(Main)Thermoplastics pipes and fittings -- Vicat softening temperature -- Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes
Thermoplastics pipes and fittings -- Vicat softening temperature -- Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes
Specifies the particular test conditions for determining the Vicat softening temperature of PVC-U and PVC-C pipes and fittings as well as PVC-HI pipes (the general test method is given in ISO 2507-1). Also gives, for information, the corresponding basic specifications.
Tubes et raccords en matières thermoplastiques -- Température de ramollissement Vicat -- Partie 2: Conditions particulières d'essai pour tubes et raccords en poly(chlorure de vinyle) non plastifié (PVC-U) ou en poly(chlorure de vinyle) chloré (PVC-C) et tubes en poly(chlorure de vinyle) à résistance au choc améliorée (PVC-HI)
Plastomerne cevi in fitingi - Zmehčišče po Vicatu (VST) - 2. del: Preskusni pogoji za cevi in fitinge iz nemehčanega polivinilklorida (PVC - U) in kloriranega polivinilklorida (PVC - C) ter za cevi iz visoko na udar odpornega polivinilklorida (PVC - HI)
General Information
- Status
- Published
- Publication Date
- 31-Oct-1995
- Technical Committee
- PCV - Plastic pipes, fittings and valves
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Nov-1995
- Due Date
- 01-Nov-1995
- Completion Date
- 01-Nov-1995
Relations
- Effective Date
- 12-May-2008
Overview
ISO 2507-2:1995 - Thermoplastics pipes and fittings - Vicat softening temperature - Part 2 specifies the particular test conditions for determining the Vicat softening temperature (VST) of PVC materials used in pipes and fittings. It applies to unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly(vinyl chloride) (PVC-C) and high impact resistance poly(vinyl chloride) (PVC-HI) pipes and fittings. The general test method is given in ISO 2507-1:1995; this Part 2 adds material‑specific conditions and informative basic VST specifications.
Key Topics and Requirements
- Purpose: define test conditions to determine the Vicat softening temperature for PVC-U, PVC-C and PVC-HI pipework components.
- Normative reference: relies on the general procedure, apparatus, specimen preparation, conditioning, procedure and reporting defined in ISO 2507-1.
- Material scope:
- PVC-U (pipes and moulded fittings)
- PVC-C (pressure and non‑pressure pipes and fittings)
- PVC-HI (high impact resistance pipes)
- Informative basic VST specifications (given in annexes A–C):
- PVC-U pipes: not less than 79 °C
- PVC-U moulded fittings: not less than 77 °C
- PVC-C pressure pipes: not less than 110 °C
- PVC-C fittings: not less than 103 °C
- PVC-C non‑pressure pipes: not less than 90 °C
- PVC-HI pipes: not less than 76 °C
- Annexes A, B and C provide basic specification values for information; product standards may specify more stringent limits for particular applications.
Applications and Who Uses It
- Manufacturers of PVC-U, PVC-C and PVC-HI pipes and fittings use ISO 2507-2 for product testing and quality control to demonstrate temperature performance.
- Test laboratories and certification bodies apply the specified test conditions when reporting Vicat softening temperature for compliance and labeling.
- Engineers, specifiers and procurement professionals use VST data to select pipe materials for temperature-critical fluid transport systems (e.g., hot water, industrial services).
- Regulators and standards committees reference these test conditions when developing or harmonizing product standards and safety requirements.
Related Standards
- ISO 2507-1:1995 - Thermoplastics pipes and fittings - Vicat softening temperature - Part 1: General test method (primary reference for apparatus and procedure).
- ISO 2507 series includes Part 3 for ABS and ASA materials (material‑specific test conditions for other thermoplastics).
Keywords: ISO 2507-2:1995, Vicat softening temperature, PVC-U, PVC-C, PVC-HI, thermoplastics pipes, test conditions, pipe fittings, VST, material specification.
ISO 2507-2:1995 - Thermoplastics pipes and fittings — Vicat softening temperature — Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes Released:2/2/1995
ISO 2507-2:1995 - Tubes et raccords en matières thermoplastiques — Température de ramollissement Vicat — Partie 2: Conditions particulières d'essai pour tubes et raccords en poly(chlorure de vinyle) non plastifié (PVC-U) ou en poly(chlorure de vinyle) chloré (PVC-C) et tubes en poly(chlorure de vinyle) à résistance au choc améliorée (PVC-HI) Released:2/2/1995
Frequently Asked Questions
SIST ISO 2507-2:1995 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Thermoplastics pipes and fittings -- Vicat softening temperature -- Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes". This standard covers: Specifies the particular test conditions for determining the Vicat softening temperature of PVC-U and PVC-C pipes and fittings as well as PVC-HI pipes (the general test method is given in ISO 2507-1). Also gives, for information, the corresponding basic specifications.
Specifies the particular test conditions for determining the Vicat softening temperature of PVC-U and PVC-C pipes and fittings as well as PVC-HI pipes (the general test method is given in ISO 2507-1). Also gives, for information, the corresponding basic specifications.
SIST ISO 2507-2:1995 is classified under the following ICS (International Classification for Standards) categories: 23.040.20 - Plastics pipes; 23.040.45 - Plastics fittings. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST ISO 2507-2:1995 has the following relationships with other standards: It is inter standard links to ISO 2507:1982. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST ISO 2507-2:1995 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-november-1995
3ODVWRPHUQHFHYLLQILWLQJL=PHKþLãþHSR9LFDWX967GHO3UHVNXVQLSRJRML
]DFHYLLQILWLQJHL]QHPHKþDQHJDSROLYLQLONORULGD39&8LQNORULUDQHJD
SROLYLQLONORULGD39&&WHU]DFHYLL]YLVRNRQDXGDURGSRUQHJDSROLYLQLONORULGD
39&+,
Thermoplastics pipes and fittings -- Vicat softening temperature -- Part 2: Test conditions
for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C)
pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes
Tubes et raccords en matières thermoplastiques -- Température de ramollissement Vicat
-- Partie 2: Conditions particulières d'essai pour tubes et raccords en poly(chlorure de
vinyle) non plastifié (PVC-U) ou en poly(chlorure de vinyle) chloré (PVC-C) et tubes en
poly(chlorure de vinyle) à résistance au choc améliorée (PVC-HI)
Ta slovenski standard je istoveten z: ISO 2507-2:1995
ICS:
23.040.20 Cevi iz polimernih materialov Plastics pipes
23.040.45 Fitingi iz polimernih Plastics fittings
materialov
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
INTERNATIONAL ISO
STANDARD 2507-2
First edition
1995-02-15
Thermoplastics pipes and fittings -
Vicat softening temperature -
Part 2:
Test conditions for unplasticized poly(vinyl
chloride) (PVC-U) or chlorinated poly(vinyl
chloride) (PVC-C) pipes and fittings and for
high impact resistance poly(vinyl chloride)
(PVC-H 1) pipes
Tubes et raccords en maG-es thermoplastiques - Temperature de
ramollissemen t Vita t -
Partie 2: Conditions particuli&es d ’essai pour tubes et raccords en
poly(chlorure de vinyle) non plastifik (PVC-lJ) ou en poly(chlorure de vinyle)
chlor6 (PVC-C) et tubes en poly(chlorure de vinyle) 2 rksktance au choc
amklior6e (PVC-Hl)
Reference number
ISO 2507=2:1995(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide
federation of national Standards bodies (ISO member bodies). The work
of preparing International Standards is normally carried out through ISO
technical committees. Esch member body interested in a subject for
which a technical committee has been established has the right to be
represented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work. ISO
collaborates closely with the International Electrotechnical Commission
(IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are
circulated to the member bodies for voting. Publication as an International
Standard requires approval by at least 75 % of the member bodies casting
a vote.
International Standard ISO 2507-2 was prepared by Technical Committee
lSO/TC 138, Plastics pipes, fittings and valves for the transport of fluids,
Subcommittee SC 5, General properties of pipes, fittings and valves of
plastic materials and their accessories - Test methods and basic specifi-
ca tions.
This first edition of ISO 2507-2, and ISO 2507-1, cancels and replaces the
second edition of ISO 2507 (ISO 2507:1982), of which it constitutes a
technical revision.
ISO 2507 consists of the following Parts, under the general title Thermo-
plastics pipes and fittings - Vita t softening tempera ture:
- Part 7: General test method
- Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U)
or chlorinated poly(vinyl chloride) (PVC-C) p@es and fittings and for
high Impact resistance poly(viny/ chloride) (PVC-Hl) pipes
- Part 3: Test conditions for acrylonitrile/butadiene/styrene (ABS) and
acrylonitrile/styrene/acrylic ester (ASA) pipes and fittings
Annexes A, B and C of this part of ISO 2507 are for information only.
0 ISO 1995
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any
...
INTERNATIONAL ISO
STANDARD 2507-2
First edition
1995-02-15
Thermoplastics pipes and fittings -
Vicat softening temperature -
Part 2:
Test conditions for unplasticized poly(vinyl
chloride) (PVC-U) or chlorinated poly(vinyl
chloride) (PVC-C) pipes and fittings and for
high impact resistance poly(vinyl chloride)
(PVC-H 1) pipes
Tubes et raccords en maG-es thermoplastiques - Temperature de
ramollissemen t Vita t -
Partie 2: Conditions particuli&es d ’essai pour tubes et raccords en
poly(chlorure de vinyle) non plastifik (PVC-lJ) ou en poly(chlorure de vinyle)
chlor6 (PVC-C) et tubes en poly(chlorure de vinyle) 2 rksktance au choc
amklior6e (PVC-Hl)
Reference number
ISO 2507=2:1995(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide
federation of national Standards bodies (ISO member bodies). The work
of preparing International Standards is normally carried out through ISO
technical committees. Esch member body interested in a subject for
which a technical committee has been established has the right to be
represented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work. ISO
collaborates closely with the International Electrotechnical Commission
(IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are
circulated to the member bodies for voting. Publication as an International
Standard requires approval by at least 75 % of the member bodies casting
a vote.
International Standard ISO 2507-2 was prepared by Technical Committee
lSO/TC 138, Plastics pipes, fittings and valves for the transport of fluids,
Subcommittee SC 5, General properties of pipes, fittings and valves of
plastic materials and their accessories - Test methods and basic specifi-
ca tions.
This first edition of ISO 2507-2, and ISO 2507-1, cancels and replaces the
second edition of ISO 2507 (ISO 2507:1982), of which it constitutes a
technical revision.
ISO 2507 consists of the following Parts, under the general title Thermo-
plastics pipes and fittings - Vita t softening tempera ture:
- Part 7: General test method
- Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U)
or chlorinated poly(vinyl chloride) (PVC-C) p@es and fittings and for
high Impact resistance poly(viny/ chloride) (PVC-Hl) pipes
- Part 3: Test conditions for acrylonitrile/butadiene/styrene (ABS) and
acrylonitrile/styrene/acrylic ester (ASA) pipes and fittings
Annexes A, B and C of this part of ISO 2507 are for information only.
0 ISO 1995
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any means, electronie or mechanical, tncluding photocopying and
microfilm, without Permission in writing from the publisher.
International Organization for Standardization
Case Postale 56 l CH-1 211 Geneve 20 l Switzerland
Printed in Switzerland
ISO 2507=2:1995(E)
INTERNATIONAL STANDARD 0 ISO
Thermoplastics pipes and fittings - Vicat softening
temperature -
Part 2:
Test conditions for unplasticized poly(vinyl chloride)
(PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes
and fittings and for high impact resistance poly(vinyl
chloride) (PVC-H 1) pipes
Standard indicated below. Members of IEC and ISO
1 Scope
maintain registers of currently valid International
Standards.
This part of ISO 2507 specifies the particular test
conditions for determining the Vi
...
NORME
ISO
INTERNATIONALE 2507-Z
Première édition
1995-02-I 5
Tubes et raccords en matières
- Température de
thermoplastiques
ramollissement Vicat -
Partie 2:
Conditions particulières d’essai pour tubes et
raccords en poly(chlorure de vinyle) non
plastifié (PVC-U) ou en poly(chlorure de vinyle)
chloré (PVC-C) et tubes en poly(chlorure de
vinyle) à résistance au choc améliorée
(PVC-H 1)
Thermoplastics pipes and fittings - Vicat softening temperature -
Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-lJ) or
chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high
impact resistance poly(vinyl chloride) (PVC-HI) pipes
Numéro de référence
ISO 2507=2:1995(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération
mondiale d’organismes nationaux de normalisation (comités membres de
I’ISO). L’élaboration des Normes internationales est en général confiée aux
comités techniques de I’ISO. Chaque comité membre intéressé par une
étude a le droit de faire partie du comité technique créé à cet effet. Les
organisations internationales, gouvernementales et non gouvernemen-
tales, en liaison avec I’ISO participent également aux travaux. L’ISO colla-
bore étroitement avec la Commission électrotechnique internationale (CEI)
en ce qui concerne la normalisation électrotechnique.
Les projets de Normes internationales adoptés par les comités techniques
sont soumis aux comités membres pour vote. Leur publication comme
Normes internationales requiert l’approbation de 75 % au moins des co-
mités membres votants.
La Norme internationale ISO 2507-Z a été élaborée par le comité techni-
que lSO/TC 138, Tubes, raccords et robinetterie en matières plastiques
pour le transport des fluides, sous-comité SC 5, Propriétés générales des
tubes, raccords et robinetteries en matières plastiques et leurs accessoi-
Méthodes d’essais et spécifications de base.
res -
Cette première édition de I’ISO 2507-Z ainsi que I’ISO 2507-I annulent et
remplacent la deuxième édition (ISO 2507:1982), dont elle constitue une
révision technique.
LYS0 2507 comprend les parties suivantes, présentées sous le titre gé-
néral Tubes et raccords en matières thermoplastiques - Température de
ramollissement Vica t:
- Partie 7: Méthode générale d’essai
- Partie 2: Conditions particulières d’essai pour tubes et raccords en
poly(chlorure de vinyle) non plastifié (PVC-U) ou en poly(chlorure de
vinyle) chloré (PVC-C) et tubes en poly(chlorure de vinyle) à résis-
tance au choc améliorée (PVC-HI)
- Partie 3: Conditions particulières d’essai pour tubes et raccords en
acrylonitrile/butadiène/styrène (ABS) et en acrylonitrile/styrène/ester
acrylique (ASA)
0 ISO 1995
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publi-
cation ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun pro-
cédé, électronique ou mécanique, y compris la photocopie et les mtcrofilms, sans l’accord
écrit de l’éditeur.
Organisation internationale de normalisation
Case Postale 56 l CH-l 211 Genève 20 l Suisse
Imprimé en Suisse
II
0 ISO ISO 2507-2: 1995(F)
Les annexes A, B et C de la présente partie de I’ISO 2507 sont données
uniquement à titre d’information.
Page blanche
ISO 2507-2: 1995(F)
NORME INTERNATIONALE 0 ISO
Tubes et raccords en matières thermoplastiques -
Température de ramollissement Vicat -
Partie 2:
)ns particulières d’essai pour tubes et raccords en
Conditi
orure de vinyle) non plastifié (PVC-U) ou en
poly(ch
orure de vinyle) chloré (PVC-C) et tubes en
poly(ch
orure de vinyle) à résistance au choc améliorée
poly(ch
(PVC-H
présente partie de I’ISO 2507 sont invitées à recher-
1 Domaine d’application
cher la possibilité d’appliquer l’édition la plus récente
de la norme indiquée ci-après. Les membres de la CEI
La présente partie de I’ISO 2507 prescrit les condi-
et de I’ISO possèdent le registre des Normes inter-
tions particulières d’essai pour déterminer la tempé-
nationales en vigueur à un moment donné.
rature de ramollissement Vicat (VST) des tubes et des
raccords en pol
...


















Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.