Aerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short circuit test

This European Standard specifies a method for appraising the behaviour of cable insulation subjected to an electric arc initiated and maintained by a contaminating fluid.
This European Standard shall be used together with EN 3475-100.
The primary aim of this test is:
-   to produce, in a controlled fashion, continuous failure effects which are representative of those which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination such that electrical arcing occurs between cables;
-   to examine the aptitude of the insulation to track to propagate electric arc to the electrical origin.
Originally defined for 115 Vac network, this test also proposes conditions for 230 Vac network. Unless otherwise specified in product standard, only 115 Vac conditions shall be satisfied.
Six (6) levels of prospective fault current have been specified for concerned cable sizes (see Clause 7). It is generally agreed that larger sizes need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances.
Unless otherwise specified in the technical/product standard sizes 002, 006 and 020 cable shall be assessed.

Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 605: Verhalten nach Kurzschluss, feucht

Diese Europäische Norm legt ein Verfahren zur Beurteilung des Verhaltens der Isolierung einer Leitung gegenüber einem elektrischen Lichtbogen fest, der durch eine Verunreinigungsflüssigkeit erzeugt und aufrechterhalten wird.
Diese Europäische Norm ist in Verbindung mit EN 3475-100 anzuwenden.
Der Hauptzweck dieser Prüfung besteht darin,
- auf geregelte Weise andauernde Fehlereffekte zu erzeugen, die repräsentativ sind für solche, die im Betrieb auftreten können, wenn ein typisches Leitungsbündel beschädigt und einer Verunreinigung durch eine wässrige Flüssigkeit ausgesetzt wird, so dass zwischen den Leitungen Lichtbogen entstehen, und
- zu untersuchen, ob die Isolierung zur Kriechwegbildung neigt, d. h. den Lichtbogen bis zur elektrischen Spannungsquelle auszubreiten.
Diese Prüfung, die ursprünglich für das 115-V-Wechselspannung-Netz festgelegt war, schlägt auch Bedingungen für das 230-V-Wechselspannung-Netz vor. Wenn nicht anders in der Produktnorm festgelegt, sind nur die 115-V-Wechselspannung-Bedingungen einzuhalten.
Sechs (6) voraussichtliche Fehlerstromwerte wurden für die betreffenden Leitungsgrößen (siehe Ab-schnitt 7) festgelegt. Es ist im Allgemeinen vereinbart, dass größere Größen nicht bewertet zu werden brau-chen, da der Kurzschlusseffekt bei niedrigen Leitungsimpedanzen dominierend wird.
Sofern nicht anders in den technischen Normen/Produktnormen festgelegt, sind Leitungen der Größen 002, 006 und 020 zu bewerten.

Série aérospatiale - Câbles électriques à usage aéronautique - Méthodes d'essais - Partie 605 : Essai de court-circuit humide

Aeronavtika - Električni kabli za uporabo v zračnih plovilih - Preskusne metode - 605. del: Mokri preskus kratkega stika

General Information

Status
Published
Publication Date
04-Feb-2018
Technical Committee
I13 - Imaginarni 13
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
23-Jan-2018
Due Date
30-Mar-2018
Completion Date
05-Feb-2018

Relations

Effective Date
17-Jan-2018
Effective Date
09-Jul-2024
Effective Date
04-Feb-2015

Overview

SIST EN 3475-605:2018 is a European Standard developed by CEN, focusing on test methods for aerospace electrical cables used in aircraft. Specifically, this standard describes the Wet Short Circuit Test to evaluate the behavior of cable insulation under conditions where an electrical arc is initiated and sustained by contaminating fluids, typically aqueous solutions. This test method is essential for assessing the durability and safety of electrical cables in environments where moisture or fluid contamination might cause arcing, potentially leading to insulation failure or propagation of faults.

This standard complements EN 3475-100 and is primarily designed for electrical networks operating at 115 Vac, with additional provisions for 230 Vac networks. It covers specific procedures, apparatus, specimen configurations, and acceptance criteria to reliably simulate service conditions.

Key Topics

  • Test Objective: The primary goal is to simulate and control failure phenomena seen in cable bundles damaged and contaminated by fluids, assessing the insulation’s tendency to track and allow electrical arc propagation back to the source.
  • Cable Bundle Preparation: The test requires arranging seven cables in a hexagonal bundle (six around one), with precise spacing and use of glass lacing tape to maintain contact and positioning.
  • Electrical Setup: The test circuit includes adjustable prospective fault currents, three-phase power supplies (115/200 V or 230/400 V at 400 Hz), protective circuit breakers rated per cable size, and critical components such as non-inductive ballast resistors to prevent overvoltage during arc extinction.
  • Electrolyte Application: A defined electrolyte solution (3% sodium chloride in distilled water) is dripped onto the cable bundle at a controlled rate to simulate aqueous contamination and initiate arcing.
  • Test Procedure: Conduct continuous testing with current and fluid flow for 2 hours or until circuit breakers trip, followed by power reapplication without fluid flow to observe fault development. Multiple testing cycles per cable size and current level ensure repeatability and qualification.
  • Damage Assessment: Visual examination includes measuring char length, noting arc tracking effects, and recording any insulation or thermal damage. Detailed documentation is required in test reports, including cable identification, power source characteristics, circuit breaker operations, and damage observations.
  • Scope of Cable Sizes and Fault Currents: Testing typically covers cable sizes 002, 006, and 020, with six defined levels of prospective fault currents appropriate to cable cross-sections to address realistic fault scenarios.

Applications

SIST EN 3475-605:2018 provides invaluable guidance for aerospace manufacturers and testing laboratories to:

  • Verify the insulation integrity and safety of aircraft electrical cables exposed to moisture or fluid contamination.
  • Ensure cable design meets stringent aircraft electrical system safety requirements and resistance to short-circuit and arc tracking failures.
  • Support product qualification, acceptance testing, and certification in compliance with aerospace industry standards.
  • Optimize design and selection of cables for the durability of electrical interconnections in critical aircraft environments where fluid exposure may occur.
  • Facilitate compliance with regulatory and durability mandates across the European aviation sector and beyond.

Related Standards

  • EN 3475-100: General testing requirements and methods for aerospace electrical cables, to be used conjointly with SIST EN 3475-605:2018.
  • EN 2350: Technical specifications for aerospace circuit breakers, providing required trip characteristics for protective devices used in fault current tests.
  • EN 3197: Design and installation guidelines for aircraft electrical and optical interconnection systems, useful for interpreting damage modes such as arc tracking versus short circuit effects.
  • A-A-52083: Specification for glass lacing tape, referenced for cable bundling and securement during testing.

Keywords: SIST EN 3475-605:2018, aerospace cable testing, wet short circuit test, electrical arc insulation, aircraft cable insulation, cable arc tracking, electrical cable qualification, aircraft electrical safety standards, aerospace cable test methods, circuit breaker ratings, cable insulation failure, fluid contamination electrical testing.

Standard

SIST EN 3475-605:2018

English language
11 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 3475-605:2018 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Aerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short circuit test". This standard covers: This European Standard specifies a method for appraising the behaviour of cable insulation subjected to an electric arc initiated and maintained by a contaminating fluid. This European Standard shall be used together with EN 3475-100. The primary aim of this test is: - to produce, in a controlled fashion, continuous failure effects which are representative of those which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination such that electrical arcing occurs between cables; - to examine the aptitude of the insulation to track to propagate electric arc to the electrical origin. Originally defined for 115 Vac network, this test also proposes conditions for 230 Vac network. Unless otherwise specified in product standard, only 115 Vac conditions shall be satisfied. Six (6) levels of prospective fault current have been specified for concerned cable sizes (see Clause 7). It is generally agreed that larger sizes need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances. Unless otherwise specified in the technical/product standard sizes 002, 006 and 020 cable shall be assessed.

This European Standard specifies a method for appraising the behaviour of cable insulation subjected to an electric arc initiated and maintained by a contaminating fluid. This European Standard shall be used together with EN 3475-100. The primary aim of this test is: - to produce, in a controlled fashion, continuous failure effects which are representative of those which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination such that electrical arcing occurs between cables; - to examine the aptitude of the insulation to track to propagate electric arc to the electrical origin. Originally defined for 115 Vac network, this test also proposes conditions for 230 Vac network. Unless otherwise specified in product standard, only 115 Vac conditions shall be satisfied. Six (6) levels of prospective fault current have been specified for concerned cable sizes (see Clause 7). It is generally agreed that larger sizes need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances. Unless otherwise specified in the technical/product standard sizes 002, 006 and 020 cable shall be assessed.

SIST EN 3475-605:2018 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables; 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 3475-605:2018 has the following relationships with other standards: It is inter standard links to SIST EN 3475-605:2010, oSIST prEN 3475-605:2024, SIST EN 3475-605:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 3475-605:2018 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 605: Verhalten nach Kurzschluss, feuchtSérie aérospatiale - Câbles électriques à usage aéronautique - Méthodes d'essais - Partie 605 : Essai de court-circuit humideAerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short circuit test49.060Aerospace electric equipment and systems29.060.20KabliCablesICS:Ta slovenski standard je istoveten z:EN 3475-605:2018SIST EN 3475-605:2018en,fr,de01-marec-2018SIST EN 3475-605:2018SLOVENSKI
STANDARDSIST EN 3475-605:20101DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 3475-605
January
t r s z ICS
v {ä r x r Supersedes EN
u v y wæ x r wã t r s rEnglish Version
Aerospace series æ Cablesá electricalá aircraft use æ Test methods æ Part
x r wã Wet short circuit test Série aérospatiale æ Câbles électriques à usage aéronautique æ Méthodes d 5essais æ Partie
x r w ã Essai de courtæcircuit humide
Luftæ und Raumfahrt æ Elektrische Leitungen für Luftfahrtverwendung æ Prüfverfahren æ Teil
x r wã Verhalten nach Kurzschlussá feucht This European Standard was approved by CEN on
t z August
t r s yä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
t r s z CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
u v y wæ x r wã t r s z ESIST EN 3475-605:2018

EN 2350, Aerospace series — Circuit breakers — Technical specification EN 3197, Aerospace series — Design and installation of aircraft electrical and optical interconnection systems EN 3475-100, Aerospace series — Cables, electrical, aircraft use — Test methods — Part 100: General A-A-52083, Tape, lacing and tying, glass 1) 3 Specimen requirements Cables to be tested shall be of traceable origin and shall have passed the high voltage dielectric test defined in the product standard. 4 Preparation of specimen 4.1 Cut seven (7) separate lengths of approximately 0,5 m consecutively from one (1) length of cable, and strip one of the ends of insulation to permit electrical connection. Clean each length of cable with a clean cloth moistened with propan-2-ol (isopropyl alcohol) fluid.
1) Published by: Department of Defense Industrial Supply Center, ATTN: DISC-BBEE, 700 Robbins Avenue, Philadelphia, PA 19111-5096 – USA. SIST EN 3475-605:2018

Key 1 Drop needle A1-A2 : Phase A B1-B2 : Phase B C1-C2 : Phase C N : Neutral cable connected to earth Figure 1 — Specimen configuration
Key 1 Lancing tape 2 Drop needle 3 Drops 4 10 mm to 20 mm 5 Ends of the 7 cables in the same plane Figure 2 — Test configuration 5 Apparatus 5.1 Electrical equipment Connect the seven (7) cables of the test sample within a circuit as shown in Figure 3. This circuit shall have the following requirements: a) The provision of adjustable levels of prospective fault currents for the six (6) A, B and C
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...