Abstract

This document specifies a method for extraction, separation, and determination of inorganic arsenic in organic or organo-mineral fertilizers using anion-exchange high performance liquid chromatography (HPLC) or ion chromatography (IC) coupled to ICP-MS.
This document is applicable to fertilizing product blends, where a blend is a mix of at least two of the following components: fertilizers, liming materials, soil improvers, growing media, inhibitors, plant biostimulants and where the following category organic fertilizer or organo-mineral fertilizer is the highest % in the blend by mass or volume, or in the case of liquid form by dry mass. If the organic fertilizer or the organo-mineral fertilizer is not the highest % in the blend, the European Standard for the highest % of the blend applies. In case a fertilizing product blend is composed of components in equal quantity, the user decides which standard to apply.
NOTE   Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.

Status
Not Published
Public Enquiry End Date
01-Apr-2026
Technical Committee
KAT - Soil quality
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
17-Nov-2026
Due Date
05-Jan-2027

Buy Documents

Draft

oSIST prEN 17775:2026

English language (21 pages)
Preview
Preview
e-Library read for
×1 day

kSIST FprEN 17775:2026 is a draft European Standard prepared by CEN/TC 260 and listed by SIST. It specifies how to extract, separate and determine inorganic arsenic in organic and organo-mineral fertilizers using anion-exchange HPLC or IC coupled to ICP-MS, for laboratories and analysts checking fertilizer materials and fertilizing product blends.

What does kSIST FprEN 17775:2026 specify?

kSIST FprEN 17775:2026 specifies a test method for inorganic arsenic in organic and organo-mineral fertilizers. The method covers the analytical workflow from extraction to chromatographic separation, detection, calculation and reporting.

The document also explains how it applies to fertilizing product blends. Where the blend contains at least two components and the organic fertilizer or organo-mineral fertilizer is the highest percentage component by mass, volume, or dry mass for liquid forms, this document applies. If another component is present in the highest amount, the European Standard for that component applies instead. If components are present in equal quantity, the user decides which standard to apply.

Sampling is not part of the method itself. Clause 5 points users to EN 1482-1 and EN 1482-3 for recommended sampling methods and to EN 1482-2 for sample preparation.

AnnexWhat it covers
Annex AExamples of typical chromatographic separation, including original and spiked samples
Annex BResults of the inter-laboratory study and statistical precision data

The document is organized into clauses on scope, normative references, terms and definitions, principle, sampling, reagents, apparatus, procedure, calculation and expression of results, precision and test report.

What are the key requirements of kSIST FprEN 17775:2026?

kSIST FprEN 17775:2026 is built around a mild acid oxidative extraction followed by chromatographic separation and ICP-MS detection. In practice, the user must prepare the sample carefully, control blanks, verify separation, and report results on a dry matter basis.

Extraction and sample handling

Clause 4 states that the sample portion is treated with diluted nitric acid and hydrogen peroxide in a heated water bath. This solubilizes the sample and oxidizes As(III) to As(V), which means the method targets the inorganic arsenic species after conversion to a measurable form.

Clause 8 requires solid samples to be milled and homogenized, while liquid samples are mixed thoroughly before weighing the test portion. This matters because uneven particles or poor mixing can change what enters the test portion and affect the result.

The extraction uses a defined extraction solution, a heated shaking water bath, centrifugation and filtration before analysis. The practical point is that users must follow the same extraction conditions for test samples, blanks and controls to keep the measurement comparable.

Reagents, blanks and separation

Clause 6 puts strong emphasis on reagent purity and low blank levels because ICP-MS is highly sensitive. The method expects ultra-pure water, high-purity nitric acid and hydrogen peroxide, and it recommends checking reagent contamination before use. In practice, users need to treat water, acids and mobile phase components as potential sources of arsenic background.

Clause 8 requires a blank test solution and external calibration. The blank is used to identify background contribution, and the calibration solutions are prepared in the extraction solution so the standards match the sample matrix as closely as possible.

Clause 8 also requires verification of chromatographic separation. The method uses an anion-exchange column, with arsenate separated from other arsenic species and chloride monitored to avoid interference. This means the analyst has to confirm that arsenate is resolved from chloride and from other arsenic compounds before relying on the result.

Measurement, calculation and quality control

Clause 8 allows HPLC-ICP-MS or IC-ICP-MS, and it gives example instrument settings in Table 1. The important point is not the exact instrument brand, but that the system must be optimized so arsenic is measured consistently under stable chromatographic conditions.

Clause 9 calculates inorganic arsenic as a mass fraction in mg/kg on a dry matter basis. The result is corrected for blank value and dilution, and the dry matter content used in the calculation comes from prEN 17773. In practice, the laboratory must know the dry matter content of the sample before it can report the final result correctly.

Clause 10 gives precision information based on an inter-laboratory study, including repeatability and reproducibility limits. This helps users judge whether two results are close enough to be considered consistent, and it gives a realistic picture of method performance in routine use.

Clause 11 requires the test report to identify the sample, the method used, the result, the sampling date if known, the analysis dates, and any deviations or unusual features. For users, this means the report must contain enough detail for traceability and for reviewing anything that could have influenced the outcome.

What terms does kSIST FprEN 17775:2026 define?

  • Analyte - the parameter being determined, here the inorganic arsenic content.
  • Blank calibration solution - a calibration solution prepared without the analytes, used to set the analytical baseline.
  • Blank test solution - a solution prepared like the sample solution but without the test portion, used to measure background contribution.
  • Calibration solution - a solution used to calibrate the instrument, made from stock solutions and prepared with the same matrix as needed.
  • Stock solution - a solution with accurately known analyte concentration, prepared from pure chemicals.
  • Test sample solution - the solution produced after extraction or digestion of the test sample and used for measurement.
  • Inorganic arsenic (iAs) - the arsenic species targeted by the method, consisting of arsenite As(III) and arsenate As(V).

Who uses kSIST FprEN 17775:2026?

kSIST FprEN 17775:2026 is used by analytical laboratories, quality control teams and technical staff working with organic fertilizers, organo-mineral fertilizers and fertilizing product blends. It is relevant wherever these products need to be checked for inorganic arsenic content against limit values.

The document is also useful to manufacturers and product developers who need to verify compliance during product development or routine batch control. Its blend rules matter to users who test mixed fertilizing products and need to decide which standard applies before analysis starts.

Because the document warns that staff must be suitably trained, it is aimed at people who already work with laboratory extraction, chromatography and ICP-MS. It also helps laboratories decide when a preliminary total arsenic measurement can be used to reduce the number of samples that need full iAs determination.

What changed in kSIST FprEN 17775:2026 from the previous edition?

kSIST FprEN 17775:2026 supersedes CEN/TS 17775:2022. The foreword lists these significant technical changes:

  • the CEN Technical Specification was adopted as a European Standard;
  • Clause 1 was updated, including clarification for fertilizing product blends;
  • normative references to dry matter content determination were added;
  • normative references to sampling were added;
  • terms and definitions were revised;
  • the test report was revised;
  • the bibliography was revised;
  • Annex A was revised;
  • Annex B was added.

Which standards are used with kSIST FprEN 17775:2026?

  • prEN 17773 - provides the dry matter content used in the calculation of results on a dry matter basis.
  • prEN 12944-1 - supplies general fertilizer vocabulary used in the terms and definitions.
  • prEN 12944-2 - supplies fertilizer-related vocabulary used with the method terminology.
  • EN 1482-2 - gives the general sample preparation provisions required before analysis.
  • EN 1482-1 - gives recommended general sampling provisions mentioned for representative sampling.
  • EN 1482-3 - gives sampling provisions for static heaps, which may be relevant to fertilizer sampling.
  • prEN 17768 - provides aqua regia digestion for a preliminary total arsenic check.
  • prEN 17770 - provides total element determination by ICP-AES after aqua regia digestion, also mentioned as a preliminary screening option.
  • ISO 5725-2 - provides the statistical basis used for repeatability and reproducibility in the precision study.

What does the kSIST FprEN 17775:2026 document contain?

kSIST FprEN 17775:2026 contains the full analytical method, including reagent preparation, apparatus requirements, extraction steps, calibration, measurement and calculation. It also gives an example mobile phase approach, a test-report checklist and precision data.

Table 1 provides example HPLC-ICP-MS operating settings, and Table 2 gives repeatability and reproducibility limits from the precision study. Annex A shows representative chromatograms for original and spiked samples, which helps users check separation and chloride interference. Annex B summarizes the inter-laboratory study, including the sample set and statistical results used to support method performance.

Relations

Effective Date
01-Mar-2026

Buy Documents

Draft

oSIST prEN 17775:2026

English language (21 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

Control Union Certifications

Global certification for agriculture and sustainability.

RVA Netherlands Verified

ECOCERT

Organic and sustainability certification.

COFRAC France Verified

FSC International

Forest Stewardship Council certification.

ASI Germany Verified

Sponsored listings

Frequently Asked Questions

kSIST FprEN 17775:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Organic and organo-mineral fertilizers - Determination of the inorganic arsenic content". This standard covers: This document specifies a method for extraction, separation, and determination of inorganic arsenic in organic or organo-mineral fertilizers using anion-exchange high performance liquid chromatography (HPLC) or ion chromatography (IC) coupled to ICP-MS. This document is applicable to fertilizing product blends, where a blend is a mix of at least two of the following components: fertilizers, liming materials, soil improvers, growing media, inhibitors, plant biostimulants and where the following category organic fertilizer or organo-mineral fertilizer is the highest % in the blend by mass or volume, or in the case of liquid form by dry mass. If the organic fertilizer or the organo-mineral fertilizer is not the highest % in the blend, the European Standard for the highest % of the blend applies. In case a fertilizing product blend is composed of components in equal quantity, the user decides which standard to apply. NOTE Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.

This document specifies a method for extraction, separation, and determination of inorganic arsenic in organic or organo-mineral fertilizers using anion-exchange high performance liquid chromatography (HPLC) or ion chromatography (IC) coupled to ICP-MS. This document is applicable to fertilizing product blends, where a blend is a mix of at least two of the following components: fertilizers, liming materials, soil improvers, growing media, inhibitors, plant biostimulants and where the following category organic fertilizer or organo-mineral fertilizer is the highest % in the blend by mass or volume, or in the case of liquid form by dry mass. If the organic fertilizer or the organo-mineral fertilizer is not the highest % in the blend, the European Standard for the highest % of the blend applies. In case a fertilizing product blend is composed of components in equal quantity, the user decides which standard to apply. NOTE Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.

kSIST FprEN 17775:2026 is classified under the following ICS (International Classification for Standards) categories: 65.080 - Fertilizers. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN 17775:2026 has the following relationships with other standards: It is inter standard links to SIST-TS CEN/TS 17775:2023. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

kSIST FprEN 17775:2026 is associated with the following European legislation: EU Directives/Regulations: 2019/1009; Standardization Mandates: M/564. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

kSIST FprEN 17775:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 analyte
  • 3.2 blank calibration solution
  • 3.3 blank test solution
  • 3.4 calibration solution
  • 3.5 stock solution
  • 3.6 test sample solution
  • 4 Principle
  • 5 Sampling
  • 6 Reagents
  • 6.1 General
  • 6.6 Ammonium carbonate, (NH ) CO , mass fraction w ≥ 99,999 %, for preparation of the mobile
  • 6.11 Arsenic (V) standard solution I, with an arsenic (V) mass concentration of 10 mg/l in 2 %
  • 7 Apparatus
  • 8 Procedure
  • 8.1 Sample preparation
  • 8.2 Water bath extraction
  • 8.3 Preparation of the calibration solutions
  • 8.4 Measurement
  • 9 Calculation and expression of the results
  • 9.1 Integration of peaks
  • 9.2 Calculation of inorganic arsenic in the samples
  • 10 Precision
  • 10.1 Inter-laboratory study
  • 10.2 Repeatability
  • 10.3 Reproducibility
  • 11 Test report
  • Annex A
  • 1 Inorganic As (V) (m/z 75)
  • 2 Cl (m/z 35)
  • 2 Cl (m/z 35)
  • Annex B
  • Bibliography

Introduction

The method is based on a mild acid oxidative extraction of the arsenic species followed by liquid chromatography (high performance liquid chromatography [HPLC] or ion chromatography [IC]) coupled to the element-specific detector ICP-MS (inductively coupled plasma mass spectrometer) for the determination of the mass fraction of inorganic arsenic (iAs). Other standards developed for determination of inorganic arsenic content in plant biostimulants, animal feeding stuffs and foodstuffs were studied and considered as a basis of the described method [2], [3], [4], [5], [6].

The inter-laboratory study reflects the final statistical characteristics of the method for the determination of inorganic arsenic content in organic and organo-mineral fertilizers. The results are given in Annex B (informative).

To prove the compliance with existing limit values for inorganic arsenic in organic and organo-mineral fertilizers, there is the possibility to choose between:

 Using a test method determining the total arsenic content, as long as the result of the test shows a content below the limit value for inorganic arsenic. In such a case, it can be safely assumed that the organic fertilizer or the organo-mineral fertilizer complies with the limit value for inorganic arsenic.  Using a test method which determines only inorganic arsenic content. A preliminary determination of the total arsenic in aqua regia extracts by ICP-AES (inductively coupled plasma atomic emission spectrometry) according to prEN 17768 [8] and prEN 17770 [9] can reduce the number of the samples where the determination of iAs is necessary because if the content of aqua regia (total) extractable arsenic is lower than the legislative limit for iAs then the determination of iAs is not necessary. In case total As is measured and is presented above or equal the legislative limit for iAs, the content of inorganic As should be determined according to this document. WARNING — Persons using this document should be familiar with usual laboratory practice. This document does not purport to address all of the safety issues, if any, associated with its use. It is the responsibility of the user to establish appropriate health and safety practices and to ensure compliance with any national regulatory conditions.

IMPORTANT — It is absolutely essential that tests conducted according to this document are carried out by suitably trained staff.

oSIST prEN 17775:2026 prEN 17775:2026 (E)

1 Scope

This document specifies a method for extraction, separation, and determination of inorganic arsenic (iAs) in organic or organo-mineral fertilizers using anion-exchange high performance liquid chromatography (HPLC) or ion chromatography (IC) coupled to ICP-MS.

This document is applicable to fertilizing product blends where a blend is a mix of at least two of the following components: fertilizers, liming materials, soil improvers, growing media, inhibitors, plant biostimulants and where the following category organic fertilizer or organo-mineral fertiliser is the highest % in the blend by mass or volume, or in the case of liquid form by dry mass. If the organic fertilizer or the organo-mineral fertilizer is not the highest % in the blend, the European Standard for the highest % of the blend applies. In case a fertilizing product blend is composed of components in equal quantity, the user decides which standard to apply. Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. prEN 17773, Organic and organo-mineral fertilizers — Determination of the dry matter content prEN 12944-1, Fertilizers, liming materials and inhibitors — Vocabulary — Part 1: General terms prEN 12944-2, Fertilizers, liming materials and inhibitors — Vocabulary — Part 2: Terms relating to fertilizers EN 1482-2, Fertilizers, liming materials and inhibitors — Sampling and sample preparation — Part 2:

General sample preparation provisions

3 Terms and definitions

For the purposes of this document, the terms and definitions given in prEN 12944-1 and prEN 12944-2 and the following apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp/
  • IEC Electropedia: available at https://www.electropedia.org/

3.1 analyte

parameter to be determined

3.2 blank calibration solution

solution prepared in the same way as the calibration solution but leaving out the analytes

3.3 blank test solution

solution prepared in the same way as the test sample solution but omitting the test portion

oSIST prEN 17775:2026 prEN 17775:2026 (E)

3.4 calibration solution

solution used to calibrate the instrument, prepared from stock solutions by adding acids, buffer, reference element and salts as needed

3.5 stock solution

solution with accurately known analyte concentration(s), prepared from pure chemicals

3.6 test sample solution

solution prepared after extraction or digestion of the test sample according to appropriate specifications

4 Principle

This document specifies a method for the determination of inorganic arsenic in organic or organomineral fertilizers. Inorganic arsenic consists of arsenite As(III) and arsenate As(V). A representative test portion of the sample is treated with a diluted nitric acid and hydrogen peroxide solution in a heated water bath. By this means the sample is solubilised, arsenic species are extracted into solution and As(III) is oxidized to As(V). The inorganic arsenic is selectively separated from other arsenic compounds using anion exchange HPLC (high performance liquid chromatography) coupled online to the element-specific detector ICP-MS (inductively coupled plasma mass spectrometer) for the determination of the mass fraction of the inorganic arsenic. External calibration with solvent matrix-matched standards is used for the quantification of the amount of the inorganic arsenic. Alternatively, IC (ion chromatography) coupled to ICP-MS can be used.

5 Sampling

Sampling is not part of the method specified in this document. Recommended sampling methods are given in EN 1482-1 [11] and in EN 1482-3 [12].

It is important that the laboratory receives a sample that is representative of both the product under consideration and the given analysis. The sample should not have been damaged or changed during transport or storage.

Sample preparation shall be carried out in accordance with EN 1482-2.

6 Reagents

6.1 General

When using a method of high sensitivity like ICP-MS, the control of the blank levels of water, acid and other reagents is very important. The reagents shall be of adequate purity and of recognized analytical grade. The concentration of arsenic species in the reagents and water used shall be negligible and low enough not to affect the results of the determination. Generally, ultra-pure water and nitric acid of minimum p.a. quality is recommended.

6.2 Water, with an electrical conductivity not higher than 0,1 mS/m at 25 °C. 6.3 Nitric acid (HNO ), concentrated, ≥ 65 % (mass fraction), mass concentration of approximately ρ

(HNO ) 1,4 g/ml.

Use only nitric acid available with high purity (minimum p.a. quality) in order to avoid potential contamination.

oSIST prEN 17775:2026 prEN 17775:2026 (E) 6.4 Hydrogen peroxide, H O not less than 30 % (mass fraction). 2 2 High purity is essential to avoid potential contamination. Commercially available hydrogen peroxide for analysis should be tested for contamination of arsenic prior to use. It is necessary to prevent peroxide degradation and ensure the stability of the solution, this is in the discretion of the analyst to use only H O 2 2 of adequate quality.

6.5 Extraction solution, 0,1 mol/l HNO in 3 % (volume fraction) H O . 3 2 2 Add 6,5 ml of HNO (6.3) and thereafter 100 ml of hydrogen peroxide (6.4) into 800 ml water (6.2) in

a 1 000 ml volumetric flask. Fill the flask to the mark with water (6.2). This solution is prepared on the day of use.

It is recommended that the total volume needed for the analysis is estimated and only this amount is produced in the day of use.

6.6 Ammonium carbonate, (NH ) CO , mass fraction w ≥ 99,999 %, for preparation of the mobile

4 2 3 phase solution.

6.7 Aqueous ammonia, (NH (aq)), mass fraction w ≥ 25 %, for adjustment of pH in the mobile phase.

6.8 Methanol, (CH OH), HPLC grade, for preparation of the mobile phase solution.

6.9 Mobile phase, e.g. 50 mmol/l ammonium carbonate in 3 % (volume fraction) methanol at pH 10,3. Dissolve 4,80 g of ammonium carbonate (6.6) in approximately 800 ml water (6.2). Adjust the pH to 10,3 with aqueous ammonia (6.7) and add 30 ml of methanol (6.8) and then fill up to 1 000 ml with water (6.2). Prior to use filter the mobile phase solution through a 0,45 μm filter using a filtering device (7.4). The optimal concentration of ammonium carbonate in the mobile phase depends on the analytical column used (e.g. brand, particle size and dimensions) and should be verified in advance. The appropriate concentration of ammonium carbonate (usually between 10 mmol/l to 50 mmol/l) is highly dependent on the column used and is up to the discretion of the analyst. It should fulfil the criteria for sufficient resolution of the arsenate peak.

Methanol is added to the mobile phase in order to enhance the signal intensity for arsenic. The concentration of methanol to achieve the highest signal to noise ratio depends on the instrument used and should be identified by the analyst.

NOTE 1 Different mobile phase can be also used according to the instructions of the manufacturer of the column but it is necessary to verify the optimal separation conditions.

NOTE 2 For example, Agilent column G3154–65001 with a guard column G3154–65002 and a mobile phase recommended for this column, as a mixture of potassium dihydrogen phosphate (KH2PO4) 2 mmol/l, ethylenediaminetetraacetic acid disodium salt dihydrate (EDTA disodium salt) 0,2 mmol/l, pH 6,0 adjusted with sodium hydroxide (NaOH) 1 mol/l, were successfully used for the analysis. 6.10 Arsenic (V) standard stock solution, with an arsenic (V) mass concentration of 1 000 mg/l. The use of commercial standards of arsenic As(V), with a mass concentration of 1 000 mg/l is recommended.

1 ® Agilent is a registered trademark of Agilent Technologies Inc. This information is given for the convenience of users of this document and does not constitute an endorsement by CEN of the product named.

oSIST prEN 17775:2026 prEN 17775:2026 (E)

6.11 Arsenic (V) standard solution I, with an arsenic (V) mass concentration of 10 mg/l in 2 %

(volume fraction) HNO3.

Pipette 1 ml of arsenic standard stock solution (6.10) into a 100 ml volumetric flask. Add 2 ml of nitric acid (6.3), fill to the mark with water (6.2) and mix well. This solution is stable in a refrigerator at least one week.

...