowed to rise and set into cakes Note 1 to entry: After this part of the process, the cake is cut into the required sizes of components and cured with high pressure steam in autoclaves.

3.1.2 raw materials

constituents which combined with additives and agents, where appropriate, can be used in the manufacturing process

3.1.3 reinforcement

strengthening material that is commonly composed of steel mats, cages and/or steel bars Note 1 to entry: Other types of reinforcement can be used. Depending on the function of the components, the reinforcement can be structural or non-structural.

Note 2 to entry: Structural reinforcement is reinforcement which is necessary for the loadbearing function of the component as part of the structure. It consists of steel.

Note 3 to entry: Non-structural reinforcement is reinforcement which is necessary in order to ensure adequate resistance of the component during handling, transportation and construction. Any suitable kind of reinforcement may be used for this purpose.

3.1.4 corrosion protective coating

coating applied on the surface of the reinforcement to protect the reinforcement against corrosion

3.1.5 pier

vertical loadbearing part of the wall between or besides openings

3.1.6 fire wall

wall separating two spaces (generally two fire compartments or buildings) that is designed for fire resistance and structural stability Note 1 to entry: A fire wall may include resistance to horizontal loading (criterion M) such that in case of fire and failure of the structure on one side of the wall, fire spread beyond the wall is avoided (so that a fire wall is designated REI-M or EI-M).

3.2 Symbols

3.2.1 General symbols

b width of component d effective depth or thickness of component, diameter (e.g. of a bar) E modulus of elasticity

oSIST prEN 12602:2025 prEN 12602:2025 (E) f strength F force h depth or thickness of component k coefficient, factor l length, height of wall component, span length of roof or floor components M bending moment N axial force R resistance, loadbearing capacity V shear force ε strain

3.2.2 Subscripts

c concrete parameter, compression comp component cr critical dry in the dry state g declared value k characteristic value l longitudinal m mean or mass R resistance s steel parameter, shear t tension test in testing u ultimate y yield value (for steel)

3.2.3 Symbols used in this European Standard

d effective depth of a component f characteristic compressive strength of AAC ck fck,g declared characteristic compressive strength of AAC f tensile strength of reinforcing steel st f yield strength of reinforcing steel y f characteristic yield strength of reinforcing steel yk f characteristic yield strength of the stirrups ywk f characteristic 0,2 % proof stress of reinforcing steel 0,2k N axial force (compression positive)

oSIST prEN 12602:2025 prEN 12602:2025 (E) ε mean conventional reference value of shrinkage cs,ref ε total value of drying shrinkage cs,tot ε short-term prestrain

λ thermal conductivity in the dry state at a mean test temperature of 10 °C 10dry µ water vapour resistance factor µ mass related moisture content m ρ dry density of AAC ρ characteristic dry density of AAC (95 % – quantile) k ρm mean value of the dry density of AAC ρ mean of the upper and lower limit of the density class m,g Δρ declared tolerance of the dry density of AAC g ρ density to be used for calculation of transportation weight of AAC-components trans φ final creep coefficient

3.2.4 Abbreviations

AAC autoclaved aerated concrete FPC factory production control NDP Nationally Determined Parameter RH relative humidity

4 Characteristics

4.1 Autoclaved aerated concrete (AAC)

4.1.1 Characteristic compressive strength

The characteristic compressive strength is applicable for all products mentioned in the scope but not for solid, hollow core and multilayer non-load bearing wall elements and cladding elements. The characteristic value of the compressive strength of AAC shall be determined in accordance with 5.1.1 and expressed in MPa, rounded to the nearest 0,1.

The characteristic compressive strength of AAC shall be classified as compressive strength class in accordance with Table 1.

Table 1 — Compressive strength classes Strengths in MPa AAC AAC AAC AAC AAC AAC AAC AAC AAC AAC AAC AAC AAC Strength class 1,5 2 2,5 3 3,5 4 4,5 5 6 7 8 9 10 f 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 6,0 7,0 8,0 9,0 10,0 ck

4.1.2 Dry density

The dry density is applicable for all products mentioned in the scope.

oSIST prEN 12602:2025 prEN 12602:2025 (E) The dry density shall be determined in accordance with 5.1.2 and expressed as a a class as specified in

Table 2 and expressed in kg/m , rounded to the nearest 10.

The expression (ρ + Δρ ) shall be taken as the upper limit and the expression (ρ – Δρ ) as the lower m,g g m,g g limit of the mean dry density, ρ as specified in Table 2.

m Table 2 — Density classes

Dry densities in kg/m Density class 300 350 400 450 500 550 600 650 > 250 > 300 > 350 > 400 > 450 > 500 > 550 > 600 Mean dry density ρm ≤ 300 ≤ 350 ≤ 400 ≤ 450 ≤ 500 ≤ 550 ≤ 600 ≤ 650 Density class 700 750 800 850 900 950 1000 > 650 > 700 > 750 > 800 > 850 > 900 > 950 Mean dry density ρ m ≤ 700 ≤ 750 ≤ 800 ≤ 850 ≤ 900 ≤ 950 ≤ 1 000

4.1.3 Modulus of elasticity
4.1.3.1 Modulus of elasticity – testing

The modulus of elasticity is applicable for all products mentioned in the scope. The modulus of elasticity E , shall be determined in accordance with 5.1.3.1. The modulus of elasticity cm shall be expressed in MPa and rounded to the nearest 100.

4.1.3.2 Modulus of elasticity – calculation

When assessed the mean value of the modulus of elasticity shall be obtained in accordance with 5.1.3.2. The modulus of elasticity shall be expressed in MPa and rounded to the nearest 100

4.1.4 Drying shrinkage – testing

The drying shrinkage is applicable for all products mentioned in the scope. The value of drying shrinkage shall be determined in accordance with 5.1.4. and shall be expressed as shrinkage class as specified in Table 3.

Table 3 — Drying shrinkage classes for AAC Drying shrinkage in mm/m Drying shrinkage class 0,15 0,20 0,25 0,30 0,35 0,40 ε cs,ref ≤ 0,15 ≤ 0,20 ≤ 0,25 ≤ 0,30 ≤ 0,35 ≤ 0,40 mm/m

4.1.5 Creep – testing

Creep is applicable for all products mentioned in the scope but not for solid, hollow core and multilayer non-load bearing wall elements, cladding elements, box culverts and components for noise barriers. The creep coefficient shall be indicated by the manufacturer on the basis of results of tests according to 5.1.5. The performance of creep shall be expressed in ‰ and rounded to 0,01.

4.1.6 Freeze–thaw resistance

The freeze–thaw resistance is applicable for all products mentioned in the scope. The assessment of the freeze–thaw resistance is in accordance with 5.1.6 The performance shall be expressed by the number of the executed freeze–thaw cycles.

oSIST prEN 12602:2025 prEN 12602:2025 (E)

4.1.7 Corrosion protection

The corrosion protection is applicable for all products mentioned in the scope. The assessment of the corrosion protection is in accordance with 5.1.7. The performance is expressed by the proportion of the corroded surface area of the steel, expressed in % and rounded to 1.

4.2 Reinforcing steel

4.2.1 General

The characteristics for the reinforcing steel are applicable for all products mentioned in the scope.

4.2.2 Elongation at maximum load

The elongation at maximum load of reinforcing steel (A ) shall be determined in accordance with 5.2.1. gt The performance of elongation at maximum load of reinforcing steel shall be expressed as a ratio, rounded to the nearest 0,1.

4.2.3 Elongation after fracture

When assessing the elongation after fracture this shall be in accordance with 5.2.2 and expressed as a percentage, rounded to the nearest 0,1 %.

4.2.4 Stress ratio

When assessing the stress ratio of steel or stainless steel, the this shall be in accordance with 5.2.3 and expressed as a percentage, rounded to the nearest 0,01 %.

4.2.5 Tensile yield strength

When assessing the tensile yield strength of reinforcing steel (R ) this shall be determined in accordance e with 5.2.4. The performance of tensile yield strength of reinforcing steel shall be expressed in MPa, rounded to the nearest integer.

4.2.6 Ultimate tensile strength

When assessing the ultimate tensile strength of reinforcing steel (R ) this shall be determined in m accordance with 5.2.5. The performance of ultimate tensile strength of reinforcing steel shall be expressed in MPa, rounded to the nearest integer.

4.3 Mechanical performance

4.3.1 Mechanical strength – testing – flexural strength

The flexural strength is applicable for all products mentioned in the scope. When assessing the mechanical strength of elements for bending this shall be determined in accordance with 5.3.2.

4.3.2 Mechanical strength – testing – longitudinal load

The mechanical strength for longitudinal load is applicable for all products mentioned in the scope but not for solid, hollow core and multilayer non-load bearing wall elements, retaining wall elements, solid, hollow core and multilayer roof elements, solid, hollow core and multilayer floor elements, cladding elements, box culverts and components for noise barriers.

When assessing the mechanical strength of elements under longitudinal load this shall be determined following 5.3.3.

oSIST prEN 12602:2025 prEN 12602:2025 (E)

4.3.3 Mechanical strength – testing – loadbearing capacity under transverse load

The mechanical strength under transverse load is applicable for all products mentioned in the scope but not for solid, hollow core and multilayer loadbearing wall elements. When assessing the loadbearing capacity under transverse load this shall be determined following 5.3.4.

4.3.4 Mechanical strength – testing – rigidity of joints – in-plane shear

The rigidity of joints – in-plane shear is applicable for all products mentioned in the scope but not for solid, hollow core beams, solid piers, box culverts and components for noise barriers. When using the rigidity of joints in design the mechanical strength of joints under in-plane-shear shall be determined in accordance with 5.3.5.

4.3.5 Mechanical strength – testing – rigidity of joints – out-of-plane shear

The rigidity of joints – in-plane shear is applicable for all products mentioned in the scope but not for solid, hollow core beams, solid piers, box culverts and components for noise barriers. When using the rigidity of joints in design the mechanical strength of joints under in-plane-shear shall be determined following 5.3.6.

4.4 Reaction to fire – class declaration

4.4.1 General

The reaction to fire is applicable for all products mentioned in the scope. AAC shall be tested in accordance with 5.4 and classified as specified in EN 13501-1:2018. If the content of equally distributed organic material is less than 1 % by mass or volume (whichever is the more onerous), the AAC is classified in Euroclass A1 without the need for testing [7].

4.4.2 Classification without testing

Whether products covered by this document fulfil the conditions, under which they have demonstrated of having a stable reaction to fire performance in a given reaction to fire class, based on testing to the appropriate EN test methods, the established assigned class applies to these products without the need of carrying out further reaction to fire tests.

NOTE The rules to apply this classification are published as Commission Decisions or Commission Delegated Regulations.

...