ISO 3299:1994
(Main)Photography - Processing chemicals - Specifications for 1-phenyl-3-pyrazolidinone
Photography - Processing chemicals - Specifications for 1-phenyl-3-pyrazolidinone
Cancels and replaces the first edition (1976). Establishes criteria for the purity of photographic-grade 1-phenyl-3-pyrazolidinone (phenidone) and specifies the test methods to be used to determine the purity.
Photographie — Produits chimiques de traitement — Spécifications pour la phényl-1 pyrazolidinone-3
General Information
- Status
- Published
- Publication Date
- 02-Nov-1994
- Technical Committee
- ISO/TC 42 - Photography
- Drafting Committee
- ISO/TC 42 - Photography
- Current Stage
- 9093 - International Standard confirmed
- Start Date
- 04-Nov-2021
- Completion Date
- 13-Dec-2025
Relations
- Effective Date
- 15-Apr-2008
Overview
ISO 3299:1994 is an International Standard issued by the International Organization for Standardization (ISO) that specifies the purity requirements and test methods for photographic-grade 1-phenyl-3-pyrazolidinone, commonly known as phenidone. This second edition replaces the original 1976 version and sets stringent criteria to ensure the chemical’s suitability in photographic processing. The standard is essential for manufacturers, laboratories, and quality control professionals involved in producing or using photographic processing chemicals.
The document outlines detailed physical and chemical specifications, safety considerations, and established test procedures to verify the purity and identity of phenidone. It ensures consistency and prevents undesirable photographic effects caused by impurities in the chemical.
Key Topics
- Purity Criteria: ISO 3299:1994 mandates a minimum assay content of 98.5% by mass for phenidone, ensuring high-grade chemical quality.
- Physical Properties: Phenidone appears as a pale cream to white powder, free from aggregates or large crystals, with a melting point between 119°C and 122°C.
- Test Methods: The standard prescribes classical analytical techniques and instrumental methods such as titration, infrared spectroscopy, and ignition residue tests to assess:
- Assay content
- Identity verification (melting point and infrared spectrum)
- Residue after ignition (maximum 0.10% by mass)
- Heavy metals content, especially lead (max 0.002%) and iron (max 0.005%)
- Volatile matter content (max 0.10%)
- Solubility in alkaline sulfite solution and insoluble matter in chloroform (optional)
- Safety & Handling: The document stresses the importance of safe laboratory practices when handling chemicals, including the use of protective apparel and awareness of hazardous substances used in testing.
- Storage Recommendations: Phenidone must be stored in a closed container at room temperature to maintain stability and purity.
Applications
ISO 3299:1994 is crucial for various stakeholders within photographic industries and chemical manufacturing, including:
- Manufacturers of photographic chemicals: Ensuring their phenidone meets internationally recognized purity standards for optimal processing performance.
- Quality control laboratories: Implementing standardized test methods to verify chemical purity and identify contaminants that could affect photographic development.
- Photographic processing facilities: Utilizing phenidone that complies with these purity criteria to produce high-quality photographic images while minimizing processing defects.
- Suppliers and distributors: Providing chemical products that fulfill ISO specifications to meet customer expectations globally.
By adhering to this standard, organizations reduce variability and improve reliability in photographic chemical performance, leading to consistent photographic results and safer handling practices.
Related Standards
ISO 3299:1994 references several related ISO standards that contribute to the comprehensive testing and specification of photographic-grade chemicals:
- ISO 10349 Series: General test methods for photographic-grade chemicals, including parts on residue after ignition (Part 4), heavy metals and iron content determination (Part 5), and volatile matter measurement (Part 8).
- ISO 5657: Specification for test sieves, essential for preparing homogeneous powder samples in purity testing.
- ISO/TC 42: The technical committee responsible for photography standards development ensuring updated and precise requirements.
Adherence to these interconnected standards ensures a holistic approach to the analysis and quality assurance of photographic processing chemicals, particularly phenidone.
Keywords: ISO 3299:1994, phenidone specifications, photographic chemicals purity, 1-phenyl-3-pyrazolidinone testing, photographic-grade chemicals, assay methods, chemical safety, photographic processing standards, purity criteria, heavy metals in photographic chemicals.
Frequently Asked Questions
ISO 3299:1994 is a standard published by the International Organization for Standardization (ISO). Its full title is "Photography - Processing chemicals - Specifications for 1-phenyl-3-pyrazolidinone". This standard covers: Cancels and replaces the first edition (1976). Establishes criteria for the purity of photographic-grade 1-phenyl-3-pyrazolidinone (phenidone) and specifies the test methods to be used to determine the purity.
Cancels and replaces the first edition (1976). Establishes criteria for the purity of photographic-grade 1-phenyl-3-pyrazolidinone (phenidone) and specifies the test methods to be used to determine the purity.
ISO 3299:1994 is classified under the following ICS (International Classification for Standards) categories: 37.040.30 - Photographic chemicals. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 3299:1994 has the following relationships with other standards: It is inter standard links to ISO 3299:1976. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase ISO 3299:1994 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of ISO standards.
Standards Content (Sample)
INTERNATIONAL
ISO
STANDARD
Second ediiion
1994-11-01
Photography - Processing chemicals -
Specifications for 1 -phenyl=3=pyrazolidinone
Photographie - Produits chimiques de traitement - Spkifications pour Ia
ph& yi- 1 p yrazolidinone-3
Reference number
ISO 3299: 1994(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide
federation of national standards bodies (ISO member bodies). The work of
preparing International Standards is normally carried out through ISO
technical committees. Esch member body interested in a subject for which
a technical committee has been established has the right to be
represented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work. ISO
collaborates closely with the International Electrotechnical Commission
(IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are
circulated to the member bodies for voting. Publication as an International
Standard requires approval by at least 75 % of the member bodies casting
a vote.
International Standard ISO 3299 was prepared by Technical Committee
ISO/TC 42, Photography.
This second edition cancels and replaces the first edition (ISO 3299:1976)
which has been technically revised.
0 ISO 1994
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any means, electronie or mechanical, rncluding photocopyrng and
microfilm, wrthout permrssron In wnting from the publisher.
International Organizatron for Standardization
CH-1 211 Geneve 20 l Switzerland
Case postale 56 l
Pnnted in Swrtzerland
0 ISO
ISO 3299: 1994(E)
0.1 This International Standard is one of a series that establishes criteria
of purity for chemicals used in processing photographic materials. General
test methods and procedures cited in this International Standard are
compiled in Parts 1, 4, 5 and 8 of ISO 10349.
This International Standard is intended for use by individuals with a
working knowledge of analytical techniques, which may not always be the
case. Some of the procedures utilize caustic, toxic or otherwise hazardous
chemicals. Safe laboratory practice for the handling of chemicals requires
the use of safety glasses or goggles, rubber gloves and other protective
apparel such as face masks or aprons where appropriate. Normal
precautions required in the Performance of any Chemical procedure are to
be exercised at all times but care has been taken to provide warnings for
hazardous materials. Hazard warnings designated by a letter enclosed in
angle brackets, < >, are used as a reminder in those Steps detailing
handling operations and are defined in ISO 10349-1. More detailed
information regarding hazards, handling and use of these chemicals may
be available from the manufacturer.
0.2 This International Standard provides Chemical and physical re-
quirements for the suitability of a photographit-grade Chemical. The tests
correlate with undesirable photographic effects. Purity requirements are
set as low as possible consistent with these photographic effects. These
criteria are considered the minimum requirements necessary to assure
sufficient purity for use in photographic processing solutions, except that if
the purity of a commonly available grade of Chemical exceeds photographic
processing requirements and if there is no economic penalty in its use, the
purity requirements have been set to take advantage of the availability of
the higher-quality material. Every effort has been made to keep the
number of requirements to a minimum. Inert impurities are limited to
amounts which will not unduly reduce the assay. All tests are performed
on samples “as received” to reflect the condition of materials furnished for
use. Although the ultimate criterion for suitability of such a Chemical is its
successful Performance in an appropriate use test, the shorter, more
economical test methods described in this International Standard are
generally adequate.
Assay procedures have been included in all cases where a satisfactory
method is available. An effective assay requirement serves not only as a
safeguard of Chemical purity but also as a valuable complement to the
identity test. Identity tests have been included whenever a possibility
exists that another Chemical or mixture of chemicals could pass the other
tests.
All requirements listed in clause 4 are mandatory. The physical appearance
of the material and any footnotes are for general Information only and are
not part of the requirements.
ISO 3299: 1994(E) 0 ISO
0.3 Efforts have been made to employ tests which are capable of being
run in any normally equipped laboratory and, wherever possible, to avoid
tests which require highly specialized equipment or techniques. lnstru-
mental methods have been specified only as alternative methods or alone
in those cases where no other satisfactory method is available.
Over the past few years, great improvements have been made in instru-
mentation for various analyses. Where such techniques have equivalent or
greater precision, they may be used in place of the tests described in this
International Standard. Correlation of such alternative procedures with the
given method is the responsibility of the User. In case of disagreement in
results, the method called for in the specification shall prevail. Where a
requirement states “to pass test ”, however, alternative methods shall not
be used.
INTERNATIONAL STANDARD o ISO
ISO 3299: 1994(E)
Photography - Processing chemicals - Specifications for
1 -phenyl+pyrazolidinone
3 General
1 Scope
3.1 Physical properties
This International Standard establishes criteria for the
purity of photographit-grade l-phenyl-3-pyrazolidinone
1 -Phenyl-3-pyrazolidinone, CgH1 oN20, exists as a pale
(phenidone) and specifies the test methods to be used
cream to white powder, free from aggregates or large
to determine the purity.
crystals. lt has a relative molecular mass of 162,ZO.
3.2 Hazardous properties
2 Normative references
1 -Phenyl-3-pyrazolidinone is not hazardous when
The following International Standards contain pro-
handled with normal precautions.
visions which, through reference in this text, consti-
tute provisions of this International Standard. At the
time of publication, the editions indicated were valid.
3.3 Handling and storage
All Standards are subject to revision, and Parties to
agreements based on this International Standard are
l-Phenyl-3-pyrazolidinone shall be stored in a closed
encouraged to investigate the possibility of applying
Container at room temperature.
the most recent editions of the Standards indicated
below. Members of IEC and ISO maintain registers of
currently valid International Standards.
4 Requirements
A summary of the requirements is shown in table 1.
ISO 5657 983, Test sieves - Woven metal wire cloth,
perforated plate and electroformed sheet - Nominal
sizes of openings.
5 Reagents and glassware
ISO 10349-1:1992, Photography - Photographic-
All reagents, materials and glassware shall conform to
grade chemicals - Test methods - Part 1: General.
the requirements specified in ISO 10349-1 unless
otherwise noted. The hazard warning Symbols used
ISO 10349-4: 1992, Photography - Photographic-
as a reminder in those Steps detailing handling
grade chemicals - Test methods - Part 4: Determi-
operations are defined in ISO 10349-1. These Symbols
nation of residue after ignition.
are used to provide information to the user and are
not meant to provide conformance with hazardous
ISO 10349-5: 1992, Photography - Photographic-
labelling requirements, as these vary from country to
grade chemicals - Test methods - Part 5: Determi-
country.
nation of heavy me tals and iron content.
ISO 10349-8:1992, Photography - Photographic-
6 Sampling
grade chemicals - Test methods - Part 8: Determi-
See ISO 10349-1.
na tion of vola tile matter.
Table 1 - Summary of requirements
Test Limit Subclause International
Standard in
which test
method is given
Assay 98,5 % (m/m) min. 7.1 ISO3299
Identity
119"Ct0122"C 7.2.1 ISO3299
melting Point
mixed melting Point Not lower than Sample 7.2.1
or Standard
,infrared spectrum Match reference 7.2.2
spectrum
Residue after ignition 0,lO % (m/m) max. 7.3 ISOlO349-4
Heavy metals (as Pb) 0,002 % (m/m) max. 7.4 ISO 10349-5
Iran (Fe) 0,005 % (m/m) max. 7.5 ISO 10349-5
ISO 10349-8
Volatile matter 0,lO % (m/m) max. 7.6
Solubility in alkaline sulfite Clear and colourless 7.7 ISO 3299
Solution or slight pink
Matter insoluble in 0,lO % (m/m) max. 7.8 ISO 3299
chloroform (optional)
NOTE - m/m = mass/mass
I
7 Test methods 7.1.2.6 Sodium thiosul
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...