SIST EN 1399:1999/AC:1999
(Amendment)Resilient floor coverings - Determination of resistance to stubbed and burning cigarettes
Resilient floor coverings - Determination of resistance to stubbed and burning cigarettes
TC - Corrections to references
Revetements de sol résilients - Détermination de la résistance aux brulures de cigarettes et aux cigarettes écrasées
Netekstilne talne obloge - Ugotavljanje odpornosti proti cigaretnim ogorkom in žarečim cigaretam
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Revetements de sol résilients - Détermination de la résistance aux brulures de cigarettes et aux cigarettes écraséesResilient floor coverings - Determination of resistance to stubbed and burning cigarettes97.150Netekstilne talne oblogeNon-textile floor coverin
...
This May Also Interest You
This European Standard specifies two methods, for determining the resistance of resilient floor coverings to stubbed and burning cigarettes.
- Standard7 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Feb-1999
- 13.220.40
- 97.150
- 305/2011
- 89/106/EEC
- ITEK
This document specifies a method for assessing the wind-opposed burning behaviour and spread of flame of horizontally mounted floorings exposed to a heat flux radiant gradient in a test chamber, when ignited with pilot flames. Annex A gives details of assessing the smoke development, when required.
This method is applicable to all types of flooring, e.g. textile carpet, cork, wood, rubber and plastics coverings as well as coatings. Results obtained by this method reflect the reaction to fire performance of the flooring, including any substrate if used. Modifications of the backing, bonding to a substrate, underlay or other changes of the flooring can affect test results. It cannot be used alone to describe or appraise the fire hazard or fire risk of floorings under actual fire conditions.
Information on the precision of the test method is given in Annex B.
- Standard38 pagesEnglish languagesale 10% offe-Library read for×1 day
The method established applies to all types of textile floor coverings independent of their construction or their fibre composition. The method may also be applicable to unfinished material. In this case, the result does not indicate the behaviour of the material in the condition in which is used.
- Standard3 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard3 pagesEnglish languagesale 15% off
- Standard3 pagesFrench languagesale 15% off
- Standard3 pagesFrench languagesale 15% off
ISO 9239-1:2010 specifies a method for assessing the wind-opposed burning behaviour and spread of flame of horizontally mounted floorings exposed to a heat flux radiant gradient in a test chamber, when ignited with pilot flames.
This method is applicable to all types of flooring. e.g. textile carpet, cork, wood, rubber and plastics coverings as well as coatings. Results obtained by this method reflect the performance of the flooring, including any substrate if used. Modifications of the backing, bonding to a substrate, underlay or other changes of the flooring may affect test results.
ISO 9239-1:2010 is applicable to the measurement and description of the properties of floorings in response to heat and flame under controlled laboratory conditions. It should not be used alone to describe or appraise the fire hazard or fire risk of floorings under actual fire conditions.
- Standard25 pagesEnglish languagesale 15% off
- Standard26 pagesFrench languagesale 15% off
ISO 9239-2 specifies a method for assessing the burning behaviour of horizontally mounted flooring systems exposed to a heat flux gradient in a test chamber, when ignited with pilot flames. The radiant heat gradient is higher than the one described in ISO 9239-1 in order to simulate conditions in a corridor adjacent to a room containing a fully developed fire (post-flashover).
This method is applicable to all types of flooring such as textile carpets, cork, wood, rubber and plastic coverings as well as coatings. Results obtained by this method reflect the performance of the flooring, including any substrate if used. Modifications of the backing, bonding to a substrate, underlay, or other changes of the flooring may affect test results.
This part of ISO 9239 is applicable to the measurement and description of the properties of floorings in response to heat and flame under controlled laboratory conditions. It should not be used alone to describe or appraise the fire hazard or fire risk of floorings under actual fire conditions.
- Standard20 pagesEnglish languagesale 15% off
This document defines the terms used in ultrasonic non-destructive testing and forms a common basis for standards and general use.
This document does not cover specific terms used in ultrasonic testing with arrays.
NOTE Terms used in ultrasonic testing with arrays are defined in ISO 23243.
- Standard55 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies three procedures, A, B and C, using the Pensky-Martens closed cup tester, for determining the flash point of combustible liquids, liquids with suspended solids, liquids that tend to form a surface film under the test conditions, biodiesel and other liquids in the temperature range of 40 °C to 370 °C.
NOTE 1 Although, technically, kerosene with a flash point above 40 °C can be tested using this document, it is standard practice to test kerosene according to ISO 13736.[5] Similarly, lubricating oils are normally tested according to ISO 2592.[2]
Procedure A is applicable to distillate fuels (diesel, biodiesel blends, heating oil and turbine fuels), new and in-use lubricating oils, paints and varnishes, and other homogeneous liquids not included in the scope of procedures B or C.
Procedure B is applicable to residual fuel oils, cutback residuals, used lubricating oils, mixtures of liquids with solids, and liquids that tend to form a surface film under test conditions or are of such kinematic viscosity that they are not uniformly heated under the stirring and heating conditions of procedure A.
Procedure C is applicable to fatty acid methyl esters (FAME) as specified in specifications such as EN 14214[11] or ASTM D6751.[13]
This document is not applicable to water-borne paints and varnishes.
NOTE 2 Water-borne paints and varnishes can be tested using ISO 3679.[3] Liquids containing traces of highly volatile materials can be tested using ISO 1523[1] or ISO 3679.
- Standard35 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies methods for the determination of acrylamide in coffee and coffee products by extraction with water, clean-up by solid-phase extraction (SPE) and determination by high-performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS) and gas chromatography with mass spectrometric detection (GC-MS) after derivatization. The methods were validated in a validation study for roasted coffee, soluble coffee, coffee substitutes and coffee products with ranges from 53 μg/kg to 612,1 μg/kg.
- Standard32 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies requirements and test methods for E20 petrol marketed and delivered as such, containing a minimum oxygen content of 3,7 % (m/m) and a maximum of 8,0 % (m/m). The fuel has a maximum of 20,0 % (V/V) ethanol.
It is applicable to fuel for use in spark-ignition petrol-fuelled engines and vehicles.
This document is complementary to EN 228, which describes unleaded petrol containing an oxygen content up to 3,7 % (m/m) and a maximum ethanol content of 10 % (V/V).
NOTE 1 For general petrol engine vehicle warranty, E20 petrol might not be suitable for all vehicles and it is advised that the recommendations of the vehicle manufacturer are consulted before use. E20 petrol might need a validation step to confirm the compatibility of the fuel with the vehicle, which for some existing engines might still be needed.
NOTE 2 For the purposes of this document, the terms “% (m/m)” and “% (V/V)” are used to represent respectively the mass fraction, µ, and the volume fraction, φ.
- Technical specification16 pagesEnglish languagesale 10% offe-Library read for×1 day
This document is applicable to the basic safety and essential performance of sleep apnoea breathing therapy equipment, hereafter referred to as ME equipment, intended to alleviate the symptoms of patients who suffer from obstructive sleep apnoea by delivering a therapeutic breathing pressure to the respiratory tract of the patient. Sleep apnoea breathing therapy equipment is intended for use in the home healthcare environment by lay operators as well as in professional healthcare institutions.
Sleep apnoea breathing therapy equipment is not considered to utilize a physiologic closed-loop-control system unless it uses a physiological patient variable to adjust the therapy settings.
This document excludes sleep apnoea breathing therapy equipment intended for use with neonates.
This document is applicable to ME equipment or an ME system intended for those patients who are not dependent on artificial ventilation. This document is not applicable to ME equipment or an ME system intended for those patients who are dependent on artificial ventilation such as patients with central sleep apnoea.
This document is also applicable to those accessories intended by their manufacturer to be connected to sleep apnoea breathing therapy equipment, where the characteristics of those accessories can affect the basic safety or essential performance of the sleep apnoea breathing therapy equipment.
Masks and application accessories intended for use during sleep apnoea breathing therapy are additionally addressed by ISO 17510. Refer to Figure AA.1 for items covered further under this document.
If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.
Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of the general standard.
NOTE 2 See also 4.2 of the general standard.
This document does not specify the requirements for:
– ventilators or accessories intended for critical care ventilators for ventilator-dependent patients, which are given in ISO 80601‑2‑12.
– ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601-2-13.
– ventilators or accessories intended for home care ventilators for ventilator-dependent patients, which are given in ISO 80601-2-72.
– ventilators or accessories intended for emergency and transport, which are given in ISO 80601-2-84.
– ventilators or accessories intended for home-care ventilatory support, which are given in ISO 80601‑2-79 and ISO 80601‑2‑80.
– high-frequency ventilators[23], which are given in ISO 80601-2-87.
– respiratory high flow equipment, which are given in ISO 80601‑2‑90;
NOTE 3 ISO 80601-2-80 ventilatory support equipment can incorporate high-flow therapy operational mode, but such a mode is only for spontaneously breathing patients.
– user-powered resuscitators, which are given in ISO 10651-4;
– gas-powered emergency resuscitators, which are given in ISO 10651-5;
– oxygen therapy constant flow ME equipment; and
– cuirass or “iron-lung” ventilation equipment.
- Standard89 pagesEnglish languagesale 10% offe-Library read for×1 day








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...