FprEN 17775
(Main)Organic and organo-mineral fertilizers - Determination of the inorganic arsenic content
- Abstract
This document specifies a method for extraction, separation, and determination of inorganic arsenic in organic or organo-mineral fertilizers using anion-exchange high performance liquid chromatography (HPLC) or ion chromatography (IC) coupled to ICP-MS.
This document is applicable to fertilizing product blends, where a blend is a mix of at least two of the following components: fertilizers, liming materials, soil improvers, growing media, inhibitors, plant biostimulants and where the following category organic fertilizer or organo-mineral fertilizer is the highest % in the blend by mass or volume, or in the case of liquid form by dry mass. If the organic fertilizer or the organo-mineral fertilizer is not the highest % in the blend, the European Standard for the highest % of the blend applies. In case a fertilizing product blend is composed of components in equal quantity, the user decides which standard to apply.
NOTE Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.
- Status
- Not Published
- Publication Date
- 17-Feb-2027
- Technical Committee
- CEN/TC 260 - Fertilizers and liming materials
- Drafting Committee
- CEN/TC 260/WG 8 - Organic and organo-mineral fertilizers
- Current Stage
- 5020 - Submission to Vote - Formal Approval
- Start Date
- 29-Oct-2026
- Due Date
- 23-May-2027
- Completion Date
- 23-May-2027
FprEN 17775 is a CEN draft European Standard for determining inorganic arsenic (iAs) in organic and organo-mineral fertilizers. It specifies extraction, separation and measurement by anion-exchange HPLC or IC coupled to ICP-MS. Laboratories use it for compliance testing of fertilizers and fertilizing product blends, especially where the organic or organo-mineral fertilizer fraction is the dominant component.
What does FprEN 17775 specify?
FprEN 17775 specifies a laboratory method for inorganic arsenic in organic and organo-mineral fertilizers, and it also applies to certain fertilizing product blends. The method covers the analytical work - sample preparation, extraction, separation, measurement, calculation and reporting - while sampling itself is handled by other standards.
The document is organized into 11 clauses:
- Clause 1 Scope
- Clause 2 Normative references
- Clause 3 Terms and definitions
- Clause 4 Principle
- Clause 5 Sampling
- Clause 6 Reagents
- Clause 7 Apparatus
- Clause 8 Procedure
- Clause 9 Calculation and expression of the results
- Clause 10 Precision
- Clause 11 Test report
| Annex | What it covers |
|---|---|
| Annex A | Examples of typical chromatographic separation |
| Annex B | Results of the inter-laboratory study |
The scope matters in practice because it tells the user when this method applies to a blend and when another European Standard for the highest-percentage component should be used instead.
What are the key requirements of FprEN 17775?
Sample handling and extraction
FprEN 17775 requires a representative test portion to be extracted with a diluted nitric acid and hydrogen peroxide mixture in a heated water bath. The extraction is designed to solubilise the sample and convert arsenite As(III) to arsenate As(V), because the method measures iAs through arsenate after oxidation.
Clause 5 makes clear that sampling is outside the method, but sample preparation is not. Solid samples are milled and homogenized, liquid samples are mixed well, and the laboratory must protect the sample from damage or change during transport and storage.
Chromatographic separation and detection
FprEN 17775 separates inorganic arsenic from other arsenic species by anion-exchange HPLC, or alternatively IC, and couples the separation online to ICP-MS. The chromatographic system must resolve arsenate from nearby peaks, especially chloride, because chloride can create spectral interference at the arsenic mass.
This matters because poor separation can produce false results. The document therefore recommends checking separation with a mixed species solution, monitoring chloride during analysis, and optimizing mobile phase conditions if arsenate and chloride do not separate properly.
Calibration, blanks and quality control
FprEN 17775 uses external calibration with matrix-matched standards prepared in the extraction solution. The method requires a blank calibration solution and blank test solution, plus control samples or internal reference materials in each series.
In practice, this means the laboratory must verify background levels, watch for matrix suppression, and confirm that the instrument remains stable across the sequence. If a constant blank contribution is present, it is subtracted from the result; if reference materials are not available, spike experiments are used to check recovery.
Measurement conditions and interferences
FprEN 17775 measures arsenic at m/z 75 by ICP-MS, and it notes that triple quadrupole ICP-MS/MS can also be used with oxygen reaction gas to avoid chloride interference. The document also recommends allowing the HPLC system to equilibrate before analysis.
This section matters because the method depends on stable chromatographic conditions and good control of spectral interference. The analyst may need to adjust mobile phase concentration, flow rate, or the analytical column to reach acceptable separation.
Calculation, dry matter basis and reporting
FprEN 17775 calculates iAs as a mass fraction in mg/kg on a dry matter basis. The calculation uses the measured concentration in the sample solution, the blank value, the dilution factor, the extraction volume, the test portion mass and the dry matter content determined according to prEN 17773.
For users, this means the reported result is not just an instrument reading. It is a corrected result tied to the product’s dry matter content, which is important when comparing different solid or liquid products.
Precision and test report
FprEN 17775 includes repeatability and reproducibility information from an inter-laboratory study. The test report must identify the sample, state the method and edition used, give the results, include sampling details when known, and record any deviations or unusual events that could affect the outcome.
That helps laboratories document the result in a way that supports audits, technical review and regulatory use.
What terms does FprEN 17775 define?
- iAs - inorganic arsenic, the target species measured by the method.
- analyte - the parameter being determined in the test.
- blank calibration solution - a calibration solution prepared without the analytes, used to check baseline response.
- blank test solution - a solution prepared like the sample solution but without the test portion, used to correct for background.
- calibration solution - a standard solution used to calibrate the instrument and build the calibration curve.
- stock solution - a solution with accurately known analyte concentration, made from pure chemicals.
- test sample solution - the solution obtained after extraction or digestion of the test sample and measured by the instrument.
Who uses FprEN 17775?
FprEN 17775 is used by analytical laboratories, fertilizer manufacturers, quality managers, and compliance teams working with organic and organo-mineral fertilizers. It is also relevant to buyers and regulators who need documented test results for product control.
The method is intended for trained laboratory staff with normal wet-chemistry and instrumental-analysis practice. It is especially useful where product blends need a clear decision on which standard applies.
What changed in FprEN 17775 from the previous edition?
FprEN 17775 will supersede CEN/TS 17775:2022. The foreword lists these significant technical changes:
- the Technical Specification has been adopted as a European Standard
- the scope was updated, including clarification for fertilizing product blends
- normative references for dry matter content determination were added
- normative references for sampling were added
- terms and definitions were revised
- the test report was revised
- the bibliography was revised
- Annex A was revised
- Annex B was added
Which standards are used with FprEN 17775?
| Standard | What it contributes |
|---|---|
| prEN 17773 | Dry matter content needed for expressing results on a dry matter basis |
| prEN 12944-1 | General fertilizer vocabulary used in the definitions section |
| prEN 12944-2 | Fertilizer-specific vocabulary used in the definitions section |
| EN 1482-2 | General sample preparation provisions |
| EN 1482-1 | Recommended sampling methods mentioned in the scope and sampling section |
| EN 1482-3 | Sampling of static heaps mentioned in the sampling section |
| prEN 17768 | Aqua regia digestion for preliminary total arsenic determination |
| prEN 17770 | Total content of specific elements after aqua regia digestion by ICP-AES |
| ISO 5725-2 | Statistical basis for repeatability and reproducibility in the precision section |
What does the FprEN 17775 document contain?
FprEN 17775 contains a complete analytical workflow from extraction to reporting. Clause 8 gives the practical procedure, including sample milling or mixing, extraction in heated water bath, centrifugation, filtration and HPLC-ICP-MS measurement.
It also contains an example instrument setup in Table 1 and precision data in Table 2. Annex A provides example chromatograms for natural and spiked samples, including chloride-interference checks, while Annex B summarizes the inter-laboratory study that supports the method’s precision claims.
Relations
- Effective Date
- 11-Jun-2025
Get Certified
Connect with accredited certification bodies for this standard

Control Union Certifications
Global certification for agriculture and sustainability.

ECOCERT
Organic and sustainability certification.

FSC International
Forest Stewardship Council certification.
Sponsored listings
Frequently Asked Questions
FprEN 17775 is a draft published by the European Committee for Standardization (CEN). Its full title is "Organic and organo-mineral fertilizers - Determination of the inorganic arsenic content". This standard covers: This document specifies a method for extraction, separation, and determination of inorganic arsenic in organic or organo-mineral fertilizers using anion-exchange high performance liquid chromatography (HPLC) or ion chromatography (IC) coupled to ICP-MS. This document is applicable to fertilizing product blends, where a blend is a mix of at least two of the following components: fertilizers, liming materials, soil improvers, growing media, inhibitors, plant biostimulants and where the following category organic fertilizer or organo-mineral fertilizer is the highest % in the blend by mass or volume, or in the case of liquid form by dry mass. If the organic fertilizer or the organo-mineral fertilizer is not the highest % in the blend, the European Standard for the highest % of the blend applies. In case a fertilizing product blend is composed of components in equal quantity, the user decides which standard to apply. NOTE Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.
This document specifies a method for extraction, separation, and determination of inorganic arsenic in organic or organo-mineral fertilizers using anion-exchange high performance liquid chromatography (HPLC) or ion chromatography (IC) coupled to ICP-MS. This document is applicable to fertilizing product blends, where a blend is a mix of at least two of the following components: fertilizers, liming materials, soil improvers, growing media, inhibitors, plant biostimulants and where the following category organic fertilizer or organo-mineral fertilizer is the highest % in the blend by mass or volume, or in the case of liquid form by dry mass. If the organic fertilizer or the organo-mineral fertilizer is not the highest % in the blend, the European Standard for the highest % of the blend applies. In case a fertilizing product blend is composed of components in equal quantity, the user decides which standard to apply. NOTE Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.
FprEN 17775 is classified under the following ICS (International Classification for Standards) categories: 65.080 - Fertilizers. The ICS classification helps identify the subject area and facilitates finding related standards.
FprEN 17775 has the following relationships with other standards: It is inter standard links to CEN/TS 17775:2022. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
FprEN 17775 is associated with the following European legislation: EU Directives/Regulations: 2019/1009; Standardization Mandates: M/564, M/564 Amd 1, M/564 Amd 2. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
FprEN 17775 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 analyte
- 3.2 blank calibration solution
- 3.3 blank test solution
- 3.4 calibration solution
- 3.5 stock solution
- 3.6 test sample solution
- 4 Principle
- 5 Sampling
- 6 Reagents
- 6.1 General
- 6.6 Ammonium carbonate, (NH ) CO , mass fraction w ≥ 99,999 %, for preparation of the mobile
- 6.11 Arsenic (V) standard solution I, with an arsenic (V) mass concentration of 10 mg/l in 2 %
- 7 Apparatus
- 8 Procedure
- 8.1 Sample preparation
- 8.2 Water bath extraction
- 8.3 Preparation of the calibration solutions
- 8.4 Measurement
- 9 Calculation and expression of the results
- 9.1 Integration of peaks
- 9.2 Calculation of inorganic arsenic in the samples
- 10 Precision
- 10.1 Inter-laboratory study
- 10.2 Repeatability
- 10.3 Reproducibility
- 11 Test report
- Annex A
- 1 Inorganic As (V) (m/z 75)
- 2 Cl (m/z 35)
- 2 Cl (m/z 35)
- Annex B
- Bibliography
Introduction
The method is based on a mild acid oxidative extraction of the arsenic species followed by liquid chromatography (high performance liquid chromatography [HPLC] or ion chromatography [IC]) coupled to the element-specific detector ICP-MS (inductively coupled plasma mass spectrometer) for the determination of the mass fraction of inorganic arsenic (iAs). Other standards developed for determination of inorganic arsenic content in plant biostimulants, animal feeding stuffs and foodstuffs were studied and considered as a basis of the described method [2], [3], [4], [5], [6].
The inter-laboratory study reflects the final statistical characteristics of the method for the determination of inorganic arsenic content in organic and organo-mineral fertilizers. The results are given in Annex B (informative).
To prove the compliance with existing limit values for inorganic arsenic in organic and organo-mineral fertilizers, there is the possibility to choose between:
Using a test method determining the total arsenic content, as long as the result of the test shows a content below the limit value for inorganic arsenic. In such a case, it can be safely assumed that the organic fertilizer or the organo-mineral fertilizer complies with the limit value for inorganic arsenic. Using a test method which determines only inorganic arsenic content. A preliminary determination of the total arsenic in aqua regia extracts by ICP-AES (inductively coupled plasma atomic emission spectrometry) according to prEN 17768 [8] and prEN 17770 [9] can reduce the number of the samples where the determination of iAs is necessary because if the content of aqua regia (total) extractable arsenic is lower than the legislative limit for iAs then the determination of iAs is not necessary. In case total As is measured and is presented above or equal the legislative limit for iAs, the content of inorganic As should be determined according to this document. WARNING — Persons using this document should be familiar with usual laboratory practice. This document does not purport to address all of the safety issues, if any, associated with its use. It is the responsibility of the user to establish appropriate health and safety practices and to ensure compliance with any national regulatory conditions.
IMPORTANT — It is absolutely essential that tests conducted according to this document are carried out by suitably trained staff.
oSIST prEN 17775:2026 prEN 17775:2026 (E)
1 Scope
This document specifies a method for extraction, separation, and determination of inorganic arsenic (iAs) in organic or organo-mineral fertilizers using anion-exchange high performance liquid chromatography (HPLC) or ion chromatography (IC) coupled to ICP-MS.
This document is applicable to fertilizing product blends where a blend is a mix of at least two of the following components: fertilizers, liming materials, soil improvers, growing media, inhibitors, plant biostimulants and where the following category organic fertilizer or organo-mineral fertiliser is the highest % in the blend by mass or volume, or in the case of liquid form by dry mass. If the organic fertilizer or the organo-mineral fertilizer is not the highest % in the blend, the European Standard for the highest % of the blend applies. In case a fertilizing product blend is composed of components in equal quantity, the user decides which standard to apply. Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. prEN 17773, Organic and organo-mineral fertilizers — Determination of the dry matter content prEN 12944-1, Fertilizers, liming materials and inhibitors — Vocabulary — Part 1: General terms prEN 12944-2, Fertilizers, liming materials and inhibitors — Vocabulary — Part 2: Terms relating to fertilizers EN 1482-2, Fertilizers, liming materials and inhibitors — Sampling and sample preparation — Part 2:
General sample preparation provisions
3 Terms and definitions
For the purposes of this document, the terms and definitions given in prEN 12944-1 and prEN 12944-2 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https://www.iso.org/obp/
- IEC Electropedia: available at https://www.electropedia.org/
3.1 analyte
parameter to be determined
3.2 blank calibration solution
solution prepared in the same way as the calibration solution but leaving out the analytes
3.3 blank test solution
solution prepared in the same way as the test sample solution but omitting the test portion
oSIST prEN 17775:2026 prEN 17775:2026 (E)
3.4 calibration solution
solution used to calibrate the instrument, prepared from stock solutions by adding acids, buffer, reference element and salts as needed
3.5 stock solution
solution with accurately known analyte concentration(s), prepared from pure chemicals
3.6 test sample solution
solution prepared after extraction or digestion of the test sample according to appropriate specifications
4 Principle
This document specifies a method for the determination of inorganic arsenic in organic or organomineral fertilizers. Inorganic arsenic consists of arsenite As(III) and arsenate As(V). A representative test portion of the sample is treated with a diluted nitric acid and hydrogen peroxide solution in a heated water bath. By this means the sample is solubilised, arsenic species are extracted into solution and As(III) is oxidized to As(V). The inorganic arsenic is selectively separated from other arsenic compounds using anion exchange HPLC (high performance liquid chromatography) coupled online to the element-specific detector ICP-MS (inductively coupled plasma mass spectrometer) for the determination of the mass fraction of the inorganic arsenic. External calibration with solvent matrix-matched standards is used for the quantification of the amount of the inorganic arsenic. Alternatively, IC (ion chromatography) coupled to ICP-MS can be used.
5 Sampling
Sampling is not part of the method specified in this document. Recommended sampling methods are given in EN 1482-1 [11] and in EN 1482-3 [12].
It is important that the laboratory receives a sample that is representative of both the product under consideration and the given analysis. The sample should not have been damaged or changed during transport or storage.
Sample preparation shall be carried out in accordance with EN 1482-2.
6 Reagents
6.1 General
When using a method of high sensitivity like ICP-MS, the control of the blank levels of water, acid and other reagents is very important. The reagents shall be of adequate purity and of recognized analytical grade. The concentration of arsenic species in the reagents and water used shall be negligible and low enough not to affect the results of the determination. Generally, ultra-pure water and nitric acid of minimum p.a. quality is recommended.
6.2 Water, with an electrical conductivity not higher than 0,1 mS/m at 25 °C. 6.3 Nitric acid (HNO ), concentrated, ≥ 65 % (mass fraction), mass concentration of approximately ρ
(HNO ) 1,4 g/ml.
Use only nitric acid available with high purity (minimum p.a. quality) in order to avoid potential contamination.
oSIST prEN 17775:2026 prEN 17775:2026 (E) 6.4 Hydrogen peroxide, H O not less than 30 % (mass fraction). 2 2 High purity is essential to avoid potential contamination. Commercially available hydrogen peroxide for analysis should be tested for contamination of arsenic prior to use. It is necessary to prevent peroxide degradation and ensure the stability of the solution, this is in the discretion of the analyst to use only H O 2 2 of adequate quality.
6.5 Extraction solution, 0,1 mol/l HNO in 3 % (volume fraction) H O . 3 2 2 Add 6,5 ml of HNO (6.3) and thereafter 100 ml of hydrogen peroxide (6.4) into 800 ml water (6.2) in
a 1 000 ml volumetric flask. Fill the flask to the mark with water (6.2). This solution is prepared on the day of use.
It is recommended that the total volume needed for the analysis is estimated and only this amount is produced in the day of use.
6.6 Ammonium carbonate, (NH ) CO , mass fraction w ≥ 99,999 %, for preparation of the mobile
4 2 3 phase solution.
6.7 Aqueous ammonia, (NH (aq)), mass fraction w ≥ 25 %, for adjustment of pH in the mobile phase.
6.8 Methanol, (CH OH), HPLC grade, for preparation of the mobile phase solution.
6.9 Mobile phase, e.g. 50 mmol/l ammonium carbonate in 3 % (volume fraction) methanol at pH 10,3. Dissolve 4,80 g of ammonium carbonate (6.6) in approximately 800 ml water (6.2). Adjust the pH to 10,3 with aqueous ammonia (6.7) and add 30 ml of methanol (6.8) and then fill up to 1 000 ml with water (6.2). Prior to use filter the mobile phase solution through a 0,45 μm filter using a filtering device (7.4). The optimal concentration of ammonium carbonate in the mobile phase depends on the analytical column used (e.g. brand, particle size and dimensions) and should be verified in advance. The appropriate concentration of ammonium carbonate (usually between 10 mmol/l to 50 mmol/l) is highly dependent on the column used and is up to the discretion of the analyst. It should fulfil the criteria for sufficient resolution of the arsenate peak.
Methanol is added to the mobile phase in order to enhance the signal intensity for arsenic. The concentration of methanol to achieve the highest signal to noise ratio depends on the instrument used and should be identified by the analyst.
NOTE 1 Different mobile phase can be also used according to the instructions of the manufacturer of the column but it is necessary to verify the optimal separation conditions.
NOTE 2 For example, Agilent column G3154–65001 with a guard column G3154–65002 and a mobile phase recommended for this column, as a mixture of potassium dihydrogen phosphate (KH2PO4) 2 mmol/l, ethylenediaminetetraacetic acid disodium salt dihydrate (EDTA disodium salt) 0,2 mmol/l, pH 6,0 adjusted with sodium hydroxide (NaOH) 1 mol/l, were successfully used for the analysis. 6.10 Arsenic (V) standard stock solution, with an arsenic (V) mass concentration of 1 000 mg/l. The use of commercial standards of arsenic As(V), with a mass concentration of 1 000 mg/l is recommended.
1 ® Agilent is a registered trademark of Agilent Technologies Inc. This information is given for the convenience of users of this document and does not constitute an endorsement by CEN of the product named.
oSIST prEN 17775:2026 prEN 17775:2026 (E)
6.11 Arsenic (V) standard solution I, with an arsenic (V) mass concentration of 10 mg/l in 2 %
(volume fraction) HNO3.
Pipette 1 ml of arsenic standard stock solution (6.10) into a 100 ml volumetric flask. Add 2 ml of nitric acid (6.3), fill to the mark with water (6.2) and mix well. This solution is stable in a refrigerator at least one week.
...