Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes

This part of IEC 60432 specifies the safety and the related interchangeability requirements of tungsten halogen lamps for general lighting service. It covers those tungsten halogen lamps that are used as direct replacements for conventional tungsten filament lamps as well as new tungsten halogen lamps which have no correspondence in IEC 60432-1, but for which the safety and interchangeability requirements are treated by this standard in conjunction with IEC 60432-1. These tungsten halogen lamps have the following characteristics:
– rated wattage up to and including 250 W;
– rated voltage of 50 V to 250 V inclusive;
– caps B15d, B22d, E12, E14, E17, E26, E26d, E26/5039, E27 or E27/5139.
This standard also covers single-ended lamps, within the above ratings, which are not direct
replacements for conventional tungsten filament lamps, but serve the same purpose.
NOTE 1 There is no implication that a tungsten halogen lamp used as a substitute for an incandescent tungsten filament lamp would use the same bulb shape as the original incandescent lamp. NOTE 2 There are two variations of E26 caps which are not fully compatible. E26/24 caps are used in North merica and E26/25 caps are used in Japan.

Glühlampen - Sicherheitsanforderungen - Teil 2: Halogen-Glühlampen für den Hausgebrauch und ähnliche allgemeine Beleuchtungszwecke

Lampes à incandescence - Prescriptions de sécurité - Partie 2: Lampes tungstène-halogène pour usage domestique et éclairage général similaire

Sijalke - Varnostne specifikacije - 2. del: Halogenske sijalke za uporabo v stanovanjih in podobnih primerih splošne razsvetljave

Ta del standarda IEC 60432 določa zahteve glede varnosti in s tem povezane zamenljivosti halogenskih sijalk za splošno uporabo v razsvetljavi. Zajema halogenske sijalke,
ki se uporabljajo kot neposredna zamenjava za konvencionalne sijalke, in nove halogenske sijalke, ki niso obravnavane v standardu IEC 60432-1, ampak so zahteve glede njihove varnosti in zamenljivosti obravnavane v tem standardu in standardu IEC 60432-1. Te halogenske sijalke imajo naslednje značilnosti:
– nazivno moč do vključno 250 W;
– nazivno napetost od 50 V do vključno 250 V;
– vznožke B15d, B22d, E12, E14, E17, E26, E26d, E26/50x39, E27 ali E27/51x39.
Ta standard zajema tudi sijalke z enojno vijačnico v okviru zgoraj navedenih moči, ki niso neposredna
zamenjava za konvencionalne sijalke, ampak se uporabljajo za enak namen.
OPOMBA 1: Ni navedeno, da bi halogenska sijalka, ki se uporabi kot zamenjava za sijalko brez zgorevanja, imela enako obliko bučke kot izvirna sijalka brez zgorevanja. OPOMBA 2: Obstajata dve različici vznožka E26, ki nista povsem združljivi. Vznožki E26/24 se uporabljajo v Severni Ameriki, vznožki E26/25 pa na Japonskem.

General Information

Status
Published
Publication Date
07-Aug-2012
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
12-Jul-2012
Due Date
16-Sep-2012
Completion Date
08-Aug-2012

Relations

Effective Date
17-May-2011

Overview

SIST EN 60432-2:2000/A2:2012 is a European standard developed by CLC (European Committee for Electrotechnical Standardization) that specifies safety requirements for tungsten halogen incandescent lamps intended for domestic and similar general lighting purposes. This standard is an amendment to the original EN 60432-2:2000 and aligns with the international IEC 60432-2:1999/A2:2012 publication.

The standard ensures that tungsten halogen lamps used in household and comparable environments meet rigorous electrical safety and photobiological safety specifications, addressing potential hazards associated with these lighting devices under certain voltage limits. It includes updates reflecting the latest understanding of lamp safety concerning optical radiation, particularly blue light and ultraviolet exposure.

Key Topics

  • Scope: Focus on tungsten halogen incandescent lamps designed for domestic and general lighting usage.
  • Safety Requirements: Addresses electrical safety parameters conforming to the Low Voltage Directive (LVD 2006/95/EC) ensuring safe design and operation.
  • Photobiological Safety:
    • Incorporates guidelines from IEC 62471:2006 and IEC/TR 62471-2.
    • Confirms lamps under this standard do not reach blue light hazard or infrared radiation risks necessitating risk group classification.
    • Photobiological hazards such as UV radiation are addressed, with protection measures specified for manufacturers.
  • Water Contact Protection: Enhancements for safeguarding lamps against potential water exposure during use.
  • Normative References: Critical additions to existing references related to photobiological safety and manufacturing recommendations for non-laser optical radiation.
  • National Implementation: Amendments require adoption at a national level in all CENELEC member countries without alterations to harmonize market safety standards.

Applications

This standard is essential for manufacturers, importers, and testing bodies involved with:

  • Tungsten halogen lamps used in residential lighting fixtures.
  • General lighting products for environments similar to households such as offices, commercial spaces, and public areas.
  • Ensuring compliance for product safety certification required under European legislation.
  • Designing lamps that offer safe illumination without posing risks from electrical faults or optical radiation exposure.
  • Providing guidance for product labeling and documentation regarding photobiological risk classifications.
  • Facilitating harmonized product standards across the European market to improve consumer safety and market access.

Related Standards

  • IEC 60432-2:1999/A2:2012: International counterpart standard for tungsten halogen lamp safety.
  • IEC 62471:2006 – Photobiological safety of lamps and lamp systems: Defines risk groups for optical radiation exposure.
  • IEC/TR 62471-2: Guidance on manufacturing requirements related to non-laser optical radiation safety.
  • Low Voltage Directive 2006/95/EC (LVD): European directive covering electrical equipment safety used within certain voltage limits.
  • EN 60432-1: Safety specifications for incandescent lamps, Part 1 covers non-halogen incandescent lamps which complements Part 2.

This standard enhances product safety, regulatory compliance, and consumer protection for tungsten halogen lamps used in everyday lighting, making it a crucial reference for stakeholders in the lighting industry and standardization bodies focused on electrotechnical products.

Amendment

SIST EN 60432-2:2000/A2:2012

English language
6 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 60432-2:2000/A2:2012 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes". This standard covers: This part of IEC 60432 specifies the safety and the related interchangeability requirements of tungsten halogen lamps for general lighting service. It covers those tungsten halogen lamps that are used as direct replacements for conventional tungsten filament lamps as well as new tungsten halogen lamps which have no correspondence in IEC 60432-1, but for which the safety and interchangeability requirements are treated by this standard in conjunction with IEC 60432-1. These tungsten halogen lamps have the following characteristics: – rated wattage up to and including 250 W; – rated voltage of 50 V to 250 V inclusive; – caps B15d, B22d, E12, E14, E17, E26, E26d, E26/5039, E27 or E27/5139. This standard also covers single-ended lamps, within the above ratings, which are not direct replacements for conventional tungsten filament lamps, but serve the same purpose. NOTE 1 There is no implication that a tungsten halogen lamp used as a substitute for an incandescent tungsten filament lamp would use the same bulb shape as the original incandescent lamp. NOTE 2 There are two variations of E26 caps which are not fully compatible. E26/24 caps are used in North merica and E26/25 caps are used in Japan.

This part of IEC 60432 specifies the safety and the related interchangeability requirements of tungsten halogen lamps for general lighting service. It covers those tungsten halogen lamps that are used as direct replacements for conventional tungsten filament lamps as well as new tungsten halogen lamps which have no correspondence in IEC 60432-1, but for which the safety and interchangeability requirements are treated by this standard in conjunction with IEC 60432-1. These tungsten halogen lamps have the following characteristics: – rated wattage up to and including 250 W; – rated voltage of 50 V to 250 V inclusive; – caps B15d, B22d, E12, E14, E17, E26, E26d, E26/5039, E27 or E27/5139. This standard also covers single-ended lamps, within the above ratings, which are not direct replacements for conventional tungsten filament lamps, but serve the same purpose. NOTE 1 There is no implication that a tungsten halogen lamp used as a substitute for an incandescent tungsten filament lamp would use the same bulb shape as the original incandescent lamp. NOTE 2 There are two variations of E26 caps which are not fully compatible. E26/24 caps are used in North merica and E26/25 caps are used in Japan.

SIST EN 60432-2:2000/A2:2012 is classified under the following ICS (International Classification for Standards) categories: 29.140.20 - Incandescent lamps. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 60432-2:2000/A2:2012 has the following relationships with other standards: It is inter standard links to SIST EN 60432-2:2000. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 60432-2:2000/A2:2012 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 60432-2:2000/A2:2012 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2012
Sijalke - Varnostne specifikacije - 2. del: Halogenske sijalke za uporabo v
stanovanjih in podobnih primerih splošne razsvetljave
Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for
domestic and similar general lighting purposes
Glühlampen - Sicherheitsanforderungen - Teil 2: Halogen-Glühlampen für den
Hausgebrauch und ähnliche allgemeine Beleuchtungszwecke
Lampes à incandescence - Prescriptions de sécurité - Partie 2: Lampes tungstène-
halogène pour usage domestique et éclairage général similaire
Ta slovenski standard je istoveten z: EN 60432-2:2000/A2:2012
ICS:
29.140.20 Žarnice z žarilno nitko Incandescent lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 60432-2/A2
NORME EUROPÉENNE
June 2012
EUROPÄISCHE NORM
ICS 29.140.20
English version
Incandescent lamps -
Safety specifications -
Part 2: Tungsten halogen lamps for domestic
and similar general lighting purposes
(IEC 60432-2:1999/A2:2012)
Lampes à incandescence -  Glühlampen -
Prescriptions de sécurité - Sicherheitsanforderungen -
Partie 2: Lampes tungstène-halogène Teil 2: Halogen-Glühlampen für den
pour usage domestique et éclairage Hausgebrauch und ähnliche allgemeine
général similaire Beleuchtungszwecke
(CEI 60432-2:1999/A2:2012) (IEC 60432-2:1999/A2:2012)

This amendment A2 modifies the European Standard EN 60432-2:2000; it was approved by CENELEC on 2012-
04-26. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate
the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60432-2:2000/A2:2012 E

Foreword
The text of document 34A/1533/FDIS, future amendment 2 to edition 2 of IEC 60432-2, prepared by
SC 34A “Lamps”, of IEC/TC 34, “lamps and related equipment” was submitted to the IEC-CENELEC
parallel vote and approved by CENELEC as EN 60432-2:2000/A2:2012.
The following dates are fixed:
(dop) 2013-01-26
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2015-04-26
• latest date by which the national
standards conflicting with the
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment
Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC).
Endorsement notice
The text of the International Standard IEC 60432-2:1999/A2:2012 was approved
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...