Abstract

This document specifies a test method for the qualification and quantification of organotin compounds. This test method is applicable to all types of materials of textile products.
NOTE CEN/TR 16741 defines which materials are applicable to this determination.

Status
Not Published
Public Enquiry End Date
30-Dec-2026
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
03-Nov-2026
Due Date
23-Mar-2027

Buy Documents

Draft

oSIST prEN ISO 22744-1:2026

English language (20 pages)
Preview
Preview
e-Library read for
×1 day

oSIST prEN ISO 22744-1:2026 is the Slovenian adoption of ISO/DIS 22744-1:2026, prepared by ISO and published through SIST for textile testing. It specifies a laboratory method for the qualification and quantification of organotin compounds in textile fibres, yarns, fabrics, coated fabrics, printed fabrics, plastic parts and rubber parts of textile products. The method uses gas chromatography with mass spectrometry, including GC-MS and GC-MS/MS, and is aimed at analytical laboratories, quality teams, and buyers checking restricted substances in textile materials.

What does oSIST prEN ISO 22744-1:2026 specify?

oSIST prEN ISO 22744-1:2026 specifies a test method for organotin compounds in textile-related materials, using derivatisation followed by gas chromatography with mass spectrometric detection. The scope covers both qualification and quantification, so the method is intended to identify which organotin compounds are present and measure them.

The document applies to textile fibres, yarns, fabrics, coated fabrics, printed fabrics, plastic parts and rubber parts of textile products. It includes a safety warning that the work may involve hazardous materials, operations and equipment.

The document is organized into Clauses 1 to 10, followed by two informative annexes. Clause 1 gives the scope, Clause 2 gives the normative references, Clause 4 explains the analytical principle, Clauses 5 to 8 cover reagents, apparatus, sample preparation and procedure, and Clauses 9 and 10 cover calculation and the test report.

AnnexWhat it covers
Annex AExample instrumental conditions for organotin analysis, including GC conditions, GC-MS ion groups, and GC-MS/MS transitions
Annex BReliability of the method from interlaboratory testing

What are the key requirements of oSIST prEN ISO 22744-1:2026?

The main requirement is to follow the extraction, derivatisation and GC-based measurement workflow exactly enough to produce comparable results. In practice, the method is built around a defined sequence of sample preparation, calibration, instrumental analysis and result calculation.

Analytical principle and target compounds

Clause 4 states that the sample is cut into small pieces, extracted with a methanol/ethanol mixture containing tropolone, derivatised with sodium tetraethylborate, and then analysed by GC-MS or GC-MS/MS. This matters because the organotin compounds are converted into volatile derivatives before measurement, which is what makes gas chromatographic analysis possible.

Clause 4 and Table 1 define the target compounds that can be analysed, grouped as mono-substituted, di-substituted, tri-substituted and tetra-substituted organotin compounds. The document also states that further organotin compounds can be analysed if the method is validated for them. For a laboratory, this means the method is not limited to the listed compounds, but any extension has to be justified by validation.

Clause 4 also notes two special cases. Bis(tri-n-butyltin)oxide is detected as tri-n-butyltin, and mono-, di- and triethyltin chloride are converted to tetraethyltin during derivatisation. If tetraethyltin findings must be confirmed, the specimen is reprocessed without adding sodium tetraethylborate. That matters when a reported tetraethyltin result needs confirmation rather than only routine screening.

Reagents, standards and apparatus

Clause 5 requires analytical-grade reagents and certified reference standards where applicable. It names sodium tetraethylborate, tetrahydrofuran, methanol, tropolone, sodium acetate, water, glacial acetic acid, ethanol and n-hexane, together with four internal standards matched to the substitution level of the analyte. This matters because the method depends on controlled derivatisation and on internal-standard correction for reliable quantification.

Clause 5.5 allows alternative internal standards if recovery is low. In practice, that gives laboratories a way to deal with matrix effects when the listed internal standards do not recover well.

Clause 6 lists the required equipment, including an analytical balance with 0.1 mg resolution, volumetric glassware, pH meter, micropipettes, a horizontal mechanical shaker, ultrasonic bath, centrifuge, GC vials, and a GC with either a single quadrupole MS or a triple quadrupole MS/MS. This means the method is designed for a standard analytical laboratory, but it does require specific chromatographic and mass spectrometric capability.

Sample preparation and calibration

Clause 7 requires the test specimen to be a single material type, such as textile, coated textile, polymer or rubber. If the sample has different components, it is dismantled first, and the material is cut into pieces of about 0.3 cm to 0.5 cm. Up to three equal-mass specimens of the same material type may be tested together, provided the limit value and quantification limits are taken into account.

Clause 8.6 requires at least five calibration solutions at suitable concentrations, prepared with internal standard, buffer and tropolone before derivatisation. This is important because the method now uses a calibration curve for quantification rather than a detector response factor approach.

Measurement and calculation

Clause 8.9 allows determination by GC-MS or GC-MS/MS. For GC-MS, three diagnostic ion groups are used, with one for quantification and two for qualification. For GC-MS/MS, the method uses Multiple Reaction Monitoring (MRM). In both cases, the analyte is quantified against an internal standard with the same degree of substitution.

Clause 9.1 and 9.2 describe calibration and calculation from the calibration graph. The result for each identified organotin cation is expressed as a mass fraction in mg/kg, calculated from the interpolated concentration, the hexane aliquot volume and the specimen mass. For the user, this means the final reported value is traceable to the calibration curve and the weighed sample mass.

Clause 9.3 states that the method can reach a detection limit of 0.05 mg/kg and a quantification limit of 0.2 mg/kg. Clause 9.4 refers users to Annex B for method reliability. Clause 10 requires the report to include the document reference, sample identification, results for each quantified organotin compound, deviations, unusual features and the date of testing.

Who uses oSIST prEN ISO 22744-1:2026?

oSIST prEN ISO 22744-1:2026 is used by textile testing laboratories, quality control teams, compliance specialists, and laboratories working for brands or suppliers. It is relevant for textile products and also for plastic and rubber parts that are part of textile products.

In practice, users apply it for restricted-substance screening, supplier verification, incoming inspection, dispute testing, and documentation of organotin results in textiles and textile components. It is also useful where buyers or brands maintain restricted substances lists and need analytical evidence from a recognized test method.

What changed in oSIST prEN ISO 22744-1:2026 from the previous edition?

oSIST prEN ISO 22744-1:2026 cancels and replaces ISO 22744-1:2020 and is described as technically revised. The stated changes include:

  • the scope was expanded to explicitly cover textile fibres, yarns, fabrics, coated fabrics, printed fabrics, plastics and rubber parts of textile products
  • Clause 4 was revised to include both GC-MS and GC-MS/MS and to describe the analytical procedure more clearly
  • Table 1 received a footnote on verifying tetraethyltin in a test sample
  • Clause 5 was restructured and sodium acetate trihydrate was added
  • Clause 6 was revised to include triple quadrupole mass spectrometers and additional equipment
  • Clause 7 was revised and clarified
  • the stock solution concentration in Clause 8.3.2 was increased
  • Clause 8.3.4 now lets laboratories decide which target compounds to include in the stock solution
  • Clause 8.9 was split into three subclauses
  • Clause 8.9.1 adds a confirmation procedure for tetraethyltin findings
  • Clause 8.9.3 on GC-MS/MS determination was added
  • Clause 9.1 on calibration was added
  • the former calculation clauses were revised to use calibration-curve-based quantification instead of the detector response factor approach
  • Clause 9.4 on reliability was added
  • Clause 10 was rephrased
  • Annex A was restructured, and a new example for triple quadrupole conditions was added
  • bibliography references cited in the clauses were added

Which standards are used with oSIST prEN ISO 22744-1:2026?

oSIST prEN ISO 22744-1:2026 cites two normative references:

  • ISO 3696, which supplies the water quality requirement used for analytical laboratory work
  • ISO 4787, which covers volumetric instruments and their testing and use, supporting the glassware and volume measurements in the method

These references matter because the method depends on controlled water quality and accurate volumetric operations for standard solutions, buffers and extracts.

What does the oSIST prEN ISO 22744-1:2026 document contain?

The document contains the full analytical workflow for organotin determination in textile-related materials. It gives the principle of extraction and derivatisation, the reagent list, the apparatus list, sample preparation instructions, calibration preparation, extraction and hexane transfer steps, and the calculation approach for organotin cations.

It also contains tables for target compounds, internal standards and weighting factors, plus formula-based conversions between organotin chloride forms and organotin cation concentrations. For measurement setup, Annex A gives example GC conditions, diagnostic ions for GC-MS, and transitions for GC-MS/MS. For method performance, Annex B gives interlaboratory reliability data.

Relations

Effective Date
26-Nov-2025

Buy Documents

Draft

oSIST prEN ISO 22744-1:2026

English language (20 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

Control Union Certifications

Global certification for agriculture and sustainability.

RVA Netherlands Verified

ECOCERT

Organic and sustainability certification.

COFRAC France Verified

Hohenstein Institut

Textile testing and certification.

DAKKS Germany Verified

Sponsored listings

Frequently Asked Questions

oSIST prEN ISO 22744-1:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Textiles and textile products - Determination of organotin compounds - Part 1: Derivatisation method using gas chromatography (ISO/DIS 22744-1:2026)". This standard covers: This document specifies a test method for the qualification and quantification of organotin compounds. This test method is applicable to all types of materials of textile products. NOTE CEN/TR 16741 defines which materials are applicable to this determination.

This document specifies a test method for the qualification and quantification of organotin compounds. This test method is applicable to all types of materials of textile products. NOTE CEN/TR 16741 defines which materials are applicable to this determination.

oSIST prEN ISO 22744-1:2026 is classified under the following ICS (International Classification for Standards) categories: 59.080.01 - Textiles in general; 71.040.50 - Physicochemical methods of analysis. The ICS classification helps identify the subject area and facilitates finding related standards.

oSIST prEN ISO 22744-1:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 22744-1:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

oSIST prEN ISO 22744-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Principle
  • 5 Reagents
  • 5.5 Internal standards (IS)
  • 5.8 Sodium acetate
  • 6 Apparatus and materials
  • 7 Preparation of the test sample
  • 8 Procedure
  • 8.1 General
  • 8.2 Preparation of the sodium tetraethylborate solution
  • 8.3 Preparation of standard solutions
  • 8.4 Preparation of the tropolone solution (5 g/l solution of tropolone)
  • 8.5 Preparation of the buffer solution (pH = 4,5)
  • 8.6 Preparation of the calibration solutions
  • 8.7 Preparation of the extract of the test specimen
  • 8.8 Preparation of the blank solution
  • 8.9 Determination with gas chromatography
  • 9 Expression of results
  • 9.1 Calibration
  • 9.2 Calculation of the results of individual organotin cations
  • 9.3 Detection limit and quantification limit
  • 9.4 Reliability of the test method
  • 10 Test report
  • Annex A
  • Annex B
  • Bibliography

Introduction

Certain organotin compounds have been identified as toxic, reproduction toxic and endocrine disruptors. Thus, several countries have restricted them in articles such as textile products, e.g. in the European Union [1] [2] by COMMISSION REGULATION (EU) No 276/2010 amending REGULATION (EC) No 1907/2006 . Further organotin compounds are restricted by textile brands in their restricted substances lists (RSL) often at lower limits than the legal thresholds in the EU.

oSIST prEN ISO 22744-1:2026 DRAFT International Standard ISO/DIS 22744-1:2026(en) Textiles and textile products — Determination of organotin compounds — Part 1:

Derivatisation method using gas chromatography

1 Scope

This document specifies a test method for the qualification and quantification of organotin compounds by applying gas chromatography coupled with mass spectrometry. It is applicable to textile fibres, yarns, fabrics, coated fabrics, printed fabrics, plastic, and rubber parts of textile products. WARNING — The use of this document can involve hazardous materials, operations and equipment. It does not purport to address all of the safety or environmental problems associated with its use.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3696, Water for analytical laboratory use — Specification and test methods ISO 4787, Laboratory glass and plastic ware — Volumetric instruments — Methods for testing of capacity and for use

3 Terms and definitions

No terms and definitions are listed in this document.

ISO and IEC maintain terminological databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at http:// www .electropedia .org/

4 Principle

The sample is cut into small pieces and extracted with a methanol/ethanol mixture containing tropolone as a complexing agent, in a sealed vial at 60 °C, in an ultrasonic bath. The polar and high-boiling organotin compounds in the extract are then converted to the corresponding volatile alkyl derivatives, by reaction with sodium tetraethylborate, NaB(Et) . The volatile organo tin alkyl derivates are qualified and quantified

by using a gas chromatograph coupled to a single quadrupole mass spectrometer (GC-MS) or a gas chromatograph coupled to a triple quadrupole mass spectrometer (GC-MS/MS)]. Table 1 indicates the list of target compounds which can be analysed with the method specified in this document. This document is also applicable for further organotin compounds provided that the method is validated with the additional compounds.

oSIST prEN ISO 22744-1:2026 ISO/DIS 22744-1:2026(en) Table 1 — List of target compounds that can be analysed and internal standards CAS Registry a Number® Type of target compound Target compound (CAS RN®) Internal standard: n-Heptyltin trichloride 59344–47–7 Methyltin trichloride 993–16–8 Mono-substituted n-Butyltin trichloride 1118–46–3 n-Octyltin trichloride 3091–25–6 Phenyltin trichloride 1124–19–2 Internal standard: Di-n-heptyltin dichloride 74340–12–8 Dimethyltin dichloride 753–73–1 Di-n-propyltin dichloride 867–36–7 Disubstituted Di-n-butyltin dichloride 683–18–1 Di-n-octyltin dichloride 3542–36–7 Diphenyltin dichloride 1135–99–5 Internal standard: Tri-n-pentyltin chloride 3342–67–4 Trimethyltin chloride 1066–45–1 Tri-n-propyltin chloride 2279–76–7 b Trisubstituted Tri-n-butyltin chloride 1461–22–9 Tri-n-octyltin chloride 2587–76–0 Triphenyltin chloride 639–58–7 Tricyclohexyltin chloride 3091–32–5 Internal standard: Tetra-n-propyltin 2176–98–9

Tetrasubstituted Tetraethyltin 597–64–8 Tetra-n-butyltin 1461–25–2 a CAS Registry Number® (CAS RN®) is a trademark of the American Chemical Society (ACS). This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the product named. b If bis(tri-n-butyltin)oxide (TBTO), CAS RN® 56–35–9, is present, it is detected as tri-n-butyltin.

If mono-, di-, and triethyltinchloride are present in a test specimen they are converted to tetraethyltin by sodium tetraethylborate. If requiered by the test order, findings of tetraethyltin shall be confirmed by reprocessing the test specimen (8.7) without performing 8.7.8 (i.e. without adding sodium tetraethylborate).

5 Reagents

Unless otherwise specified, use only reagents of recognized analytical grade and certified reference standards.

5.1 Sodium tetraethylborate, CAS RN®: 15523-24-7.

5.2 Tetrahydrofuran (THF), stabilized, CAS RN®: 109-99-9.

5.3 Inert gas, e.g. nitrogen or argon.

5.4 Organotin compounds, listed in Table 1.

5.5 Internal standards (IS)

5.5.1 n-Heptyltin trichloride, CAS RN®: 59344-47-7.

IS for monostubstituted organotin compounds.

oSIST prEN ISO 22744-1:2026 ISO/DIS 22744-1:2026(en) 5.5.2 Di-n-heptyltin dichloride, CAS RN®: 74340-12-8.

IS for distubstituted organotin compounds.

5.5.3 Tri-n-pentyltin chloride, CAS RN®: 3342-67-4.

IS for tristubstituted organotin compounds.

5.5.4 Tetra-n-propyltin, CAS RN®: 2176-98-9.

IS for tetrastubstituted organotin compounds.

5.5.5 Alternative internal standards

If the recovery rate of an internal standard (5.5.1, 5.5.2, 5.5.3 and 5.5.4) is low, alternative internal standards may be used (for example deuterated compounds) (see also 9.1). 5.6 Methanol, of analytical grade, CAS RN®: 67-56-1.

5.7 Tropolone (2-hydroxy-2,4,6-cycloheptatrien-1-one), CAS RN®: 533-75-5.

5.8 Sodium acetate

5.8.1 Sodium acetate, CAS RN®: 127-09-3.

5.8.2 Sodium acetate trihydrate, CAS RN®: 6131-90-4.

5.9 Water, grade 3 in accordance with ISO 3696.

5.10 Glacial acetic acid, CAS RN®: 64-19-7.

5.11 Ethanol, technical grade or industrial methylated spirit (IMS), CAS RN®: 64-17-5. 5.12 n-hexane, CAS RN®: 110-54-3.

6 Apparatus and materials

The usual equipment and laboratory glassware, according to ISO 4787, shall be used, in addition to the following.

6.1 Analytical balance, with a resolution of minimum 0,1 mg.

6.2 Volumetric flasks, of required volumes.

6.3 Pipettes, of required volumes.

6.4 Glass vessel, with screw caps and a volume of, for example, 50 ml. 6.5 Calibrated pH-meter, with a glass combination electrode and pH range of 0 to 14. 6.6 Micropipettes, of required volumes.

6.7 Horizontal mechanical shaker.

oSIST prEN ISO 22744-1:2026 ISO/DIS 22744-1:2026(en) −1 NOTE Horizontal shaker with minimum frequency of 5 s , path length 2 cm to 5 cm has been found suitable. 6.8 Ultrasonic bath, with adjustable temperature suitable for operation at about 60 °C. 6.9 Centrifuge.

6.10 GC vial with PTFE cap, for example 2 ml.

6.11 Gas chromatograph (GC) with a single quadrupole mass spectrometer (MS) or a triple quadrupole mass spectrometer (MS/MS).

7 Preparation of the test sample

Dismantle the test sample if it consists of different components. The test specimen shall consist of a single material type (textile, coated textile, polymer, rubber etc.). Cut the test specimen into pieces of about 0,3 cm to 0,5 cm edge length.

Up to three test specimens (of equal mass) of the same material type may be tested together, taking into consideration the limit value to be complied with and the limits of quantification.

8 Procedure

8.1 General

WARNING — Sodium tetraethylborate is air-sensitive and can spontaneously combust in the presence of air. The sodium tetraethylborate solution should be prepared (8.2) and worked with (8.6.5, 8.7.8) in a high-volume fume hood without the presence of flammable substances or under inert gas atmosphere (5.3).

WARNING — Organotin compounds (Table 1) are toxic, reproduction toxic and known endocrine disrupters; therefore, they should be treated with utmost care. All the chemicals that are stored below room temperature should be allowed to reach room temperature before an aliquot is taken.

8.2 Preparation of the sodium tetraethylborate solution

Weigh about 2 g of sodium tetraethylborate (5.1) into a 10 ml volumetric flask (6.2) and make up to volume with tetrahydrofuran (5.2).

This solution is stable for about three months if stored under an inert gas blanket (5.3). NOTE Pre-weighed tetraethylborate or solutions are commercially available.

8.3 Preparation of standard solutions

8.3.1 General

The organotin compounds are commercially available as chlorides (Table 1), but the mass concentration for the calibration curve and the result are expressed in mg/kg of organotin cations. 2+ EXAMPLE 1 With di-n-butyltin dichloride, n-Bu SnCl (di-n-butyltin dichloride) is the chloride form and Bu Sn is 2 2 2 the cation form.

Table 2 gives the amount of organotin chloride and the weighting factor for recalculation of organotin cations (for 100 % purity of the chloride form).

...