Shutters, external and internal blinds - Misuse - Test methods

The present standard defines the tests to be carried out to determine the ability of the shutters and blinds to resist abnormal use of the operating mechanism in terms of rough/forced/reversed operation. It applies to the following products: - Internal blinds: Internal venetian, roller, vertical and pleated blinds and darkening blinds; - External blinds: Folding arm awning, trellis arm awning, vertical roller awning, pivot arm awning, marquisolette, façade awning, roof light awning, verandah awning or conservatory awning, dutch awning, insect screen awning, louvre array;...

Äußere und innere Abschlüsse und Markisen - Falschbedienungen - Prüfverfahren

Die vorliegende Norm legt die durchzuführenden Prüfungen fest, um das Verhalten von Abschlüssen bei unsachgemäßer Anwendung der Bedienungsteile durch grobe, gewaltsame oder gegenläufige Bedienung zu untersuchen. Sie gilt für folgende Produkte: - Innere Abschlüsse: Innenjalousie, Rollo, Vertikaljalousie, Faltjalousie und Sonnenblende; - Äußere Abschlüsse: Gelenkarmmarkise, Scherenarmmarkise, Senkrechtmarkise, Fallarmmarkise, Markisolette, Fassadenmarkise, Dachflächenfenstermarkise, Wintergartenmarkise, Korbmarkise, Fliegengitter, feststehende Jalousie; - Abschlüsse: Außenjalousie,...

Fermetures pour baies équipées de fenetres, stores extérieurs et intérieurs - Fausses manoeuvres - Méthodes d'essais

La présente norme définit les essais à réaliser pour caractériser l'aptitude des stores extérieurs et intérieurs et des fermetures à résister à des utilisations anormales des organes de manoeuvre en terme de manoeuvres brutales, forcées ou inversantes. Elle s'applique à l'ensemble des produits suivants: - Les stores intérieurs: Store vénitien d'intérieur, store à enroulement, store à bandes verticales, store plissé, store d'occultation; - les stores extérieurs: store banne, store à projection par pantographe, store vertical guidé, store à projection à l'italienne, marquisolette, store de façade,...

Polkna ter zunanja in notranja senčila - Napačna uporaba - Preskusne metode

General Information

Status
Published
Publication Date
31-Aug-2001
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Sep-2001
Due Date
01-Sep-2001
Completion Date
01-Sep-2001

Overview

EN 12194:2000 (CEN) - "Shutters, external and internal blinds - Misuse - Test methods" specifies standardized test methods to evaluate how shutters, external blinds and internal blinds resist abnormal or improper operation. The standard defines tests that simulate rough, forced and reversed operation of operating mechanisms to determine durability, functional integrity and potential failure modes. EN 12194:2000 was adopted by national bodies (for example, SIST EN 12194:2001).

Key Topics

  • Scope of application: Applies to a broad range of products including internal venetian, roller, vertical, pleated and darkening blinds, and external systems such as folding-arm, trellis-arm, vertical roller, pivot-arm, marquisolette, façade, roof-light, verandah/conservatory, dutch awnings, insect screen awnings and louvre arrays.
  • Misuse scenarios covered: Tests simulate rough handling, forced operation (excessive loads or obstruction) and reversed operation (incorrect sequence or direction) of operating mechanisms.
  • Test objectives: Assess continued functionality, structural integrity, safety risks and evidence of damage after simulated misuse.
  • Test methods: Standardized procedures to reproduce abnormal use conditions consistently so results are comparable across products and laboratories.
  • Assessment criteria: Evaluation focuses on whether mechanisms continue to operate safely, any loss of function, visible damage, and likelihood of unsafe failure under misuse conditions.

Applications

  • Manufacturers and product designers use EN 12194:2000 during design validation and to improve robustness of operating mechanisms for blinds and awnings.
  • Test laboratories apply the standard for type testing, quality control and third‑party verification of misuse resistance.
  • Specifiers, procurement teams and building professionals rely on test results to select products suitable for high‑use or public environments (e.g., commercial buildings, schools).
  • Compliance and certification bodies use these methods as part of conformity assessment where durability under abnormal use is a factor.
  • Installers and maintenance teams benefit from understanding misuse risks highlighted by standardized tests to inform installation practice and user instructions.

Related Standards

  • EN 12194:2000 complements other CEN/ISO standards on doors, windows and building components, and general product safety and durability test methods. For product selection and compliance it is typically used alongside relevant performance, safety and installation standards for blinds and awnings.

Keywords: EN 12194:2000, shutters, external blinds, internal blinds, misuse test methods, blind durability testing, awning testing, CEN standard.

Standard
SIST EN 12194:2001
English language
34 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Äußere und innere Abschlüsse und Markisen - Falschbedienungen - PrüfverfahrenFermetures pour baies équipées de fenetres, stores extérieurs et intérieurs - Fausses manoeuvres - Méthodes d'essaisShutters, external and internal blinds - Misuse - Test methods91.060.50Vrata in oknaDoors and windowsICS:Ta slovenski standard je istoveten z:EN 12194:2000SIST EN 12194:2001en01-september-2001SIST EN 12194:2001SLOVENSKI
STANDARD
SIST E
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Frequently Asked Questions

SIST EN 12194:2001 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Shutters, external and internal blinds - Misuse - Test methods". This standard covers: The present standard defines the tests to be carried out to determine the ability of the shutters and blinds to resist abnormal use of the operating mechanism in terms of rough/forced/reversed operation. It applies to the following products: - Internal blinds: Internal venetian, roller, vertical and pleated blinds and darkening blinds; - External blinds: Folding arm awning, trellis arm awning, vertical roller awning, pivot arm awning, marquisolette, façade awning, roof light awning, verandah awning or conservatory awning, dutch awning, insect screen awning, louvre array;...

The present standard defines the tests to be carried out to determine the ability of the shutters and blinds to resist abnormal use of the operating mechanism in terms of rough/forced/reversed operation. It applies to the following products: - Internal blinds: Internal venetian, roller, vertical and pleated blinds and darkening blinds; - External blinds: Folding arm awning, trellis arm awning, vertical roller awning, pivot arm awning, marquisolette, façade awning, roof light awning, verandah awning or conservatory awning, dutch awning, insect screen awning, louvre array;...

SIST EN 12194:2001 is classified under the following ICS (International Classification for Standards) categories: 91.060.50 - Doors and windows. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 12194:2001 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase SIST EN 12194:2001 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.